Leo Tomasevic
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Leo Tomasevic has a total of 127 co-authors. Here are the top co-authors by number of shared publications:
- Franca Tecchio
Laboratory of Electrophysiology for Translational NeuroScience (LET’S), Institute of Cognitive Sciences and Technologies—Consiglio Nazionale delle Ricerche, 00196 Rome, Italy
11 shared publications - Hartwig Roman Siebner
Danish Research Centre for Magnetic Resonance, Department of Radiology and Nuclear Medicine, Copenhagen University Hospital - Amager and Hvidovre
11 shared publications - Axel Thielscher
Department of Health Technology, Technical University of Denmark, Kongens Lyngby, Denmark
6 shared publications - Camillo Porcaro
Department of Neuroscience and Padova Neuroscience Center, University of Padova, 35128 Padova, Italy
5 shared publications Hartwig Roman Siebner
Danish Research Centre for Magnetic Resonance, Centre for Functional and Diagnostic Imaging and Research, Copenhagen University Hospital - Amager and Hvidovre
5 shared publicationsAxel Thielscher
Danish Research Centre for Magnetic Resonance, Centre for Functional and Diagnostic Imaging and Research, Copenhagen University Hospital - Amager and Hvidovre, Copenhagen, Denmark; Department of Health Technology, Technical University of Denmark, Kgs Lyngby, Denmark
4 shared publications
Latest Publications
- Open Access
Opposing modulation of cortical and corticospinal excitability across movement-related beta stages
Discrete voluntary movement depends on rapid changes in neural excitability across cortical and corticospinal circuits, yet how intrinsic movement-related neural states shape multi-level excitability remains unclear. Here, we combined individualized, state-targeted transcranial magnetic stimulation (TMS) with electroencephalography and electromyography recordings during visually cued finger movements to probe excitability across movement-related beta-band dynamics during two complementary experiments. Immediate transsynaptic cortical excitability closely tracked intrinsic beta dynamics, with attenuation of the second immediate TMS-evoked potential during beta desynchronization and recovery during the post-movement beta rebound. In contrast, corticospinal excitability showed the opposite pattern, with larger motor-evoked potentials during beta desynchronization and reduced responses during beta rebound. Together, these findings identify endogenous beta-state dynamics as a key regulator of movement-related cortical excitability and reveal a fundamental dissociation between how intrinsic brain activity tunes local cortical excitability and corticospinal output in humans.
Open AccessOpposing modulation of cortical and corticospinal excitability across movement-related beta stages
Discrete voluntary movement depends on rapid changes in neural excitability across cortical and corticospinal circuits, yet how intrinsic movement-related neural states shape multi-level excitability remains unclear. Here, we combined individualized, state-targeted transcranial magnetic stimulation (TMS) with electroencephalography and electromyography recordings during visually cued finger movements to probe excitability across movement-related beta-band dynamics during two complementary experiments. Immediate transsynaptic cortical excitability closely tracked intrinsic beta dynamics, with attenuation of the second immediate TMS-evoked potential during beta desynchronization and recovery during the post-movement beta rebound. In contrast, corticospinal excitability showed the opposite pattern, with larger motor-evoked potentials during beta desynchronization and reduced responses during beta rebound. Together, these findings identify endogenous beta-state dynamics as a key regulator of movement-related cortical excitability and reveal a fundamental dissociation between how intrinsic brain activity tunes local cortical excitability and corticospinal output in humans.
- Open Access
Rostro-caudal TMS mapping of immediate transcranial evoked potentials reveals a pericentral crescendo-decrescendo pattern
Background: We recently demonstrated that single-pulse TMS of the primary sensorimotor hand area (SM1 HAND ) elicits an immediate transcranial evoked potential (iTEP). This iTEP response appears within 2–7 ms post-TMS, featuring high-frequency peaks superimposed on a slow positive wave. Here, we used a linear TMS-EEG mapping approach to characterize the rostro-caudal iTEP expression and compared it to that of motor-evoked potentials (MEPs). Methods: In 15 healthy young volunteers (9 females), we identified the iTEP hotspot in left SM1 HAND . We applied single biphasic TMS pulses at an intensity of 110% of resting motor threshold over six cortical sites along a rostro-caudal axis (2 cm rostral to 3 cm caudal to the SM1 HAND hotspot). We analyzed site-specific iTEP and MEP responses. Results: iTEP magnitude decreased rostrally and caudally from the SM1 HAND hotspot. MEPs exhibited a similar rostro-caudal crescendo-decrescendo pattern. While iTEP and MEP response profiles were similar, normalized iTEP amplitudes decayed less rapidly at the first postcentral site. Discussion: These findings support the idea that pericentral iTEPs reflect a direct response signature of the pericentral cortex, possibly involving a synchronized TMS-induced excitation of cortical pyramidal tract neurons. Similar but non-identical rostro-caudal patterns suggest that iTEPs and MEPs may arise from overlapping but distinct neuronal populations.
Open AccessRostro-caudal TMS mapping of immediate transcranial evoked potentials reveals a pericentral crescendo-decrescendo pattern
Background: We recently demonstrated that single-pulse TMS of the primary sensorimotor hand area (SM1 HAND ) elicits an immediate transcranial evoked potential (iTEP). This iTEP response appears within 2–7 ms post-TMS, featuring high-frequency peaks superimposed on a slow positive wave. Here, we used a linear TMS-EEG mapping approach to characterize the rostro-caudal iTEP expression and compared it to that of motor-evoked potentials (MEPs). Methods: In 15 healthy young volunteers (9 females), we identified the iTEP hotspot in left SM1 HAND . We applied single biphasic TMS pulses at an intensity of 110% of resting motor threshold over six cortical sites along a rostro-caudal axis (2 cm rostral to 3 cm caudal to the SM1 HAND hotspot). We analyzed site-specific iTEP and MEP responses. Results: iTEP magnitude decreased rostrally and caudally from the SM1 HAND hotspot. MEPs exhibited a similar rostro-caudal crescendo-decrescendo pattern. While iTEP and MEP response profiles were similar, normalized iTEP amplitudes decayed less rapidly at the first postcentral site. Discussion: These findings support the idea that pericentral iTEPs reflect a direct response signature of the pericentral cortex, possibly involving a synchronized TMS-induced excitation of cortical pyramidal tract neurons. Similar but non-identical rostro-caudal patterns suggest that iTEPs and MEPs may arise from overlapping but distinct neuronal populations.
- Open Access
- 22 June 2024
- Published by Elsevier in Brain Stimulation
- Vol. 17 (4) , 802-812
Transcranial magnetic stimulation of primary motor cortex elicits an immediate transcranial evoked potential
- 22 June 2024
- Published by Elsevier in Brain Stimulation
- Vol. 17 (4) , 802-812
Open AccessTranscranial magnetic stimulation of primary motor cortex elicits an immediate transcranial evoked potential
- Open Access
Transcranial magnetic stimulation of primary motor cortex elicits a site-specific immediate transcranial evoked potential
Background: Transcranial evoked potentials (TEPs) measured via electroencephalography (EEG) are widely used to study the cortical responses to transcranial magnetic stimulation (TMS). Immediate transcranial evoked potentials (i-TEPs) have been obscured by pulse and muscular artifacts. Thus, the TEP peaks that are commonly reported have latencies that are too long to be caused by direct excitation of cortical neurons. Methods: In 14 healthy individuals, we recorded i-TEPs evoked by a single biphasic TMS pulse targeting the primary motor hand area (M1 HAND ) or parietal or midline control sites. Sampling EEG at 50 kHz enabled us to reduce the duration of the TMS pulse artifact to a few milliseconds, while minor adjustments of the TMS coil tilt or position enabled us to avoid cranial muscular twitches during the experiment. Results: We observed an early positive EEG deflection starting after approx. 2 ms combined with a series of peaks with an inter-peak interval of ∼1.1-1.4 ms in electrodes overlying the stimulated sensorimotor region. This multi-peak i-TEP response was only evoked by TMS of the M1 HAND region and was modified by changes in stimulation intensity and current direction. Discussion: Single-pulse TMS of the M1 HAND evokes an immediate local multi-peak response at the cortical site of stimulation. Our results suggest that the observed i-TEP patterns are genuine cortical responses evoked by TMS caused by synchronized excitation of pyramidal neurons in the targeted precentral cortex. This notion needs to be corroborated in future studies, including further investigations into the potential contribution of instrumental or physiological artifacts.
Open AccessTranscranial magnetic stimulation of primary motor cortex elicits a site-specific immediate transcranial evoked potential
Background: Transcranial evoked potentials (TEPs) measured via electroencephalography (EEG) are widely used to study the cortical responses to transcranial magnetic stimulation (TMS). Immediate transcranial evoked potentials (i-TEPs) have been obscured by pulse and muscular artifacts. Thus, the TEP peaks that are commonly reported have latencies that are too long to be caused by direct excitation of cortical neurons. Methods: In 14 healthy individuals, we recorded i-TEPs evoked by a single biphasic TMS pulse targeting the primary motor hand area (M1 HAND ) or parietal or midline control sites. Sampling EEG at 50 kHz enabled us to reduce the duration of the TMS pulse artifact to a few milliseconds, while minor adjustments of the TMS coil tilt or position enabled us to avoid cranial muscular twitches during the experiment. Results: We observed an early positive EEG deflection starting after approx. 2 ms combined with a series of peaks with an inter-peak interval of ∼1.1-1.4 ms in electrodes overlying the stimulated sensorimotor region. This multi-peak i-TEP response was only evoked by TMS of the M1 HAND region and was modified by changes in stimulation intensity and current direction. Discussion: Single-pulse TMS of the M1 HAND evokes an immediate local multi-peak response at the cortical site of stimulation. Our results suggest that the observed i-TEP patterns are genuine cortical responses evoked by TMS caused by synchronized excitation of pyramidal neurons in the targeted precentral cortex. This notion needs to be corroborated in future studies, including further investigations into the potential contribution of instrumental or physiological artifacts.
- Open Access
- 15 February 2023
- Published by Elsevier in Brain Stimulation
- Vol. 16 (1) , 185
Pros and cons of the existing sham protocols in TMS/EEG, and approaches to deal with the related artifacts
- 15 February 2023
- Published by Elsevier in Brain Stimulation
- Vol. 16 (1) , 185
Open AccessPros and cons of the existing sham protocols in TMS/EEG, and approaches to deal with the related artifacts
- Open Access
Microscopic-scale recording of brain neuronal electrical activity using a diamond quantum sensor
An important tool in the investigation of the early stages of neurodegenerative disease is the study of dissected living tissue from the brain of an animal model. Such investigations allow the physical structure of individual neurons and neural circuits to be probed alongside neuronal electrical activity, disruption of which can shed light on the mechanisms of emergence of disease. Existing techniques for recording activity rely on potentially damaging direct interaction with the sample, either mechanically as point electrical probes or via intense focused laser light combined with highly specific genetic modification and/or potentially toxic fluorescent dyes. In this work, we instead perform passive, microscopic-scale recording of electrical activity using a biocompatible quantum sensor based on colour centres in diamond. We record biomagnetic field induced by ionic currents in mouse corpus callosum axons without direct sample interaction, accurately recovering signals corresponding to action potential propagation while demonstrating in situ pharmacology during biomagnetic recording through tetrodotoxin inhibition of voltage gated sodium channels. Our results open a promising new avenue for the microscopic recording of neuronal signals, offering the prospect of high resolution imaging of electrical circuits in the living mammalian brain.
Open AccessMicroscopic-scale recording of brain neuronal electrical activity using a diamond quantum sensor
An important tool in the investigation of the early stages of neurodegenerative disease is the study of dissected living tissue from the brain of an animal model. Such investigations allow the physical structure of individual neurons and neural circuits to be probed alongside neuronal electrical activity, disruption of which can shed light on the mechanisms of emergence of disease. Existing techniques for recording activity rely on potentially damaging direct interaction with the sample, either mechanically as point electrical probes or via intense focused laser light combined with highly specific genetic modification and/or potentially toxic fluorescent dyes. In this work, we instead perform passive, microscopic-scale recording of electrical activity using a biocompatible quantum sensor based on colour centres in diamond. We record biomagnetic field induced by ionic currents in mouse corpus callosum axons without direct sample interaction, accurately recovering signals corresponding to action potential propagation while demonstrating in situ pharmacology during biomagnetic recording through tetrodotoxin inhibition of voltage gated sodium channels. Our results open a promising new avenue for the microscopic recording of neuronal signals, offering the prospect of high resolution imaging of electrical circuits in the living mammalian brain.
- Open Access
- 4 May 2022
- Published by Elsevier in Brain Stimulation
- Vol. 15 (3) , 717-726
Relationship between high-frequency activity in the cortical sensory and the motor hand areas, and their myelin content
- 4 May 2022
- Published by Elsevier in Brain Stimulation
- Vol. 15 (3) , 717-726
Open AccessRelationship between high-frequency activity in the cortical sensory and the motor hand areas, and their myelin content
- Open Access
Relationship between high-frequency activity in the cortical sensory and the motor hand areas, and their myelin content
Background: The human primary sensory (S1) and primary motor (M1) hand areas feature high-frequency neuronal responses. Electrical nerve stimulation evokes high-frequency oscillations (HFO) at around 650 Hz in the contralateral S1. Likewise, transcranial magnetic stimulation (TMS) of M1 can evoke a series of descending volleys in the corticospinal pathway that can be detected non-invasively with a paired-pulse TMS protocol, called short interval intracortical facilitation (SICF). SICF features several peaks of facilitation of motor evoked potentials in contralateral hand muscles, which are separated by inter-peak intervals resembling HFO rhythmicity. Hypothesis: In this study, we tested the hypothesis that the individual expressions of HFO and SICF are tightly related to each other and to the regional myelin content in the sensorimotor cortex. Methods: In 24 healthy volunteers, we recorded HFO and SICF, and, in a subgroup of 20 participants, we mapped the cortical myelin content using the ratio between the T1- and T2-weighted MRI signal as read-out. Results: The individual frequencies and magnitudes of HFO and SICF curves were tightly correlated: the intervals between the first and second peak of cortical HFO and SICF showed a positive linear relationship (r= 0.703, p< 0.001), while their amplitudes were inversely related (r= −0.613, p= 0.001). The rhythmicity, but not the magnitude of the high-frequency responses, was related to the cortical myelin content: the higher the cortical myelin content, the shorter the inter-peak intervals of HFO and SICF. Conclusion: The results confirm a tight functional relationship between high-frequency responses in S1 (i.e., HFO) and M1 (i.e., as measured with SICF). They also establish a link between the degree of regional cortical myelination and the expression of high-frequency responses in the human sensorimotor cortex, giving further the opportunity to infer their generators.
Open AccessRelationship between high-frequency activity in the cortical sensory and the motor hand areas, and their myelin content
Background: The human primary sensory (S1) and primary motor (M1) hand areas feature high-frequency neuronal responses. Electrical nerve stimulation evokes high-frequency oscillations (HFO) at around 650 Hz in the contralateral S1. Likewise, transcranial magnetic stimulation (TMS) of M1 can evoke a series of descending volleys in the corticospinal pathway that can be detected non-invasively with a paired-pulse TMS protocol, called short interval intracortical facilitation (SICF). SICF features several peaks of facilitation of motor evoked potentials in contralateral hand muscles, which are separated by inter-peak intervals resembling HFO rhythmicity. Hypothesis: In this study, we tested the hypothesis that the individual expressions of HFO and SICF are tightly related to each other and to the regional myelin content in the sensorimotor cortex. Methods: In 24 healthy volunteers, we recorded HFO and SICF, and, in a subgroup of 20 participants, we mapped the cortical myelin content using the ratio between the T1- and T2-weighted MRI signal as read-out. Results: The individual frequencies and magnitudes of HFO and SICF curves were tightly correlated: the intervals between the first and second peak of cortical HFO and SICF showed a positive linear relationship (r= 0.703, p< 0.001), while their amplitudes were inversely related (r= −0.613, p= 0.001). The rhythmicity, but not the magnitude of the high-frequency responses, was related to the cortical myelin content: the higher the cortical myelin content, the shorter the inter-peak intervals of HFO and SICF. Conclusion: The results confirm a tight functional relationship between high-frequency responses in S1 (i.e., HFO) and M1 (i.e., as measured with SICF). They also establish a link between the degree of regional cortical myelination and the expression of high-frequency responses in the human sensorimotor cortex, giving further the opportunity to infer their generators.
- Open Access
Profiling the transcallosal response of rat motor cortex evoked by contralateral optogenetic stimulation of glutamatergic cortical neurons
Background Efficient interhemispheric integration of neural activity between left and right primary motor cortex (M1) is critical for inter-limb motor control. Objective We employed optogenetic stimulation to establish a framework for probing transcallosal M1-M1 interactions in rats. Methods In male rats, we optogenetically stimulated glutamatergic neurons in right M1 and recorded the transcallosally evoked potential with chronically implanted electrodes in contralateral left M1 during dexmedetomidine anesthesia. We systematically varied the stimulation intensity and duration to characterize the relationship between stimulation parameters in right M1 and the characteristics of the evoked intracortical potentials in left M1. Results Optogenetic stimulation of right M1 consistently evoked a transcallosal response in left M1 with a consistent negative peak (N1) that sometimes was preceded by a smaller positive peak (P1). Higher stimulation intensity or longer stimulation duration gradually increased N1 amplitude and reduced N1 variability across trials. Median N1 latencies remained stable, once stimulation elicited a reliable N1 peak and did not display a systematic shortening with increasing stimulation intensity or duration. Conclusions Optogenetically stimulated glutamatergic neurons in M1 can reliably evoke a transcallosal response in anesthetized rats and can be used to characterize the relationship between “stimulation dose” and “response magnitude” (i.e., the gain function) of transcallosal M1-to-M1 glutamatergic connections. Detailed knowledge of the stimulus-response relationship is needed to optimize the efficacy of optogenetic stimulation. Since transcallosal M1-M1 interactions can also be probed non-invasively with transcranial magnetic stimulation in humans, our optogenetic stimulation approach bears translational potential for studying how unilateral M1 stimulation can induce interhemispheric plasticity.
Open AccessProfiling the transcallosal response of rat motor cortex evoked by contralateral optogenetic stimulation of glutamatergic cortical neurons
Background Efficient interhemispheric integration of neural activity between left and right primary motor cortex (M1) is critical for inter-limb motor control. Objective We employed optogenetic stimulation to establish a framework for probing transcallosal M1-M1 interactions in rats. Methods In male rats, we optogenetically stimulated glutamatergic neurons in right M1 and recorded the transcallosally evoked potential with chronically implanted electrodes in contralateral left M1 during dexmedetomidine anesthesia. We systematically varied the stimulation intensity and duration to characterize the relationship between stimulation parameters in right M1 and the characteristics of the evoked intracortical potentials in left M1. Results Optogenetic stimulation of right M1 consistently evoked a transcallosal response in left M1 with a consistent negative peak (N1) that sometimes was preceded by a smaller positive peak (P1). Higher stimulation intensity or longer stimulation duration gradually increased N1 amplitude and reduced N1 variability across trials. Median N1 latencies remained stable, once stimulation elicited a reliable N1 peak and did not display a systematic shortening with increasing stimulation intensity or duration. Conclusions Optogenetically stimulated glutamatergic neurons in M1 can reliably evoke a transcallosal response in anesthetized rats and can be used to characterize the relationship between “stimulation dose” and “response magnitude” (i.e., the gain function) of transcallosal M1-to-M1 glutamatergic connections. Detailed knowledge of the stimulus-response relationship is needed to optimize the efficacy of optogenetic stimulation. Since transcallosal M1-M1 interactions can also be probed non-invasively with transcranial magnetic stimulation in humans, our optogenetic stimulation approach bears translational potential for studying how unilateral M1 stimulation can induce interhemispheric plasticity.
- Open Access
- 1 May 2020
- Published by Elsevier in Brain Stimulation
- Vol. 13 (3) , 815-818
Probing EEG activity in the targeted cortex after focal transcranial electrical stimulation
- 1 May 2020
- Published by Elsevier in Brain Stimulation
- Vol. 13 (3) , 815-818
Open AccessProbing EEG activity in the targeted cortex after focal transcranial electrical stimulation