KWKiing Ing Wong

Kiing Ing Wong

*This is an algorithmically generated author record based on publicly available information.

Kiing Ing Wong has a total of 51 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • A Low-Cost Marker-Based Optical Motion Capture System to Validate Inertial Measurement Units

    by Teck Ung Siaw, Yi Chiew Han, Kiing Ing Wong

    Commercialized marker-based optical motion capture system like Vicon is very expensive, and not widely available. In the development of inertial measurement units, Vicon is required only for validation so sourcing for expensive system is undesirable. In this paper, a low cost alternative, which is also a marker-based optical motion capture system, is proposed to serve the purpose of validating inertial measurement units. Basically, the proposed system uses a smartphone camera to capture the motions of red markers, then track the coordinates of the markers followed by calculating the angle. The proposed system has a low average root mean square error of 0.83º when the distance between camera and markers is 120cm. The method to synchronize inertial measurement units and camera data is also described in this paper as starting time and sampling rate of the two systems are most likely different.


  • Stride Length Estimation Based on a Single Shank's Gyroscope

    by Yi Chiew Han, Kiing Ing Wong, Iain Murray

    IMU-based stride length estimation remains as a challenging problem despite many researchers have tried to use frequency, vertical acceleration, and/or angle to estimate the stride length. In this paper, we propose 3 new features that can be extracted from a single shank's gyroscope for stride length estimation. We first noticed that the shank's horizontal displacement increases mainly during its extension, while remains almost unchanged during its flexion. The horizontal displacement $s$ during the shank's extension was treated as a linear increment, and therefore a linear kinematic equation $s = 0.5(u + v)t$ could be applied. The initial velocity $u$ is estimated as the average angular velocity during shank's flexion, while the final velocity $v$ is estimated as the summation of angular velocity during the whole stride. The time $t$ is estimated as the duration of the shank's extension rather than the duration of the whole stride. This proposed method had resulted in a low mean absolute error of 4.2cm with a standard deviation of 5.5cm.


  • Corrections to “Gait Phase Detection for Normal and Abnormal Gaits Using IMU” [May 19 3439-3448]

    by Yi Chiew Han, Kiing Ing Wong, Iain Murray

    In the above paper [1] , Table I is corrected as follows.


  • Open Access

    Grounding grid design in electrical power substation using optimization methods

    by V K Voon, K I Wong, T C Tiong, A Mansour, K H Law

    A good substation grounding grid is essential to ensure safety of personnel working in the substation, and also to protect the equipment to ensure continuous operation of the substation. The design of the substation grounding grid is often carried out to meet the IEEE Std 80-2000 requirements of grounding resistance, touch voltage and step voltage at an economical cost. However, the conventional grounding grid design is normally over calculated to meets these IEEE requirements without considering the total cost. The grounding grid is often costly to implement due to high number of grounding conductors and rods, and large area size of the interconnected bare conductors. In this study, Gravitational Search Algorithm (GSA) and Particle Swarm Algorithm (PSO) are proposed to achieve an effective grounding grid calculation. The reliability of these algorithms has been validated using a typical medium voltage substation grounding grid parameters. It was found both that GSA and PSO were capable to achieve a lower cost with of grounding grid with 29% cost saving as compared to the conventional calculation technique, without compromising the safety requirements of grounding grid.


  • Open Access

    Active Harmonic Filtering Using Multilevel H-bridge Inverter Based STATCOM

    by K H Law, W P Q Ng, K I Wong

    This paper proposed three-phase multilevel cascaded H-bridge inverter (MCHI) based active harmonic filtering (AHF) compensator, or refer to as static synchronous compensator (STATCOM), to minimize the harmonic components in a transmission network. There are three main elements to form a STATCOM, namely: control scheme, modulation technique and inverter topology. In this work, the synchronous reference frame (SRF) based controller is designed and implemented to produce the desired modulating signals (i.e., one for each phase) for the pulse width modulation (PWM) module. For simplicity, the carrier based pulse width modulation (CBPWM) with in phase disposition (IPD) technique is employed to generate the pulse trains and drive the three-phase five-level CHI. On the other hand, two three-phase non-linear loading conditions, which structured by different transformer winding configurations and power rectifier circuits, are utilized to verify the feasibility of the proposed AHF. The effectiveness and the theoretical prediction of the proposed approach is investigated and validated through simulation studies using MATLAB SIMULINK software package.


  • Mathematics Derivation and Simulation Modelling of Maximum Power Point Tracking based Controller for Quasi Z Source Inverter

    by Kah Haw Law, Wan Ning Loh, Kiing Ing Wong

    The ability of the quasi Z-source inverter (qZSI) to perform buck/boost conversions in a single stage topology has made it highly preferable to be implemented into a photovoltaic (PV) system. In this paper, PV array are selected as the DC input source for the qZSI. A dual-loop DC-link control scheme, which constructed with lead compensator and proportional (P) controller, is proposed to achieve constant DC-link voltage under varying solar irradiance and temperature. In addition, perturb and observe (P&O) based maximum power point tracking (MPPT) scheme is employed and incorporated with the aforementioned control scheme to ensure maximum power extraction and delivery to the load. For simplicity, carrier based pulse width modulation (CB-PWM) technique is utilized to generate stepped AC waveform with the qZSI. The potency of the proposed controllers for the qZSI with and without the implementation of MPPT is justified through intensive theoretical mathematics and simulation studies to achieved the previously mentioned outcomes.


  • Automatic Synchronization of Markerless Video and Wearable Sensors for Walking Assessment

    by Yi Chiew Han, Kiing Ing Wong, Iain Murray

    As walking assessment is commonly done through visual inspection, it is beneficial to make joint angle information available to the clinicians for better assessment. The main challenge is that the video camera and inertial sensor are usually two separate systems, and the recordings are hard to be initialized at the same time manually. This creates a problem that the inertial sensor data is not temporally synchronized with the video camera. This paper proposes a method to synchronize the video and sensor data by detecting and matching the maximum backward swings of the leg. The proposed method is validated by blinking LED and transmitting LED flag to the computer at the same time. The synchronization error of the proposed method is low at about 0±2 frames compared to the validation method.


  • Analysis of Electrical Distribution System for Offshore Oil and Gas Platform

    by Kiing Ing Wong, Kah Haw Law, Teck Ung Siaw, Chieng Kai Wong, Nader N. Barsoum

    The electrical power system of a medium size offshore oil and gas platform is studied by using a power system simulator software, namely ETAP. The load flow and short circuit analyses under various operating conditions are carried out, including normal, service, emergency and black start operation. The operations that generate maximum and minimum fault current magnitudes at the main switchboard and electric submersible pump are calculated, respectively. The protective device coordination is achieved by using the time-current curve tool of ETAP. The component ratings, voltage drop, and protection device setting are evaluated based on the results obtained from these analyses. A modern multifunctional transformer relay is proposed on a 2240kVA 6.6/0.415 kV transformer to provide a comprehensive protection and control. The overcurrent tripping time is reduced by using the combination of instantaneous and time-delay protection functions of the multifunctional transformer relay, hence mitigate the arc flash damages to the system and improve safety for personal. The relay is assessed in the laboratory by using a secondary current injection tester. The result shows that the correctness of the relay setting. The future work includes transformer internal fault studies and testing, and integration of protection systems with plant automation.


  • Gait Phase Detection for Normal and Abnormal Gaits Using IMU

    by Yi Chiew Han, Kiing Ing Wong, Iain Murray

    Gait phase detection is essential for clinicians to examine the gait cycles of human test subjects. In this research, a method to detect normal and abnormal gait phases using a single inertial measurement unit (IMU) attached to the shank is proposed. The local maxima, minima and zero crossings of the shank’s angular velocity and acceleration are used to detect heel strike, toe strike and toe off. The proposed method may provide human-understandable insights into the shank’s angular velocity and acceleration to assist clinicians to evaluate the patients’ gaits. The proposed method is compared with an existing method that uses force sensitive resistors (FSRs) placed under the foot. The mean absolute sample difference between the proposed and existing methods is low at around 2 sample difference, equivalent to 20ms difference.


  • 2-Point Error Estimation Algorithm for 3-D Thigh and Shank Angles Estimation Using IMU

    by Yi Chiew Han, Kiing Ing Wong, Iain Murray

    Inertial measurement units (IMUs) have been widely used for many applications such as aircrafts, gaming, animation, and sports. However, the use of IMU in medical diagnosis is still largely unexplored. A great deal of researcher has focused on estimating the pitch angle using accelerometer and gyroscope, while some researchers managed to estimate the roll angle, not many researchers have extended their research to estimate the yaw angle. For those who estimate the yaw angle, the utilization of magnetometer is common, but it requires a more complex algorithm to tackle the magnetic interference. This paper presents an innovative method, called the 2-point error estimation algorithm, to estimate the pitch, roll, and yaw angles using the accelerometer and gyroscope-only. The proposed algorithm is also very computationally efficient to estimate 3-D angles as only two “atan2()” functions are computed throughout the whole walking motion, and seven additions and four multiplications for each angle estimated. The accuracy of the 3-D angles estimated using the IMU is validated against the gold standard Vicon optical motion capture system. The proposed algorithm gives a low average root mean square error of 2.9°, 3.6°, and 4.2° for flexion/extension (pitch), adduction/abduction (roll), and internal/external rotation (yaw) angles of the thigh and shank, respectively. The proposed algorithm can be used to design a low-cost 3-D gait evaluation system.