LSLeena N. Shoemaker

Leena N. Shoemaker

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Leena N. Shoemaker has a total of 57 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Cerebral Hemodynamic and Metabolic Responses to Anesthesia and Vasopressors in Adult Shoulder Surgery: A 2 × 2 Factorial Design Randomized Controlled Trial with Light-based Neuromonitoring (CHEM-FACT Study)

    by Saeed Samaei, Leena Shoemaker, Farah Kamar, Daniel Milej, Darren Drosdowech, John M. Murkin, Mamadou Diop, Keith St. Lawrence, Jason Chui

    Background: Ephedrine has been suggested to improve cerebral microcirculation and perfusion compared with phenylephrine. However, prospective intraoperative data are lacking, and possible interactions with anesthetic choice remain untested. Methods: Forty adults undergoing shoulder surgery in the beach chair position were recruited between February and November 2024 at St. Joseph’s Hospital (London, Canada). Patients were randomized in a 2 × 2 factorial design to anesthetic maintenance (propofol vs . sevoflurane) and vasopressor strategy (phenylephrine infusion vs . ephedrine boluses). Relative tissue oxygenation saturation (rStO 2 ) and the relative cerebral metabolic rate of oxygen (rCMRO 2 ), the coprimary outcomes, were monitored using an in-house hybrid optical system combining time-resolved near-infrared spectroscopy and diffuse correlation spectroscopy. Only data from the first 30 min after positioning were analyzed. Outcomes and interactions were assessed using linear mixed-effects models. Results: Of the 40 patients, 39 were analyzed. Neither anesthetic nor vasopressor choice showed a significant main effect on average rStO 2 or rCMRO 2 during the 30-min period. However, analysis of temporal changes revealed rStO 2 declined over time (β = –0.005 per minute; χ 2 (1) = 10.2; P = 0.001), while rCMRO 2 increased (β = 3.2 per minute; χ 2 (1) = 35.2; P < 0.001). There was a time by vasopressor interaction for rStO 2 (β = –0.0014; χ 2 (1) = 8.4; P = 0.004), with phenylephrine producing a 9% greater decline during 30 min compared to ephedrine, while for relative rCMRO 2 (β = 2.2; 95% CI, 0.6 to 3.8; P = 0.007), phenylephrine produced a 70% increase during 30 min. Conclusions: This trial found no overall effect of anesthetic or vasopressor choice on rStO 2 or rCMRO 2 during the first 30 min of surgery, suggesting that initial cerebral physiologic responses were comparable across treatment combinations. However, phenylephrine was associated with progressive cerebral desaturation and increasing metabolic demand over time.


  • Open Access

    Reproducibility of a time-resolved NIRS, multidistance diffuse correlation spectroscopy system: towards noninvasive longitudinal neuromonitoring

    by Farah Kamar, Leena N. Shoemaker, Saeed Samaei, Daniel Milej, Mamadou Diop, Keith St. Lawrence

    SignificanceLongitudinal monitoring of cerebral blood flow (CBF), oxygenation (StO2), and cerebral metabolic rate of oxygen (CMRO2) could allow for early detection of secondary brain injury before clinical signs manifest.AimReproducibility and reliability of an in-house time-resolved near-infrared spectroscopy (trNIRS)/multidistance diffuse correlation spectroscopy (mdDCS) system were assessed to determine the feasibility of daily monitoring. In addition, carotid compression was performed to demonstrate longitudinal monitoring.ApproachTime-resolved NIRS/mdDCS measurements were acquired daily on volunteers across one week. Reproducibility was quantified by the coefficient of variation (CV) and reliability by the intraclass correlation coefficient (ICC) at three levels: within-acquisition, between-acquisition, and between-day. A subset of participants returned on day 21+, and carotid compression was performed to reduce CBF. Signal changes during compression were compared to baseline measurements from that day and previous days.ResultsAll optical measurements showed good-to-excellent within-acquisition, between-acquisition, and between-day reproducibility (CV<19%) and reliability (ICC between 0.67 and 0.99), except short-distance DCS, which was sensitive to probe repositioning. Reductions in CBF, StO2, and CMRO2 caused by carotid compression were similar in magnitude when using same-day baseline to baseline values up to three weeks prior.ConclusionsThis study demonstrates the feasibility of daily monitoring using a hybrid trNIRS/mdDCS system.

  • Two paths to one destination: altered low-frequency oscillations of cerebral perfusion and oxygenation but not oxygen metabolism in mild cognitive impairment

    by Leena N. Shoemaker, Farah Kamar, Daniel Milej, Laura Fitzgibbon-Collins, Rasa Eskandari, Jaspreet Bhangu, J. Kevin Shoemaker, Keith St Lawrence

    We used a novel, depth-enhanced optical monitoring system to investigate low-frequency hemodynamic oscillations (0.02–0.16 Hz) in cerebral microvascular perfusion, oxygenation, and relative metabolic rate of oxygen in patients with MCI and cognitively intact controls. Our findings indicate cerebrovascular dysfunction in MCI, wherein the regulation of oxygenation is altered to maintain metabolism in an environment with attenuated vascular control. These findings highlight the potential of using optical technology to assess cerebrovascular function in MCI.


  • Blood pressure in human large cerebral arteries: a feasibility study

    by Leena N. Shoemaker, Tyson Matern, Farah Kamar, Keith St Lawrence, Santiago Ortega-Gutierrez, Mario Zanaty, J. Kevin Shoemaker

    We explored the feasibility of making direct measures of blood pressure in the large arteries at the base of the brain in humans. Measures were made with an optical sensor positioned in the aorta, common carotid, internal carotid artery external to the cranium, internal carotid artery within the cranium, and/or middle cerebral artery (MCA), M1 segment. Measures varied across individuals, as did the pressure gradient from systemic pressures to those in the MCA.


  • Open Access

    Cerebrovascular compliance during progressive hypotension in patients with autonomic failure

    by Leena N. Shoemaker, Aleena Sajid, Ronald Schondorf, J. Kevin Shoemaker

    We identify a threshold effect for the increase in cerebrovascular compliance (Ci) during progressive hypotension (baseline vs. end-tilt: 86 ± 18 vs. 50 ± 8 mmHg) in individuals with autonomic failure, such that Ci began to increase progressively after pulse pressure fell by 22 ± 6 mmHg and arterial blood pressure fell by 20 ± 11 mmHg.


  • Open Access

    All-optics technique for monitoring absolute cerebral blood flow: validation against magnetic resonance imaging perfusion

    by Leena N. Shoemaker, Saeed Samaei, Graham Deller, Danny J. J. Wang, Daniel Milej, Keith St. Lawrence

    Worldwide, acquired brain injuries—ischemic stroke, severe traumatic brain injury, and subarachnoid hemorrhage—are major killers and extremely resource-demanding in terms of direct healthcare costs and long-term disability.1 Intensive care of patients with life-threatening acquired brain injuries not only saves lives but improves neurological outcomes. A primary focus is preventing delayed cerebral ischemia by treating complications that can impede oxygen delivery to the brain, such as systemic hypotension and elevated intracranial pressure.2 Clinical features related to neurological deficits (e.g., paresis) are used to detect worsening neurological status, but these often manifest after ischemic injury has occurred and are not reliable indicators in patients requiring sedation. Studies using invasive probes capable of quantifying cerebral blood flow (CBF), such as thermal diffusion flowmetry, suggested that CBF monitoring improves outcomes by alerting the intensivist team when CBF falls below ischemic thresholds.3 The invasiveness of such probes has hindered greater adoption and speaks to the need to develop non-invasive alternatives.


  • Rapid changes in cerebrovascular compliance during vasovagal syncope

    by Leena N. Shoemaker, Aleena Sajid, Ronald Schondorf, J. Kevin Shoemaker

    Purpose The compensatory mechanisms supporting cerebral perfusion throughout head-up tilt (HUT) in patients with vasovagal syncope (VVS) remain unclear. We tested the hypothesis that increased cerebrovascular compliance (Ci) and decreased cerebrovascular resistance (CVR) support cerebral blood velocity (CBV) during pre-syncope in VVS. Methods Finger arterial blood pressure (ABP) and right middle cerebral artery blood velocity (CBV) were recorded in 15 individuals diagnosed with VVS (n = 11 female, mean age: 40 ± 16 years, mean body mass index: 24.9 ± 4.0 kg/m2) at supine rest and during HUT (80 degree angle). Individual ABP and CBV waveforms during VVS were input into a modified Windkessel model to calculate Ci and ohmic CVR. Gosling’s pulsatility index (Pi; pulse amplitude/mean CBV) was calculated. Results Diastolic ABP, systolic ABP, mean ABP (72 ± 11 to 51 ± 12 mmHg), and CVR decreased progressively during presyncope (all P ≤ 0.04). As expected, systolic CBV was sustained (all P ≥ 0.29) while diastolic and mean CBV (51 ± 13 to 38 ± 13 mmHg) fell during presyncope (all P ≤ 0.04). Both Ci and Pi increased during presyncope (128 ± 97 and 60 ± 41%, respectively; all P ≤ 0.049) and were positively correlated (R2 = 0.79, P < 0.01). Increased Ci contributed to changes in mean CBV (P < 0.01) but decreased CVR did not (P = 0.28). Conclusions These data provide evidence that Ci increases during presyncope in patients with VVS and is likely involved in the maintenance of systolic CBV during a fall in diastolic CBV. However, this regulation is not sufficient to preserve CBV in the presence of such extreme and progressive reductions in ABP.


  • Open Access

    Assessing changes in regional cerebral hemodynamics in adults with a high-density full-head coverage time-resolved near-infrared spectroscopy device

    by Farah Kamar, Leena N. Shoemaker, Rasa Eskandari, Daniel Milej, Darren Drosdowech, John M. Murkin, Keith St. Lawrence, Jason Chui, Mamadou Diop

    SignificanceCerebral oximeters have the potential to detect abnormal cerebral blood oxygenation to allow for early intervention. However, current commercial systems have two major limitations: (1) spatial coverage of only the frontal region, assuming that surgery-related hemodynamic effects are global and (2) susceptibility to extracerebral signal contamination inherent to continuous-wave near-infrared spectroscopy (NIRS).AimThis work aimed to assess the feasibility of a high-density, time-resolved (tr) NIRS device (Kernel Flow) to monitor regional oxygenation changes across the cerebral cortex during surgery.ApproachThe Flow system was assessed using two protocols. First, digital carotid compression was applied to healthy volunteers to cause a rapid oxygenation decrease across the ipsilateral hemisphere without affecting the contralateral side. Next, the system was used on patients undergoing shoulder surgery to provide continuous monitoring of cerebral oxygenation. In both protocols, the improved depth sensitivity of trNIRS was investigated by applying moment analysis. A dynamic wavelet filtering approach was also developed to remove observed temperature-induced signal drifts.ResultsIn the first protocol (28±5 years; five females, five males), hair significantly impacted regional sensitivity; however, the enhanced depth sensitivity of trNIRS was able to separate brain and scalp responses in the frontal region. Regional sensitivity was improved in the clinical study given the age-related reduction in hair density of the patients (65±15 years; 14 females, 13 males). In five patients who received phenylephrine to treat hypotension, different scalp and brain oxygenation responses were apparent, although no regional differences were observed.ConclusionsThe Kernel Flow has promise as an intraoperative neuromonitoring device. Although regional sensitivity was affected by hair color and density, enhanced depth sensitivity of trNIRS was able to resolve differences in scalp and brain oxygenation responses in both protocols.


  • Open Access

    Characterization of cerebral macro- and microvascular hemodynamics during transient hypotension

    by Leena N. Shoemaker, Daniel Milej, Aleena Sajid, Jigneshkumar Mistry, Keith St Lawrence, J. Kevin Shoemaker

    To characterize the relationship between cerebrovascular patterns within the large middle cerebral artery (MCA) and a downstream microvascular segment, we used a novel combination of transcranial Doppler ultrasound of the MCA and optical monitoring of a downstream microvascular segment, respectively, under conditions of transiently reduced mean arterial pressure (i.e., lower body negative pressure, −80 mmHg). A rapid increase in vessel compliance accompanied the maintenance of MCA blood velocity and downstream microvascular flow.