Yuan Zhao
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Yuan Zhao has a total of 32 co-authors. Here are the top co-authors by number of shared publications:
Huabei Jiang
School of Physical Electronics, University of Electronic Science and Technology of China 1 , Chengdu 611731, China
2 shared publications- Huabei Jiang
Department of Medical Engineering University of South Florida Tampa Florida USA
2 shared publications - Tianqi Shan
Department of Biomedical Engineering University of Florida Gainesville Florida
2 shared publications Zhengyan He
Chongqing Med Univ, Coll Biomed Engn, State Key Lab Ultrasound Med & Engn, Chongqing 400016, Peoples R China
2 shared publications- Zihui Chi
Chongqing Univ. of Posts and Telecommunications (China)
2 shared publications - Augustine Meombe Mbolle
Department of Medical Engineering, University of South Florida, Tampa, FL 33620, United States
1 shared publication
Latest Publications
- 31 January 2023
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 14 (2) , 987-1002
Automatic force-controlled 3D photoacoustic system for human peripheral vascular imaging
Photoacoustic (PA) imaging provides unique advantages in peripheral vascular imaging due to its high sensitivity to hemoglobin. Nevertheless, limitations associated with handheld or mechanical scanning by stepping motor techniques have precluded photoacoustic vascular imaging from advancing to clinical applications. As clinical applications require flexibility, affordability, and portability of imaging equipment, current photoacoustic imaging systems developed for clinical applications usually use dry coupling. However, it inevitably induces uncontrolled contact force between the probe and the skin. Through 2D and 3D experiments, this study proved that contact forces during the scanning could significantly affect the vascular shape, size, and contrast in PA images, due to the morphology and perfusion alterations of the peripheral blood vessels. However, there is no available PA system that can control forces accurately. This study presented an automatic force-controlled 3D PA imaging system based on a six-degree-of-freedom collaborative robot and a six-dimensional force sensor. It is the first PA system that achieves real-time automatic force monitoring and control. This paper's results, for the first time, demonstrated the ability of an automatic force-controlled system to acquire reliable 3D PA images of peripheral blood vessels. This study provides a powerful tool that will advance PA peripheral vascular imaging to clinical applications in the future.
- 31 January 2023
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 14 (2) , 987-1002
Automatic force-controlled 3D photoacoustic system for human peripheral vascular imaging
Photoacoustic (PA) imaging provides unique advantages in peripheral vascular imaging due to its high sensitivity to hemoglobin. Nevertheless, limitations associated with handheld or mechanical scanning by stepping motor techniques have precluded photoacoustic vascular imaging from advancing to clinical applications. As clinical applications require flexibility, affordability, and portability of imaging equipment, current photoacoustic imaging systems developed for clinical applications usually use dry coupling. However, it inevitably induces uncontrolled contact force between the probe and the skin. Through 2D and 3D experiments, this study proved that contact forces during the scanning could significantly affect the vascular shape, size, and contrast in PA images, due to the morphology and perfusion alterations of the peripheral blood vessels. However, there is no available PA system that can control forces accurately. This study presented an automatic force-controlled 3D PA imaging system based on a six-degree-of-freedom collaborative robot and a six-dimensional force sensor. It is the first PA system that achieves real-time automatic force monitoring and control. This paper's results, for the first time, demonstrated the ability of an automatic force-controlled system to acquire reliable 3D PA images of peripheral blood vessels. This study provides a powerful tool that will advance PA peripheral vascular imaging to clinical applications in the future.
- Open Access
- 22 November 2022
- Published by Frontiers Media SA in Frontiers in Physics
- Vol. 10
Registration of photoacoustic tomography vascular images: Comparison and analysis of automatic registration approaches
Image registration is crucial in the clinical application of photoacoustic tomography (PAT) for vascular growth monitoring. Aiming to find an optimized registration scheme for PAT vascular images acquired at different times and with varying imaging conditions, we compared and analyzed different commonly used intensity-based and feature-based automatic registration schemes. To further improve the registration performance, we proposed a new scheme that combines phase correlation with these commonly used intensity-based registration methods and compared their performances. The objective evaluation measures: peak signal-to-noise ratio (PSNR), structural similarity index metric (SSIM), root mean square error (RMSE), and quantitative visual perception (jump percentage P), as well as subjective evaluation using mean opinion score (MOS), were combined to evaluate the registration performance. Results show that the feature-based approaches in this study were not suitable for PAT image registration. And by adding phase correlation as rough registration, the overall registration performance was improved significantly. Among these methods, the proposed scheme of phase correlation combined with mean square error (MSE) similarity measure and regular-step-gradient-descent optimizer provides the best visual effect, accuracy, and efficiency in PAT vascular image registration.
- 22 November 2022
- Published by Frontiers Media SA in Frontiers in Physics
- Vol. 10
Open AccessRegistration of photoacoustic tomography vascular images: Comparison and analysis of automatic registration approaches
Image registration is crucial in the clinical application of photoacoustic tomography (PAT) for vascular growth monitoring. Aiming to find an optimized registration scheme for PAT vascular images acquired at different times and with varying imaging conditions, we compared and analyzed different commonly used intensity-based and feature-based automatic registration schemes. To further improve the registration performance, we proposed a new scheme that combines phase correlation with these commonly used intensity-based registration methods and compared their performances. The objective evaluation measures: peak signal-to-noise ratio (PSNR), structural similarity index metric (SSIM), root mean square error (RMSE), and quantitative visual perception (jump percentage P), as well as subjective evaluation using mean opinion score (MOS), were combined to evaluate the registration performance. Results show that the feature-based approaches in this study were not suitable for PAT image registration. And by adding phase correlation as rough registration, the overall registration performance was improved significantly. Among these methods, the proposed scheme of phase correlation combined with mean square error (MSE) similarity measure and regular-step-gradient-descent optimizer provides the best visual effect, accuracy, and efficiency in PAT vascular image registration.
- Open Access
- 4 January 2022
- Published by Springer Nature in Egyptian Journal of Radiology and Nuclear Medicine
- Vol. 53 (1) , 1-9
The value of inflow inversion recovery MRI for the diagnosis of transplant renal artery stenosis: comparison with digital subtraction angiography
Background: To date, few data on the assessment of transplant renal artery stenosis (TRAS) by using inflow inversion recovery (IFIR) are available. The aims of this study was to evaluate the feasibility of IFIR in the assessment of TRAS using Digital Subtraction Angiography (DSA) as the reference. Results: We retrospectively assessed the IFIR of 195 transplant renal arteries. The IFIR images for 194/195 arteries were judged to be of excellent, good, or moderate quality, and 1/195 was not diagnostic. There were 100 arteries with TRAS, of which 27 were subjected to DSA. The stenosis percentages were divided into five grades. Using DSA images, the TRAS in 27 patients were estimated as grade 1 (2, 7.4%), grade 2 (8, 29.6%), grade 3 (10, 37.0%), grade 4 (7, 25.9%) and grade 5 (0, 0%). In comparison, the TRAS was shown to be grade 1 (1, 3.7%), grade 2 (8, 29.6%), grade 3 (9, 33.3%), grade 4 (9, 33%) and grade 5 (0, 0%) in the IFIR images. The nonparametric Wilcoxon signed-rank test was used to compare IFIR with DSA. In addition, a Bland–Altman plot was used to estimate the agreement between IFIR and DSA measurements. There was no significant difference between IFIR and DSA measurements (p < 0.05). Conclusions: Relative to the reference DSA, IFIR was shown to be noninvasive, accurate for the diagnosis and evaluation of TRAS.
- 4 January 2022
- Published by Springer Nature in Egyptian Journal of Radiology and Nuclear Medicine
- Vol. 53 (1) , 1-9
Open AccessThe value of inflow inversion recovery MRI for the diagnosis of transplant renal artery stenosis: comparison with digital subtraction angiography
Background: To date, few data on the assessment of transplant renal artery stenosis (TRAS) by using inflow inversion recovery (IFIR) are available. The aims of this study was to evaluate the feasibility of IFIR in the assessment of TRAS using Digital Subtraction Angiography (DSA) as the reference. Results: We retrospectively assessed the IFIR of 195 transplant renal arteries. The IFIR images for 194/195 arteries were judged to be of excellent, good, or moderate quality, and 1/195 was not diagnostic. There were 100 arteries with TRAS, of which 27 were subjected to DSA. The stenosis percentages were divided into five grades. Using DSA images, the TRAS in 27 patients were estimated as grade 1 (2, 7.4%), grade 2 (8, 29.6%), grade 3 (10, 37.0%), grade 4 (7, 25.9%) and grade 5 (0, 0%). In comparison, the TRAS was shown to be grade 1 (1, 3.7%), grade 2 (8, 29.6%), grade 3 (9, 33.3%), grade 4 (9, 33%) and grade 5 (0, 0%) in the IFIR images. The nonparametric Wilcoxon signed-rank test was used to compare IFIR with DSA. In addition, a Bland–Altman plot was used to estimate the agreement between IFIR and DSA measurements. There was no significant difference between IFIR and DSA measurements (p < 0.05). Conclusions: Relative to the reference DSA, IFIR was shown to be noninvasive, accurate for the diagnosis and evaluation of TRAS.
- Open Access
- 1 January 2019
- Published by AIP Publishing in AIP Advances
- Vol. 9 (1) , 015323
Microwave-excited hybrid thermoacoustic and ultrasound imaging with microwave pulse-width modulation
We present a method that allows for hybrid microwave-excited thermoacoustic and ultrasound (HMTAU) imaging without an additional ultrasound transmitting circuitry. The same microwave pulse is used to simultaneously generate thermoacoustic (TA) signals from the sample by the thermoacoustic effect, and ultrasound (US) signals from the piezoelectric transducer by the inverse piezoelectric effect. The same transducer collects the US signals reflected from the sample as a result of the US pulse (pulse-echo) and the TA signals as a result of the sample absorbing microwaves. Experiments are conducted to show how the microwave pulse-width significantly impacts the excitation efficiency of ultrasonic waves, which can reduce the requirement for microwave power. We found that the mechanical response of the US transducer to this transient expansion shows a maximum if the pulse-width of the microwave is close to half of the center period of the US transducer. We also use phantom experiments to demonstrate the complementary contrast mechanisms of the two modalities. The results obtained indicate that our method offers the potential of a low-cost dual-modality technique for noninvasive biomedical imaging.
- 1 January 2019
- Published by AIP Publishing in AIP Advances
- Vol. 9 (1) , 015323
Open AccessMicrowave-excited hybrid thermoacoustic and ultrasound imaging with microwave pulse-width modulation
We present a method that allows for hybrid microwave-excited thermoacoustic and ultrasound (HMTAU) imaging without an additional ultrasound transmitting circuitry. The same microwave pulse is used to simultaneously generate thermoacoustic (TA) signals from the sample by the thermoacoustic effect, and ultrasound (US) signals from the piezoelectric transducer by the inverse piezoelectric effect. The same transducer collects the US signals reflected from the sample as a result of the US pulse (pulse-echo) and the TA signals as a result of the sample absorbing microwaves. Experiments are conducted to show how the microwave pulse-width significantly impacts the excitation efficiency of ultrasonic waves, which can reduce the requirement for microwave power. We found that the mechanical response of the US transducer to this transient expansion shows a maximum if the pulse-width of the microwave is close to half of the center period of the US transducer. We also use phantom experiments to demonstrate the complementary contrast mechanisms of the two modalities. The results obtained indicate that our method offers the potential of a low-cost dual-modality technique for noninvasive biomedical imaging.
- 16 October 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 66 (6) , 1598-1608
Thermoacoustic Tomography of In Vivo Human Finger Joints
Objective: The purpose of this study was to demonstrate the potential of thermoacoustic tomography (TAT) to reveal anatomic structures of in vivo human finger joints. Methods: All the participating volunteers provided written informed consent. Eight healthy middle and index fingers from 5 volunteers were imaged in vivo by our TAT imaging system. Axial T1-weighted MR imaging (3.0T) was used to validate the TAT findings. Comparative analyses between TAT and MRI images were performed in two-dimension for all the fingers imaged. Three-dimensional (3D) images and animations were also obtained for some of the fingers thermoacoustically scanned. Results: Various intra- and extra-articular tissues were identified in TAT images in high fidelity. These TAT images matched well with the MRI images. Both the 3D images and animations effectively displayed the extension and transformation of the entire finger along the axis. Conclusion: TAT can noninvasively visualize anatomic structures of the finger joints based on the electrical properties of the joint tissues. The results obtained indicate that TAT may have the potential to contribute to the detection of joint and bone diseases. Significance: This study represents the first for TAT of in vivo human joints and fingers. This study reveals that TAT can effectively recover both soft and hard tissues of the healthy interphalangeal joints, which provides a foundation for its clinical application to detection and diagnosis of joint and bone diseases.
- 16 October 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 66 (6) , 1598-1608
Thermoacoustic Tomography of In Vivo Human Finger Joints
Objective: The purpose of this study was to demonstrate the potential of thermoacoustic tomography (TAT) to reveal anatomic structures of in vivo human finger joints. Methods: All the participating volunteers provided written informed consent. Eight healthy middle and index fingers from 5 volunteers were imaged in vivo by our TAT imaging system. Axial T1-weighted MR imaging (3.0T) was used to validate the TAT findings. Comparative analyses between TAT and MRI images were performed in two-dimension for all the fingers imaged. Three-dimensional (3D) images and animations were also obtained for some of the fingers thermoacoustically scanned. Results: Various intra- and extra-articular tissues were identified in TAT images in high fidelity. These TAT images matched well with the MRI images. Both the 3D images and animations effectively displayed the extension and transformation of the entire finger along the axis. Conclusion: TAT can noninvasively visualize anatomic structures of the finger joints based on the electrical properties of the joint tissues. The results obtained indicate that TAT may have the potential to contribute to the detection of joint and bone diseases. Significance: This study represents the first for TAT of in vivo human joints and fingers. This study reveals that TAT can effectively recover both soft and hard tissues of the healthy interphalangeal joints, which provides a foundation for its clinical application to detection and diagnosis of joint and bone diseases.
- Open Access
- 16 May 2017
- Published by World Scientific Pub Co Pte Ltd in Journal of Innovative Optical Health Sciences
- Vol. 10 (04)
Thermoacoustic tomography of in vivo rat brain
- 16 May 2017
- Published by World Scientific Pub Co Pte Ltd in Journal of Innovative Optical Health Sciences
- Vol. 10 (04)
Open AccessThermoacoustic tomography of in vivo rat brain
- Open Access
- 18 July 2016
- Published by World Scientific Pub Co Pte Ltd in Journal of Innovative Optical Health Sciences
- Vol. 09 (05) , 1650015
In vivo tumor detection with combined MR–Photoacoustic-Thermoacoustic imaging
- 18 July 2016
- Published by World Scientific Pub Co Pte Ltd in Journal of Innovative Optical Health Sciences
- Vol. 09 (05) , 1650015
Open AccessIn vivo tumor detection with combined MR–Photoacoustic-Thermoacoustic imaging