KBKai Jakob Brunner

Kai Jakob Brunner

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Kai Jakob Brunner has a total of 554 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Commissioning and operation of a real-time multi-point Thomson scattering evaluation system at Wendelstein 7-X

    by Ameer Mohammed, Jürgen Baldzuhn, Torsten Bluhm, Kai Jakob Brunner, Golo Fuchert, Kenneth Hammond, Florian Krafft, Erik Piehler, Mark de Haas, G L Schmidt, et al.

    A real-time multi-point Thomson scattering (rtMPTS) evaluation system has recently been installed and commissioned at the Wendelstein 7-X (W7-X) stellarator during the 2024 -2025 operational phases. This system has demonstrated successful evaluation of Thomson scattered spectra on millisecond timescales. We discuss initial results from this system, consisting of a comparison of different evaluation techniques, assessment of system evaluation times, and proofof-principle control experiments carried out with the W7-X poloidal correlation reflectometer (PCR) system. This diagnostic represents the first step towards the development of a density profile controller at W7-X, which can be leveraged to support steady-state operation.

  • First use of an InSb crystal for x-ray imaging spectroscopy of highly ionized tungsten in the Wendelstein 7-X stellarator

    by Tomas Gonda, Novimir Pablant, David Maurer, David Ennis, Andreas Langenberg, Thomas Pütterich, Birger Buttenschön, Thomas Wegner, Felix Reimold, Thilo Romba, et al.

    Advances in time and space resolved measurements of highly charged states of tungsten (W) through x-ray imaging spectroscopy have enabled investigation of impurity transport in the Wendelstein 7-X (W7-X) stellarator. The high-resolution x-ray imaging spectrometer (HR-XIS) system on W7-X utilizes the Bragg diffraction properties of a set of multiple crystals to measure a range of impurity emission lines within sections of the 1–7 Å wavelength range, including transitions of W. A new indium antimonide crystal has been installed on the HR-XIS system to allow viewing of the 5.5–6.2 Å region focusing on emissions of W. Consequently, many bright W emission lines from W 40 + to W 47 + were observed in this wavelength range, both in plasmas with injected W and in those with only intrinsic W impurity sources, showing the high sensitivity of the diagnostic. Three W 46 + emissions correspond in wavelength and intensity with calculated photon emissivity coefficients and can be exploited for W transport and concentration applications in plasmas with T e ≳ 2.1 keV. An estimate of the core W density behavior in two separate turbulence-reduced ‘high-performance’ (HP) discharges on W7-X is done using the 5.6893 Å W 46 + line. The n W behavior in HP scenarios can be explained by previous experimental results and neoclassical predictions.

  • Open Access

    Tomographic inversion method to characterize coherent mode activity in the Wendelstein 7-X stellarator

    by C. Büschel, C. Brandt, H. Thomsen, K. Aleynikova, K. Rahbarnia, H. M. Smith, E. V. Hausten, M. C. Kelly, S. Vaz Mendes, K.-J. Brunner, et al.

    A new method is presented for the analysis of coherent mode activity, using tomographic reconstruction of the soft x-ray emissivity of the plasma. The analysis includes the determination of the mode frequency, the poloidal mode number, the radial location, the propagation direction, and the ballooning character. The parameters of a constructed mode are fitted to the line-integrated frequency-filtered soft x-ray signals of the 360 photodiodes installed in the Wendelstein 7-X (W7-X) stellarator. Artificial line-integrated photodiode signals, based on experiment-relevant parameters, are used to explain the workflow of the mode analysis. It is demonstrated that the mode parameters can be successfully reconstructed, even for modes at or near the noise level of the measurements. The method is applied to experimental measurements on W7-X, where strong coherent mode activity has been observed in the frequency space during a phase with a core plasma beta of β0 = 4.8%. The mode analysis indicates an m = 14 ± 2 mode whose characteristics agree with kinetic ballooning modes that can be destabilized at high β.

  • Erratum: “Web apps for profile fitting and power balance analysis at Wendelstein 7-X” [Rev. Sci. Instrum. 95, 093529 (2024)]

    by M. Wappl, S. A. Bozhenkov, M. N. A. Beurskens, S. Bannmann, M. D. Kuczyński, H. M. Smith, K. J. Brunner, O. P. Ford, G. Fuchert, J. P. Knauer, et al.

  • Open Access

    Routes to high-performance operation in Wendelstein 7-X: turbulence suppression with shaping of the density profile.

    by Sergey A Bozhenkov, Oliver Patrick Ford, Markus Wappl, Sebastian Bannmann, Thilo Romba, Valeria Perseo, Ksenia Aleynikova, Daihong Zhang, I Amri, Jan-Peter Bäehner, et al.

    Steep density gradients generally lead to improved plasma performance in the neoclassically optimized stellarator W7-X. This is evident in the global energy confinement time as well as in the ion temperature and can be explained by a strong reduction of the ion temperature gradient turbulence. Such conditions can experimentally be realized by several methods: injection of cryogenic hydrogen pellets, appropriate combination of neutral beam and electron cyclotron resonance heating and, in some cases, with low power of electron cyclotron resonance heating after preconditioning of the first wall. The duration of the improved phases is determined by the ability to sustain the steep density gradient, by technical limitations of the involved systems and, eventually, by the plasma stability. This paper gives an overview of relevant experimental results and presents example discharges where the improved confinement conditions could be extended to multiple seconds: up to 4 s using neutral beam injection and from 14 to 40 s with steady state pellet injection. In these plasmas the turbulent thermal diffusivity is reduced by a factor of 3 to 4 in a broad radial range, which allows high ion temperatures of up to 3 keV at the densities of about 1.5 • 10 20 m -3 .


  • Open Access

    Design and experimental verification of a multi-pass ECRH plasma start-up scenario at a reduced magnetic field of 1.8T at W7-X

    by Niklas Simon Polei, Torsten Stange, Kai Jakob Brunner, Olaf Grulke, Juan Fernando Guerrero Arnaiz, Laurent Krier, Heinrich Laqua, Stefan Marsen, Dmitry Moseev, Burkhard Plaum, et al.

    Wendelstein 7-X (W7-X) nominally operates at a magnetic field of 2.5T, but operation at a lower magnetic field strength is desired. The electron cyclotron resonance heating (ECRH) system of W7-X operates at 140GHz, corresponding to second harmonic (X2) heating at 2.5T, but also allows for heating at the third harmonic with a vacuum magnetic field around 1.7T to 1.8T. However, plasma start-up is not possible with X3-heating. Therefore one of the gyrotrons was tuned down to 101GHz for an X2 breakdown of the plasma at 1.8T on the magnetic axis. The available power in the plasma vessel for this detuned gyrotron is only 250kW with a pulse length of the order of 50ms. For this reason a multi-pass scenario was designed with six passes close to the magnetic axis to increase the effective power in the first few milliseconds during the breakdown. During the short 101GHz gyrotron pulse, this X2 multi-pass scenario creates a small plasma with temperatures up to several keV and line integrated densities around 8*10^18m^-2. It could also be shown that the multi-pass scenario is necessary to achieve plasma breakdown within 50ms. The plasma can be taken over by two sources of the neutral beam injection (NBI), starting at the same time as the detuned gyrotron to increase temperature and density. After about 1.5s at least 3MW of X3 ECRH are needed to take over from the NBI to maintain a stable plasma. This enables the low field operation of W7-X.

  • Open Access

    A fast helium beam diagnostic at the island divertor of W7-X for the investigation of plasma edge dynamics

    by Sebastian Josef Hörmann, Michael Griener, Maciej Krychowiak, Dorothea Gradic, Foisal Siddiki, Miguel Astrain, Erik Flom, Gregor Birkenmeier, Adrian von Stechow, Carsten Killer, et al.

    Understanding and quantifying particle and energy transport at the plasma edge region is crucial for magnetic confinement fusion. For this purpose, a new polychromator system with 1 µs time resolution was installed for the thermal helium beam diagnostic in the island divertor of the stellarator W7-X. The time resolution is four orders of magnitude faster than the spectrometer-based system. This allows for the first time access to turbulence-relevant time scales, enabling the investigation of plasma edge dynamics such as modes and instabilities. Their connection to averaged plasma profiles is likewise accessible with this diagnostic. Furthermore, the diagnostic system measures in two magnetically connected divertors, which enables the study of long-range correlation of fluctuations. Utilising a collisional-radiative model, the diagnostic can reconstruct fast electron density and temperature variations with an effective resolution of 10 kHz, associated with plasma modes and bursts. Additionally, it provides high temporal resolution measurements of the detachment process in the divertor. Since it simultaneously measures at an upper and lower divertor, it is the first edge diagnostic at W7-X capable of measuring the up-down asymmetry of turbulence. This article presents the design and implementation of the diagnostic as well as an analysis of the signal quality. It also looks at the influence of diagnostic gas puffs on the plasma in detail. To present the potential of the diagnostic, this work briefly shows a long-range correlation analysis of an edge mode between two divertors that are magnetically connected as well as the electron temperature and density calculation for this mode. Furthermore, a detachment process measured with high time resolution is presented.

  • Open Access

    Core plasma fueling by fast inward particle transport after hydrogen pellet injection in Wendelstein 7-X

    by H. Damm, J. Baldzuhn, R.C. Wolf, T.S. Petersen, J. Schilling, N. Panadero, S.A. Bozhenkov, C. Brandt, K.J. Brunner, G. Fuchert, et al.

    A large database of more than 1000 individual cryogenic hydrogen pellets injected into Wendelstein 7-X for plasma fueling was analyzed to improve the understanding of the three phases of the process: the ablation, deposition and transport of the pellet material. Kilohertz-sampled electron density and temperature measurements revealed a more complex drift behavior than predicted by numerical code simulation. It could be explained by the poloidal plasma E r × B - drift rotation, which plays a significant role in stellarators, but was not previously considered in pellet injection codes like HPI2. The drift results in a fast poloidal rotation of the pellet material around the plasma core, leading to an almost homogeneous deposition over the involved flux surfaces regardless of magnetic high and low field side injection geometry. Additionally, a novel fast inward directed transport mechanism (‘FIT-effect’) was observed. The effect occurs on timescales of tens of milliseconds and cannot be explained by neoclassical transport or diffusion. It might be linked to the turbulence pinch recently found in Wendelstein 7-X. When the FIT-effect occurs, the pellet particles are rapidly transferred from the deposition flux surfaces to the plasma core, causing the plasma density profile to peak, which is beneficial for confinement in Wendelstein 7-X. The large pellet injection database was statistical analyzed with regard to pellet and plasma parameters, which delivered some starting points towards developing an understanding of the physics behind the FIT-effect. The results indicate, that plasma core fueling via pellet injection is largely independent of the injection geometry in stellarators under certain conditions, reducing the technical complexity of the injection system.

  • Open Access

    In-situ spectral calibration from plasma measurements of the W7-X Thomson scattering diagnostic

    by Golo Fuchert, Alina Raak, Jannik Wagner, Robert Wolf, Sergey A Bozhenkov, Kai Jakob Brunner, Jens P Knauer, Ekkehard Pasch, Matthias Hirsch

    The quality of Thomson scattering (TS) profiles relies on high-quality calibrations since each spatial point is essentially an independent measurement. For the spectral calibration of TS diagnostics, several different techniques exist. Typically, these include a known light source and involve changes to the optical setup to observe that light source. Two assumptions are frequently made: The spectral response of the diagnostic is stable in time and the required changes to the optical setup only lead to negligible errors in the calibration. The temporal stability is questionable for larger fusion experiments, where the harsh environment leads to coating and degradation of optical components. Both the stability and validity of the spectral calibration can be checked by in-situ calibrations. Here, the calibration is performed either during operation or in between experiments without any modifications to the diagnostic. So far, two promising candidates have been proposed: dual-wavelength Thomson scattering and Rayleigh scattering on, for example, argon gas using a tunable OPO (optical parametric oscillator). In this contribution, we introduce a new method for an in-situ spectral calibration using experimental data from plasma measurements. This method was developed for polychromator-based TS diagnostics, but can probably also be adapted to spectrometer-based systems. A forward model is used to predict the signals measured by the diagnostic (assuming a certain spectral calibration) and these predictions are then compared with experimental data the diagnostic has acquired. Using an optimizer, the spectral calibration is varied until predicted and measured data agree. Rough knowledge of the polychromator design is sufficient to find an estimate for the calibration of the diagnostic. We demonstrate, using polychromators from Wendelstein 7-X as example, that even data measured in the past can be calibrated with this technique.

  • Open Access

    Auto-encoding quadrature components of modulated dispersion interferometers

    by K J Brunner, G Fuchert, F B L de Amorim Resende, J Knauer, M Hirsch, R C Wolf, the W7-X Team

    Phase-modulated dispersion interferometry is an increasingly popular method of measuring the line-integrated electron density in magnetic confinement fusion devices due to its inherent vibration compensation in combination with the high resilience to rapid density changes. At present, two quadrature methods of extracting the phase from a temporal interferogram of a phase modulated DI are known, both of which have been shown to exhibit strong phase nonlinearities, which could be prohibitively large in fusion reactor size devices (Brunner et al 2022 Rev. Sci. Instrum. 93 023506). These errors are not fixed and hence, i.e. they change over the course of the day, which makes static compensation schemes difficult. In this work we present a neural network based approach to extract the phase information from a temporal dispersion interferogram using a mathematically regulated auto-encoder. No assumptions are being made on the underlying physics/optics of the data avoiding training the network with false assumptions. The training approach also avoids the common concern of extrapolation entirely, i.e. how does the network behave when it sees unseen data. We also show that the network can be trained without using plasma data. The network is shown to extract quadrature components from the interferogram with significantly reduced systematic quadrature distortions as well as lower noise and higher bandwidth than the currently established methods. It is also shown to effectively reduce the nonlinearity drifts occurring, when trained on larger datasets. The method presented here is not limited to dispersion interferometers, but should be applicable to any quadrature component based phase measurement, e.g. radiometry, reflectometry, radar or digital radio.