Jun-Ichi Nishimura
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Jun-Ichi Nishimura has a total of 40 co-authors. Here are the top co-authors by number of shared publications:
Soichiro Hase
Department of Interventional Radiology, Kawasaki Saiwai Hospital, 31-27, Omiya-Cho, Saiwai-Ku, Kawasaki, Kanagawa, 212-0014 Japan
3 shared publications- Yuya Koike
Department of Cardiovascular Surgery, Nihon University School of Medicine, Itabashi-ku, Tokyo, Japan
3 shared publications Motoshige Yamasaki
Department of Interventional Radiology, Kawasaki Saiwai Hospital, 31-27, Omiya-Cho, Saiwai-Ku, Kawasaki, Kanagawa, 212-0014 Japan
2 shared publicationsNobukazu Moriya
Department of Interventional Radiology, Kawasaki Saiwai Hospital, 31-27, Omiya-cho, Saiwai-Ku, Kawasaki, Kanagawa, 212-0014, Japan
2 shared publicationsAkinori Harada
Department of Interventional Radiology, Japanese Red Cross Medical Center
1 shared publicationAkira Sato
Yokohama Municipal Citizen’s Hospital
1 shared publication
Latest Publications
- Open Access
- 12 January 2022
- Published by The Japanese Society of Interventional Radiology in Interventional Radiology
- Vol. 7 (1) , 26-29
Two Case Studies on Inferior Mesenteric Artery Embolization for Primary Postpartum Hemorrhage
Postpartum hemorrhage (PPH) remains a leading cause of maternal mortality. Transcatheter arterial embolization (TAE) is an effective treatment option for PPH. Among the vessels embolized, the inferior mesenteric artery (IMA) is usually not the first choice for TAE, because it is a rare source of bleeding in PPH. In this report, we describe our experience with two patients with PPH, in whom the IMA was selected on the basis of contrast-enhanced computed tomography (CECT) findings, and prompt hemostasis was achieved with TAE. CECT can provide useful clues as to the culprit artery based on the anatomical location of the hematoma and extravasation. These useful findings of CECT allow prompt TAE of rare sources of bleeding in PPH, such as the IMA.
- 12 January 2022
- Published by The Japanese Society of Interventional Radiology in Interventional Radiology
- Vol. 7 (1) , 26-29
Open AccessTwo Case Studies on Inferior Mesenteric Artery Embolization for Primary Postpartum Hemorrhage
Postpartum hemorrhage (PPH) remains a leading cause of maternal mortality. Transcatheter arterial embolization (TAE) is an effective treatment option for PPH. Among the vessels embolized, the inferior mesenteric artery (IMA) is usually not the first choice for TAE, because it is a rare source of bleeding in PPH. In this report, we describe our experience with two patients with PPH, in whom the IMA was selected on the basis of contrast-enhanced computed tomography (CECT) findings, and prompt hemostasis was achieved with TAE. CECT can provide useful clues as to the culprit artery based on the anatomical location of the hematoma and extravasation. These useful findings of CECT allow prompt TAE of rare sources of bleeding in PPH, such as the IMA.
- Open Access
- 28 January 2016
- Published by Oxford University Press (OUP) in Journal of Radiation Research
- Vol. 57 (2) , 174-177
Percutaneous fiducial marker placement prior to stereotactic body radiotherapy for malignant liver tumors: an initial experience
The aim of this study was to describe our initial experience with a gold flexible linear fiducial marker and to evaluate the safety and technical and clinical efficacy of stereotactic body radiotherapy using this marker for malignant liver tumors. Between July 2012 and February 2015, 18 patients underwent percutaneous fiducial marker placement before stereotactic body radiotherapy for malignant liver tumors. We evaluated the technical and clinical success rates of the procedure and the associated complications. Technical success was defined as successful placement of the fiducial marker at the target site, and clinical success was defined as the completion of stereotactic body radiotherapy without the marker dropping out of position. All 18 fiducial markers were placed successfully, so the technical success rate was 100% (18/18). All 18 patients were able to undergo stereotactic body radiotherapy without marker migration. Thus, the clinical success rate was 100% (18/18). Slight pneumothorax occurred as a minor complication in one case. No major complications such as coil migration or bleeding were observed. The examined percutaneous fiducial marker was safely placed in the liver and appeared to be useful for stereotactic body radiotherapy for malignant liver tumors.
- 28 January 2016
- Published by Oxford University Press (OUP) in Journal of Radiation Research
- Vol. 57 (2) , 174-177
Open AccessPercutaneous fiducial marker placement prior to stereotactic body radiotherapy for malignant liver tumors: an initial experience
The aim of this study was to describe our initial experience with a gold flexible linear fiducial marker and to evaluate the safety and technical and clinical efficacy of stereotactic body radiotherapy using this marker for malignant liver tumors. Between July 2012 and February 2015, 18 patients underwent percutaneous fiducial marker placement before stereotactic body radiotherapy for malignant liver tumors. We evaluated the technical and clinical success rates of the procedure and the associated complications. Technical success was defined as successful placement of the fiducial marker at the target site, and clinical success was defined as the completion of stereotactic body radiotherapy without the marker dropping out of position. All 18 fiducial markers were placed successfully, so the technical success rate was 100% (18/18). All 18 patients were able to undergo stereotactic body radiotherapy without marker migration. Thus, the clinical success rate was 100% (18/18). Slight pneumothorax occurred as a minor complication in one case. No major complications such as coil migration or bleeding were observed. The examined percutaneous fiducial marker was safely placed in the liver and appeared to be useful for stereotactic body radiotherapy for malignant liver tumors.
- 1 August 2014
- Published by Elsevier in Journal of Vascular and Interventional Radiology
- Vol. 25 (8) , 1172-1180.e1
Dynamic Volumetric CT Angiography for the Detection and Classification of Endoleaks: Application of Cine Imaging Using a 320-Row CT Scanner with 16-cm Detectors
- 1 August 2014
- Published by Elsevier in Journal of Vascular and Interventional Radiology
- Vol. 25 (8) , 1172-1180.e1
Dynamic Volumetric CT Angiography for the Detection and Classification of Endoleaks: Application of Cine Imaging Using a 320-Row CT Scanner with 16-cm Detectors
- 22 March 2014
- Published by Springer Nature in General Thoracic and Cardiovascular Surgery
- Vol. 63 (12) , 667-669
Successful treatment of refractory chylothorax by pedicled omentoplasty
- 22 March 2014
- Published by Springer Nature in General Thoracic and Cardiovascular Surgery
- Vol. 63 (12) , 667-669
Successful treatment of refractory chylothorax by pedicled omentoplasty
- 14 March 2014
- Published by Springer Nature in CardioVascular and Interventional Radiology
- Vol. 38 (2) , 457-462
Sac Angiography and Glue Embolization in Emergency Endovascular Aneurysm Repair for Ruptured Abdominal Aortic Aneurysm
- 14 March 2014
- Published by Springer Nature in CardioVascular and Interventional Radiology
- Vol. 38 (2) , 457-462
Sac Angiography and Glue Embolization in Emergency Endovascular Aneurysm Repair for Ruptured Abdominal Aortic Aneurysm
- 28 June 2013
- Published by Elsevier in Journal of Vascular and Interventional Radiology
- Vol. 24 (10) , 1462-1469
Use of the Endurant Stent Graft System for Ruptured Infrarenal Aortic Aneurysms: Short-term Experience in Nine Patients
- 28 June 2013
- Published by Elsevier in Journal of Vascular and Interventional Radiology
- Vol. 24 (10) , 1462-1469
Use of the Endurant Stent Graft System for Ruptured Infrarenal Aortic Aneurysms: Short-term Experience in Nine Patients
- 1 January 2013
- Published by Elsevier in Journal of Vascular and Interventional Radiology
- Vol. 24 (1) , 135-137
Percutaneous Transvenous Embolization of the Thoracic Duct in the Treatment of Chylothorax in Two Patients
- 1 January 2013
- Published by Elsevier in Journal of Vascular and Interventional Radiology
- Vol. 24 (1) , 135-137
Percutaneous Transvenous Embolization of the Thoracic Duct in the Treatment of Chylothorax in Two Patients
- Open Access
- 26 November 2009
- Published by American Society of Neuroradiology (ASNR) in American Journal of Neuroradiology
- Vol. 31 (4) , 620-625
Effect of Tube Voltage on Image Quality in 64-Section Multidetector 3D CT Angiography: Evaluation with a Vascular Phantom with Superimposed Bone Skull Structures
BACKGROUND AND PURPOSE: Optimal tube voltage and tube current settings are not well established. The purpose of our study was to investigate the image quality on 3D CT angiograms of the brain at various kilovoltage settings by evaluating the depiction of simulated intracranial lesions by using a vascular phantom. MATERIALS AND METHODS: An anthropomorphic vascular phantom with superimposed bone skull structures was designed to simulate various intracranial aneurysms with aneurysmal blebs. We performed CT angiography by using a 64-detector row CT scanner for various effective tube currents with 4 tube voltages of 80, 100, 120, and 135 kV(p). Simulated aneurysm enhancement and image noise were quantified; SNR and CNR were calculated. The depiction of the simulated aneurysms and blebs on 3D CT angiograms obtained with the volume-rendering technique was subjectively assessed. The effective dose was calculated on the basis of a CTDIw. The results of several protocols were compared by using the Student t test. RESULTS: At identical doses levels (CTDIw), the mean SNR and CNR at 100 kV(p) were significantly higher than those at 80, 120, and 135 kV(p); and the mean qualitative image score at 100 kV(p) was significantly superior to those at 80 and 135 kV(p). CONCLUSIONS: Our phantom study suggests that the tube voltage of 100 kV(p) is desirable for cerebral 3D CT angiograms, and the higher or lower kilovoltage settings may result in the degradation in diagnostic image quality.
- 26 November 2009
- Published by American Society of Neuroradiology (ASNR) in American Journal of Neuroradiology
- Vol. 31 (4) , 620-625
Open AccessEffect of Tube Voltage on Image Quality in 64-Section Multidetector 3D CT Angiography: Evaluation with a Vascular Phantom with Superimposed Bone Skull Structures
BACKGROUND AND PURPOSE: Optimal tube voltage and tube current settings are not well established. The purpose of our study was to investigate the image quality on 3D CT angiograms of the brain at various kilovoltage settings by evaluating the depiction of simulated intracranial lesions by using a vascular phantom. MATERIALS AND METHODS: An anthropomorphic vascular phantom with superimposed bone skull structures was designed to simulate various intracranial aneurysms with aneurysmal blebs. We performed CT angiography by using a 64-detector row CT scanner for various effective tube currents with 4 tube voltages of 80, 100, 120, and 135 kV(p). Simulated aneurysm enhancement and image noise were quantified; SNR and CNR were calculated. The depiction of the simulated aneurysms and blebs on 3D CT angiograms obtained with the volume-rendering technique was subjectively assessed. The effective dose was calculated on the basis of a CTDIw. The results of several protocols were compared by using the Student t test. RESULTS: At identical doses levels (CTDIw), the mean SNR and CNR at 100 kV(p) were significantly higher than those at 80, 120, and 135 kV(p); and the mean qualitative image score at 100 kV(p) was significantly superior to those at 80 and 135 kV(p). CONCLUSIONS: Our phantom study suggests that the tube voltage of 100 kV(p) is desirable for cerebral 3D CT angiograms, and the higher or lower kilovoltage settings may result in the degradation in diagnostic image quality.