ODOleksandr P. Dzyubak

Oleksandr P. Dzyubak

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Oleksandr P. Dzyubak has a total of 732 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Evaluation of tumor localization in respiration motion‐corrected cone‐beam CT: Prospective study in lung

    by Oleksandr Dzyubak, Russell Kincaid, Agung Hertanto, Yu‐Chi Hu, Hai Pham, Andreas Rimner, Ellen Yorke, Qinghui Zhang, Gig S. Mageras

    Purpose:: Target localization accuracy of cone‐beam CT (CBCT) images used in radiation treatment of respiratory disease sites is affected by motion artifacts (blurring and streaking). The authors have previously reported on a method of respiratory motion correction in thoracic CBCT at end expiration (EE). The previous retrospective study was limited to examination of reducing motion artifacts in a small number of patient cases. They report here on a prospective study in a larger group of lung cancer patients to evaluate respiratory motion‐corrected (RMC)‐CBCT ability to improve lung tumor localization accuracy and reduce motion artifacts in Linac‐mounted CBCT images. A second study goal examines whether the motion correction derived from a respiration‐correlated CT (RCCT) at simulation yields similar tumor localization accuracy at treatment.Methods:: In an IRB‐approved study, 19 lung cancer patients (22 tumors) received a RCCT at simulation, and on one treatment day received a RCCT, a respiratory‐gated CBCT at end expiration, and a 1‐min CBCT. A respiration monitor of abdominal displacement was used during all scans. In addition to a CBCT reconstruction without motion correction, the motion correction method was applied to the same 1‐min scan. Projection images were sorted into ten bins based on abdominal displacement, and each bin was reconstructed to produce ten intermediate CBCT images. Each intermediate CBCT was deformed to the end expiration state using a motion model derived from RCCT. The deformed intermediate CBCT images were then added to produce a final RMC‐CBCT. In order to evaluate the second study goal, the CBCT was corrected in two ways, one using a model derived from the RCCT at simulation [RMC‐CBCT(sim)], the other from the RCCT at treatment [RMC‐CBCT(tx)]. Image evaluation compared uncorrected CBCT, RMC‐CBCT(sim), and RMC‐CBCT(tx). The gated CBCT at end expiration served as the criterion standard for comparison. Using automatic rigid image registration, each CBCT was registered twice to the gated CBCT, first aligned to spine, second to tumor in lung. Localization discrepancy was defined as the difference between tumor and spine registration. Agreement in tumor localization with the gated CBCT was further evaluated by calculating a normalized cross correlation (NCC) of pixel intensities within a volume‐of‐interest enclosing the tumor in lung.Results:: Tumor localization discrepancy was reduced with RMC‐CBCT(tx) in 17 out of 22 cases relative to no correction. If one considers cases in which tumor motion is 5 mm or more in the RCCT, tumor localization discrepancy is reduced with RMC‐CBCT(tx) in 14 out of 17 cases (p = 0.04), and with RMC‐CBCT(sim) in 13 out of 17 cases (p = 0.05). Differences in localization discrepancy between correction models [RMC‐CBCT(sim) vs RMC‐CBCT(tx)] were less than 2 mm. In 21 out of 22 cases, improvement in NCC was higher with RMC‐CBCT(tx) relative to no correction (p < 0.0001). Differences in NCC between RMC‐CBCT(sim) and RMC‐CBCT(tx) were small.Conclusions:: Motion‐corrected CBCT improves lung tumor localization accuracy and reduces motion artifacts in nearly all cases. Motion correction at end expiration using RCCT acquired at simulation yields similar results to that using a RCCT on the treatment day (2–3 weeks after simulation).


  • Reduction of irregular breathing artifacts in respiration‐correlated CT images using a respiratory motion model

    by Agung Hertanto, Qinghui Zhang, Yu‐Chi Hu, Oleksandr Dzyubak, Andreas Rimner, Gig S. Mageras

    Purpose:: Respiration‐correlated CT (RCCT) images produced with commonly used phase‐based sorting of CT slices often exhibit discontinuity artifacts between CT slices, caused by cycle‐to‐cycle amplitude variations in respiration. Sorting based on the displacement of the respiratory signal yields slices at more consistent respiratory motion states and hence reduces artifacts, but missing image data (gaps) may occur. The authors report on the application of a respiratory motion model to produce an RCCT image set with reduced artifacts and without missing data.Methods:: Input data consist of CT slices from a cine CT scan acquired while recording respiration by monitoring abdominal displacement. The model‐based generation of RCCT images consists of four processing steps: (1) displacement‐based sorting of CT slices to form volume images at 10 motion states over the cycle; (2) selection of a reference image without gaps and deformable registration between the reference image and each of the remaining images; (3) generation of the motion model by applying a principal component analysis to establish a relationship between displacement field and respiration signal at each motion state; (4) application of the motion model to deform the reference image into images at the 9 other motion states. Deformable image registration uses a modified fast free‐form algorithm that excludes zero‐intensity voxels, caused by missing data, from the image similarity term in the minimization function. In each iteration of the minimization, the displacement field in the gap regions is linearly interpolated from nearest neighbor nonzero intensity slices. Evaluation of the model‐based RCCT examines three types of image sets: cine scans of a physical phantom programmed to move according to a patient respiratory signal, NURBS‐based cardiac torso (NCAT) software phantom, and patient thoracic scans.Results:: Comparison in physical motion phantom shows that object distortion caused by variable motion amplitude in phase‐based sorting is visibly reduced with model‐based RCCT. Comparison of model‐based RCCT to original NCAT images as ground truth shows best agreement at motion states whose displacement‐sorted images have no missing slices, with mean and maximum discrepancies in lung of 1 and 3 mm, respectively. Larger discrepancies correlate with motion states having a larger number of missing slices in the displacement‐sorted images. Artifacts in patient images at different motion states are also reduced. Comparison with displacement‐sorted patient images as a ground truth shows that the model‐based images closely reproduce the ground truth geometry at different motion states.Conclusions:: Results in phantom and patient images indicate that the proposed method can produce RCCT image sets with reduced artifacts relative to phase‐sorted images, without the gaps inherent in displacement‐sorted images. The method requires a reference image at one motion state that has no missing data. Highly irregular breathing patterns can affect the method's performance, by introducing artifacts in the reference image (although reduced relative to phase‐sorted images), or in decreased accuracy in the image prediction of motion states containing large regions of missing data.


  • Open Access

    Automation of Hessian-Based Tubularity Measure Response Function in 3D Biomedical Images

    by Oleksandr P. Dzyubak, Erik L. Ritman

    The blood vessels and nerve trees consist of tubular objects interconnected into a complex tree- or web-like structure that has a range of structural scale 5 μm diameter capillaries to 3 cm aorta. This large-scale range presents two major problems; one is just making the measurements, and the other is the exponential increase of component numbers with decreasing scale. With the remarkable increase in the volume imaged by, and resolution of, modern day 3D imagers, it is almost impossible to make manual tracking of the complex multiscale parameters from those large image data sets. In addition, the manual tracking is quite subjective and unreliable. We propose a solution for automation of an adaptive nonsupervised system for tracking tubular objects based on multiscale framework and use of Hessian-based object shape detector incorporating National Library of Medicine Insight Segmentation and Registration Toolkit (ITK) image processing libraries.


  • Evidence for a backward peak in the γd → π0d cross section near the η threshold

    by The CLAS Collaboration, Y. Ilieva, B. L. Berman, A. E. Kudryavtsev, I. I. Strakovsky, V. E. Tarasov, M. Amarian, P. Ambrozewicz, M. Anghinolfi, G. Asryan, et al.


  • Beam spin asymmetries in deeply virtual Compton scattering (DVCS) with CLAS at 4.8 GeV

    by G. Gavalian, V. D. Burkert, L. Elouadrhiri, M. Holtrop, S. Stepanyan, D. Abrahamyan, G. Adams, M. J. Amaryan, P. Ambrozewicz, M. Anghinolfi, et al.

    We report measurements of the beam spin asymmetry in deeply virtual Compton scattering (DVCS) at an electron beam energy of 4.8 GeV using the CLAS detector at the Thomas Jefferson National Accelerator Facility. The DVCS beam spin asymmetry has been measured in a wide range of kinematics, 1.0<Q2<2.8 (GeV/c)2, 0.12<xB<0.48, and 0.1<−t<0.8 (GeV/c)2, using the reaction e→p→e'pX. The number of H(e,e'γp) and H(e,e'π0p) events are separated in each (Q2,xB,t) bin by a fit to the line shape of the H(e,e'p)X Mx2 distribution. The validity of the method was studied in detail using experimental and simulated data. It was shown that with the achieved missing mass squared resolution and the available statistics, the separation of DVCS–Bethe-Heitler and π0 events can reliably be done with less than 5% uncertainty. Also, the Q2 and t dependences of the sinϕ moments of the asymmetry are extracted and compared with theoretical calculations.


  • Measurement of semi-inclusiveπ+electroproduction off the proton

    by M. Osipenko, M. Ripani, G. Ricco, H. Avakian, R. De Vita, G. Adams, M. J. Amaryan, P. Ambrozewicz, M. Anghinolfi, G. Asryan, et al.

    Semi-inclusive π+ electroproduction on protons has been measured with the CLAS detector at Jefferson Lab. The measurement was performed on a liquid-hydrogen target using a 5.75 GeV electron beam. The complete five-fold differential cross sections were measured over a wide kinematic range including the complete range of azimuthal angles between hadronic and leptonic planes, ϕ, enabling us to separate the ϕ-dependent terms. Our measurements of the ϕ-independent term of the cross section at low Bjorken x were found to be in fairly good agreement with pQCD calculations. Indeed, the conventional current fragmentation calculation can account for almost all of the observed cross section, even at small π+ momentum. The measured center-of-momentum spectra are in qualitative agreement with high-energy data, which suggests a surprising numerical similarity between the spectator diquark fragmentation in the present reaction and the antiquark fragmentation measured in e+e− collisions. We have observed that the two ϕ-dependent terms of the cross section are small. Within our precision the cos2ϕ term is compatible with zero, except for the low-z region, and the measured cosϕ term is much smaller in magnitude than the sum of the Cahn and Berger effects.


  • Precise Measurement of the Neutron Magnetic Form FactorGMnin the Few-GeV2Region

    by J. Lachniet, A. Afanasev, H. Arenhövel, W. K. Brooks, G. P. Gilfoyle, D. Higinbotham, S. Jeschonnek, B. Quinn, M. F. Vineyard, G. Adams, et al.

    The neutron elastic magnetic form factor was extracted from quasielastic electron scattering on deuterium over the range Q2=1.0–4.8  GeV2 with the CLAS detector at Jefferson Lab. High precision was achieved with a ratio technique and a simultaneous in situ calibration of the neutron detection efficiency. Neutrons were detected with electromagnetic calorimeters and time-of-flight scintillators at two beam energies. The dipole parametrization gives a good description of the data.


  • Search for the Photoexcitation of Exotic Mesons in theπ+π+π−System

    by M. Nozar, C. Salgado, D. P. Weygand, L. Guo, G. Adams, Ji Li, P. Eugenio, M. J. Amaryan, M. Anghinolfi, G. Asryan, et al.

    A search for exotic mesons in the π+π+π− system photoproduced by the charge exchange reaction γp→π+π+π−(n) was carried out by the CLAS Collaboration at Jefferson Lab. A tagged-photon beam with energies in the 4.8 to 5.4 GeV range, produced through bremsstrahlung from a 5.744 GeV electron beam, was incident on a liquid-hydrogen target. A partial wave analysis was performed on a sample of 83 000 events, the highest such statistics to date in this reaction at these energies. The main objective of this study was to look for the photoproduction of an exotic JPC=1−+ resonant state in the 1 to 2 GeV mass range. Our partial wave analysis shows production of the a2(1320) and the π2(1670) mesons, but no evidence for the a1(1260), nor the π1(1600) exotic state at the expected levels. An upper limit of 13.5 nb is determined for the exotic π1(1600) cross section, less than 2% of the a2(1320) production.


  • Measurement of Directf0(980)Photoproduction on the Proton

    by M. Battaglieri, R. De Vita, A. P. Szczepaniak, K. P. Adhikari, M. Aghasyan, M. J. Amaryan, P. Ambrozewicz, M. Anghinolfi, G. Asryan, H. Avakian, et al.

    We report on the results of the first measurement of exclusive f0(980) meson photoproduction on protons for Eγ=3.0–3.8  GeV and −t=0.4–1.0  GeV2. Data were collected with the CLAS detector at the Thomas Jefferson National Accelerator Facility. The resonance was detected via its decay in the π+π− channel by performing a partial wave analysis of the reaction γp→pπ+π−. Clear evidence of the f0(980) meson was found in the interference between P and S waves at Mπ+π−∼1  GeV. The S-wave differential cross section integrated in the mass range of the f0(980) was found to be a factor of about 50 smaller than the cross section for the ρ meson. This is the first time the f0(980) meson has been measured in a photoproduction experiment.