Chiara Corsini
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Chiara Corsini has a total of 55 co-authors. Here are the top co-authors by number of shared publications:
- Giancarlo Pennati
Politecnico di Milano
15 shared publications - Francesco Migliavacca
Politecnico di Milano
13 shared publications Tain-Yen Hsia
UCL Institute of Cardiovascular Science and Great Ormond Street Hospital for Children, NHS Foundation Trust, London, UK
13 shared publications- Gabriele Dubini
Laboratory of Biological Structure Mechanics (LaBS), Department of Chemistry, Materials and Chemical Engineering “Giulio Natta”, Politecnico di Milano, Milan, Italy
9 shared publications - Alison Lesley Marsden
Institute for Computational and Mathematical Engineering, Stanford University, Stanford, USA
7 shared publications - Irene E. Vignon-Clementel
Inria, Research Center Raoul Sallé de Chou Hugues Talbot Saclay Ile-de-France Irene Vignon-Clementel France
6 shared publications
Latest Publications
- 8 July 2017
- Published by IOP Publishing in Medical Engineering & Physics
- Vol. 47 (1) , 55-63
Mathematical modelling of the maternal cardiovascular system in the three stages of pregnancy
In this study, a mathematical model of the female circulation during pregnancy is presented in order to investigate the hemodynamic response to the cardiovascular changes associated with each trimester of pregnancy. First, a preliminary lumped parameter model of the circulation of a non-pregnant female was developed, including the heart, the systemic circulation with a specific block for the uterine district and the pulmonary circulation. The model was first tested at rest; then heart rate and vascular resistances were individually varied to verify the correct response to parameter alterations characterising pregnancy. In order to simulate hemodynamics during pregnancy at each trimester, the main changes applied to the model consisted in reducing vascular resistances, and simultaneously increasing heart rate and ventricular wall volumes. Overall, reasonable agreement was found between model outputs and in vivo data, with the trends of the cardiac hemodynamic quantities suggesting correct response of the heart model throughout pregnancy. Results were reported for uterine hemodynamics, with flow tracings resembling typical Doppler velocity waveforms at each stage, including pulsatility indexes. Such a model may be used to explore the changes that happen during pregnancy in female with cardiovascular diseases.
- 8 July 2017
- Published by IOP Publishing in Medical Engineering & Physics
- Vol. 47 (1) , 55-63
Mathematical modelling of the maternal cardiovascular system in the three stages of pregnancy
In this study, a mathematical model of the female circulation during pregnancy is presented in order to investigate the hemodynamic response to the cardiovascular changes associated with each trimester of pregnancy. First, a preliminary lumped parameter model of the circulation of a non-pregnant female was developed, including the heart, the systemic circulation with a specific block for the uterine district and the pulmonary circulation. The model was first tested at rest; then heart rate and vascular resistances were individually varied to verify the correct response to parameter alterations characterising pregnancy. In order to simulate hemodynamics during pregnancy at each trimester, the main changes applied to the model consisted in reducing vascular resistances, and simultaneously increasing heart rate and ventricular wall volumes. Overall, reasonable agreement was found between model outputs and in vivo data, with the trends of the cardiac hemodynamic quantities suggesting correct response of the heart model throughout pregnancy. Results were reported for uterine hemodynamics, with flow tracings resembling typical Doppler velocity waveforms at each stage, including pulsatility indexes. Such a model may be used to explore the changes that happen during pregnancy in female with cardiovascular diseases.
- 22 January 2015
- Published by Springer Nature in Cardiovascular Engineering and Technology
- Vol. 6 (3) , 268-280
Pulmonary Hemodynamics Simulations Before Stage 2 Single Ventricle Surgery: Patient-Specific Parameter Identification and Clinical Data Assessment
Single ventricle heart defects involve pathologies in which the heart has only one functional pumping chamber. In these conditions, treatment consists of three staged procedures. At stage 1 pulmonary flow is provided through an artificial shunt from the systemic circulation. Representative hemodynamics models able to explore different virtual surgical options can be built based on pre-operative imaging and patient data. In this context, the specification of boundary conditions is necessary to compute pressure and flow in the entire domain. However, these boundary conditions are rarely the measured variables. Moreover, to take into account the rest of the circulation outside of the three-dimensional modeled domain, a number of reduced order models exist. A simplified method is presented to iteratively, but automatically, tune reduced model parameters from hemodynamic data clinically measured before stage 2 surgery. Patient-specific local hemodynamics around the distal systemic-to-pulmonary shunt anastomosis and the connected pulmonary arteries are also analyzed. Multi-scale models of pre-stage 2 single ventricle patients are developed, including a 3D model of shunt-pulmonary connection and a number of pulmonary arteries. For each pulmonary outlet a total downstream resistance is identified, consistent with measured flow split and pressures. Target pressures such as minimum, maximum or average over one or both lungs are considered, depending on the clinical measurement. When possible, both steady and pulsatile identifications are performed. The methodology is demonstrated with six patient-specific models: the clinical target data are well-matched, except for one case where clinical data were subsequently found inconsistent. Inhomogeneous pressure, swirling blood flow patterns and very high wall shear stress 3D maps highlight similarities and differences among patients. Steady and pulsatile tuning results are similar. This work demonstrates (1) how to use routine clinical data to define boundary conditions for patient-specific 3D models in pre-stage 2 single ventricle circulations and (2) how simulations can help to check the coherence of clinical data, or provide insights to clinicians that are otherwise difficult to measure, such as in the presence of kinks. Finally, the choice of steady vs. pulsatile tuning, limitations and possible extensions of this work are discussed.
- 22 January 2015
- Published by Springer Nature in Cardiovascular Engineering and Technology
- Vol. 6 (3) , 268-280
Pulmonary Hemodynamics Simulations Before Stage 2 Single Ventricle Surgery: Patient-Specific Parameter Identification and Clinical Data Assessment
Single ventricle heart defects involve pathologies in which the heart has only one functional pumping chamber. In these conditions, treatment consists of three staged procedures. At stage 1 pulmonary flow is provided through an artificial shunt from the systemic circulation. Representative hemodynamics models able to explore different virtual surgical options can be built based on pre-operative imaging and patient data. In this context, the specification of boundary conditions is necessary to compute pressure and flow in the entire domain. However, these boundary conditions are rarely the measured variables. Moreover, to take into account the rest of the circulation outside of the three-dimensional modeled domain, a number of reduced order models exist. A simplified method is presented to iteratively, but automatically, tune reduced model parameters from hemodynamic data clinically measured before stage 2 surgery. Patient-specific local hemodynamics around the distal systemic-to-pulmonary shunt anastomosis and the connected pulmonary arteries are also analyzed. Multi-scale models of pre-stage 2 single ventricle patients are developed, including a 3D model of shunt-pulmonary connection and a number of pulmonary arteries. For each pulmonary outlet a total downstream resistance is identified, consistent with measured flow split and pressures. Target pressures such as minimum, maximum or average over one or both lungs are considered, depending on the clinical measurement. When possible, both steady and pulsatile identifications are performed. The methodology is demonstrated with six patient-specific models: the clinical target data are well-matched, except for one case where clinical data were subsequently found inconsistent. Inhomogeneous pressure, swirling blood flow patterns and very high wall shear stress 3D maps highlight similarities and differences among patients. Steady and pulsatile tuning results are similar. This work demonstrates (1) how to use routine clinical data to define boundary conditions for patient-specific 3D models in pre-stage 2 single ventricle circulations and (2) how simulations can help to check the coherence of clinical data, or provide insights to clinicians that are otherwise difficult to measure, such as in the presence of kinks. Finally, the choice of steady vs. pulsatile tuning, limitations and possible extensions of this work are discussed.
- 25 October 2014
- Published by Springer Nature in Annals of Biomedical Engineering
- Vol. 43 (6) , 1310-1320
Integration of Clinical Data Collected at Different Times for Virtual Surgery in Single Ventricle Patients: A Case Study
Newborns with single ventricle physiology are usually palliated with a multi-staged procedure. When cardiovascular complications e.g., collateral vessel formation occur during the inter-stage periods, further treatments are required. An 8-month-old patient, who underwent second stage (i.e., bi-directional Glenn, BDG) surgery at 4 months, was diagnosed with a major veno-venous collateral vessel (VVC) which was endovascularly occluded to improve blood oxygen saturations. Few clinical data were collected at 8 months, whereas at 4 months a more detailed data set was available. The aim of this study is threefold: (i) to show how to build a patient-specific model describing the hemodynamics in the presence of VVC, using patient-specific clinical data collected at different times; (ii) to use this model to perform virtual VVC occlusion for quantitative hemodynamics prediction; and (iii) to compare predicted hemodynamics with post-operative measurements. The three-dimensional BDG geometry, resulting from the virtual surgery on the first stage model, was coupled with a lumped parameter model (LPM) of the 8-month patient’s circulation. The latter was developed by scaling the 4-month LPM to account for changes in vascular impedances due to growth and adaptation. After virtual VVC closure, the model confirmed the 2 mmHg BDG pressure increase, as clinically observed, suggesting the importance of modeling vascular adaptation following the BDG procedure.
- 25 October 2014
- Published by Springer Nature in Annals of Biomedical Engineering
- Vol. 43 (6) , 1310-1320
Integration of Clinical Data Collected at Different Times for Virtual Surgery in Single Ventricle Patients: A Case Study
Newborns with single ventricle physiology are usually palliated with a multi-staged procedure. When cardiovascular complications e.g., collateral vessel formation occur during the inter-stage periods, further treatments are required. An 8-month-old patient, who underwent second stage (i.e., bi-directional Glenn, BDG) surgery at 4 months, was diagnosed with a major veno-venous collateral vessel (VVC) which was endovascularly occluded to improve blood oxygen saturations. Few clinical data were collected at 8 months, whereas at 4 months a more detailed data set was available. The aim of this study is threefold: (i) to show how to build a patient-specific model describing the hemodynamics in the presence of VVC, using patient-specific clinical data collected at different times; (ii) to use this model to perform virtual VVC occlusion for quantitative hemodynamics prediction; and (iii) to compare predicted hemodynamics with post-operative measurements. The three-dimensional BDG geometry, resulting from the virtual surgery on the first stage model, was coupled with a lumped parameter model (LPM) of the 8-month patient’s circulation. The latter was developed by scaling the 4-month LPM to account for changes in vascular impedances due to growth and adaptation. After virtual VVC closure, the model confirmed the 2 mmHg BDG pressure increase, as clinically observed, suggesting the importance of modeling vascular adaptation following the BDG procedure.
- 1 August 2014
- Published by Elsevier in The Annals of Thoracic Surgery
- Vol. 98 (2) , 648-654
The Effect of Modified Blalock-Taussig Shunt Size and Coarctation Severity on Coronary Perfusion After the Norwood Operation
- 1 August 2014
- Published by Elsevier in The Annals of Thoracic Surgery
- Vol. 98 (2) , 648-654
The Effect of Modified Blalock-Taussig Shunt Size and Coarctation Severity on Coronary Perfusion After the Norwood Operation
- 30 May 2014
- Published by SAGE Publications in The International Journal of Artificial Organs
- Vol. 37 (5) , 371-381
Computational Models of Aortic Coarctation in Hypoplastic Left Heart Syndrome: Considerations on Validation of a Detailed 3D model
Background: Reliability of computational models for cardiovascular investigations strongly depends on their validation against physical data. This study aims to experimentally validate a computational model of complex congenital heart disease (i.e., surgically palliated hypoplastic left heart syndrome with aortic coarctation) thus demonstrating that hemodynamic information can be reliably extrapolated from the model for clinically meaningful investigations. Materials and methods: A patient-specific aortic arch model was tested in a mock circulatory system and the same flow conditions were re-created in silico, by setting an appropriate lumped parameter network (LPN) attached to the same three-dimensional (3D) aortic model (i.e., multi-scale approach). The model included a modified Blalock-Taussig shunt and coarctation of the aorta. Different flow regimes were tested as well as the impact of uncertainty in viscosity. Results: Computational flow and pressure results were in good agreement with the experimental signals, both qualitatively, in terms of the shape of the waveforms, and quantitatively (mean aortic pressure 62.3 vs. 65.1 mmHg, 4.8% difference; mean aortic flow 28.0 vs. 28.4% inlet flow, 1.4% difference; coarctation pressure drop 30.0 vs. 33.5 mmHg, 10.4% difference), proving the reliability of the numerical approach. It was observed that substantial changes in fluid viscosity or using a turbulent model in the numerical simulations did not significantly affect flows and pressures of the investigated physiology. Results highlighted how the non-linear fluid dynamic phenomena occurring in vitro must be properly described to ensure satisfactory agreement. Conclusions: This study presents methodological considerations for using experimental data to preliminarily set up a computational model, and then simulate a complex congenital physiology using a multi-scale approach.
- 30 May 2014
- Published by SAGE Publications in The International Journal of Artificial Organs
- Vol. 37 (5) , 371-381
Computational Models of Aortic Coarctation in Hypoplastic Left Heart Syndrome: Considerations on Validation of a Detailed 3D model
Background: Reliability of computational models for cardiovascular investigations strongly depends on their validation against physical data. This study aims to experimentally validate a computational model of complex congenital heart disease (i.e., surgically palliated hypoplastic left heart syndrome with aortic coarctation) thus demonstrating that hemodynamic information can be reliably extrapolated from the model for clinically meaningful investigations. Materials and methods: A patient-specific aortic arch model was tested in a mock circulatory system and the same flow conditions were re-created in silico, by setting an appropriate lumped parameter network (LPN) attached to the same three-dimensional (3D) aortic model (i.e., multi-scale approach). The model included a modified Blalock-Taussig shunt and coarctation of the aorta. Different flow regimes were tested as well as the impact of uncertainty in viscosity. Results: Computational flow and pressure results were in good agreement with the experimental signals, both qualitatively, in terms of the shape of the waveforms, and quantitatively (mean aortic pressure 62.3 vs. 65.1 mmHg, 4.8% difference; mean aortic flow 28.0 vs. 28.4% inlet flow, 1.4% difference; coarctation pressure drop 30.0 vs. 33.5 mmHg, 10.4% difference), proving the reliability of the numerical approach. It was observed that substantial changes in fluid viscosity or using a turbulent model in the numerical simulations did not significantly affect flows and pressures of the investigated physiology. Results highlighted how the non-linear fluid dynamic phenomena occurring in vitro must be properly described to ensure satisfactory agreement. Conclusions: This study presents methodological considerations for using experimental data to preliminarily set up a computational model, and then simulate a complex congenital physiology using a multi-scale approach.
- 1 January 2014
- Published by Elsevier in Journal of Surgical Research
- Vol. 186 (1) , 44-55
Numerical blood flow simulation in surgical corrections: what do we need for an accurate analysis?
- 1 January 2014
- Published by Elsevier in Journal of Surgical Research
- Vol. 186 (1) , 44-55
Numerical blood flow simulation in surgical corrections: what do we need for an accurate analysis?
- 1 December 2013
- Published by Elsevier in The Journal of Thoracic and Cardiovascular Surgery
- Vol. 146 (6) , 1341-1348
Effects of pulmonary artery banding and retrograde aortic arch obstruction on the hybrid palliation of hypoplastic left heart syndrome
- 1 December 2013
- Published by Elsevier in The Journal of Thoracic and Cardiovascular Surgery
- Vol. 146 (6) , 1341-1348
Effects of pulmonary artery banding and retrograde aortic arch obstruction on the hybrid palliation of hypoplastic left heart syndrome
- 23 January 2013
- Published by Taylor & Francis in Computer Methods in Biomechanics and Biomedical Engineering
- Vol. 17 (14) , 1572-1589
An integrated approach to patient-specific predictive modeling for single ventricle heart palliation
In patients with congenital heart disease and a single ventricle (SV), ventricular support of the circulation is inadequate, and staged palliative surgery (usually 3 stages) is needed for treatment. In the various palliative surgical stages individual differences in the circulation are important and patient-specific surgical planning is ideal. In this study, an integrated approach between clinicians and engineers has been developed, based on patient-specific multi-scale models, and is here applied to predict stage 2 surgical outcomes. This approach involves four distinct steps: (1) collection of pre-operative clinical data from a patient presenting for SV palliation, (2) construction of the pre-operative model, (3) creation of feasible virtual surgical options which couple a three-dimensional model of the surgical anatomy with a lumped parameter model (LPM) of the remainder of the circulation and (4) performance of post-operative simulations to aid clinical decision making. The pre-operative model is described, agreeing well with clinical flow tracings and mean pressures. Two surgical options (bi-directional Glenn and hemi-Fontan operations) are virtually performed and coupled to the pre-operative LPM, with the hemodynamics of both options reported. Results are validated against postoperative clinical data. Ultimately, this work represents the first patient-specific predictive modeling of stage 2 palliation using virtual surgery and closed-loop multi-scale modeling.
- 23 January 2013
- Published by Taylor & Francis in Computer Methods in Biomechanics and Biomedical Engineering
- Vol. 17 (14) , 1572-1589
An integrated approach to patient-specific predictive modeling for single ventricle heart palliation
In patients with congenital heart disease and a single ventricle (SV), ventricular support of the circulation is inadequate, and staged palliative surgery (usually 3 stages) is needed for treatment. In the various palliative surgical stages individual differences in the circulation are important and patient-specific surgical planning is ideal. In this study, an integrated approach between clinicians and engineers has been developed, based on patient-specific multi-scale models, and is here applied to predict stage 2 surgical outcomes. This approach involves four distinct steps: (1) collection of pre-operative clinical data from a patient presenting for SV palliation, (2) construction of the pre-operative model, (3) creation of feasible virtual surgical options which couple a three-dimensional model of the surgical anatomy with a lumped parameter model (LPM) of the remainder of the circulation and (4) performance of post-operative simulations to aid clinical decision making. The pre-operative model is described, agreeing well with clinical flow tracings and mean pressures. Two surgical options (bi-directional Glenn and hemi-Fontan operations) are virtually performed and coupled to the pre-operative LPM, with the hemodynamics of both options reported. Results are validated against postoperative clinical data. Ultimately, this work represents the first patient-specific predictive modeling of stage 2 palliation using virtual surgery and closed-loop multi-scale modeling.
- 1 January 2013
- Published by Elsevier in Journal of Biomechanics
- Vol. 46 (2) , 423-429
Predictive modeling of the virtual Hemi-Fontan operation for second stage single ventricle palliation: Two patient-specific cases
- 1 January 2013
- Published by Elsevier in Journal of Biomechanics
- Vol. 46 (2) , 423-429
Predictive modeling of the virtual Hemi-Fontan operation for second stage single ventricle palliation: Two patient-specific cases