Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Erik W. Sinsel has a total of 60 co-authors. Here are the top co-authors by number of shared publications:

  • John Z. Wu

    Health Effects Laboratory Division, National Institute for Occupational Safety & Health, Morgantown, WV 26505, USA

    10 shared publications
  • Christopher M. Warren

    National Institute for Occupational Safety and Health, Morgantown, WV, USA

    5 shared publications
  • Frank L. Buczek

    National Institute for Occupational Safety and Health (NIOSH), 1095 Willowdale Road MS 2027, Morgantown, WV 26505, USA; Present address: Lake Erie College of Osteopathic Medicine (LECOM), 1858 West Grandview Blvd, Erie, PA 16509, USA

    5 shared publications
  • Walter McKinney

    Health Effects Laboratory Division, National Institute for Occupational Safety and Health, Morgantown, WV, USA

    5 shared publications
  • Angela R. Lemons

    Allergy and Clinical Immunology Branch, Health Effects Laboratory Division, National Institute for Occupational Safety and Health, Centers for Disease Control and Prevention, Morgantown, WV 26505, USA

    4 shared publications
  • Christopher M. Warren

    National Institute for Occupational Safety and Health (NIOSH), Morgantown, WV 26505, USA

    4 shared publications

Latest Publications

  • Open Access

    Peracetic acid effects on human bronchial cells in an air liquid interface

    by Ellie S. Burns, Nicole S. Olgun, Sherri A. Friend, Walter G. McKinney, Erik W. Sinsel, Jeffrey S. Reynolds, Stephen S. Leonard

    Peracetic acid (PAA) is an organic peroxide commonly used as a disinfectant or sterilizing agent across many industries such as in agriculture, water treatment plants, and healthcare facilities. PAA is versatile, effective, and is considered environmentally friendly due to its decomposition products which include acetic acid, oxygen, and water. However, occupational researchers recognize that it is also highly corrosive as well as a strong oxidizer, and exposure to peracetic acid can severely irritate the respiratory system and this mixture can even act as an asthmagen. To determine the effect of PAA exposure to human airways, normal human bronchial epithelial cells (NHBE) were cultured at the air liquid interface and then exposed to PAA vapors generated across four separate concentrations: 0, 3, 12, and 24 ppm during four-hour exposure periods. Cells were allowed time to recover post-exposure for four and twenty-four hours prior to analysis. Cellular response and toxicity were assessed through metabolic assays for cell viability and cytotoxicity, cell layer integrity (using transepithelial electrical resistance (TEER) measures), and ELISA assays for endothelin-1 (ET-1) (pro-inflammatory mediator and vasoconstrictor) and pro-inflammatory cytokines (IL-6, IL-8). Histological changes were examined for presence of mucosubstances and overall tissue layer structure. PAA exposure had a significant effect on cytotoxicity wherein cytotoxic effect increased with dose concentration and recovery duration. Conversely, cell viability decreased significantly with dose and recovery period. Furthermore, exposure to PAA lowered transepithelial resistance significantly between controls and exposure conditions. ET-1, IL-6, and IL-8 were also assessed from culture fluid and were found to respond to dosage and recovery length. Histology suggested an injury response and cell layer disruptions at 12 ppm exposure and showed indicators of cell death at 24 ppm. Our findings suggest that PAA induces cell damage and a pro-inflammatory response in human bronchial cells with increasing dose and recovery time that reflects increased cell mortality at higher concentrations. Future work will extend this study to the human nasal epithelium to discern health effects across airway tissues.


  • Open Access

    Rat-Tail Models for Studying Hand-Arm Vibration Syndrome: A Comparison between Living and Cadaver Rat Tails

    by Christopher M. Warren, Xueyan S. Xu, Mark Jackson, Walter G. McKinney, John Z. Wu, Daniel E. Welcome, Stacey Waugh, Phillip Chapman, Erik W. Sinsel, Samantha Service, et al.

    Over-exposure of the hand-arm system to intense vibration and force over time may cause degeneration of the vascular, neurological, and musculoskeletal systems in the fingers. A novel animal model using rat tails has been developed to understand the health effects on human fingers exposed to vibration and force when operating powered hand tools or workpieces. The biodynamic responses, such as vibration stress, strain, and power absorption density, of the rat tails can be used to help evaluate the health effects related to vibration and force and to establish a dose-effect relationship. While the biodynamic responses of cadaver rat tails have been investigated, the objective of the current study was to determine whether the biodynamic responses of living rat tails are different from those of cadaver rat tails, and whether the biodynamic responses of both living and cadaver tails change with exposure duration. To make direct comparisons, the responses of both cadaver and living rat tails were examined on four different testing stations. The transfer function of each tail under a given contact force (2 N) was measured at each frequency in the one-third octave bands from 20 to 1000 Hz, and used to calculate the mechanical system parameters of the tails. The transfer functions were also measured at different exposure durations to determine the time dependency of the response. Differences were observed in the vibration biodynamic responses between living and cadaver tails, but the general trends were similar. The biodynamic responses of both cadaver and living rat tails varied with exposure duration.

  • Open Access

    Automated Classification of the Phases Relevant to Work-Related Musculoskeletal Injury Risks in Residential Roof Shingle Installation Operations Using Machine Learning

    by Amrita Dutta, Scott P. Breloff, Dilruba Mahmud, Fei Dai, Erik W. Sinsel, Christopher M. Warren, John Z. Wu

    Awkward kneeling in sloped shingle installation operations exposes roofers to knee musculoskeletal disorder (MSD) risks. To address the varying levels of risk associated with different phases of shingle installation, this research investigated utilizing machine learning to automatically classify seven distinct phases in a typical shingle installation task. The classification process relied on analyzing knee kinematics data and roof slope information. Nine participants were recruited and performed simulated shingle installation tasks while kneeling on a sloped wooden platform. The knee kinematics data were collected using an optical motion capture system. Three supervised machine learning classification methods (i.e., k-nearest neighbors (KNNs), decision tree (DT), and random forest (RF)) were selected for evaluation. The KNN classifier provided the best performance for overall accuracy. The results substantiated the feasibility of applying machine learning in classifying shingle installation phases from workers’ knee joint rotation and roof slope angles, which may help facilitate method and tool development for automated knee MSD risk surveillance and assessment among roofers.


  • Open Access

    Efficacy of Do-It-Yourself air filtration units in reducing exposure to simulated respiratory aerosols

    by Raymond C. Derk, Jayme P. Coyle, William G. Lindsley, Francoise M. Blachere, Angela R. Lemons, Samantha K. Service, Stephen B. Martin, Kenneth R. Mead, Steven A. Fotta, Jeffrey S. Reynolds, et al.


  • Open Access

    Reduction of exposure to simulated respiratory aerosols using ventilation, physical distancing, and universal masking

    by Jayme P. Coyle, Raymond C. Derk, William G. Lindsley, Theresa Boots, Francoise M. Blachere, Jeffrey S. Reynolds, Walter G. McKinney, Erik W. Sinsel, Angela R. Lemons, Donald H. Beezhold, et al.

    To limit community spread of SARS-CoV-2, CDC recommends universal masking indoors, maintaining 1.8 m of physical distancing, adequate ventilation, and avoiding crowded indoor spaces. Several studies have examined the independent influence of each control strategy in mitigating transmission in isolation, yet controls are often implemented concomitantly within an indoor environment. To address the influence of physical distancing, universal masking, and ventilation on very fine respiratory droplets and aerosol particle exposure, a simulator that coughed and exhaled aerosols (the source) and a second breathing simulator (the recipient) were placed in an exposure chamber. When controlling for the other two mitigation strategies, universal masking with 3-ply cotton masks reduced exposure to 0.3–3 µm coughed and exhaled aerosol particles by >77% compared to unmasked tests, whereas physical distancing (0.9 or 1.8 m) significantly changed exposure to cough but not exhaled aerosols. The effectiveness of ventilation depended upon the respiratory activity, that is, coughing or breathing, as well as the duration of exposure time. Our results demonstrate that a layered mitigation strategy approach of administrative and engineering controls can reduce personal inhalation exposure to potentially infectious very fine respiratory droplets and aerosol particles within an indoor environment.


  • Open Access

    Efficacy of Ventilation, HEPA Air Cleaners, Universal Masking, and Physical Distancing for Reducing Exposure to Simulated Exhaled Aerosols in a Meeting Room

    by Jayme P. Coyle, Raymond C. Derk, William G. Lindsley, Francoise M. Blachere, Theresa Boots, Angela R. Lemons, Stephen B. Martin, Kenneth R. Mead, Steven A. Fotta, Jeffrey S. Reynolds, et al.

    There is strong evidence associating the indoor environment with transmission of SARS-CoV-2, the virus that causes COVID-19. SARS-CoV-2 can spread by exposure to droplets and very fine aerosol particles from respiratory fluids that are released by infected persons. Layered mitigation strategies, including but not limited to maintaining physical distancing, adequate ventilation, universal masking, avoiding overcrowding, and vaccination, have shown to be effective in reducing the spread of SARS-CoV-2 within the indoor environment. Here, we examine the effect of mitigation strategies on reducing the risk of exposure to simulated respiratory aerosol particles within a classroom-style meeting room. To quantify exposure of uninfected individuals (Recipients), surrogate respiratory aerosol particles were generated by a breathing simulator with a headform (Source) that mimicked breath exhalations. Recipients, represented by three breathing simulators with manikin headforms, were placed in a meeting room and affixed with optical particle counters to measure 0.3–3 µm aerosol particles. Universal masking of all breathing simulators with a 3-ply cotton mask reduced aerosol exposure by 50% or more compared to scenarios with simulators unmasked. While evaluating the effect of Source placement, Recipients had the highest exposure at 0.9 m in a face-to-face orientation. Ventilation reduced exposure by approximately 5% per unit increase in air change per hour (ACH), irrespective of whether increases in ACH were by the HVAC system or portable HEPA air cleaners. The results demonstrate that mitigation strategies, such as universal masking and increasing ventilation, reduce personal exposure to respiratory aerosols within a meeting room. While universal masking remains a key component of a layered mitigation strategy of exposure reduction, increasing ventilation via system HVAC or portable HEPA air cleaners further reduces exposure.


  • Open Access

    Reduction of exposure to simulated respiratory aerosols using ventilation, physical distancing, and universal masking

    by Jayme P. Coyle, Raymond C. Derk, William G. Lindsley, Theresa Boots, Francoise M. Blachere, Jeffrey S. Reynolds, Walter G. McKinney, Erik W. Sinsel, Angela R. Lemons, Donald H. Beezhold, et al.

    To limit community spread of SARS-CoV-2, CDC recommends universal masking indoors, maintaining 1.8 m of physical distancing, adequate ventilation, and avoiding crowded indoor spaces. Several studies have examined the independent influence of each control strategy in mitigating transmission in isolation, yet controls are often implemented concomitantly within an indoor environment. To address the influence of physical distancing, universal masking, and ventilation on very fine respiratory droplets and aerosol particle exposure, a simulator that coughed and exhaled aerosols (the source) and a second breathing simulator (the recipient) were placed in an exposure chamber. When controlling for the other two mitigation strategies, universal masking with 3-ply cotton masks reduced exposure to 0.3–3 µm coughed and exhaled aerosol particles by > 77% compared to unmasked tests, whereas physical distancing (0.9 or 1.8 m) significantly changed exposure to cough but not exhaled aerosols. The effectiveness of ventilation depended upon the respiratory activity, i.e., coughing or breathing, as well as the duration of exposure time. Our results demonstrate that a combination of administrative and engineering controls can reduce personal inhalation exposure to potentially infectious very fine respiratory droplets and aerosol particles within an indoor environment. PRACTICAL IMPLICATIONS Universal masking provided the most effective strategy in reducing inhalational exposure to simulated aerosols. Physical distancing provided limited reductions in exposure to small aerosol particles. Ventilation promotes air mixing in addition to aerosol removal, thus altering the exposure profile to individuals. A combination of mitigation strategies can effectively reduce exposure to potentially infectious aerosols.

  • Fusing imperfect experimental data for risk assessment of musculoskeletal disorders in construction using canonical polyadic decomposition

    by Amrita Dutta, Scott P. Breloff, Fei Dai, Erik W. Sinsel, Robert E. Carey, Christopher M. Warren, John Z. Wu


  • Biomechanical modeling of deep squatting: Effects of the interface contact between posterior thigh and shank

    by John Z. Wu, Erik W. Sinsel, Robert E. Carey, Liying Zheng, Christopher M. Warren, Scott P. Breloff


  • Assessing work-related risk factors for musculoskeletal knee disorders in construction roofing tasks

    by Scott P. Breloff, Amrita Dutta, Fei Dai, Erik W. Sinsel, Christopher M. Warren, Xiaopeng Ning, John Z. Wu