RMRadhe Mohan

Radhe Mohan

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Radhe Mohan has a total of 364 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Bayesian personalized dose constraints in selecting patients with non-small cell lung cancer for cardiac risk-adaptive treatment

    by Mei Chen, Tianlin Xu, Ting Xu, Rachel C. Maguire, Xinru Chen, Efstratios Koutroumpakis, Anita Deswal, Ali Ajdari, Joshua S. Niedzielski, Jinzhong Yang, et al.

  • Open Access

    DNA damage complexity as a predictor of cell survival: a microscopic Monte Carlo-based modeling framework for photon, proton and carbon ion irradiation

    by Miao Qi, Youfang Lai, Fada Guan, Meiying Xing, Lawrence Bronk, Radhe Mohan, Heng Li, Yujie Chi, Xun Jia

    Objective: Biological effect of charged particles characterized by cell surviving fraction (SF) depends on physical factors such as particle type, dose, beam quality descriptors, e.g. linear energy transfer (LET) or lineal energy. Driven by the crucial role of DNA double-strand breaks (DSBs) as indicators of cellular responses to ionizing radiation, this study aims to develop a cell-specific SF model based on the initial DSBs of varying complexities universal with respect to photon, proton, and carbon-ion irradiations across different beam qualities. Approach: Microscopic Monte Carlo simulations (MMCSs) were used to calculate DSBs for experiments measuring SF of H460 and H1437 lung cancer cells irradiated by proton (dose-mean lineal energy y ̅_d 2.0-20.0 keV/ µm), carbon ions (y ̅_d 18.6-87.9 keV/µm) and reference 137Cs photon beam. We modeled SF as a third-order polynomial function of DSBs of various complexities with two, three, and more strand breaks. The function was determined by a data fitting process. Main results: For each cell line, a single model was able to accurately describe SF in experiments under all 19 irradiation conditions with different particle types and y ̅_d values. Root Mean Square Errors were 0.218 for H460 cells and 0.170 for H1437 cells. When applying the model to a proton spread-out-Bragg-peak case, calculated relative biological effectiveness at SF=0.1 were 1.01-1.42 for the H460 cells and 1.03-1.65 for the H1437 cells depending on the depth. Significance: We successfully developed a SF model using DSBs of various complexities as input variables. The model is universally applicable to photon, proton, and carbon-ion irradiations across different beam qualities.

  • Musculoskeletal and Marrow Sparing With Proton FLASH Radiation Therapy in Juvenile Mice

    by Zongsheng Hu, Uwe Titt, Yuting Li, Elise Konradsson, Edgardo A. Aguilar, Denae W. Neill, Luke Connell, Xiaochun Wang, Henry James Meyer, Mihai Lurascu Gagea, et al.

  • Open Access

    Long-term Musculoskeletal and Marrow Sparing with Proton FLASH in Juvenile Mice: Implications for Pediatric Osteosarcoma

    by Zongsheng Hu, Uwe Titt, Yuting Li, Elise Konradsson, Edgardo A Aguilar, Denae W Neill, Luke Connell, Xiaochun Wang, Henry James Meyer, Mihai Lurascu Gagea, et al.

    Purpose: Osteosarcoma is the most common primary bone malignancy in children and adolescents. Radiotherapy is limited by intrinsic radioresistance and the risk of severe long-term musculoskeletal toxicities. FLASH radiotherapy, delivered at ultra-high dose rates (>40 Gy/s), has demonstrated normal tissue sparing in preclinical models, but its effects on the developing skeleton and marrow remain poorly defined. This study evaluated the chronic normal tissue effects of proton FLASH in juvenile mice, modeling the pediatric context. Methods and Materials: Juvenile C57BL/6 mice (3–4 weeks old) were randomized to receive 11 Gy FLASH (≈200 Gy/s) or conventional proton irradiation (0.2 Gy/s average), or sham treatment to the left hind leg using a synchrotron-based proton beamline. Mice were followed for 10 weeks post-treatment. Bone toxicity was assessed with microCT (bone mineral density, bone volume fractions, trabecular indices) and histology. Bone marrow cellularity was quantified on H&E-stained sections, and muscle fibrosis was assessed using Masson’s trichrome. Results: FLASH-treated mice exhibited significant preservation of bone microarchitecture compared with conventional treated mice, with higher bone mineral density and bone volume fractions (p < 0.05). Trabecular numbers were maintained, while structure model index indicates a mechanically favorable trabecular structures in the FLASH group. Bone marrow cellularity was preserved in FLASH mice (5.3% reduction vs. sham) compared with conventional (11.3 % reduction, p < 0.05). Muscle fibrosis was significantly lower in FLASH group (fibrosis positivity 2.6 % vs. 3.0% for FLASH vs. conventional CONV, p < 0.05). No severe immobility or weight loss was observed across groups. Conclusions: Proton FLASH significantly reduces long-term bone, marrow, and muscle toxicities in juvenile mice. These findings provide the first demonstration of musculoskeletal sparing in a synchrotron proton FLASH platform and highlight its translational potential for pediatric osteosarcoma.


  • Open Access

    A novel microdosimetry-based formalism for cell survival modelling applicable to hypofractionated radiotherapy

    by Oleg N Vassiliev, Radhe Mohan

    Objectives. Hypofractionated radiotherapy requires reliable cell survival models for doses much higher than the standard 2 Gy, for which the linear-quadratic (LQ) model is not applicable. We developed an alternative approach applicable to both low doses and high doses used in hypofractionated treatments and radiobiological experiments. Approach. We combined a standard microdosimetric technique with a recently introduced non-LQ cell survival model. Our formulation accounts for cell damage by multi-track events involving any number of particles. This is necessary for modelling cell survival at therapeutic doses. We characterise each cell type by the size R of the sensitive volume (SV) and biological response function B(q), where q is the total energy deposited in the SV after a given dose is delivered. q is a random quantity characterised by a probability density (microdosimetric spectrum) calculate with Geant4. We determine R and B(q) through an optimisation procedure that minimises differences between model predictions and cell survival measurements that cover an appropriate linear energy transfer (LET) range. Main results. Our method eliminated a serious flaw of the standard microdosimetric approach—arbitrary SV size. We determine SV size by solving the above optimisation problem. Furthermore, our method drastically simplifies calculations of multi-particle microdosimetric spectra. We applied our approach to 24 proton survival curves for three cell lines with various irradiation conditions and LET range of 0.589–19.6 keV µm−1 with good agreement between all these measurements and the model. R for a given cell type depended on fluence spectrum and increased with increasing LET owing to variations in the development and spatial spread of damage triggered by initial physical impact. This differ from the standard microdosimetry where SV size is constant. Significance. Our model is relatively simple and suitable for implementation in a treatment planning system potentially improving treatment plan optimisation, calculation of RBEs and biologically equivalent doses.

  • Open Access

    Mimicking large spot‐scanning radiation fields for proton FLASH preclinical studies with a robotic motion platform

    by Fada Guan, Dadi Jiang, Xiaochun Wang, Ming Yang, Kiminori Iga, Yuting Li, Lawrence Bronk, Julianna Bronk, Liang Wang, Youming Guo, et al.

    Previously, a synchrotron‐based horizontal proton beamline (87.2 MeV) was successfully commissioned to deliver radiation doses in FLASH and conventional dose rate modes to small fields and volumes. In this study, we developed a strategy to increase the effective radiation field size using a custom robotic motion platform to automatically shift the positions of biological samples. The beam was first broadened with a thin tungsten scatterer and shaped by customized brass collimators for irradiating cell/organoid cultures in 96‐well plates (a 7‐mm‐diameter circle) or for irradiating mice (1‐cm2 square). Motion patterns of the robotic platform were written in G‐code, with 9‐mm spot spacing used for the 96‐well plates and 10.6‐mm spacing for the mice. The accuracy of target positioning was verified with a self‐leveling laser system. The dose delivered in the experimental conditions was validated with EBT‐XD film attached to the 96‐well plate or the back of the mouse. Our film‐measured dose profiles matched Monte Carlo calculations well (1D gamma pass rate >95% with the criteria of 2%/1 mm/2% dose threshold). The FLASH dose rates were 113.7 Gy/s for cell/organoid irradiation and 191.3 Gy/s for mouse irradiation. These promising results indicate that this robotic platform can be used to effectively increase the field size for preclinical experiments with proton FLASH.


  • Open Access

    Interpreting the biological effects of protons as a function of physical quantity: linear energy transfer or microdosimetric lineal energy spectrum?

    by Fada Guan, Lawrence Bronk, Matthew Kerr, Yuting Li, Leslie A. Braby, Mary Sobieski, Xiaochun Wang, Xiaodong Zhang, Clifford Stephan, David R. Grosshans, et al.

    The choice of appropriate physical quantities to characterize the biological effects of ionizing radiation has evolved over time coupled with advances in scientific understanding. The basic hypothesis in radiation dosimetry is that the energy deposited by ionizing radiation initiates all the consequences of exposure in a biological sample (e.g., DNA damage, reproductive cell death). Physical quantities defined to characterize energy deposition have included dose, a measure of the mean energy imparted per unit mass of the target, and linear energy transfer (LET), a measure of the mean energy deposition per unit distance that charged particles traverse in a medium. The primary advantage of using the “dose and LET” physical system is its relative simplicity, especially for presenting and recording results. Inclusion of additional information such as the energy spectrum of charged particles renders this approach adequate to describe the biological effects of large dose levels from homogeneous sources. The primary disadvantage of this system is that it does not provide a unique description of the stochastic nature of radiation interactions. We and others have used dose-averaged LET (LETd) as a correlative physical quantity to the relative biological effectiveness (RBE) of proton beams. This approach is based on established experimental findings that proton RBE increases with LETd. However, this approach might not be applicable to intensity-modulated proton therapy or other applications in which the proton energy spectrum is highly heterogeneous. In the current study, we irradiated cancer cells with scanning proton beams with identical LETd (3.4 keV/µm) but arising from two different proton energy/LET spectra (a narrow spectrum in group 1 and a widespread heterogeneous spectrum in group 2). Clonogenic survival after irradiation revealed significant differences in RBE at any cell surviving fraction: e.g., at a surviving fraction of 0.1, the RBE was 0.97 ± 0.03 in group 1 and 1.16 ± 0.04 in group 2 (p≤0.01), validating our hypothesis that LETd alone may not adequately indicate proton RBE. Further analysis showed that microdosimetric spectrum (the probability density function of the stochastic physical quantity lineal energy y) was helpful for interpreting observed differences in biological effects. However, more accurate use of microdosimetric spectrum to quantify RBE requires a cell line–specific mechanistic model.


    • 14 September 2024
    Open Access

    Mimicking large spot-scanning radiation fields for proton FLASH preclinical studies with a robotic motion platform

    by Fada Guan, Dadi Jiang, Xiaochun Wang, Ming Yang, Kiminori Iga, Yuting Li, Lawrence Bronk, Julianna Bronk, Liang Wang, Youming Guo, et al.

    Previously, a synchrotron-based horizontal proton beamline (87.2 MeV) was successfully commissioned to deliver radiation doses in FLASH and conventional dose rate modes to small fields and volumes. In this study, we developed a strategy to increase the effective radiation field size using a custom robotic motion platform to automatically shift the positions of biological samples. The beam was first broadened with a thin tungsten scatterer and shaped by customized brass collimators for irradiating cell/organoid cultures in 96-well plates (a 7-mm-diameter circle) or for irradiating mice (1-cm2 square). Motion patterns of the robotic platform were written in G-code, with 9-mm spot spacing used for the 96-well plates and 10.6-mm spacing for the mice. The accuracy of target positioning was verified with a self-leveling laser system. The dose delivered in the experimental conditions was validated with EBT-XD film attached to the 96-well plate or the back of the mouse. Our film-measured dose profiles matched Monte Carlo calculations well (1D gamma pass rate >95%). The FLASH dose rates were 113.7 Gy/s for cell/organoid irradiation and 191.3 Gy/s for mouse irradiation. These promising results indicate that this robotic platform can be used to effectively increase the field size for preclinical experiments with proton FLASH.

  • Open Access

    Mimicking large spot-scanning radiation fields for proton FLASH preclinical studies with a robotic motion platform

    by Fada Guan, Dadi Jiang, Xiaochun Wang, Ming Yang, Kiminori Iga, Yuting Li, Lawrence Bronk, Julianna Bronk, Liang Wang, Youming Guo, et al.

    Previously, a synchrotron-based horizontal proton beamline (87.2 MeV) was successfully commissioned to deliver radiation doses in FLASH and conventional dose rate modes to small fields and volumes. In this study, we developed a strategy to increase the effective radiation field size using a custom robotic motion platform to automatically shift the positions of biological samples. The beam was first broadened with a thin tungsten scatterer and shaped by customized brass collimators for irradiating cell/organoid cultures in 96-well plates (a 7-mm-diameter circle) or for irradiating mice (1-cm2 square). Motion patterns of the robotic platform were written in G-code, with 9-mm spot spacing used for the 96-well plates and 10.6-mm spacing for the mice. The accuracy of target positioning was verified with a self-leveling laser system. The dose delivered in the experimental conditions was validated with EBT-XD film attached to the 96-well plate or the back of the mouse. Our film-measured dose profiles matched Monte Carlo calculations well (1D gamma pass rate >95%). The FLASH dose rates were 113.7 Gy/s for cell/organoid irradiation and 191.3 Gy/s for mouse irradiation. These promising results indicate that this robotic platform can be used to effectively increase the field size for preclinical experiments with proton FLASH.

  • Open Access

    Radiation-Induced Lymphopenia is a Causal Mediator of Survival After Chemoradiation Therapy for Esophagus Cancer

    by Yiqing Chen, Yan Chu, Peter S.N. van Rossum, Clemens Grassberger, Steven H. Lin, Radhe Mohan, Brian P. Hobbs