Juan Pedro Vigueras Guillen
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Juan Pedro Vigueras Guillen has a total of 26 co-authors. Here are the top co-authors by number of shared publications:
Koenraad A. Vermeer
Rotterdam Ophthalmic Institute, Rotterdam Eye Hospital, Rotterdam, The Netherlands
7 shared publicationsHans G. Lemij
Rotterdam Eye Hospital, Rotterdam, The Netherlands
3 shared publications- Hans G. Lemij
Rotterdam Ophthalmic Institute, Rotterdam Eye Hospital, Rotterdam, The Netherlands
3 shared publications Jeroen van Rooij
Rotterdam Eye Hospital, Rotterdam, The Netherlands
3 shared publications- Jeroen van Rooij
Department of Neurology, Erasmus Medical Center, Rotterdam, The Netherlands
3 shared publications Lucas J. van Vliet
Department of Imaging Physics, Delft University of Technology, Delft, the Netherlands
3 shared publications
Latest Publications
- 21 September 2021
- Published by Springer Nature
- p. 743-752
Parallel Capsule Networks for Classification of White Blood Cells
- 21 September 2021
- Published by Springer Nature
- p. 743-752
Parallel Capsule Networks for Classification of White Blood Cells
- Open Access
Parallel Capsule Networks for Classification of White Blood Cells
Capsule Networks (CapsNets) is a machine learning architecture proposed to overcome some of the shortcomings of convolutional neural networks (CNNs). However, CapsNets have mainly outperformed CNNs in datasets where images are small and/or the objects to identify have minimal background noise. In this work, we present a new architecture, parallel CapsNets, which exploits the concept of branching the network to isolate certain capsules, allowing each branch to identify different entities. We applied our concept to the two current types of CapsNet architectures, studying the performance for networks with different layers of capsules. We tested our design in a public, highly unbalanced dataset of acute myeloid leukaemia images (15 classes). Our experiments showed that conventional CapsNets show similar performance than our baseline CNN (ResNeXt-50) but depict instability problems. In contrast, parallel CapsNets can outperform ResNeXt-50, is more stable, and shows better rotational invariance than both, conventional CapsNets and ResNeXt-50.
Open AccessParallel Capsule Networks for Classification of White Blood Cells
Capsule Networks (CapsNets) is a machine learning architecture proposed to overcome some of the shortcomings of convolutional neural networks (CNNs). However, CapsNets have mainly outperformed CNNs in datasets where images are small and/or the objects to identify have minimal background noise. In this work, we present a new architecture, parallel CapsNets, which exploits the concept of branching the network to isolate certain capsules, allowing each branch to identify different entities. We applied our concept to the two current types of CapsNet architectures, studying the performance for networks with different layers of capsules. We tested our design in a public, highly unbalanced dataset of acute myeloid leukaemia images (15 classes). Our experiments showed that conventional CapsNets show similar performance than our baseline CNN (ResNeXt-50) but depict instability problems. In contrast, parallel CapsNets can outperform ResNeXt-50, is more stable, and shows better rotational invariance than both, conventional CapsNets and ResNeXt-50.
- Open Access
- 28 January 2020
- Published by Association for Research in Vision and Ophthalmology (ARVO) in Translational Vision Science & Technology
- Vol. 9 (2) , 49
Deep Learning for Assessing the Corneal Endothelium from Specular Microscopy Images up to 1 Year after Ultrathin-DSAEK Surgery
Purpose: To present a fully automatic method to estimate the corneal endothelium parameters from specular microscopy images and to use it to study a one-year follow-up after ultrathin Descemet stripping automated endothelial keratoplasty. Methods: We analyzed 383 post ultrathin Descemet stripping automated endothelial keratoplasty images from 41 eyes acquired with a Topcon SP-1P specular microscope at 1, 3, 6, and 12 months after surgery. The estimated parameters were endothelial cell density (ECD), coefficient of variation (CV), and hexagonality (HEX). Manual segmentation was performed in all images. Results: Our method provided an estimate for ECD, CV, and HEX in 98.4% of the images, whereas Topcon's software had a success rate of 71.5% for ECD/CV and 30.5% for HEX. For the images with estimates, the percentage error in our method was 2.5% for ECD, 5.7% for CV, and 5.7% for HEX, whereas Topcon's software provided an error of 7.5% for ECD, 17.5% for CV, and 18.3% for HEX. Our method was significantly better than Topcon's (P < 0.0001) and was not statistically significantly different from the manual assessments (P > 0.05). At month 12, the subjects presented an average ECD = 1377 ± 483 [cells/mm2], CV = 26.1 ± 5.7 [%], and HEX = 58.1 ± 7.1 [%]. Conclusions: The proposed method obtains reliable and accurate estimations even in challenging specular images of pathologic corneas. Translational Relevance: CV and HEX, not currently used in the clinic owing to a lack of reliability in automatic methods, are useful biomarkers to analyze the postoperative healing process. Our accurate estimations allow now for their clinical use.
- 28 January 2020
- Published by Association for Research in Vision and Ophthalmology (ARVO) in Translational Vision Science & Technology
- Vol. 9 (2) , 49
Open AccessDeep Learning for Assessing the Corneal Endothelium from Specular Microscopy Images up to 1 Year after Ultrathin-DSAEK Surgery
Purpose: To present a fully automatic method to estimate the corneal endothelium parameters from specular microscopy images and to use it to study a one-year follow-up after ultrathin Descemet stripping automated endothelial keratoplasty. Methods: We analyzed 383 post ultrathin Descemet stripping automated endothelial keratoplasty images from 41 eyes acquired with a Topcon SP-1P specular microscope at 1, 3, 6, and 12 months after surgery. The estimated parameters were endothelial cell density (ECD), coefficient of variation (CV), and hexagonality (HEX). Manual segmentation was performed in all images. Results: Our method provided an estimate for ECD, CV, and HEX in 98.4% of the images, whereas Topcon's software had a success rate of 71.5% for ECD/CV and 30.5% for HEX. For the images with estimates, the percentage error in our method was 2.5% for ECD, 5.7% for CV, and 5.7% for HEX, whereas Topcon's software provided an error of 7.5% for ECD, 17.5% for CV, and 18.3% for HEX. Our method was significantly better than Topcon's (P < 0.0001) and was not statistically significantly different from the manual assessments (P > 0.05). At month 12, the subjects presented an average ECD = 1377 ± 483 [cells/mm2], CV = 26.1 ± 5.7 [%], and HEX = 58.1 ± 7.1 [%]. Conclusions: The proposed method obtains reliable and accurate estimations even in challenging specular images of pathologic corneas. Translational Relevance: CV and HEX, not currently used in the clinic owing to a lack of reliability in automatic methods, are useful biomarkers to analyze the postoperative healing process. Our accurate estimations allow now for their clinical use.
- 1 November 2019
- Published by Elsevier in Ophthalmology Retina
- Vol. 3 (11) , 938-946
The Influence of Prolongation of Interruptions of Preoperative Posturing and Other Clinical Factors on the Progress of Macula-On Retinal Detachment
- 1 November 2019
- Published by Elsevier in Ophthalmology Retina
- Vol. 3 (11) , 938-946
The Influence of Prolongation of Interruptions of Preoperative Posturing and Other Clinical Factors on the Progress of Macula-On Retinal Detachment
- 1 July 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 2019, 876-881
Convolutional neural network-based regression for biomarker estimation in corneal endothelium microscopy images
The morphometric parameters of the corneal endothelium – cell density (ECD), cell size variation (CV), and hexagonality (HEX) – provide clinically relevant information about the cornea. To estimate these parameters, the endothelium is commonly imaged with a non-contact specular microscope and cell segmentation is performed to these images. In previous work, we have developed several methods that, combined, can perform an automated estimation of the parameters: the inference of the cell edges, the detection of the region of interest (ROI), a post-processing method that combines both images (edges and ROI), and a refinement method that removes false edges. In this work, we first explore the possibility of using a CNN-based regressor to directly infer the parameters from the edge images, simplifying the framework. We use a dataset of 738 images coming from a study related to the implantation of a Baerveldt glaucoma device and a standard clinical care regarding DSAEK corneal transplantation, both from the Rotterdam Eye Hospital and both containing images of unhealthy endotheliums. This large dataset allows us to build a large training set that makes this approach feasible. We achieved a mean absolute percentage error (MAPE) of 4.32% for ECD, 7.07% for CV, and 11.74% for HEX. These results, while promising, do not outperform our previous work. In a second experiment, we explore the use of the CNN-based regressor to improve the post-processing method of our previous approach in order to adapt it to the specifics of each image. Our results showed no clear benefit and proved that our previous post-processing is already highly reliable and robust.
- 1 July 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 2019, 876-881
Convolutional neural network-based regression for biomarker estimation in corneal endothelium microscopy images
The morphometric parameters of the corneal endothelium – cell density (ECD), cell size variation (CV), and hexagonality (HEX) – provide clinically relevant information about the cornea. To estimate these parameters, the endothelium is commonly imaged with a non-contact specular microscope and cell segmentation is performed to these images. In previous work, we have developed several methods that, combined, can perform an automated estimation of the parameters: the inference of the cell edges, the detection of the region of interest (ROI), a post-processing method that combines both images (edges and ROI), and a refinement method that removes false edges. In this work, we first explore the possibility of using a CNN-based regressor to directly infer the parameters from the edge images, simplifying the framework. We use a dataset of 738 images coming from a study related to the implantation of a Baerveldt glaucoma device and a standard clinical care regarding DSAEK corneal transplantation, both from the Rotterdam Eye Hospital and both containing images of unhealthy endotheliums. This large dataset allows us to build a large training set that makes this approach feasible. We achieved a mean absolute percentage error (MAPE) of 4.32% for ECD, 7.07% for CV, and 11.74% for HEX. These results, while promising, do not outperform our previous work. In a second experiment, we explore the use of the CNN-based regressor to improve the post-processing method of our previous approach in order to adapt it to the specifics of each image. Our results showed no clear benefit and proved that our previous post-processing is already highly reliable and robust.
- 15 March 2019
- Published by SPIE-Intl Soc Optical Eng
- Vol. 10949, 108
Automatic detection of the region of interest in corneal endothelium images using dense convolutional neural networks
In images of the corneal endothelium (CE) acquired by specular microscopy, endothelial cells are commonly only visible in a part of the image due to varying contrast, mainly caused by challenging imaging conditions as a result of a strongly curved endothelium. In order to estimate the morphometric parameters of the corneal endothelium, the analyses need to be restricted to trustworthy regions – the region of interest (ROI) – where individual cells are discernible. We developed an automatic method to find the ROI by Dense U-nets, a densely connected network of convolutional layers. We tested the method on a heterogeneous dataset of 140 images, which contains a large number of blurred, noisy, and/or out of focus images, where the selection of the ROI for automatic biomarker extraction is vital. By using edge images as input, which can be estimated after retraining the same network, Dense U-net detected the trustworthy areas with an accuracy of 98.94% and an area under the ROC curve (AUC) of 0.998, without being affected by the class imbalance (9:1 in our dataset). After applying the estimated ROI to the edge images, the mean absolute percentage error (MAPE) in the estimated endothelial parameters was 0.80% for ECD, 3.60% for CV, and 2.55% for HEX.
- 15 March 2019
- Published by SPIE-Intl Soc Optical Eng
- Vol. 10949, 108
Automatic detection of the region of interest in corneal endothelium images using dense convolutional neural networks
In images of the corneal endothelium (CE) acquired by specular microscopy, endothelial cells are commonly only visible in a part of the image due to varying contrast, mainly caused by challenging imaging conditions as a result of a strongly curved endothelium. In order to estimate the morphometric parameters of the corneal endothelium, the analyses need to be restricted to trustworthy regions – the region of interest (ROI) – where individual cells are discernible. We developed an automatic method to find the ROI by Dense U-nets, a densely connected network of convolutional layers. We tested the method on a heterogeneous dataset of 140 images, which contains a large number of blurred, noisy, and/or out of focus images, where the selection of the ROI for automatic biomarker extraction is vital. By using edge images as input, which can be estimated after retraining the same network, Dense U-net detected the trustworthy areas with an accuracy of 98.94% and an area under the ROC curve (AUC) of 0.998, without being affected by the class imbalance (9:1 in our dataset). After applying the estimated ROI to the edge images, the mean absolute percentage error (MAPE) in the estimated endothelial parameters was 0.80% for ECD, 3.60% for CV, and 2.55% for HEX.
- Open Access
- 30 January 2019
- Published by Springer Nature in BMC Biomedical Engineering
- Vol. 1 (1) , 1-16
Fully convolutional architecture vs sliding-window CNN for corneal endothelium cell segmentation
Corneal endothelium (CE) images provide valuable clinical information regarding the health state of the cornea. Computation of the clinical morphometric parameters requires the segmentation of endothelial cell images. Current techniques to image the endothelium in vivo deliver low quality images, which makes automatic segmentation a complicated task. Here, we present two convolutional neural networks (CNN) to segment CE images: a global fully convolutional approach based on U-net, and a local sliding-window network (SW-net). We propose to use probabilistic labels instead of binary, we evaluate a preprocessing method to enhance the contrast of images, and we introduce a postprocessing method based on Fourier analysis and watershed to convert the CNN output images into the final cell segmentation. Both methods are applied to 50 images acquired with an SP-1P Topcon specular microscope. Estimates are compared against a manual delineation made by a trained observer. U-net (AUC=0.9938) yields slightly sharper, clearer images than SW-net (AUC=0.9921). After postprocessing, U-net obtains a DICE=0.981 and a MHD=0.22 (modified Hausdorff distance), whereas SW-net yields a DICE=0.978 and a MHD=0.30. U-net generates a wrong cell segmentation in only 0.48% of the cells, versus 0.92% for the SW-net. U-net achieves statistically significant better precision and accuracy than both, Topcon and SW-net, for the estimates of three clinical parameters: cell density (ECD), polymegethism (CV), and pleomorphism (HEX). The mean relative error in U-net for the parameters is 0.4% in ECD, 2.8% in CV, and 1.3% in HEX. The computation time to segment an image and estimate the parameters is barely a few seconds. Both methods presented here provide a statistically significant improvement over the state of the art. U-net has reached the smallest error rate. We suggest a segmentation refinement based on our previous work to further improve the performance.
- 30 January 2019
- Published by Springer Nature in BMC Biomedical Engineering
- Vol. 1 (1) , 1-16
Open AccessFully convolutional architecture vs sliding-window CNN for corneal endothelium cell segmentation
Corneal endothelium (CE) images provide valuable clinical information regarding the health state of the cornea. Computation of the clinical morphometric parameters requires the segmentation of endothelial cell images. Current techniques to image the endothelium in vivo deliver low quality images, which makes automatic segmentation a complicated task. Here, we present two convolutional neural networks (CNN) to segment CE images: a global fully convolutional approach based on U-net, and a local sliding-window network (SW-net). We propose to use probabilistic labels instead of binary, we evaluate a preprocessing method to enhance the contrast of images, and we introduce a postprocessing method based on Fourier analysis and watershed to convert the CNN output images into the final cell segmentation. Both methods are applied to 50 images acquired with an SP-1P Topcon specular microscope. Estimates are compared against a manual delineation made by a trained observer. U-net (AUC=0.9938) yields slightly sharper, clearer images than SW-net (AUC=0.9921). After postprocessing, U-net obtains a DICE=0.981 and a MHD=0.22 (modified Hausdorff distance), whereas SW-net yields a DICE=0.978 and a MHD=0.30. U-net generates a wrong cell segmentation in only 0.48% of the cells, versus 0.92% for the SW-net. U-net achieves statistically significant better precision and accuracy than both, Topcon and SW-net, for the estimates of three clinical parameters: cell density (ECD), polymegethism (CV), and pleomorphism (HEX). The mean relative error in U-net for the parameters is 0.4% in ECD, 2.8% in CV, and 1.3% in HEX. The computation time to segment an image and estimate the parameters is barely a few seconds. Both methods presented here provide a statistically significant improvement over the state of the art. U-net has reached the smallest error rate. We suggest a segmentation refinement based on our previous work to further improve the performance.
- 6 June 2018
- Published by Springer Nature
- p. 631-638
Improved Accuracy and Robustness of a Corneal Endothelial Cell Segmentation Method Based on Merging Superpixels
- 6 June 2018
- Published by Springer Nature
- p. 631-638
Improved Accuracy and Robustness of a Corneal Endothelial Cell Segmentation Method Based on Merging Superpixels
- Open Access
- 29 May 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Imaging
- Vol. 37 (10) , 2278-2289
Corneal Endothelial Cell Segmentation by Classifier-Driven Merging of Oversegmented Images
Corneal endothelium images obtained by in vivo specular microscopy provide important information to assess the health status of the cornea. Estimation of clinical parameters, such as cell density, polymegethism, and pleomorphism, requires accurate cell segmentation. State-of-the-art techniques to automatically segment the endothelium are error-prone when applied to images with low contrast and/or large variation in cell size. Here, we propose an automatic method to segment the endothelium. Starting with an oversegmented image comprised of superpixels obtained from a stochastic watershed segmentation, the proposed method uses intensity and shape information of the superpixels to identify and merge those that constitute a cell, using Support Vector Machines. We evaluated the automatic segmentation on a dataset of in vivo specular microscopy images (Topcon SP-1P), obtaining 95.8merged cells and 2.0the parameter estimation against the results of the vendor’s builtin software, obtaining a statistically significant better precision in all parameters and a similar or better accuracy. The parameter estimation was also evaluated on three other datasets from different imaging modalities (confocal microscopy, phasecontrast microscopy, and fluorescence confocal microscopy) and tissue types (ex vivo corneal endothelium and retinal pigment epithelium). In comparison with the estimates of the datasets’ authors, we achieved statistically significant better accuracy and precision in all parameters except pleomorphism, where a similar accuracy and precision were obtained.
- 29 May 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Imaging
- Vol. 37 (10) , 2278-2289
Open AccessCorneal Endothelial Cell Segmentation by Classifier-Driven Merging of Oversegmented Images
Corneal endothelium images obtained by in vivo specular microscopy provide important information to assess the health status of the cornea. Estimation of clinical parameters, such as cell density, polymegethism, and pleomorphism, requires accurate cell segmentation. State-of-the-art techniques to automatically segment the endothelium are error-prone when applied to images with low contrast and/or large variation in cell size. Here, we propose an automatic method to segment the endothelium. Starting with an oversegmented image comprised of superpixels obtained from a stochastic watershed segmentation, the proposed method uses intensity and shape information of the superpixels to identify and merge those that constitute a cell, using Support Vector Machines. We evaluated the automatic segmentation on a dataset of in vivo specular microscopy images (Topcon SP-1P), obtaining 95.8merged cells and 2.0the parameter estimation against the results of the vendor’s builtin software, obtaining a statistically significant better precision in all parameters and a similar or better accuracy. The parameter estimation was also evaluated on three other datasets from different imaging modalities (confocal microscopy, phasecontrast microscopy, and fluorescence confocal microscopy) and tissue types (ex vivo corneal endothelium and retinal pigment epithelium). In comparison with the estimates of the datasets’ authors, we achieved statistically significant better accuracy and precision in all parameters except pleomorphism, where a similar accuracy and precision were obtained.
- Open Access
- 1 October 2017
- Published by Elsevier in Ophthalmology
- Vol. 124 (10) , 1510-1522
Preoperative Posturing of Patients with Macula-On Retinal Detachment Reduces Progression Toward the Fovea
- 1 October 2017
- Published by Elsevier in Ophthalmology
- Vol. 124 (10) , 1510-1522
Open AccessPreoperative Posturing of Patients with Macula-On Retinal Detachment Reduces Progression Toward the Fovea