Fumiya Yoneyama
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Fumiya Yoneyama has a total of 48 co-authors. Here are the top co-authors by number of shared publications:
Michiaki Imamura
Congenital Heart Surgery, Texas Children’s Hospital, Baylor College of Medicine , Houston, TX 77030
7 shared publicationsToru Okamura
Department of Cardiovascular Surgery, Pediatrics Cardiology, Nagano Children's Hospital, Toyoshina, Azumino, Nagano, 3100, Japan
5 shared publicationsHiroaki Sakamoto
Department of Cardiovascular Surgery, University of Tsukuba Hospital, Tsukuba, Ibaraki, Japan
4 shared publicationsJavier Brenes
Congenital Heart Surgery, Texas Children’s Hospital, Austin, USA
4 shared publicationsYuji Hiramatsu
Department of Cardiovascular Surgery, University of Tsukuba Hospital, Tsukuba, Ibaraki, Japan
4 shared publicationsFujio Sato
Department of Cardiovascular Surgery, Tsukuba Medical Center Hospital, Tsukuba, Ibaraki, Japan
3 shared publications
Latest Publications
- Open Access
- 10 March 2026
- Published by Springer Nature in Journal of Cardiothoracic Surgery
- Vol. 21 (1)
Surgical repair of isolated right pulmonary artery using pulmonary artery flap and preserved PDA stent
Isolated right pulmonary artery (RPA) from the ductus arteriosus is rare and often managed in stages to promote vessel growth. We present a 12-year-old girl with ductal-origin RPA who had undergone patent ductus arteriosus (PDA) stenting at age three and serial balloon dilations. Through median sternotomy, a posterior wall flap was created from the main pulmonary artery (MPA) and rotated toward the RPA, incorporating the preserved stented PDA segment as the posterior wall. The anterior wall was reconstructed with a decellularized pulmonary homograft patch, creating a 9 mm lumen. The patient recovered uneventfully, and postoperative imaging confirmed a widely patent RPA without a gradient. Preserving the PDA stent and combining it with an MPA flap and homograft augmentation offered a durable repair for long-gap ductal-origin RPA, avoiding synthetic conduit use and minimizing dissection.
- 10 March 2026
- Published by Springer Nature in Journal of Cardiothoracic Surgery
- Vol. 21 (1)
Open AccessSurgical repair of isolated right pulmonary artery using pulmonary artery flap and preserved PDA stent
Isolated right pulmonary artery (RPA) from the ductus arteriosus is rare and often managed in stages to promote vessel growth. We present a 12-year-old girl with ductal-origin RPA who had undergone patent ductus arteriosus (PDA) stenting at age three and serial balloon dilations. Through median sternotomy, a posterior wall flap was created from the main pulmonary artery (MPA) and rotated toward the RPA, incorporating the preserved stented PDA segment as the posterior wall. The anterior wall was reconstructed with a decellularized pulmonary homograft patch, creating a 9 mm lumen. The patient recovered uneventfully, and postoperative imaging confirmed a widely patent RPA without a gradient. Preserving the PDA stent and combining it with an MPA flap and homograft augmentation offered a durable repair for long-gap ductal-origin RPA, avoiding synthetic conduit use and minimizing dissection.
- 30 October 2025
- Published by SAGE Publications in Perfusion
- Vol. 41 (5) , 519-534
Quality indicators in pediatric cardiopulmonary bypass: Current perspectives and future directions
Introduction: Cardiopulmonary bypass (CPB) plays a central role in pediatric cardiac surgery, yet standardized quality indicators (QIs) specific to pediatric practice remain underutilized across institutions. Methods: A comprehensive review of literature from 2010 to 2025 was conducted using PubMed, Embase, and the Cochrane Library. Eligible studies included randomized trials, observational research, and meta-analyses. Results: DO 2 i > 340 mL/min/m 2 in neonates and >400 mL/min/m 2 in infants was associated with a lower risk of acute kidney injury (AKI). Lactate >3 mmol/L predicted major morbidity, while MAP >40–45 mmHg correlated with adequate perfusion. Maintaining Hct ≥25% and a fluid balance within ±5% of baseline also supported improved postoperative outcomes. The integration of real-time multimodal monitoring, including NIRS and venous oxygen metrics, enhances individualized perfusion management. Conclusion: Adopting and standardizing QIs in pediatric CPB supports early detection of inadequate perfusion and enhances surgical safety. A structured, multimodal QI framework can facilitate institutional benchmarking, improve patient outcomes, and guide future innovation in pediatric perfusion practices.
- 30 October 2025
- Published by SAGE Publications in Perfusion
- Vol. 41 (5) , 519-534
Quality indicators in pediatric cardiopulmonary bypass: Current perspectives and future directions
Introduction: Cardiopulmonary bypass (CPB) plays a central role in pediatric cardiac surgery, yet standardized quality indicators (QIs) specific to pediatric practice remain underutilized across institutions. Methods: A comprehensive review of literature from 2010 to 2025 was conducted using PubMed, Embase, and the Cochrane Library. Eligible studies included randomized trials, observational research, and meta-analyses. Results: DO 2 i > 340 mL/min/m 2 in neonates and >400 mL/min/m 2 in infants was associated with a lower risk of acute kidney injury (AKI). Lactate >3 mmol/L predicted major morbidity, while MAP >40–45 mmHg correlated with adequate perfusion. Maintaining Hct ≥25% and a fluid balance within ±5% of baseline also supported improved postoperative outcomes. The integration of real-time multimodal monitoring, including NIRS and venous oxygen metrics, enhances individualized perfusion management. Conclusion: Adopting and standardizing QIs in pediatric CPB supports early detection of inadequate perfusion and enhances surgical safety. A structured, multimodal QI framework can facilitate institutional benchmarking, improve patient outcomes, and guide future innovation in pediatric perfusion practices.
- Open Access
- 24 October 2025
- Published by Oxford University Press (OUP) in Interdisciplinary CardioVascular and Thoracic Surgery
- Vol. 40 (11)
Dual-Patch Technique with Ventricular Septal Defect Closure for Straddling Chordae
Surgical repair of ventricular septal defects (VSDs) with straddling atrioventricular (AV) valve chordae is challenging due to the risk of disrupting valve integrity. We report the successful use of a dual-patch technique in a 5-month-old girl (6.1 kg) with Down syndrome, presenting with a large inlet VSD, secundum atrial septal defect (ASD), and straddling chordae involving both AV valves. Ventricular septal defects closure was performed via right atriotomy using 2 glutaraldehyde-treated autologous pericardial patches placed on the superior and inferior septal margins, encasing the chordae without division. Mitral and tricuspid valve clefts were repaired, and the ASD was closed primarily. Postoperative echocardiography showed no residual VSD and only mild AV valve regurgitation. This approach preserved valvular geometry and avoided conduction disturbance. The dual-patch technique offers a physiologic and conservative solution when conventional VSD repair is precluded by straddling chordae. It avoids chordal translocation or reimplantation, maintaining the native architecture and function of the AV valves.
- 24 October 2025
- Published by Oxford University Press (OUP) in Interdisciplinary CardioVascular and Thoracic Surgery
- Vol. 40 (11)
Open AccessDual-Patch Technique with Ventricular Septal Defect Closure for Straddling Chordae
Surgical repair of ventricular septal defects (VSDs) with straddling atrioventricular (AV) valve chordae is challenging due to the risk of disrupting valve integrity. We report the successful use of a dual-patch technique in a 5-month-old girl (6.1 kg) with Down syndrome, presenting with a large inlet VSD, secundum atrial septal defect (ASD), and straddling chordae involving both AV valves. Ventricular septal defects closure was performed via right atriotomy using 2 glutaraldehyde-treated autologous pericardial patches placed on the superior and inferior septal margins, encasing the chordae without division. Mitral and tricuspid valve clefts were repaired, and the ASD was closed primarily. Postoperative echocardiography showed no residual VSD and only mild AV valve regurgitation. This approach preserved valvular geometry and avoided conduction disturbance. The dual-patch technique offers a physiologic and conservative solution when conventional VSD repair is precluded by straddling chordae. It avoids chordal translocation or reimplantation, maintaining the native architecture and function of the AV valves.
- Open Access
- 20 August 2025
- Published by Elsevier in Annals of Thoracic Surgery Short Reports
- Vol. 4 (1) , 167-170
Surgical Repair of Double-Outlet Right Ventricle With Doubly Committed Juxtaarterial Ventricular Septal Defect: The Role of Virtual Reality
- 20 August 2025
- Published by Elsevier in Annals of Thoracic Surgery Short Reports
- Vol. 4 (1) , 167-170
Open AccessSurgical Repair of Double-Outlet Right Ventricle With Doubly Committed Juxtaarterial Ventricular Septal Defect: The Role of Virtual Reality
- 19 May 2025
- Published by Cambridge University Press (CUP) in Cardiology in the Young
- Vol. 35 (6) , 1237-1238
Endoscopic visualisation in the surgical repair of an aorto–left ventricular tunnel in a neonate
Aorto–left ventricular tunnel is a rare congenital cardiac anomaly characterised by an extracardiac channel connecting the ascending aorta directly to the left ventricle. Surgical repair in neonates poses significant challenges due to the diminutive size and close proximity of critical structures such as the aortic valve and coronary ostia. We report the case of a neonate with an aorto–left ventricular tunnel, mild left ventricular dysfunction, and mild aortic insufficiency who underwent successful surgical repair on the sixth day of life. Following cardiopulmonary bypass initiation and cardioplegic arrest, the ascending aorta was transected for direct visualisation. A 5-mm 0° rigid endoscope was employed intraoperatively, providing high-resolution magnification of the aortic valve, right coronary artery, and tunnel anatomy. The tunnel was closed using an autologous pericardial patch, ensuring preservation of the coronary ostium and aortic valve integrity. Postoperative echocardiography demonstrated good left ventricular function, trivial aortic insufficiency, and no residual shunt. The use of rigid endoscopy significantly enhanced the safety and precision of the repair by allowing accurate anatomical delineation and facilitating patch placement. This case highlights the importance of detailed visualisation in neonatal aorto–left ventricular tunnel repair and underscores the utility of rigid endoscopic technology in complex congenital heart surgery. Endoscopic assistance not only aids intraoperative decision-making but also serves as a valuable tool for surgical education and postoperative review.
- 19 May 2025
- Published by Cambridge University Press (CUP) in Cardiology in the Young
- Vol. 35 (6) , 1237-1238
Endoscopic visualisation in the surgical repair of an aorto–left ventricular tunnel in a neonate
Aorto–left ventricular tunnel is a rare congenital cardiac anomaly characterised by an extracardiac channel connecting the ascending aorta directly to the left ventricle. Surgical repair in neonates poses significant challenges due to the diminutive size and close proximity of critical structures such as the aortic valve and coronary ostia. We report the case of a neonate with an aorto–left ventricular tunnel, mild left ventricular dysfunction, and mild aortic insufficiency who underwent successful surgical repair on the sixth day of life. Following cardiopulmonary bypass initiation and cardioplegic arrest, the ascending aorta was transected for direct visualisation. A 5-mm 0° rigid endoscope was employed intraoperatively, providing high-resolution magnification of the aortic valve, right coronary artery, and tunnel anatomy. The tunnel was closed using an autologous pericardial patch, ensuring preservation of the coronary ostium and aortic valve integrity. Postoperative echocardiography demonstrated good left ventricular function, trivial aortic insufficiency, and no residual shunt. The use of rigid endoscopy significantly enhanced the safety and precision of the repair by allowing accurate anatomical delineation and facilitating patch placement. This case highlights the importance of detailed visualisation in neonatal aorto–left ventricular tunnel repair and underscores the utility of rigid endoscopic technology in complex congenital heart surgery. Endoscopic assistance not only aids intraoperative decision-making but also serves as a valuable tool for surgical education and postoperative review.
- 18 March 2024
- Published by Elsevier in The Journal of Heart and Lung Transplantation
- Vol. 43 (7) , 1193-1195
Incidental finding and treatment of an anomalous aortic origin of the right coronary artery in a pediatric donor’s heart prior to implantation
- 18 March 2024
- Published by Elsevier in The Journal of Heart and Lung Transplantation
- Vol. 43 (7) , 1193-1195
Incidental finding and treatment of an anomalous aortic origin of the right coronary artery in a pediatric donor’s heart prior to implantation
- 11 March 2024
- Published by SAGE Publications in World Journal for Pediatric and Congenital Heart Surgery
- Vol. 15 (4) , 432-438
Long-Term Outcomes of Ascending Sliding Arch Aortoplasty
Background: Coarctation of the aorta can be associated with significant hypoplasia of the aortic arch. In contrast to patch aortoplasty, ascending sliding arch aortoplasty uses viable autologous tissue for potential growth in children. We reviewed the mid- to long-term outcomes of this technique. Methods: Between 2002 and 2023, 28 patients underwent ascending sliding arch aortoplasty for the patients with coarctation of the aorta (n = 22) and interrupted aortic arch (n = 2). Four patients underwent previous surgical coarctation repair at other institutions. The median patient age and body weight were 28.5 months (3 weeks to 15.6 years) and 13.4 kg (3.7-70 kg), respectively. Results: Although one patient had a recurrent nerve injury postoperatively, there were no other major morbidities or mortalities. The last follow-up echocardiography demonstrated that the mean peak velocity improved from 3.9 ± 0.6 to 0.9 ± 0.8 m/s, and the pressure gradient improved from 63.6 ± 21.5 to 7.1 ± 7.7 mm Hg. The postoperative diameters of the ascending aorta, proximal arch, distal arch, and isthmus all increased significantly. The mean postoperative length of stay was 5.9 ± 2.1 days, and the median follow-up time was 7.3 years (10 days to 20.5 years). No reoperation or catheterization-based intervention was performed for residual coarctation. Conclusions: Ascending sliding arch aortoplasty is safe and effective for treating coarctation of the aorta with aortic arch hypoplasia. This technique is applicable for children ranging in size from neonates to older children (or adolescents), recurrent coarctation cases, and provides complete relief of narrowing by utilizing viable native aortic tissue.
- 11 March 2024
- Published by SAGE Publications in World Journal for Pediatric and Congenital Heart Surgery
- Vol. 15 (4) , 432-438
Long-Term Outcomes of Ascending Sliding Arch Aortoplasty
Background: Coarctation of the aorta can be associated with significant hypoplasia of the aortic arch. In contrast to patch aortoplasty, ascending sliding arch aortoplasty uses viable autologous tissue for potential growth in children. We reviewed the mid- to long-term outcomes of this technique. Methods: Between 2002 and 2023, 28 patients underwent ascending sliding arch aortoplasty for the patients with coarctation of the aorta (n = 22) and interrupted aortic arch (n = 2). Four patients underwent previous surgical coarctation repair at other institutions. The median patient age and body weight were 28.5 months (3 weeks to 15.6 years) and 13.4 kg (3.7-70 kg), respectively. Results: Although one patient had a recurrent nerve injury postoperatively, there were no other major morbidities or mortalities. The last follow-up echocardiography demonstrated that the mean peak velocity improved from 3.9 ± 0.6 to 0.9 ± 0.8 m/s, and the pressure gradient improved from 63.6 ± 21.5 to 7.1 ± 7.7 mm Hg. The postoperative diameters of the ascending aorta, proximal arch, distal arch, and isthmus all increased significantly. The mean postoperative length of stay was 5.9 ± 2.1 days, and the median follow-up time was 7.3 years (10 days to 20.5 years). No reoperation or catheterization-based intervention was performed for residual coarctation. Conclusions: Ascending sliding arch aortoplasty is safe and effective for treating coarctation of the aorta with aortic arch hypoplasia. This technique is applicable for children ranging in size from neonates to older children (or adolescents), recurrent coarctation cases, and provides complete relief of narrowing by utilizing viable native aortic tissue.
- 4 May 2023
- Published by Cambridge University Press (CUP) in Cardiology in the Young
- Vol. 33 (11) , 2369-2374
Comprehensive management of type A acute aortic dissection in the paediatric population with ACTA 2 mutation: case reports and literature review of paediatric aortic dissection
Acute aortic dissection in the paediatric population is rare but lethal. We present two paediatric cases of type A acute aortic dissection that required emergent procedures and were later found to have genetic mutations. High index of suspicion, early clinical diagnosis, prompt treatment, the advantageous collaboration between the paediatric team and aortic surgeons, and familial genetic testing are paramount to achieve a good outcome.
- 4 May 2023
- Published by Cambridge University Press (CUP) in Cardiology in the Young
- Vol. 33 (11) , 2369-2374
Comprehensive management of type A acute aortic dissection in the paediatric population with ACTA 2 mutation: case reports and literature review of paediatric aortic dissection
Acute aortic dissection in the paediatric population is rare but lethal. We present two paediatric cases of type A acute aortic dissection that required emergent procedures and were later found to have genetic mutations. High index of suspicion, early clinical diagnosis, prompt treatment, the advantageous collaboration between the paediatric team and aortic surgeons, and familial genetic testing are paramount to achieve a good outcome.
- 25 September 2022
- Published by SAGE Publications in Perfusion
- Vol. 38 (8) , 1565-1567
Retrograde cerebral perfusion for intracardiac air embolism in Fontan procedure
We report the case of a 5-year-old boy who suffered from an intracardiac air influx with suspected cerebral air embolism during the Fontan procedure. We immediately transformed the cardiopulmonary bypass circuit to perform a retrograde cerebral perfusion, which resulted in successful neuroprotection. He was extubated in the operating room without any neurological defects.
- 25 September 2022
- Published by SAGE Publications in Perfusion
- Vol. 38 (8) , 1565-1567
Retrograde cerebral perfusion for intracardiac air embolism in Fontan procedure
We report the case of a 5-year-old boy who suffered from an intracardiac air influx with suspected cerebral air embolism during the Fontan procedure. We immediately transformed the cardiopulmonary bypass circuit to perform a retrograde cerebral perfusion, which resulted in successful neuroprotection. He was extubated in the operating room without any neurological defects.
- 2 September 2022
- Published by Oxford University Press (OUP) in European Journal of Cardio-Thoracic Surgery
- Vol. 62 (4)
Modified biatrial heart transplantation after bilateral bidirectional cavo-pulmonary shunts
We describe a patient who underwent modified biatrial anastomosis heart transplantation after the bilateral Glenn procedure. We introduced a new surgical technique to use the native central pulmonary artery as systemic venous return, which was anastomosed to right atrium, and then, biatrial anastomosis was performed.
- 2 September 2022
- Published by Oxford University Press (OUP) in European Journal of Cardio-Thoracic Surgery
- Vol. 62 (4)
Modified biatrial heart transplantation after bilateral bidirectional cavo-pulmonary shunts
We describe a patient who underwent modified biatrial anastomosis heart transplantation after the bilateral Glenn procedure. We introduced a new surgical technique to use the native central pulmonary artery as systemic venous return, which was anastomosed to right atrium, and then, biatrial anastomosis was performed.