Danail Stoyanov
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Danail Stoyanov has a total of 1000 co-authors. Here are the top co-authors by number of shared publications:
- Dale Jonathan Waterhouse
University of Cambridge
37 shared publications - Evangelos B. Mazomenos
University College London
37 shared publications - Paolo De Coppi
Department of Development and Regeneration, Cluster Woman and Child, Biomedical Sciences, My FetUZ Fetal Research Center, KU Leuven, Leuven, Belgium
37 shared publications - Stefano Giuliani
Cancer Section, Developmental Biology and Cancer Programme, University College London Great Ormond Street Institute of Child Health, London, UK; Department of Specialist Neonatal and Paediatric Surgery, Great Ormond Street Hospital for Children, NHS Foundation Trust, London, UK; UCL Hakwes Institute, University College London, London, UK
35 shared publications - Alessandra Preziosi
Pediatric Surgery, ASST Grande Ospedale Metropolitano Niguarda, 20162 Milan, Italy
34 shared publications - Chiara Da Pieve
Department of Radiotherapy and Imaging, Institute of Cancer Research , London
34 shared publications
Latest Publications
- 1 October 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Robotics and Automation Letters
- Vol. 11 (10) , 11251-11258
Diff2DGS: Reliable Reconstruction of Occluded Surgical Scenes via 2D Gaussian Splatting
- 1 October 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Robotics and Automation Letters
- Vol. 11 (10) , 11251-11258
Diff2DGS: Reliable Reconstruction of Occluded Surgical Scenes via 2D Gaussian Splatting
- Open Access
- 24 September 2026
- Published by IOP Publishing in Biomedical Physics & Engineering Express
- Vol. 12 (5) , 055024
Tomographic quality evaluation of flexible x-ray scintillating imaging skins
Objective. Detecting abnormal tissue in minimally invasive surgery is challenging due to the lack of direct palpation for the surgeon, with visualisation often being limited to white light endoscope images of the tissue surface, providing no information about inner structures. Imaging skins are being explored as a novel method of surgical image guidance: they are flexible and stretchable scintillating films that can act as indirect x-ray detectors when placed directly on the organ surface. Approach. Tomographic imaging of a custom quality evaluation phantom was performed using the imaging skin system. Image quality metrics, including spatial resolution, contrast, and uniformity, were obtained and compared to a conventional flat-panel micro-CT system. Main results. The imaging skin scan achieved a spatial resolution of 3.11 lp mm − 1 at 10% contrast. While these results were worse than that of the micro-CT system, the imaging skin system still met the requirements for clinical CT, demonstrating its clinical suitability. Significance. The feasibility of 3D x-ray imaging using imaging skins directly placed onto the imaged object has been demonstrated, achieving high resolution, comparable to clinical CT. Future work will involve artefact corrections and more advanced reconstruction techniques for the intended application of imaging skins for real-time surgical guidance.
- 24 September 2026
- Published by IOP Publishing in Biomedical Physics & Engineering Express
- Vol. 12 (5) , 055024
Open AccessTomographic quality evaluation of flexible x-ray scintillating imaging skins
Objective. Detecting abnormal tissue in minimally invasive surgery is challenging due to the lack of direct palpation for the surgeon, with visualisation often being limited to white light endoscope images of the tissue surface, providing no information about inner structures. Imaging skins are being explored as a novel method of surgical image guidance: they are flexible and stretchable scintillating films that can act as indirect x-ray detectors when placed directly on the organ surface. Approach. Tomographic imaging of a custom quality evaluation phantom was performed using the imaging skin system. Image quality metrics, including spatial resolution, contrast, and uniformity, were obtained and compared to a conventional flat-panel micro-CT system. Main results. The imaging skin scan achieved a spatial resolution of 3.11 lp mm − 1 at 10% contrast. While these results were worse than that of the micro-CT system, the imaging skin system still met the requirements for clinical CT, demonstrating its clinical suitability. Significance. The feasibility of 3D x-ray imaging using imaging skins directly placed onto the imaged object has been demonstrated, achieving high resolution, comparable to clinical CT. Future work will involve artefact corrections and more advanced reconstruction techniques for the intended application of imaging skins for real-time surgical guidance.
- Open Access
- 7 September 2026
- Published by Elsevier in Medical Image Analysis
- Vol. 115
Federated Learning for surgical vision in appendicitis classification: Results of the FedSurg EndoVis 2024 challenge
- 7 September 2026
- Published by Elsevier in Medical Image Analysis
- Vol. 115
Open AccessFederated Learning for surgical vision in appendicitis classification: Results of the FedSurg EndoVis 2024 challenge
- Open Access
- 29 August 2026
- Published by Elsevier in Medical Image Analysis
- Vol. 114
SEDCLIP: Adapting vision-language model for multi-label surgical error detection
- 29 August 2026
- Published by Elsevier in Medical Image Analysis
- Vol. 114
Open AccessSEDCLIP: Adapting vision-language model for multi-label surgical error detection
- Open Access
- 22 July 2026
- Published by Elsevier in Journal of Pediatric Surgery
- p. 163320
Indocyanine Green Fluorescence Cholangiography Enables Safe Laparoscopic Near-Total Pancreatectomy for Diffuse Congenital Hyperinsulinism
- 22 July 2026
- Published by Elsevier in Journal of Pediatric Surgery
- p. 163320
Open AccessIndocyanine Green Fluorescence Cholangiography Enables Safe Laparoscopic Near-Total Pancreatectomy for Diffuse Congenital Hyperinsulinism
- 12 June 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. PP (1530437X) , 1
A Compact High-Performance MR Safe Pneumatic Stepper Motor
Magnetic resonance imaging (MRI)-guided interventions have advanced rapidly due to their superior soft-tissue contrast and real-time imaging capability. To enable actuation for robots and other medical devices used in tumour biopsy and ablation within magnetically sensitive environments, several MRI-compatible pneumatic motors have been developed using 3D printing. Although 3D printing enables the fabrication of pneumatic structures, maintaining airtightness and smooth piston motion within 3D-printed cylinders remains challenging due to tolerance variations and surface roughness. These issues lead to pressure losses, increased air consumption, and reduced torque output during motor operation. To address these challenges, this paper presents a compact, high-performance, easily manufacturable MR Safe pneumatic stepper motor that circumvents 3D-printing tolerance limitations by employing prefabricated cylinders. The motor combines a replaceable design with great airtightness and high torque performance. The proposed design achieves negligible air leakage of 0.047 mL/min measured via a designed water displacement method and a maximum output torque of 1.04 Nm at 3.7 revolutions per minute (rpm) under 6 bar, without an additional gearbox. The motor has a compact design, 48 × 48 × 36 mm, which enables the motor to be integrated into the medical devices within the narrow MRI scanning bore.
- 12 June 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. PP (1530437X) , 1
A Compact High-Performance MR Safe Pneumatic Stepper Motor
Magnetic resonance imaging (MRI)-guided interventions have advanced rapidly due to their superior soft-tissue contrast and real-time imaging capability. To enable actuation for robots and other medical devices used in tumour biopsy and ablation within magnetically sensitive environments, several MRI-compatible pneumatic motors have been developed using 3D printing. Although 3D printing enables the fabrication of pneumatic structures, maintaining airtightness and smooth piston motion within 3D-printed cylinders remains challenging due to tolerance variations and surface roughness. These issues lead to pressure losses, increased air consumption, and reduced torque output during motor operation. To address these challenges, this paper presents a compact, high-performance, easily manufacturable MR Safe pneumatic stepper motor that circumvents 3D-printing tolerance limitations by employing prefabricated cylinders. The motor combines a replaceable design with great airtightness and high torque performance. The proposed design achieves negligible air leakage of 0.047 mL/min measured via a designed water displacement method and a maximum output torque of 1.04 Nm at 3.7 revolutions per minute (rpm) under 6 bar, without an additional gearbox. The motor has a compact design, 48 × 48 × 36 mm, which enables the motor to be integrated into the medical devices within the narrow MRI scanning bore.
- Open Access
- 1 June 2026
- Published by Springer Nature in International Journal of Computer Assisted Radiology and Surgery
- Vol. 21 (7) , 1485-1494
Blob representation of robotic surgical scenes for position-aware video generation
Purpose: Synthetic video generation offers substantial promise for AI development in robot-assisted minimally invasive surgery (RMIS), addressing the limited availability of annotated datasets. We present a novel approach for realistic and controllable RMIS video generation, leveraging robot kinematics to constrain the spatial position of the surgical tools in the generated frames. Methods: Our architecture uses a Blob Generation module that transforms 3D kinematic data into rigid 2D blob representations for spatial conditioning of a Frame Generation module using an encoder–decoder with temporal retention. Results: Quantitative and qualitative evaluations on the suturing task of the JIGSAWS benchmark dataset demonstrate that our approach enhances both video fidelity and positional accuracy of the surgical tools over long sequences. Blob spatial accuracy against pseudo-ground-truth labels yields average bounding box and mask Dice scores of 0.78 and 0.71, respectively, while video synthesis improves on average by 2% and 5% for SSIM and 4% and 9% for PSNR, while LPIPS reduces by 9% and 20%, compared to baseline state-of-the-art auto-regressive approaches for frames generated at $$t+10$$ and $$t+20$$ . Conclusion: These results validate the potential of blob representation for position-aware, realistic video generation in RMIS. Synthesized data can augment available datasets, benefiting downstream tasks such as instrument tracking, workflow/skill analysis and robotic automation.- 1 June 2026
- Published by Springer Nature in International Journal of Computer Assisted Radiology and Surgery
- Vol. 21 (7) , 1485-1494
Open AccessBlob representation of robotic surgical scenes for position-aware video generation
Purpose: Synthetic video generation offers substantial promise for AI development in robot-assisted minimally invasive surgery (RMIS), addressing the limited availability of annotated datasets. We present a novel approach for realistic and controllable RMIS video generation, leveraging robot kinematics to constrain the spatial position of the surgical tools in the generated frames. Methods: Our architecture uses a Blob Generation module that transforms 3D kinematic data into rigid 2D blob representations for spatial conditioning of a Frame Generation module using an encoder–decoder with temporal retention. Results: Quantitative and qualitative evaluations on the suturing task of the JIGSAWS benchmark dataset demonstrate that our approach enhances both video fidelity and positional accuracy of the surgical tools over long sequences. Blob spatial accuracy against pseudo-ground-truth labels yields average bounding box and mask Dice scores of 0.78 and 0.71, respectively, while video synthesis improves on average by 2% and 5% for SSIM and 4% and 9% for PSNR, while LPIPS reduces by 9% and 20%, compared to baseline state-of-the-art auto-regressive approaches for frames generated at $$t+10$$ and $$t+20$$ . Conclusion: These results validate the potential of blob representation for position-aware, realistic video generation in RMIS. Synthesized data can augment available datasets, benefiting downstream tasks such as instrument tracking, workflow/skill analysis and robotic automation. - 1 June 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Imaging
- Vol. 45 (6) , 2750-2763
AnatoDiff: Synthesizing Anatomically Truthful Radiographs With Limited Training Images
Rapid advancements in diffusion models have enabled synthesis of realistic and anonymized imagery in radiography. However, due to their complexity, these models typically require large training volumes, often exceeding 10,000 images. Pre-training on natural images can partly mitigate this issue, but often fails to generate anatomically accurate shapes due to the significant domain gap. This prohibits applications in specialized medical conditions with limited data. We propose AnatoDiff, a diffusion model synthesizing high-quality X-Ray images with accurate anatomical shapes using only 500 to 1,000 training samples. AnatoDiff incorporates a Shape Prototype Module and Anatomical Fidelity loss, allowing for smaller training volumes through targeted supervision. We extensively validate AnatoDiff across three open-source datasets from distinct anatomical regions: Neonatal Abdomen (1,000 images); Adult Chest (500 images); and Humerus (500 images). Results demonstrate significant benefits, with an average improvement of 14.9% in Fréchet Inception Distance, 9.7% in Improved Precision, and 2.3% in Improved Recall compared to state-of-the-art (SOTA) few-shot and data-limited natural image synthesis methods. Unlike other models, AnatoDiff consistently generates anatomically correct images with accurate shapes. Additionally, a ResNet-50 classifier trained on AnatoDiff-generated images shows a 2.1% to 5.3% increase in F1-score, compared to being trained on SOTA diffusion images, across 500 to 10,000 samples. A survey with 10 medical professionals reveals that images generated by AnatoDiff are challenging to distinguish from real ones, with a Matthews correlation coefficient of 0.277 and Fleiss' Kappa of 0.126, highlighting the effectiveness of AnatoDiff in generating high-quality, anatomically accurate radiographs. Our code is available at https://github.com/KawaiYung/AnatoDiff.
- 1 June 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Imaging
- Vol. 45 (6) , 2750-2763
AnatoDiff: Synthesizing Anatomically Truthful Radiographs With Limited Training Images
Rapid advancements in diffusion models have enabled synthesis of realistic and anonymized imagery in radiography. However, due to their complexity, these models typically require large training volumes, often exceeding 10,000 images. Pre-training on natural images can partly mitigate this issue, but often fails to generate anatomically accurate shapes due to the significant domain gap. This prohibits applications in specialized medical conditions with limited data. We propose AnatoDiff, a diffusion model synthesizing high-quality X-Ray images with accurate anatomical shapes using only 500 to 1,000 training samples. AnatoDiff incorporates a Shape Prototype Module and Anatomical Fidelity loss, allowing for smaller training volumes through targeted supervision. We extensively validate AnatoDiff across three open-source datasets from distinct anatomical regions: Neonatal Abdomen (1,000 images); Adult Chest (500 images); and Humerus (500 images). Results demonstrate significant benefits, with an average improvement of 14.9% in Fréchet Inception Distance, 9.7% in Improved Precision, and 2.3% in Improved Recall compared to state-of-the-art (SOTA) few-shot and data-limited natural image synthesis methods. Unlike other models, AnatoDiff consistently generates anatomically correct images with accurate shapes. Additionally, a ResNet-50 classifier trained on AnatoDiff-generated images shows a 2.1% to 5.3% increase in F1-score, compared to being trained on SOTA diffusion images, across 500 to 10,000 samples. A survey with 10 medical professionals reveals that images generated by AnatoDiff are challenging to distinguish from real ones, with a Matthews correlation coefficient of 0.277 and Fleiss' Kappa of 0.126, highlighting the effectiveness of AnatoDiff in generating high-quality, anatomically accurate radiographs. Our code is available at https://github.com/KawaiYung/AnatoDiff.
- Open Access
- 22 May 2026
- Published by Springer Nature in International Journal of Computer Assisted Radiology and Surgery
- Vol. 21 (6) , 1-9
SurgViVQA: temporally grounded video question answering for surgical scene understanding
Purpose: Video question answering (VideoQA) in the surgical domain aims to enhance intraoperative understanding by enabling AI models to reason over temporally coherent events rather than isolated frames. Current approaches are limited to static image features, and available datasets often lack temporal annotations, ignoring the dynamics critical for accurate procedural interpretation. Methods: We propose SurgViVQA, a surgical VideoQA model that extends visual reasoning from static images to dynamic surgical scenes. It uses a Masked Video–Text Encoder to fuse video and question features, capturing temporal cues like motion and tool–tissue interactions, which a fine-tuned LLM then decodes into coherent answers. To evaluate its performance, we curate REAL-Colon-VQA, a colonoscopic video dataset including motion questions and diagnostic attributes, including out-of-template questions with rephrased or semantically altered formulations to evaluate model robustness. Results: Experimental validation on REAL-Colon-VQA and the public EndoVis18-VQA dataset shows that SurgViVQA outperforms existing image-based VQA benchmark models and remains competitive with a fine-tuned video VLM baseline. In particular, SurgViVQA improves over PitVQA by +9% on REAL-Colon-VQA and +9% on EndoVis18-VQA in Keyword Accuracy, while achieving the strongest overall lexical and semantic generation performance. A perturbation study on the questions further confirms improved generalizability and robustness to variations in question phrasing. Conclusion: SurgViVQA and the REAL-Colon-VQA dataset provide a framework for temporally aware understanding in surgical VideoQA, enabling AI models to interpret dynamic procedural contexts.
- 22 May 2026
- Published by Springer Nature in International Journal of Computer Assisted Radiology and Surgery
- Vol. 21 (6) , 1-9
Open AccessSurgViVQA: temporally grounded video question answering for surgical scene understanding
Purpose: Video question answering (VideoQA) in the surgical domain aims to enhance intraoperative understanding by enabling AI models to reason over temporally coherent events rather than isolated frames. Current approaches are limited to static image features, and available datasets often lack temporal annotations, ignoring the dynamics critical for accurate procedural interpretation. Methods: We propose SurgViVQA, a surgical VideoQA model that extends visual reasoning from static images to dynamic surgical scenes. It uses a Masked Video–Text Encoder to fuse video and question features, capturing temporal cues like motion and tool–tissue interactions, which a fine-tuned LLM then decodes into coherent answers. To evaluate its performance, we curate REAL-Colon-VQA, a colonoscopic video dataset including motion questions and diagnostic attributes, including out-of-template questions with rephrased or semantically altered formulations to evaluate model robustness. Results: Experimental validation on REAL-Colon-VQA and the public EndoVis18-VQA dataset shows that SurgViVQA outperforms existing image-based VQA benchmark models and remains competitive with a fine-tuned video VLM baseline. In particular, SurgViVQA improves over PitVQA by +9% on REAL-Colon-VQA and +9% on EndoVis18-VQA in Keyword Accuracy, while achieving the strongest overall lexical and semantic generation performance. A perturbation study on the questions further confirms improved generalizability and robustness to variations in question phrasing. Conclusion: SurgViVQA and the REAL-Colon-VQA dataset provide a framework for temporally aware understanding in surgical VideoQA, enabling AI models to interpret dynamic procedural contexts.
- Open Access
- 11 May 2026
- Published by Springer Nature in International Journal of Computer Assisted Radiology and Surgery
- Vol. 21 (6) , 1-8
Imaging skins: stretchable Gd2O2S:Tb X-ray detectors for image-guided surgery
Purpose:: With the growing demands for diverse X-ray imaging applications, there is a need for the development of flexible X-ray detectors to enable conformity to curved surfaces, improving spatial resolution, reducing X-ray exposure, and extending the potential of X-ray imaging to fields such as minimally invasive surgery, which would not be achievable using conventional rigid flat-panel detectors. Methods:: In this paper, we fabricate imaging skins—flexible and stretchable Gd2O2S:Tb-elastomer scintillator films—and integrate them into an indirect X-ray imaging system. We characterise X-ray imaging performance and mechanical properties of the imaging skins, investigating the impact of varying film fabrication parameters such as thickness and concentration. Results:: The results demonstrate the clinical suitability of the imaging skin system, achieving 1.05 to 2.18 lp/mm at 10% contrast despite the low X-ray energy used, which is comparable to clinical CT. Additionally, the high stretchability (255%) from the elastomer component was maintained in imaging skins with up to 50% Gd2O2S:Tb loading. Conclusion:: This work provides a basis for the integration of imaging skins in clinical settings, where they have the potential to be used for real-time intraoperative image guidance. Future work will investigate dynamic and tomographic imaging methods, determine effective deployment strategies of the imaging skins onto organ surfaces, and investigate the effects of imaging skin deformation on image quality.
- 11 May 2026
- Published by Springer Nature in International Journal of Computer Assisted Radiology and Surgery
- Vol. 21 (6) , 1-8
Open AccessImaging skins: stretchable Gd2O2S:Tb X-ray detectors for image-guided surgery
Purpose:: With the growing demands for diverse X-ray imaging applications, there is a need for the development of flexible X-ray detectors to enable conformity to curved surfaces, improving spatial resolution, reducing X-ray exposure, and extending the potential of X-ray imaging to fields such as minimally invasive surgery, which would not be achievable using conventional rigid flat-panel detectors. Methods:: In this paper, we fabricate imaging skins—flexible and stretchable Gd2O2S:Tb-elastomer scintillator films—and integrate them into an indirect X-ray imaging system. We characterise X-ray imaging performance and mechanical properties of the imaging skins, investigating the impact of varying film fabrication parameters such as thickness and concentration. Results:: The results demonstrate the clinical suitability of the imaging skin system, achieving 1.05 to 2.18 lp/mm at 10% contrast despite the low X-ray energy used, which is comparable to clinical CT. Additionally, the high stretchability (255%) from the elastomer component was maintained in imaging skins with up to 50% Gd2O2S:Tb loading. Conclusion:: This work provides a basis for the integration of imaging skins in clinical settings, where they have the potential to be used for real-time intraoperative image guidance. Future work will investigate dynamic and tomographic imaging methods, determine effective deployment strategies of the imaging skins onto organ surfaces, and investigate the effects of imaging skin deformation on image quality.