Mohamad Khalil
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Mohamad Khalil has a total of 15 co-authors. Here are the top co-authors by number of shared publications:
- Ulrik Lund Olsen
DTU Physics, Technical University of Denmark, Kongens Lyngby, Denmark
4 shared publications - Erik Schou Dreier
FOSS Analytical A/S Hillerød Denmark
3 shared publications Jan Kehres
Technical University of Denmark, Department of Physics, Lyngby (Denmark)
2 shared publicationsMatteo Busi
Technical University of Denmark, Department of Physics, Lyngby (Denmark)
2 shared publications- Daniel Turecek
Czech Technical University in Prague
1 shared publication E.S. Dreier
University of Copenhagen, NØrregade 10 1165 Copenhagen, Denmark
1 shared publication
Latest Publications
- 1 January 2019
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 14 (01) , C01018
Intrinsic XRF corrections in Timepix3 CdTe spectral detectors
One of the limitations of Hybrid Pixel Detectors (HPD) is the intrinsic X-ray fluorescence emission from the detector semiconductor sensor. These fluorescence photons cause artifacts and false peaks in the photon energy spectrum measured by the HPD . ADVAPIX-Timepix3 is an energy dispersive HPD based on a semiconductor sensor (Si/CdTe/CZT/GaAS) and readout by a Timepix3 ASIC . Timepix3 is capable of measuring simultaneous Time-Over-Threshold (Energy) and Time-of-Arrival as well as sparse readout. This allows unambiguous one-by-one photon detection where each photon measurement is assigned a time stamp. In this work, we use the time and energy information of every single photon to identify intrinsic XRF events in a 57Co radioactive source spectrum as measured by a CdTe based detector. We compute the minimum time (ns) and space (pixels) coincidence window, between the XRF and escape photons, that is required to suppress the XRF effect. These parameters were found to be ± 15 ns and 10 pixels (pixel size = 55 μm) for 1 mm CdTe at 3000 V/cm, 24 ± 1 oC, and a flux of 1.666 × 103 photons/s before correction.
- 1 January 2019
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 14 (01) , C01018
Intrinsic XRF corrections in Timepix3 CdTe spectral detectors
One of the limitations of Hybrid Pixel Detectors (HPD) is the intrinsic X-ray fluorescence emission from the detector semiconductor sensor. These fluorescence photons cause artifacts and false peaks in the photon energy spectrum measured by the HPD . ADVAPIX-Timepix3 is an energy dispersive HPD based on a semiconductor sensor (Si/CdTe/CZT/GaAS) and readout by a Timepix3 ASIC . Timepix3 is capable of measuring simultaneous Time-Over-Threshold (Energy) and Time-of-Arrival as well as sparse readout. This allows unambiguous one-by-one photon detection where each photon measurement is assigned a time stamp. In this work, we use the time and energy information of every single photon to identify intrinsic XRF events in a 57Co radioactive source spectrum as measured by a CdTe based detector. We compute the minimum time (ns) and space (pixels) coincidence window, between the XRF and escape photons, that is required to suppress the XRF effect. These parameters were found to be ± 15 ns and 10 pixels (pixel size = 55 μm) for 1 mm CdTe at 3000 V/cm, 24 ± 1 oC, and a flux of 1.666 × 103 photons/s before correction.
- 26 October 2018
- Published by International Union of Crystallography (IUCr) in Journal of Synchrotron Radiation
- Vol. 25 (6) , 1650-1657
Subpixel resolution in CdTe Timepix3 pixel detectors
Timepix3 (256 × 256 pixels with a pitch of 55 µm) is a hybrid-pixel-detector readout chip that implements a data-driven architecture and is capable of simultaneous time-of-arrival (ToA) and energy (ToT: time-over-threshold) measurements. The ToA information allows the unambiguous identification of pixel clusters belonging to the same X-ray interaction, which allows for full one-by-one detection of photons. The weighted mean of the pixel clusters can be used to measure the subpixel position of an X-ray interaction. An experiment was performed at the European Synchrotron Radiation Facility in Grenoble, France, using a 5 µm × 5 µm pencil beam to scan a CdTe-ADVAPIX-Timepix3 pixel (55 µm × 55 µm) at 8 × 8 matrix positions with a step size of 5 µm. The head-on scan was carried out at four monochromatic energies: 24, 35, 70 and 120 keV. The subpixel position of every single photon in the beam was constructed using the weighted average of the charge spread of single interactions. Then the subpixel position of the total beam was found by calculating the mean position of all photons. This was carried out for all points in the 8 × 8 matrix of beam positions within a single pixel. The optimum conditions for the subpixel measurements are presented with regards to the cluster sizes and beam subpixel position, and the improvement of this technique is evaluated (using the charge sharing of each individual photon to achieve subpixel resolution) versus alternative techniques which compare the intensity ratio between pixels. The best result is achieved at 120 keV, where a beam step of 4.4 µm ± 0.86 µm was measured.
- 26 October 2018
- Published by International Union of Crystallography (IUCr) in Journal of Synchrotron Radiation
- Vol. 25 (6) , 1650-1657
Subpixel resolution in CdTe Timepix3 pixel detectors
Timepix3 (256 × 256 pixels with a pitch of 55 µm) is a hybrid-pixel-detector readout chip that implements a data-driven architecture and is capable of simultaneous time-of-arrival (ToA) and energy (ToT: time-over-threshold) measurements. The ToA information allows the unambiguous identification of pixel clusters belonging to the same X-ray interaction, which allows for full one-by-one detection of photons. The weighted mean of the pixel clusters can be used to measure the subpixel position of an X-ray interaction. An experiment was performed at the European Synchrotron Radiation Facility in Grenoble, France, using a 5 µm × 5 µm pencil beam to scan a CdTe-ADVAPIX-Timepix3 pixel (55 µm × 55 µm) at 8 × 8 matrix positions with a step size of 5 µm. The head-on scan was carried out at four monochromatic energies: 24, 35, 70 and 120 keV. The subpixel position of every single photon in the beam was constructed using the weighted average of the charge spread of single interactions. Then the subpixel position of the total beam was found by calculating the mean position of all photons. This was carried out for all points in the 8 × 8 matrix of beam positions within a single pixel. The optimum conditions for the subpixel measurements are presented with regards to the cluster sizes and beam subpixel position, and the improvement of this technique is evaluated (using the charge sharing of each individual photon to achieve subpixel resolution) versus alternative techniques which compare the intensity ratio between pixels. The best result is achieved at 120 keV, where a beam step of 4.4 µm ± 0.86 µm was measured.
- 25 May 2018
- Published by SPIE-Intl Soc Optical Eng in Optical Engineering
- Vol. 57 (05) , 054117-13
Spectral correction algorithm for multispectral CdTe x-ray detectors
Compared to the dual-energy scintillator detectors widely used today, energy-resolved photon-counting x-ray detectors show the potential to improve material identification in various radiography and tomography applications used for industrial and security purposes. However, detector effects, such as charge sharing and photon pileup, distort the measured spectra in pixelated, photon-counting detectors operating under high flux. These effects result in a significant performance degradation of the detectors when used for material identification where accurate spectral measurements are required. We have developed a semianalytical, postdata acquisition, computational algorithm that corrects the measured attenuation curve for severe spectral distortions caused by the detector. The calibration of the algorithm is based on simple attenuation measurements of commercially available materials using standard laboratory sources, enabling the algorithm to be used in any x-ray setup. The algorithm is developed for correcting spectral data acquired with the MultiX ME100 CdTe x-ray detector but could be adapted with small adjustments to other photon-counting, energy-resolved detectors with CdTe sensors. The validation of the algorithm has been done using experimental data acquired with both a standard laboratory source and synchrotron radiation. The experiments show that the algorithm is fast, reliable at x-ray flux up to 5 Mph / s / mm2 and greatly improves the accuracy of the measured spectrally resolved linear attenuation, making the algorithm useful for both security and industrial applications where photon-counting detectors are used.
- 25 May 2018
- Published by SPIE-Intl Soc Optical Eng in Optical Engineering
- Vol. 57 (05) , 054117-13
Spectral correction algorithm for multispectral CdTe x-ray detectors
Compared to the dual-energy scintillator detectors widely used today, energy-resolved photon-counting x-ray detectors show the potential to improve material identification in various radiography and tomography applications used for industrial and security purposes. However, detector effects, such as charge sharing and photon pileup, distort the measured spectra in pixelated, photon-counting detectors operating under high flux. These effects result in a significant performance degradation of the detectors when used for material identification where accurate spectral measurements are required. We have developed a semianalytical, postdata acquisition, computational algorithm that corrects the measured attenuation curve for severe spectral distortions caused by the detector. The calibration of the algorithm is based on simple attenuation measurements of commercially available materials using standard laboratory sources, enabling the algorithm to be used in any x-ray setup. The algorithm is developed for correcting spectral data acquired with the MultiX ME100 CdTe x-ray detector but could be adapted with small adjustments to other photon-counting, energy-resolved detectors with CdTe sensors. The validation of the algorithm has been done using experimental data acquired with both a standard laboratory source and synchrotron radiation. The experiments show that the algorithm is fast, reliable at x-ray flux up to 5 Mph / s / mm2 and greatly improves the accuracy of the measured spectrally resolved linear attenuation, making the algorithm useful for both security and industrial applications where photon-counting detectors are used.
- 14 March 2018
- Published by SPIE-Intl Soc Optical Eng in Optical Engineering
- Vol. 57 (03) , 037105-10
Simulation tools for scattering corrections in spectrally resolved x-ray computed tomography using McXtrace
Spectral computed tomography is an emerging imaging method that involves using recently developed energy discriminating photon-counting detectors (PCDs). This technique enables measurements at isolated high-energy ranges, in which the dominating undergoing interaction between the x-ray and the sample is the incoherent scattering. The scattered radiation causes a loss of contrast in the results, and its correction has proven to be a complex problem, due to its dependence on energy, material composition, and geometry. Monte Carlo simulations can utilize a physical model to estimate the scattering contribution to the signal, at the cost of high computational time. We present a fast Monte Carlo simulation tool, based on McXtrace, to predict the energy resolved radiation being scattered and absorbed by objects of complex shapes. We validate the tool through measurements using a CdTe single PCD (Multix ME-100) and use it for scattering correction in a simulation of a spectral CT. We found the correction to account for up to 7% relative amplification in the reconstructed linear attenuation. It is a useful tool for x-ray CT to obtain a more accurate material discrimination, especially in the high-energy range, where the incoherent scattering interactions become prevailing (>50 keV).
- 14 March 2018
- Published by SPIE-Intl Soc Optical Eng in Optical Engineering
- Vol. 57 (03) , 037105-10
Simulation tools for scattering corrections in spectrally resolved x-ray computed tomography using McXtrace
Spectral computed tomography is an emerging imaging method that involves using recently developed energy discriminating photon-counting detectors (PCDs). This technique enables measurements at isolated high-energy ranges, in which the dominating undergoing interaction between the x-ray and the sample is the incoherent scattering. The scattered radiation causes a loss of contrast in the results, and its correction has proven to be a complex problem, due to its dependence on energy, material composition, and geometry. Monte Carlo simulations can utilize a physical model to estimate the scattering contribution to the signal, at the cost of high computational time. We present a fast Monte Carlo simulation tool, based on McXtrace, to predict the energy resolved radiation being scattered and absorbed by objects of complex shapes. We validate the tool through measurements using a CdTe single PCD (Multix ME-100) and use it for scattering correction in a simulation of a spectral CT. We found the correction to account for up to 7% relative amplification in the reconstructed linear attenuation. It is a useful tool for x-ray CT to obtain a more accurate material discrimination, especially in the high-energy range, where the incoherent scattering interactions become prevailing (>50 keV).