JZJunhua Zhang

Junhua Zhang

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Junhua Zhang has a total of 14 co-authors. Here are the top co-authors by number of shared publications:

  • Hongjian Li

    Department of Orthopedics, The First People's Hospital of Yunnan Province, Kunming 650032, China

    3 shared publications
  • Liang Lv

    Department of Orthopedics, The First People's Hospital of Yunnan Province, Kunming 650032, China

    3 shared publications
  • Xinling Shi

    Department of Electronic Engineering, Yunnan University, Kunming, People's Republic of China

    3 shared publications
  • Yufeng Zhang

    Department of Electronic Engineering, Yunnan University, Kunming, People's Republic of China

    3 shared publications
  • Yufeng Zhang

    Yunnan University

    2 shared publications
  • Bo Yu

    Department of Ultrasound Diagnostics, First People's Hospital of Yunnan Province, Kunming, People's Republic of China

    1 shared publication

Latest Publications

  • Open Access

    Computer-Aided Cobb Measurement Based on Automatic Detection of Vertebral Slopes Using Deep Neural Network

    by Junhua Zhang, Hongjian Li, Liang Lv, Yufeng Zhang

    Objective. To develop a computer-aided method that reduces the variability of Cobb angle measurement for scoliosis assessment. Methods. A deep neural network (DNN) was trained with vertebral patches extracted from spinal model radiographs. The Cobb angle of the spinal curve was calculated automatically from the vertebral slopes predicted by the DNN. Sixty-five in vivo radiographs and 40 model radiographs were analyzed. An experienced surgeon performed manual measurements on the aforementioned radiographs. Two examiners used both the proposed and the manual measurement methods to analyze the aforementioned radiographs. Results. For model radiographs, the intraclass correlation coefficients were greater than 0.98, and the mean absolute differences were less than 3°. This indicates that the proposed system showed high repeatability for measurements of model radiographs. For the in vivo radiographs, the reliabilities were lower than those from the model radiographs, and the differences between the computer-aided measurement and the manual measurement by the surgeon were higher than 5°. Conclusion. The variability of Cobb angle measurements can be reduced if the DNN system is trained with enough vertebral patches. Training data of in vivo radiographs must be included to improve the performance of DNN. Significance. Vertebral slopes can be predicted by DNN. The computer-aided system can be used to perform automatic measurements of Cobb angle, which is used to make reliable and objective assessments of scoliosis.


  • Open Access

    Assessment of Homodyned K Distribution Modeling Ultrasonic Speckles from Scatterers with Varying Spatial Organizations

    by Xiao Hu, Yufeng Zhang, Li Deng, Guanghui Cai, Qinghui Zhang, Yi Zhou, Kexin Zhang, Junhua Zhang

    Objective. This paper presents an assessment of physical meanings of parameter and goodness of fit for homodyned K (HK) distribution modeling ultrasonic speckles from scatterer distributions with wide-varying spatial organizations. Methods. A set of 3D scatterer phantoms based on gamma distributions is built to be implemented from the clustered to random to uniform scatterer distributions continuously. The model parameters are obtained by maximum likelihood estimation (MLE) from statistical histograms of the ultrasonic envelope data and then compared with those by the optimally fitting models chosen from three single distributions. Results show that the parameters of the HK distribution still present their respective physical meanings of independent contributions in the scatterer distributions. Moreover, the HK distribution presents better goodness of fit with a maximum relative MLE difference of 6.23% for random or clustered scatterers with a well-organized periodic structure. Experiments based on ultrasonic envelope data from common carotid arterial B-mode images of human subjects validate the modeling performance of HK distribution. Conclusion. We conclude that the HK model for ultrasonic speckles is a better choice for characterizing tissue with a wide variety of spatial organizations, especially the emphasis on the goodness of fit for the tissue in practical applications.


  • Application of Computer-Aided Diagnosis to the Sonographic Evaluation of Cervical Lymph Nodes

    by Junhua Zhang, Yuanyuan Wang, Bo Yu, Xinling Shi, Yufeng Zhang

    We initiated an observer study to evaluate a computerized system developed in our previous study for automatic extraction of 10 features and estimation of the malignancy probability of cervical nodes in sonograms. In the present study, five expert radiologists and five resident radiologists interpreted the sonograms of 178 nodes. The malignancy rating and patient management recommendation (biopsy or follow-up) were made without and then with the computer aid. Under these two reading conditions, the performances of radiologists and agreement among a group of radiologists were evaluated by using the receiver operating characteristic (ROC) analysis and the κ statistic, respectively. With the computer aid, the performances of radiologists improved significantly, as indicated by the increase in the area under the ROC curve ( Az) from 0.843 to 0.896 ( p = 0.031) and from 0.705 to 0.822 ( p < 0.001), for the expert and resident groups, respectively. Agreement among all 10 radiologists improved from slight to moderate as indicated by an increase in the κ value from 0.195 to 0.421 ( p < 0.001). The average performance of residents with aid ( Az = 0.822) was close to that of experts without aid ( Az = 0.843). Results indicate that computer-aided diagnosis is useful to improve radiologist performance (especially that of inexperienced radiologists) in the ultrasonographic evaluation of cervical nodes and to reduce variability among radiologists.


  • Open Access

    Computer-aided King classification of scoliosis

    by Junhua Zhang, Hongjian Li, Liang Lv, Xinling Shi, Yufeng Zhang

    OBJECTIVE: Surgical planning for scoliosis relies on the classification of spinal curve pattern. The widely used King classification is subject to human measurement and judgment errors. To reduce the variability of King classification, a computer-aided method is proposed and its reliability is evaluated in this study. METHODS: At the first step, endplate inclination and position of each vertebra are measured by a computerized system on the posteroanterior radiograph. Based on these measurements, the apical and end vertebrae are identified and then the Cobb angles are calculated automatically. The system subsequently classifies the curve types automatically based on the computerized Cobb measurements, the vertebral inclination, and the analysis of the relationship between the center sacral vertical line, and the apical lumbar vertebra. Five observers participated in the experiments. The kappa statistic was used to evaluate the variability. RESULTS: Classifications of 105 scoliotic cases by the five observers showed that with the aid of our system, the average intraobserver and interobserver kappa values improved from 0.75 to 0.90 and from 0.66 to 0.86, respectively. CONCLUSION: Results indicate that the proposed computerized system can assist a surgeon with the King classification of scoliosis.


  • Hough transform‐based approach for estimating 3D rotation angles of vertebrae from biplanar radiographs using GPU‐acceleration

    by Junhua Zhang, Liang Lv, Xinling Shi, Fei Guo, Yufeng Zhang, Hongjian Li

    For scoliosis assessment, a system was developed to estimate the three‐dimensional (3D) rotation angles of vertebrae from biplanar radiographs. The proposed approach was based on the generalized Hough transform (GHT) technique to match the projected contours of the standard 3D primitive with vertebral edges detected in biplanar radiographs. A deformation tolerant matching strategy was proposed to extend the GHT for an inexact contour matching. The system was implemented on a graphics processing unit (GPU). Seventeen dry vertebral specimens were used to evaluate accuracy. Precision was tested by three operators on 181 vertebrae from radiographs of 15 patients. With GPU computing, the average estimation time was 10 s for a vertebra. Results showed that the 3D estimation error was less than 2.5° with the mean value of 1.6°. The intraoperator variability was within 1.6° and the interoperator variability was within 2.2°. These promising results indicate that the proposed system can help orthopedic surgeons measure the 3D vertebral rotation angles from two‐dimensional radiographs for better assessment of scoliosis. © 2013 Wiley Periodicals, Inc. Int J Imaging Syst Technol, 23, 272–279, 2013