Leanna L. Foster
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Leanna L. Foster has a total of 28 co-authors. Here are the top co-authors by number of shared publications:
- Kenichi Kuroda
Department of Biologic and Materials Sciences & Prosthodontics, School of Dentistry, University of Michigan, Ann Arbor, MI 48109, USA
3 shared publications - Christopher J. Wohl
NASA Langley Research Center
1 shared publication D.J. Horton
1 shared publicationEdmund F. Palermo
Department of Materials Science and Engineering, Rensselaer Polytechnic Institute, Troy, NY, USA
1 shared publicationH. Ha
1 shared publicationH.J. Bindig
1 shared publication
Latest Publications
- Open Access
- 10 May 2019
- Published by MDPI AG in Antibiotics
- Vol. 8 (2) , 61
Solution-Mediated Modulation of Pseudomonas aeruginosa Biofilm Formation by a Cationic Synthetic Polymer
Bacterial biofilms and their associated infections are a continuing problem in the healthcare community. Previous approaches utilizing anti-biofilm coatings suffer from short lifetimes, and their applications are limited to surfaces. In this research, we explored a new approach to biofilm prevention based on the hypothesis that changing planktonic bacteria behavior to result in sub-optimal biofilm formation. The behavior of planktonic Pseudomonas aeruginosa exposed to a cationic polymer was characterized for changes in growth behavior and aggregation behavior, and linked to resulting P. aeruginosa biofilm formation, biomass, viability, and metabolic activity. The incubation of P. aeruginosa planktonic bacteria with a cationic polymer resulted in the aggregation of planktonic bacteria, and a reduction in biofilm development. We propose that cationic polymers may sequester planktonic bacteria away from surfaces, thereby preventing their attachment and suppressing biofilm formation.
- 10 May 2019
- Published by MDPI AG in Antibiotics
- Vol. 8 (2) , 61
Open AccessSolution-Mediated Modulation of Pseudomonas aeruginosa Biofilm Formation by a Cationic Synthetic Polymer
Bacterial biofilms and their associated infections are a continuing problem in the healthcare community. Previous approaches utilizing anti-biofilm coatings suffer from short lifetimes, and their applications are limited to surfaces. In this research, we explored a new approach to biofilm prevention based on the hypothesis that changing planktonic bacteria behavior to result in sub-optimal biofilm formation. The behavior of planktonic Pseudomonas aeruginosa exposed to a cationic polymer was characterized for changes in growth behavior and aggregation behavior, and linked to resulting P. aeruginosa biofilm formation, biomass, viability, and metabolic activity. The incubation of P. aeruginosa planktonic bacteria with a cationic polymer resulted in the aggregation of planktonic bacteria, and a reduction in biofilm development. We propose that cationic polymers may sequester planktonic bacteria away from surfaces, thereby preventing their attachment and suppressing biofilm formation.
- 15 October 2018
- Published by American Chemical Society (ACS) in Biomacromolecules
- Vol. 19 (11) , 4370-4378
Decoupling the Functional Roles of Cationic and Hydrophobic Groups in the Antimicrobial and Hemolytic Activities of Methacrylate Random Copolymers
In this study, we report the antimicrobial and hemolytic activities of ternary statistical methacrylate copolymers consisting of cationic ammonium (amino-ethyl methacrylate: AEMA), hydrophobic alkyl (ethyl methacrylate: EMA), and neutral hydroxyl (hydroxyethyl methacrylate: HEMA) side chain monomers. The cationic and hydrophobic functionalities of copolymers mimic the cationic amphiphilicity of naturally occurring antimicrobial peptides (AMPs). The HEMA monomer units were used to separately modulate the compositions of cationic and hydrophobic monomers, and we investigated the effect of each component on the antimicrobial and hemolytic activities of copolymers. Our data indicated that increasing the number of cationic groups of the copolymers to be more than 30 mol % did not increase their antimicrobial activity against Escherichia coli. The number of cationic side chains in a polymer chain at this threshold is 5.5–7.7, which is comparable to those of natural antimicrobial peptides such as maginin (+6). The MIC values of copolymers with >30 mol % of AEMA depend on only the mol % of EMA, indicating that the hydrophobic interactions of the copolymers with E. coli cell membranes determine the antimicrobial activity of copolymers. These results suggest that the roles of cationic and hydrophobic groups can be controlled independently by design in the ternary copolymers studied here.
- 15 October 2018
- Published by American Chemical Society (ACS) in Biomacromolecules
- Vol. 19 (11) , 4370-4378
Decoupling the Functional Roles of Cationic and Hydrophobic Groups in the Antimicrobial and Hemolytic Activities of Methacrylate Random Copolymers
In this study, we report the antimicrobial and hemolytic activities of ternary statistical methacrylate copolymers consisting of cationic ammonium (amino-ethyl methacrylate: AEMA), hydrophobic alkyl (ethyl methacrylate: EMA), and neutral hydroxyl (hydroxyethyl methacrylate: HEMA) side chain monomers. The cationic and hydrophobic functionalities of copolymers mimic the cationic amphiphilicity of naturally occurring antimicrobial peptides (AMPs). The HEMA monomer units were used to separately modulate the compositions of cationic and hydrophobic monomers, and we investigated the effect of each component on the antimicrobial and hemolytic activities of copolymers. Our data indicated that increasing the number of cationic groups of the copolymers to be more than 30 mol % did not increase their antimicrobial activity against Escherichia coli. The number of cationic side chains in a polymer chain at this threshold is 5.5–7.7, which is comparable to those of natural antimicrobial peptides such as maginin (+6). The MIC values of copolymers with >30 mol % of AEMA depend on only the mol % of EMA, indicating that the hydrophobic interactions of the copolymers with E. coli cell membranes determine the antimicrobial activity of copolymers. These results suggest that the roles of cationic and hydrophobic groups can be controlled independently by design in the ternary copolymers studied here.
- 27 January 2018
- Published by American Chemical Society (ACS) in Langmuir
- Vol. 34 (5) , 2057-2062
Monitoring Antimicrobial Mechanisms of Surface-Immobilized Peptides in Situ
Antimicrobial peptides (AMPs) in free solution can kill bacteria by disrupting bacterial cell membranes. Their modes of action have been extensively studied, and various models ranging from pore formation to carpet-like mechanisms were proposed. Surface-immobilized AMPs have been used as coatings to kill bacteria and as sensors to capture bacteria, but the interaction mechanisms of surface-immobilized AMPs and bacteria are not fully understood. In this research, an analytical platform, sum frequency generation (SFG) microscope, which is composed of an SFG vibrational spectrometer and a fluorescence microscope, was used to probe molecular interactions between surface-immobilized AMPs and bacteria in situ in real time at the solid/liquid interface. SFG probed the molecular structure of surface-immobilized AMPs while interacting with bacteria, and fluorescence images of dead bacteria were monitored as a function of time during the peptide–bacteria interaction. It was believed that upon bacteria contact, the surface-immobilized peptides changed their orientation and killed bacteria. This research demonstrated that the SFG microscope platform can examine the structure and function (bacterial killing) at the same time in the same sample environment, providing in-depth understanding on the structure–activity relationships of surface-immobilized AMPs.
- 27 January 2018
- Published by American Chemical Society (ACS) in Langmuir
- Vol. 34 (5) , 2057-2062
Monitoring Antimicrobial Mechanisms of Surface-Immobilized Peptides in Situ
Antimicrobial peptides (AMPs) in free solution can kill bacteria by disrupting bacterial cell membranes. Their modes of action have been extensively studied, and various models ranging from pore formation to carpet-like mechanisms were proposed. Surface-immobilized AMPs have been used as coatings to kill bacteria and as sensors to capture bacteria, but the interaction mechanisms of surface-immobilized AMPs and bacteria are not fully understood. In this research, an analytical platform, sum frequency generation (SFG) microscope, which is composed of an SFG vibrational spectrometer and a fluorescence microscope, was used to probe molecular interactions between surface-immobilized AMPs and bacteria in situ in real time at the solid/liquid interface. SFG probed the molecular structure of surface-immobilized AMPs while interacting with bacteria, and fluorescence images of dead bacteria were monitored as a function of time during the peptide–bacteria interaction. It was believed that upon bacteria contact, the surface-immobilized peptides changed their orientation and killed bacteria. This research demonstrated that the SFG microscope platform can examine the structure and function (bacterial killing) at the same time in the same sample environment, providing in-depth understanding on the structure–activity relationships of surface-immobilized AMPs.
- 24 July 2017
- Published by American Chemical Society (ACS) in Journal of Chemical Education
- Vol. 94 (11) , 1639-1646
Augmenting Primary and Secondary Education with Polymer Science and Engineering
- 24 July 2017
- Published by American Chemical Society (ACS) in Journal of Chemical Education
- Vol. 94 (11) , 1639-1646
Augmenting Primary and Secondary Education with Polymer Science and Engineering
- 30 June 2017
- Published by Wiley
- p. 243-272
Design and Synthesis of Amphiphilic Vinyl Copolymers with Antimicrobial Activity
- 30 June 2017
- Published by Wiley
- p. 243-272
Design and Synthesis of Amphiphilic Vinyl Copolymers with Antimicrobial Activity
- 8 April 2016
- Published by Association for Materials Protection and Performance (AMPP) in Corrosion
- Vol. 72 (9) , 1095-1106
Corrosion of Cu-5Zn-5Al-1Sn (89% Cu, 5% Zn, 5% Al, 1% Sn) Compared to Copper in Synthetic Perspiration During Cyclic Wetting and Drying: The Fate of Copper
Cu-5Zn-5Al-1Sn (89% Cu, 5% Zn, 5% Al, 1% Sn; wt%) and UNS C11000 copper (Cu) were compared with respect to corrosion rate, film formation, and Cu release. Electrochemical, surface characterization, and solution analysis methods were utilized to track the fate of copper during corrosion of freshly ground alloys exposed to cyclic wetting and drying in a synthetic perspiration droplet. Corrosion behavior was a function of both alloy composition and environment, where cyclic wetting and drying resulted in more severe corrosion behavior compared to full immersion in the same perspiration solution. Throughout the corrosion process, significant concentrations of copper ions were released from both alloys. However, concentration increases were limited by solubility and precipitation reaction but still suggested antimicrobial efficacy.
- 8 April 2016
- Published by Association for Materials Protection and Performance (AMPP) in Corrosion
- Vol. 72 (9) , 1095-1106
Corrosion of Cu-5Zn-5Al-1Sn (89% Cu, 5% Zn, 5% Al, 1% Sn) Compared to Copper in Synthetic Perspiration During Cyclic Wetting and Drying: The Fate of Copper
Cu-5Zn-5Al-1Sn (89% Cu, 5% Zn, 5% Al, 1% Sn; wt%) and UNS C11000 copper (Cu) were compared with respect to corrosion rate, film formation, and Cu release. Electrochemical, surface characterization, and solution analysis methods were utilized to track the fate of copper during corrosion of freshly ground alloys exposed to cyclic wetting and drying in a synthetic perspiration droplet. Corrosion behavior was a function of both alloy composition and environment, where cyclic wetting and drying resulted in more severe corrosion behavior compared to full immersion in the same perspiration solution. Throughout the corrosion process, significant concentrations of copper ions were released from both alloys. However, concentration increases were limited by solubility and precipitation reaction but still suggested antimicrobial efficacy.
- 2 October 2015
- Published by Association for Materials Protection and Performance (AMPP) in Corrosion
- Vol. 72 (1) , 51-65
The Fate of Copper During Corrosion of Cu-5Zn-5Al-1Sn (89% Cu, 5% Zn, 5% Al, 1% Sn) Compared to Copper in Synthetic Perspiration Solution
Cu-5Zn-5Al-1Sn (89% Cu, 5% Zn, 5% Al, 1% Sn) and UNS C11000 copper (Cu) were compared with respect to corrosion rate, film formation, and Cu release in two surface conditions pertinent to the use of antimicrobial functional materials. Electrochemical, surface characterization, and solution analysis methods were utilized to track the fate of copper during corrosion in synthetic perspiration solution in a freshly ground condition and after 30-d lab air passivation. Corrosion behavior was a function of both alloy composition and surface condition with slightly lower corrosion rates on Cu-5Zn-5Al-1Sn compared to Cu. Throughout the corrosion process, the majority of Cu was observed to undergo dissolution into the synthetic perspiration solution as copper cations for both materials, at concentrations that would suggest favorable antimicrobial functionality for both Cu-5Zn-5Al-1Sn and Cu, regardless of surface condition. In contrast, oxide films were thinner on Cu-5Zn-5Al-1Sn under all conditions. Hence, the combination of a slightly lower corrosion rate and a thinner oxide resulted in a similar Cu release rate for the two materials in synthetic perspiration.
- 2 October 2015
- Published by Association for Materials Protection and Performance (AMPP) in Corrosion
- Vol. 72 (1) , 51-65
The Fate of Copper During Corrosion of Cu-5Zn-5Al-1Sn (89% Cu, 5% Zn, 5% Al, 1% Sn) Compared to Copper in Synthetic Perspiration Solution
Cu-5Zn-5Al-1Sn (89% Cu, 5% Zn, 5% Al, 1% Sn) and UNS C11000 copper (Cu) were compared with respect to corrosion rate, film formation, and Cu release in two surface conditions pertinent to the use of antimicrobial functional materials. Electrochemical, surface characterization, and solution analysis methods were utilized to track the fate of copper during corrosion in synthetic perspiration solution in a freshly ground condition and after 30-d lab air passivation. Corrosion behavior was a function of both alloy composition and surface condition with slightly lower corrosion rates on Cu-5Zn-5Al-1Sn compared to Cu. Throughout the corrosion process, the majority of Cu was observed to undergo dissolution into the synthetic perspiration solution as copper cations for both materials, at concentrations that would suggest favorable antimicrobial functionality for both Cu-5Zn-5Al-1Sn and Cu, regardless of surface condition. In contrast, oxide films were thinner on Cu-5Zn-5Al-1Sn under all conditions. Hence, the combination of a slightly lower corrosion rate and a thinner oxide resulted in a similar Cu release rate for the two materials in synthetic perspiration.
- 1 July 2015
- Published by Elsevier in Electrochimica Acta
- Vol. 169, 351-366
Tarnishing and Cu Ion release in Selected Copper-Base Alloys: Implications towards Antimicrobial Functionality
- 1 July 2015
- Published by Elsevier in Electrochimica Acta
- Vol. 169, 351-366
Tarnishing and Cu Ion release in Selected Copper-Base Alloys: Implications towards Antimicrobial Functionality
- 20 October 2014
- Published by Wiley in Journal of Applied Polymer Science
- Vol. 132 (9)
Synthesis and surface characterization of copoly(imide alkyl ether)s containing pendant fluoroalkyl groups
A series of copoly(imide alkyl ether)s were synthesized to explore surface migration of fluorinated alkyl ether blocks (AEFO)s. Mechanical and surface properties of solution cast, thermally imidized films were determined. Incorporation of the AEFO oligomers at loading levels up to 5 wt % resulted in a slight decrease (usually less than 10%) in tensile modulus. Surface migration of the AEFOs raised the advancing water contact angle from approximately 80° to above 95° for the copolymer systems. The composition at which addition of more AEFO further increased water contact angle values was related to the number of fluorine atoms in the perfluorinated side chains. Surface excess concentration of the AEFO at different loading levels was calculated from X‐ray photoelectron spectroscopy results. At higher AEFO loading levels, the surface excess concentration was relatively constant suggesting formation of stable structures within the bulk similar to micelle formation in surfactant solutions. Based on these results, it was determined that surface saturation occurred with the fluorinated AEFO species at loading levels as low as 1 wt % engendering changes in surface properties while retaining the bulk imide properties. © 2014 Wiley Periodicals, Inc. J. Appl. Polym. Sci.2015,132, 41538.
- 20 October 2014
- Published by Wiley in Journal of Applied Polymer Science
- Vol. 132 (9)
Synthesis and surface characterization of copoly(imide alkyl ether)s containing pendant fluoroalkyl groups
A series of copoly(imide alkyl ether)s were synthesized to explore surface migration of fluorinated alkyl ether blocks (AEFO)s. Mechanical and surface properties of solution cast, thermally imidized films were determined. Incorporation of the AEFO oligomers at loading levels up to 5 wt % resulted in a slight decrease (usually less than 10%) in tensile modulus. Surface migration of the AEFOs raised the advancing water contact angle from approximately 80° to above 95° for the copolymer systems. The composition at which addition of more AEFO further increased water contact angle values was related to the number of fluorine atoms in the perfluorinated side chains. Surface excess concentration of the AEFO at different loading levels was calculated from X‐ray photoelectron spectroscopy results. At higher AEFO loading levels, the surface excess concentration was relatively constant suggesting formation of stable structures within the bulk similar to micelle formation in surfactant solutions. Based on these results, it was determined that surface saturation occurred with the fluorinated AEFO species at loading levels as low as 1 wt % engendering changes in surface properties while retaining the bulk imide properties. © 2014 Wiley Periodicals, Inc. J. Appl. Polym. Sci.2015,132, 41538.