Gabriella Azzopardi
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Gabriella Azzopardi has a total of 24 co-authors. Here are the top co-authors by number of shared publications:
- Andre Henriques
European Organization for Nuclear Research
4 shared publications - James Devine
CERN
4 shared publications - Marco Andreini
European Organization for Nuclear Research
4 shared publications - Nicola Tarocco
European Organization for Nuclear Research
4 shared publications - Nicolas Mounet
European Organization for Nuclear Research
4 shared publications - Julian W. Tang
Department of Clinical Microbiology University Hospitals of Leicester NHS Trust Leicester UK
3 shared publications
Latest Publications
- Open Access
- 26 February 2025
- Published by The Royal Society in Journal of The Royal Society Interface
- Vol. 22 (223) , 20240740
An integrated airborne transmission risk assessment model for respiratory viruses: short- and long-range contributions
This study presents an advanced airborne transmission risk assessment model that integrates both short- and long-range routes in the spread of respiratory viruses, building upon the CERN Airborne Model for Indoor Risk Assessment (CAiMIRA) and aligned with the new World Health Organization (WHO) terminology. Thanks to a two-stage exhaled jet approach, the model accurately simulates short-range exposures, thereby improving infection risk predictions across diverse indoor settings. Key findings reveal that in patient wards, the short-range viral dose is 10-fold higher than the long-range component, highlighting the critical role of close proximity interactions. Implementation of FFP2 respirators resulted in a remarkable 13-fold reduction in viral dose, underscoring the effectiveness of personal protective equipment (PPE). Additionally, the model demonstrated that an 8 h exposure in a poorly ventilated office can equate to the risk of a 15 min face-to-face, mask-less interaction, emphasizing the importance of physical distancing and source control. We also found in high-risk or low-occupancy settings, that secondary transmission is driven more by overall epidemic trends than by the presence of individual superspreaders. Monte Carlo simulations across various scenarios, including classrooms and offices, validate the model’s robustness in optimizing infection prevention strategies. These findings support targeted interventions for short- and long-range exposure to reduce airborne transmission.
- 26 February 2025
- Published by The Royal Society in Journal of The Royal Society Interface
- Vol. 22 (223) , 20240740
Open AccessAn integrated airborne transmission risk assessment model for respiratory viruses: short- and long-range contributions
This study presents an advanced airborne transmission risk assessment model that integrates both short- and long-range routes in the spread of respiratory viruses, building upon the CERN Airborne Model for Indoor Risk Assessment (CAiMIRA) and aligned with the new World Health Organization (WHO) terminology. Thanks to a two-stage exhaled jet approach, the model accurately simulates short-range exposures, thereby improving infection risk predictions across diverse indoor settings. Key findings reveal that in patient wards, the short-range viral dose is 10-fold higher than the long-range component, highlighting the critical role of close proximity interactions. Implementation of FFP2 respirators resulted in a remarkable 13-fold reduction in viral dose, underscoring the effectiveness of personal protective equipment (PPE). Additionally, the model demonstrated that an 8 h exposure in a poorly ventilated office can equate to the risk of a 15 min face-to-face, mask-less interaction, emphasizing the importance of physical distancing and source control. We also found in high-risk or low-occupancy settings, that secondary transmission is driven more by overall epidemic trends than by the presence of individual superspreaders. Monte Carlo simulations across various scenarios, including classrooms and offices, validate the model’s robustness in optimizing infection prevention strategies. These findings support targeted interventions for short- and long-range exposure to reduce airborne transmission.
- Open Access
- 11 February 2022
- Published by The Royal Society in Interface Focus
- Vol. 12 (2) , 20210076
Modelling airborne transmission of SARS-CoV-2 using CARA: risk assessment for enclosed spaces
The COVID-19 pandemic has highlighted the need for a proper risk assessment of respiratory pathogens in indoor settings. This paper documents the COVID Airborne Risk Assessment methodology, to assess the potential exposure of airborne SARS-CoV-2 viruses, with an emphasis on virological and immunological factors in the quantification of the risk. The model results from a multidisciplinary approach linking physical, mechanical and biological domains, enabling decision makers or facility managers to assess their indoor setting. The model was benchmarked against clinical data, as well as two real-life outbreaks, showing good agreement. A probability of infection is computed in several everyday-life settings and with various mitigation measures. The importance of super-emitters in airborne transmission is confirmed: 20% of infected hosts can emit approximately two orders of magnitude more viral-containing particles. The use of masks provides a fivefold reduction in viral emissions. Natural ventilation strategies are very effective to decrease the concentration of virions, although periodic venting strategies are not ideal in certain settings. Although vaccination is an effective measure against hospitalization, their effectiveness against transmission is not optimal, hence non-pharmaceutical interventions (ventilation, masks) should be actively supported. We also propose a critical threshold to define an acceptable risk level.
- 11 February 2022
- Published by The Royal Society in Interface Focus
- Vol. 12 (2) , 20210076
Open AccessModelling airborne transmission of SARS-CoV-2 using CARA: risk assessment for enclosed spaces
The COVID-19 pandemic has highlighted the need for a proper risk assessment of respiratory pathogens in indoor settings. This paper documents the COVID Airborne Risk Assessment methodology, to assess the potential exposure of airborne SARS-CoV-2 viruses, with an emphasis on virological and immunological factors in the quantification of the risk. The model results from a multidisciplinary approach linking physical, mechanical and biological domains, enabling decision makers or facility managers to assess their indoor setting. The model was benchmarked against clinical data, as well as two real-life outbreaks, showing good agreement. A probability of infection is computed in several everyday-life settings and with various mitigation measures. The importance of super-emitters in airborne transmission is confirmed: 20% of infected hosts can emit approximately two orders of magnitude more viral-containing particles. The use of masks provides a fivefold reduction in viral emissions. Natural ventilation strategies are very effective to decrease the concentration of virions, although periodic venting strategies are not ideal in certain settings. Although vaccination is an effective measure against hospitalization, their effectiveness against transmission is not optimal, hence non-pharmaceutical interventions (ventilation, masks) should be actively supported. We also propose a critical threshold to define an acceptable risk level.
- Open Access
Modelling airborne transmission of SARS-CoV-2 using CARA: Risk assessment for enclosed spaces
The global crisis triggered by the COVID-19 pandemic has highlighted the need for a proper risk assessment of respiratory pathogens in indoor settings. This paper documents the COVID Airborne Risk Assessment (CARA) methodology, to assess the potential exposure of airborne SARS-CoV-2 viruses, with an emphasis on the effect of certain virological and immunological factors in the quantification of the risk. The proposed model is the result of a multidisciplinary approach linking physical, mechanical and biological domains, benchmarked with clinical and experimental data, enabling decision makers or facility managers to perform risk assessments against airborne transmission. The model was tested against two benchmark outbreaks, showing good agreement. The tool was also applied to several everyday-life settings, in particular for the cases of a shared office, classroom and ski cabin. We found that 20% of infected hosts can emit approximately 2 orders of magnitude more viral-containing particles, suggesting the importance of super-emitters in airborne transmission. The use of surgical-type masks provides a 5-fold reduction in viral emissions. Natural ventilation through the opening of windows at all times are effective strategies to decrease the concentration of virions and slightly opening a window in the winter has approximately the same effect as a full window opening during the summer. Although vaccination is an effective protection measure, non-pharmaceutical interventions, which significantly reduce the viral density in the air (ventilation, masks), should be actively supported and included early in the risk assessment process. We propose a critical threshold value approach which could be used to define an acceptable risk level in a given indoor setting.
Open AccessModelling airborne transmission of SARS-CoV-2 using CARA: Risk assessment for enclosed spaces
The global crisis triggered by the COVID-19 pandemic has highlighted the need for a proper risk assessment of respiratory pathogens in indoor settings. This paper documents the COVID Airborne Risk Assessment (CARA) methodology, to assess the potential exposure of airborne SARS-CoV-2 viruses, with an emphasis on the effect of certain virological and immunological factors in the quantification of the risk. The proposed model is the result of a multidisciplinary approach linking physical, mechanical and biological domains, benchmarked with clinical and experimental data, enabling decision makers or facility managers to perform risk assessments against airborne transmission. The model was tested against two benchmark outbreaks, showing good agreement. The tool was also applied to several everyday-life settings, in particular for the cases of a shared office, classroom and ski cabin. We found that 20% of infected hosts can emit approximately 2 orders of magnitude more viral-containing particles, suggesting the importance of super-emitters in airborne transmission. The use of surgical-type masks provides a 5-fold reduction in viral emissions. Natural ventilation through the opening of windows at all times are effective strategies to decrease the concentration of virions and slightly opening a window in the winter has approximately the same effect as a full window opening during the summer. Although vaccination is an effective protection measure, non-pharmaceutical interventions, which significantly reduce the viral density in the air (ventilation, masks), should be actively supported and included early in the risk assessment process. We propose a critical threshold value approach which could be used to define an acceptable risk level in a given indoor setting.
- Open Access
SARS-CoV-2 aerosol transmission in schools: the effectiveness of different interventions
A bstract: Background: Indoor aerosol transmission of SARS-CoV-2 has been widely recognized, especially in schools where children remain in closed indoor spaces and largely unvaccinated. Measures such as strategic natural ventilation and high efficiency particulate air (HEPA) filtration remain poorly implemented and mask mandates are often progressively lifted as vaccination rollout is enhanced. Methods: We adapted a previously developed aerosol transmission model to study the effect of interventions (natural ventilation, face masks, HEPA filtration, and their combinations) on the concentration of virus particles in a classroom of 160 m 3 containing one infectious individual. The cumulative dose of viruses absorbed by exposed occupants was calculated. Results: The most effective single intervention was natural ventilation through the full opening of six windows all day during the winter (14-fold decrease in cumulative dose), followed by the universal use of surgical face masks (8-fold decrease). In the spring/summer, natural ventilation was only effective (≥ 2-fold decrease) when windows were fully open all day. In the winter, partly opening two windows all day or fully opening six windows at the end of each class was effective as well (≥ 2-fold decrease). Opening windows during yard and lunch breaks only had minimal effect (≤ 1.2-fold decrease). One HEPA filter was as effective as two windows partly open all day during the winter (2.5-fold decrease) while two filters were more effective (4-fold decrease). Combined interventions (i.e., natural ventilation, masks, and HEPA filtration) were the most effective (≥ 30-fold decrease). Combined interventions remained highly effective in the presence of a super-spreader. Conclusions: Natural ventilation, face masks, and HEPA filtration are effective interventions to reduce SARS-CoV-2 aerosol transmission. These measures should be combined and complemented by additional interventions (e.g., physical distancing, hygiene, testing, contact tracing, and vaccination) to maximize benefit.
Open AccessSARS-CoV-2 aerosol transmission in schools: the effectiveness of different interventions
A bstract: Background: Indoor aerosol transmission of SARS-CoV-2 has been widely recognized, especially in schools where children remain in closed indoor spaces and largely unvaccinated. Measures such as strategic natural ventilation and high efficiency particulate air (HEPA) filtration remain poorly implemented and mask mandates are often progressively lifted as vaccination rollout is enhanced. Methods: We adapted a previously developed aerosol transmission model to study the effect of interventions (natural ventilation, face masks, HEPA filtration, and their combinations) on the concentration of virus particles in a classroom of 160 m 3 containing one infectious individual. The cumulative dose of viruses absorbed by exposed occupants was calculated. Results: The most effective single intervention was natural ventilation through the full opening of six windows all day during the winter (14-fold decrease in cumulative dose), followed by the universal use of surgical face masks (8-fold decrease). In the spring/summer, natural ventilation was only effective (≥ 2-fold decrease) when windows were fully open all day. In the winter, partly opening two windows all day or fully opening six windows at the end of each class was effective as well (≥ 2-fold decrease). Opening windows during yard and lunch breaks only had minimal effect (≤ 1.2-fold decrease). One HEPA filter was as effective as two windows partly open all day during the winter (2.5-fold decrease) while two filters were more effective (4-fold decrease). Combined interventions (i.e., natural ventilation, masks, and HEPA filtration) were the most effective (≥ 30-fold decrease). Combined interventions remained highly effective in the presence of a super-spreader. Conclusions: Natural ventilation, face masks, and HEPA filtration are effective interventions to reduce SARS-CoV-2 aerosol transmission. These measures should be combined and complemented by additional interventions (e.g., physical distancing, hygiene, testing, contact tracing, and vaccination) to maximize benefit.
- Open Access
- 30 September 2019
- Published by American Physical Society (APS) in Physical Review Accelerators and Beams
- Vol. 22 (9) , 093001
Operational results on the fully automatic LHC collimator alignment
The Large Hadron Collider has a complex collimation system installed to protect its sensitive equipment from normal and abnormal beam losses. The collimators are set around the beam following a multistage transverse setting hierarchy. The insertion position of each collimator is established using beam-based alignment techniques to determine the local beam position and rms beam size at each collimator. During previous years, collimator alignments were performed semiautomatically, with collimation experts present to oversee and control the alignment. During run II, a new fully automatic alignment tool was developed and used for collimator alignments throughout 2018. This paper discusses the improvements on the alignment software to automate it using machine learning, whilst focusing on the operational results obtained when testing the new software in the LHC. The alignment tests were conducted with both proton and ion beams, and angular alignments were performed with proton beams. This upgraded software successfully decreased the alignment time by a factor of 3 and made the results more reproducible, which is particularly important when performing angular alignments.
- 30 September 2019
- Published by American Physical Society (APS) in Physical Review Accelerators and Beams
- Vol. 22 (9) , 093001
Open AccessOperational results on the fully automatic LHC collimator alignment
The Large Hadron Collider has a complex collimation system installed to protect its sensitive equipment from normal and abnormal beam losses. The collimators are set around the beam following a multistage transverse setting hierarchy. The insertion position of each collimator is established using beam-based alignment techniques to determine the local beam position and rms beam size at each collimator. During previous years, collimator alignments were performed semiautomatically, with collimation experts present to oversee and control the alignment. During run II, a new fully automatic alignment tool was developed and used for collimator alignments throughout 2018. This paper discusses the improvements on the alignment software to automate it using machine learning, whilst focusing on the operational results obtained when testing the new software in the LHC. The alignment tests were conducted with both proton and ion beams, and angular alignments were performed with proton beams. This upgraded software successfully decreased the alignment time by a factor of 3 and made the results more reproducible, which is particularly important when performing angular alignments.
- Open Access
- 8 August 2019
- Published by American Physical Society (APS) in Physical Review Accelerators and Beams
- Vol. 22 (8) , 083002
Data-driven cross-talk modeling of beam losses in LHC collimators
The Large Hadron Collider at CERN is equipped with a collimation system to intercept potentially dangerous beam halo particles before they damage its sensitive equipment. The collimator settings are determined following a beam-based alignment procedure, in which the collimator jaws are moved towards the beam until losses appear in the beam loss monitors. When the collimator reaches the beam envelope, beam losses propagate mainly in the direction of the beam and are, therefore, also observed by other nearby beam loss monitors. This phenomenon is known as cross talk. Due to this, collimators are aligned sequentially to be able to identify which losses are generated by which collimator, such that any cross talk across beam loss monitors positioned close to each other is avoided. This paper seeks to quantify the levels of cross-talk observed by beam loss monitors when multiple collimators are moving, to be able to determine the actual beam loss signals generated by their corresponding collimators. The results obtained successfully predicted the amount of cross-talk observed for each of the cases tested in this study. This was then extended to predict loss map case studies and the proton impacts at each collimator by comparing them to simulations.
- 8 August 2019
- Published by American Physical Society (APS) in Physical Review Accelerators and Beams
- Vol. 22 (8) , 083002
Open AccessData-driven cross-talk modeling of beam losses in LHC collimators
The Large Hadron Collider at CERN is equipped with a collimation system to intercept potentially dangerous beam halo particles before they damage its sensitive equipment. The collimator settings are determined following a beam-based alignment procedure, in which the collimator jaws are moved towards the beam until losses appear in the beam loss monitors. When the collimator reaches the beam envelope, beam losses propagate mainly in the direction of the beam and are, therefore, also observed by other nearby beam loss monitors. This phenomenon is known as cross talk. Due to this, collimators are aligned sequentially to be able to identify which losses are generated by which collimator, such that any cross talk across beam loss monitors positioned close to each other is avoided. This paper seeks to quantify the levels of cross-talk observed by beam loss monitors when multiple collimators are moving, to be able to determine the actual beam loss signals generated by their corresponding collimators. The results obtained successfully predicted the amount of cross-talk observed for each of the cases tested in this study. This was then extended to predict loss map case studies and the proton impacts at each collimator by comparing them to simulations.