LLLauri Lehmonen

Lauri Lehmonen

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Lauri Lehmonen has a total of 51 co-authors. Here are the top co-authors by number of shared publications:

  • Johanna Kuusisto

    Institute of Clinical Medicine, Internal Medicine and Kuopio University Hospital, Kuopio, Finland

    3 shared publications
  • Kirsi Lauerma

    HUS Medical Imaging Center, Radiology, University of Helsinki and Helsinki University Hospital, Helsinki, Finland

    3 shared publications
  • Mika Tarkiainen

    Department of Clinical Radiology, Kuopio University Hospital, Kuopio, Finland

    3 shared publications
  • Mikko Jalanko

    Department of Cardiology, Heart and Lung Center, Helsinki University Hospital and University of Helsinki, Helsinki, Finland

    3 shared publications
  • Sauli Savolainen

    HUS Medical Imaging Center, Radiology, University of Helsinki and Helsinki University Hospital, Helsinki, Finland

    3 shared publications
  • Touko Kaasalainen

    HUS Diagnostic Center, Radiology, Helsinki University and Helsinki University Hospital, Haartmaninkatu 4, 00290 Helsinki, Finland

    3 shared publications

Latest Publications

  • Open Access

    Cardiac Involvement in Patients with MELAS-Related mtDNA 3243A>G Variant

    by Aino-Maija Vuorinen, Lauri Lehmonen, Mari Auranen, Sini Weckström, Sari Kivistö, Miia Holmström, Tiina Heliö

    Mitochondrial myopathy, encephalopathy, lactic acidosis, and stroke-like episodes (MELAS) syndrome is a rare disease with variable clinical manifestations. MELAS is most often caused by the human mitochondrial DNA (mtDNA) m.3243A>G variant. We describe cardiac magnetic resonance (CMR) imaging findings and clinical features of 22 subjects with the m.3243A>G mutation and endeavored to discover the role of CMR in MELAS cardiomyopathy diagnostics. The clinical symptoms, ECG findings, and laboratory tests were retrospectively collected from the electronic medical record. Ten subjects (46%) had cardiac symptoms, and eighteen subjects (82%) had some clinical symptoms or signs of MELAS. Seventeen subjects (77%) showed cardiac findings compatible with MELAS. An ECG showed a short PR interval in six subjects (27%). Two patients had a first-degree atrioventricular block. Repolarization changes in the ECG were observed in thirteen subjects (59%), whereas left ventricular hypertrophy voltage criteria were only observed in one subject. Patients with ECG abnormalities had a strong link between proBNP value and cardiac tissue composition (T1 relaxation, p < 0.02) and showed decreased CMR-based strain (p < 0.025). The CMR findings are heterogeneous in subjects with m.3243A>G. Cardiac MELAS may include left ventricular hypertrophy, which mimics sarcomericcardiomyopathy but maypredispose individuals to severe heart failure episodes triggered by acute critical situations. CMR may be used to clarify ECG findings. This study indicates that the genetic testing of MELAS should be considered in new cases of HCM or sudden heart failure phenotypes of unknown etiology.


  • Open Access

    MRI-derived cardiac washout is slowed in the left ventricle and associated with left ventricular non-compaction in young patients with cryptogenic ischemic stroke

    by Lauri Lehmonen, Jukka Putaala, Pauli Pöyhönen, Jouni Kuusisto, Jani Pirinen, Juha Sinisalo, Vesa Järvinen

    To elucidate underlying disease mechanisms, we compared transition of gadolinium-based contrast agent bolus in cardiac chambers in magnetic resonance imaging between young patents with cryptogenic ischemic stroke and stroke-free controls. We included 30 patients aged 18–50 years with cryptogenic ischemic stroke from the prospective Searching for Explanations for Cryptogenic Stroke in the Young: Revealing the Etiology, Triggers and Outcome (NCT01934725) study and 30 age- and gender-matched stroke-free controls. Dynamic contrast-enhanced T1-weighted first-pass perfusion images were acquired at 1.5 T and analyzed for transit time variables, area under curves, relative blood flow, and maximum and minimum enhancement rates in left atrial appendage, left atrium, and left ventricle. These data were compared with previously published left ventricular non-compaction data of the same study population. Arrival time of contrast agent bolus in superior vena cava was similar in patients and controls (6.7[2.0] vs. 7.1[2.5] cardiac cycles, P = 0.626). Arrival and peak times showed comparable characteristics in patients and controls (P > 0.535). The minimum enhancement rate of the left ventricle was lower in patients than in controls (− 28 ± 11 vs. − 36 ± 13 1/(cardiac cycle), P = 0.012). Area under curves, relative blood flow, and other enhancement rates showed no significant differences between patients and controls (P > 0.107). Relative blood flow of cardiac chambers correlated with non-compacted left ventricular volume ratio (P < 0.011). Our results indicate slower washout of contrast agent and blood flow stagnation in the left ventricle of young patients with cryptogenic ischemic stroke. The washout was associated with left ventricular non-compaction, suggesting conditions favoring formation of intraventricular thrombosis.


  • Orientation of the Atrial Septum to the Inferior Vena Cava May Contribute to the Persistent Patency of the Foramen Ovale

    by Pauli Pöyhönen, Jouni Kuusisto, Jani Pirinen, Heli Räty, Lauri Lehmonen, Riitta Paakkanen, Nicolas Martinez-Majander, Sahrai Saeed, Eva Gerdts, Jukka Putaala, et al.

    Purpose: There is growing evidence that paradoxical embolism through patent foramen ovale (PFO) is a cause for cryptogenic stroke. However, it is still unclear why the foramen ovale fails to close after birth. We studied whether the 3D relations between the atrial septum (AS) and the inferior vena cava (IVC) are associated with PFO. Methods: We recruited 30 patients (18–49 years) with a first-ever cryptogenic stroke and 30 age- and sex-matched stroke-free controls. Using cardiac magnetic resonance, an approach to evaluate the 3D relations between the AS and the IVC was developed. The presence of interatrial right-to-left shunt was evaluated with transesophageal echocardiography (TEE) in patients and transcranial Doppler in controls. Results: Of 30 patients, 29 underwent successful TEE, of which 12 (41%) had a shunt. Patients with a shunt had a greater mean 3D angle (γ) between the atrial septal plane and the vector from the orifice of the IVC to the middle of the AS compared with patients without a shunt (45 ± 9° vs. 36 ± 8°, p = 0.017). Of 30 controls, 12 (40%) had a shunt and a greater mean γ compared with controls without a shunt (47 ± 8° vs. 37 ± 10°, p = 0.007). In a pooled analysis, 24 (41%) of 59 subjects with a shunt had a mean γ of 46 ± 9° compared with subjects without a shunt of 37 ± 9° (p < 0.001). Conclusions: More perpendicular orientation of the atrial septal plane to the orifice of the IVC is associated with PFO, possibly by directing the IVC flow to PFO.


  • Open Access

    Magnetic resonance imaging derived cardiac first pass perfusion in cryptogenic ischemic stroke in the young

    by L Lehmonen, J Pirinen, J Putaala, N Martinez-Majander, J Kuusisto, J Sinisalo, V Jarvinen

    Type of funding sources: None. Up to 50% of ischemic strokes in adults aged between 18 and 50 are cryptogenic by nature. Heart has been a hypothesised source. Purpose: Purpose of the study was to investigate the wash in and wash out of gadolinium based contrast agent in the left atrial appendage, and cardiac chambers in first pass cardiac magnetic resonance imaging. The study comprised 30 patients with first-ever cryptogenic ischemic stroke and 30 age and gender matched stroke-free controls included in the prospective multicenter study Searching for Explanations for Cryptogenic Stroke in the Young: Revealing the Etiology, Triggers and Outcome (SECRETO; NCT01934725). Cardiac magnetic resonance imaging was performed on all participants with a 1.5T magnetic resonance system. Dynamic contrast enhanced T1 weighted first pass perfusion images were acquired in the superior vena cava, the left atrial appendage (Fig. 1), and the left ventricle. The images were analyzed for time-intensity curves (Fig. 2), and results were normalised to individual heart rate. Arrival times, peak times, areas under the curves, relative blood flows (defined as area under the curve/full width at half maximum), and maximum and minimum rates of bolus wash in / wash out were calculated. The wash in of the contrast agent bolus was similar in patients and controls. Arrival times and peak timings showed similar characteristics in patients and controls in the left atrial appendage (arrival time: 12.4 [2.3] vs. 13.5 [3.6] cardiac cycles, p = 0.657; peak time: 19.6 [5.1] vs. 19.8 [6.9] cardiac cycles, p = 0.929) and the left atrium (arrival time: 12.2 [2.8] vs. 13.0 [3.6] cardiac cycles, p = 0.535; peak time: 18.7 [5.5] vs. 18.1 [5.2] cardiac cycles, p = 0.790). Areas under under the curves and relative blood flows were similar in patients and controls. A significant difference between patients and controls was found in the wash out rate of gadolinium in the left ventricle (-28 [11] vs. -36 [13] 1/cardiac cycles, p = 0.012), indicating slightly slower wash out in the patients. Cryptogenic ischemic stroke in the young is not associated with prolonged blood flow in the left atrial appendage or left atrium. There were no significant differences in the first pass perfusion between subjects and healthy controls. However, there might be a slight tendency for stagnation of blood flow in the left ventricles of cryptogenic stroke patients. Abstract Figure. Fig 1. Example of first pass perfusion Abstract Figure. Fig 1. Example of first pass perfusion Abstract Figure. Fig 2. Time intensity curves Abstract Figure. Fig 2. Time intensity curves

  • Inter- and intra-scanner variations in four magnetic resonance imaging image quality parameters

    by Juha I. Peltonen, Teemu Mäkelä, Lauri Lehmonen, Alexey Sofiev, Eero Salli

    Purpose: In addition to less frequent and more comprehensive tests, quality assurance (QA) protocol for a magnetic resonance imaging (MRI) scanner may include cursory daily or weekly phantom checks to verify equipment constancy. With an automatic image analysis workflow, the daily QA images can be further used to study scanner baseline performance and both long- and short-term variations in image quality. With known baselines and variation profiles, automatic error detection can be employed. Approach: Four image quality parameters were followed for 17 MRI scanners over six months: signal-to-noise ratio (SNR), image intensity uniformity, ghosting artifact, and geometrical distortions. Baselines and normal variations were determined. An automatic detection of abnormal QA images was compared with image deviations visually detected by human observers. Results: There were significant inter-scanner differences in the QA parameters. In some cases, the results exceeded commonly accepted tolerances. Scanner field strengths, or a unit being stationary versus mobile, did not have a clear relationship with the QA results. Conclusions: The variations and baseline levels of image QA parameters can differ significantly between MRI scanners. Scanner specific error thresholds based on parameter means and standard deviations are a viable option for detecting abnormal QA images.


  • Open Access

    Rotation and torsion of the left ventricle with cardiovascular magnetic resonance tagging: comparison of two analysis methods

    by Lauri Lehmonen, Mikko Jalanko, Mika Tarkiainen, Touko Kaasalainen, Johanna Kuusisto, Kirsi Lauerma, Sauli Savolainen

    Background: Left ventricle rotation and torsion are fundamental components of myocardial function, and several software packages have been developed for analysis of these components. The purpose of this study was to compare the suitability of two software packages with different technical principles for analysis of rotation and torsion of the left ventricle during systole. Methods: A group of hypertrophic cardiomyopathy (HCM) patients (N = 14, age 43 ± 11 years), mutation carriers without hypertrophy (N = 10, age 34 ± 13 years), and healthy relatives (N = 12, age 43 ± 17 years) underwent a cardiovascular magnetic resonance examination, including spatial modulation of magnetization tagging sequences in basal and apical planes of the left ventricle. The tagging images were analyzed offline using a harmonic phase image analysis method with Gabor filtering and a non-rigid registration-based free-form deformation technique. Left-ventricle rotation and torsion scores were obtained from end-diastole to end-systole with both software. Results: Analysis was successful in all cases with both software applications. End-systolic torsion values between the study groups were not statistically different with either software. End-systolic apical rotation, end-systolic basal rotation, and end-systolic torsion were consistently higher when analyzed with non-rigid registration than with harmonic phase-based analysis (p < 0.0001). End-systolic rotation and torsion values had significant correlations between the two software (p < 0.0001), most significant in the apical plane. Conclusions: When comparing absolute values of rotation and torsion between different individuals, software-specific reference values are required. Harmonic phase flow with Gabor filtering and non-rigid registration-based methods can both be used reliably in the analysis of systolic rotation and torsion patterns of the left ventricle.


  • Open Access

    Rotation and torsion of the left ventricle with cardiovascular magnetic resonance tagging: comparison of two analysis methods

    by Lauri Lehmonen, Mikko Jalanko, Mika Tarkiainen, Touko Kaasalainen, Johanna Kuusisto, Kirsi Lauerma, Sauli Savolainen

    Background: Left ventricle rotation and torsion are fundamental components of myocardial function, and several software packages have been developed for analysis of these components. The purpose of this study was to compare the suitability of two software packages with different technical principles for analysis of rotation and torsion of the left ventricle during systole.Methods: A group of hypertrophic cardiomyopathy (HCM) patients (N = 14, age 43 ± 11 years), mutation carriers without hypertrophy (N = 10, age 34 ± 13 years), and healthy relatives (N = 12, age 43 ± 17 years) underwent a cardiovascular magnetic resonance examination, including spatial modulation of magnetization tagging sequences in basal and apical planes of the left ventricle. The tagging images were analyzed offline using a harmonic phase image analysis method with Gabor filtering and a non-rigid registration-based free-form deformation technique. Left-ventricle rotation and torsion scores were obtained from end-diastole to end-systole with both software. Results: Analysis was successful in all cases with both software applications. End-systolic torsion values between the study groups were not statistically different with either software. End-systolic apical rotation, end-systolic basal rotation, and end-systolic torsion were consistently higher when analyzed with non-rigid registration than with harmonic phase-based analysis (p < 0.0001). End-systolic rotation and torsion values had significant correlations between the two software (p < 0.0001), most significant in the apical plane.Conclusions: When comparing absolute values of rotation and torsion between different individuals, software-specific reference values are required. Harmonic phase flow with Gabor filtering and non-rigid registration-based methods can both be used reliably in the analysis of systolic rotation and torsion patterns of the left ventricle.

  • Open Access

    Rotation and torsion of the left ventricle with cardiovascular magnetic resonance tagging: comparison of two analysis software

    by Lauri Lehmonen, Mikko Jalanko, Mika Tarkiainen, Touko Kaasalainen, Johanna Kuusisto, Kirsi Lauerma, Sauli Savolainen

    Background Left ventricle rotation and torsion are fundamental components of myocardial function, several software have been developed for the analysis of these components. Purpose of the study was to compare the suitability of two such software with different technical principles in analyzing rotation and torsion of the left ventricle during systole. Methods A group of hypertrophic cardiomyopathy (HCM) patients (N = 14, age 43 ± 11 years), mutation carriers without hypertrophy (N = 10, age 34 ± 13 years) and healthy controls (N = 12, age 43 ± 17 years) underwent a cardiovascular magnetic resonance examination including spatial modulation of magnetization tagging sequences in basal and apical levels of the left ventricle. The tagging images were analyzed offline using a harmonic phase image analysis method with Gabor filtering, and with non-rigid registration based free-form deformation technique. Left-ventricle rotation and torsion scores were obtained from end-diastole to end-systole with both software.Results Analysis was successful in all cases with both software. End-systolic torsion values between the study groups were not statistically different, with either software. End-systolic apical rotation, end-systolic basal rotation, and end-systolic torsion were consistently higher in Segment compared to HPF (p < 0.0001). End-systolic rotation and torsion values had statistically significant correlations between the two software (p < 0.0001), most significant in the apical plane. Conclusions When comparing absolute values of rotation and torsion between different individuals, software specific reference values are required. Harmonic phase flow with Gabor filtering, and non-rigid registration-based analysis methods can both be used reliably in the analysis of systolic rotation and torsion patterns of the left ventricle.

  • Open Access

    Severe pulmonary regurgitation in adolescents with tetralogy of Fallot leads to increased longitudinal strain

    by Pekka Ylitalo, Lauri Lehmonen, Kirsi Lauerma, Miia Holmström, Olli Pitkänen-Argillander, Eero Jokinen

    Objectives: Postoperative patients with tetralogy of Fallot (TOF) are often compromised by chronic pulmonary regurgitation and chronic right ventricular volume load. We sought to determine whether pulmonary regurgitation (PR) would affect right and left ventricle (RV and LV) strain. Materials and methods: This cross-sectional analysis included 40 patients who had TOF with surgical repair, with an average follow-up period of 11.8 ± 3.0 years. Altogether, 44 healthy volunteers with similar age and gender distribution were recruited. A cardiovascular magnetic resonance imaging study with feature tracking analysis was performed on all patients and controls. Results: RV peak longitudinal strain was increased in TOF patients with PR > 30 ml/m2 when compared to those with PR < 30 ml/m2 (− 22.5% ± 2.7% vs − 19.7% ± 3.5%, p = 0.018) and controls (p = 0.007). PR volume correlated with peak RV longitudinal strain (R = − 0.37, p = 0.030) and peak RV longitudinal strain rate (systolic: R = 0.37, p = 0.03; diastolic: R = 0.39, p = 0.021). The peak RV circumferential strain, from base to apex, increased more than in healthy controls (apex-base difference 7.6% ± 4.2% vs 3.3% ± 2.4%, p < 0.0001). Conclusions: Pediatric patients with TOF and a severe pulmonary regurgitation show an enhanced longitudinal strain when compared to patients with milder regurgitation or to control subjects. In addition, mean RV circumferential strain of the patients is significantly enhanced compared to healthy individuals.