    Intraoperative Safety and Postoperative Complications After SMILE Pro: A Retrospective Case Series of 916 Eyes

    by David Beckers, Florian Kretz, Lena Beckers, Amr Saad, Karsten Klabe, Hakan Kaymak, Mücella Kirca, Detlev Breyer

    Purpose: To report intraoperative safety and postoperative complications after small-incision lenticule extraction using the 2 MHz femtosecond platform (SMILE Pro; VisuMax 800) in routine practice. Methods: Retrospective consecutive case series at a single center. All planned SMILE Pro procedures were analyzed (916 eyes from 482 patients). Outcomes included completion rate, intraoperative events, postoperative complications stratified as 3 months, and retreatment rate. Results: Baseline age was 32.9 ± 6.9 years; average preoperative refraction was −3.60 ± 1.90/−0.87 ± 0.76 D (sphere/cylinder) with best corrected visual acuity of −0.08 ± 0.07 logMAR. Procedures were completed in 911 of 916 eyes (99.45%). Suction loss occurred in six eyes (0.66%); one was completed after redocking, four were converted (two ICL, two femtosecond LASIK) and one did not receive a second procedure. No failed lenticule separations occurred. Retreatment was performed in 14 eyes (1.54%): 11 re-LASIK, 2 ICL, and 1 cataract extraction. Early postoperative events (<3 months) were mainly superficial punctate keratitis (3.51%) and dry eye (1.32%); beyond 3 months, events remained uncommon (dry eye 1.65%, photopsia/halo/glare 0.88%). No severe or sight-threatening complications were observed. Conclusions: SMILE Pro on the VisuMax 800 showed a high completion rate, rare intraoperative disruption, low retreatment, and rare, mostly mild postoperative events. These findings support a favorable early safety profile in routine practice; longer-term follow-up is warranted.

  • Open Access

    Randomized comparative multicenter study assessing two dispersive viscosurgical devices for cataract surgery

    by Ekkehard Fabian, Andrea Janeková, Pablo de Arriba Palomero, Pedro Tañá-Rivero, Daniel Böhringer, Florian T.A. Kretz, Jiří Pašta, Rosario Touriño-Peralba

    Purpose: To compare 2 dispersive ophthalmic viscosurgical devices (OVDs), Z-HYALCOAT (investigational) and HEALON EndoCoat (control), with a 3-month postoperative follow-up. Setting: Multicenter study conducted in 11 sites across Europe. Design: Prospective, randomized, masked, multicenter postmarket study. Methods: Adult participants having clear intraocular media excluding the presence of cataract and scheduled for uneventful age-related cataract removal by phacoemulsification and intraocular lens implantation in the capsular bag with sole administration of either investigational or control device as per randomization scheme were included in this study. Primary endpoint was the incidence of intraocular pressure (IOP) ≥30 mm Hg. Other endpoints included slitlamp observations, corneal endothelial cell density (ECD), surgeon-reported device functionality, and rate of adverse events and device deficiencies. Results: 242 participants were treated in this study (123 with the investigational OVD and 119 with the control OVD). In per-protocol population, 13 eyes (11.2%) from the investigational group and 19 (17.0%) from the control group reached an IOP equal to or higher than 30 mm Hg at 8 hours after device use. Slitlamp examinations performed up to 3 months did not reveal any relevant differences between the groups. ECD loss was also similar between the groups. Surgeon-reported OVD functionality was generally favorable and comparable for both devices. Conclusions: This investigation proved the noninferiority of Z-HYALCOAT to HEALON EndoCoat in IOP spikes and showed the 2 devices to be highly similar in all evaluated aspects.


  • Open Access

    Analyzing the Relationship Between IOL Fixation and PCO Prevention

    by David Beckers, Florian Kretz, Jodhbir Mehta, Lena Beckers

    Background: Posterior capsular opacification (PCO) remains the most common long-term complication following cataract surgery. This correspondence investigates whether intraocular lens (IOL) fixation type influences PCO risk by comparing Nd:YAG capsulotomy rates between capsulotomy-fixated (FEMTIS) and conventional in-the-bag IOLs with similar material and edge profiles. Methods: A systematic review was conducted. Eligible studies reporting quantitative YAG rates at ≥3 months of follow-up were included. Results: FEMTIS IOLs demonstrated lower capsulotomy rates (3.1% at 12 months) compared to in-the-bag LENTIS lenses (4.7% at 12 months), despite identical optic designs and identical material. Conclusions: This suggests that capsulotomy fixation may promote closer capsule–optic contact and reduce the potential space for lens epithelial cell migration. While data are limited by study heterogeneity and follow-up duration, early evidence supports anterior fixation as a potential strategy to reduce PCO risk and improve long-term capsular clarity. Further prospective studies are warranted. Limitations include heterogeneous study designs, relatively short follow-up, and reliance on Nd:YAG capsulotomy as the sole endpoint.


  • Open Access

    Visual performance and patient preference with bilateral implantation of an extended depth of focus or combined implantation of an extended depth of focus/trifocal intraocular lens

    by Jonathan Moore, Jens Østergaard, Florian Kretz

    Purpose: Evaluate postoperative visual performance in patients with bilaterally implanted AT LARA or AT LARA/AT LISA tri (Carl Zeiss AG, Jena, Germany) intraocular lenses. Methods: Multicentered, comparative, open-label, retrospective/prospective study. Post-IOL implantation, patients were prospectively enrolled into this study; preoperative patient data were collected retrospectively. Follow-up was at 2–4 and 5–8 months post-surgery. The primary endpoint was binocular best corrected distance visual acuity (CDVA). The study was retrospectively registered on clinicaltrials.gov (#NCT05462067). Results: Seventy-one patients (142 eyes) were enrolled; 67 patients (134 eyes) have 5–8 months data. The mean binocular CDVA at 2–4 months was -0.10 ± 0.06 logMAR in the bilateral AT LARA group (“bilateral”) and -0.11 ± 0.09 logMAR in the combined implantation AT LARA/ AT LISA tri group (“combined implantation”); (P = 0.4856). At 5–8 months, mean binocular CDVA was -0.13 ± 0.06 logMAR in the bilateral group and -0.11 ± 0.09 in the combined implantation group (P = 0.4003). At 5–8 months, more eyes in the bilateral group attained 0.2 logMAR or better binocular uncorrected intermediate VA (UIVA; 67 cm) than those in the combined implantation group (100% vs. 94%, respectively). The bilateral group achieved a mean of 0.24 ± 0.11 logMAR in uncorrected near VA (UCNVA), compared to a mean of 0.16 ± 0.12 logMAR in the combined implantation group at 5–8 months (P = 0.0041). Conclusions: A combined implantation approach (AT LARA in the distance dominant eye/AT LISA tri in the non-dominant eye) produced similar CDVA outcomes but better UCNVA as bilateral implantation with the AT LARA. UIVA was comparable between groups. No new safety concerns were reported.


  • Open Access

    Clinical safety and efficacy of a hydrophilic acrylic intraocular lens in a real-world population: a 1-year follow-up retro-prospective study

    by Björn Johansson, Ana C. S. Daniel, Claudia Herbers, Matthias Gerl, Florian T. A. Kretz

    Background: This multicentre, retro-prospective real-world study evaluated the visual, refractive and safety outcomes of a monofocal lens 1 year after implantation in cataract patients with or without pre-existing ocular pathologies. Methods: Records from 4 centres in Germany and Sweden were reviewed to select eyes with aged-related cataracts, having undergone crystalline lens extraction by phacoemulsification and implantation of a CT ASPHINA 409 IOL. Preoperative, 1-month and 3-month postoperative data was collected retrospectively. In addition, included patients attended a prospective visit 12 months or later after surgery. The examination included: monocular uncorrected (UDVA) and corrected distance visual acuity (CDVA), subjective refraction, slit-lamp examination, optical biometry, intraocular pressure (IOP), endothelial cell count and postoperative complications. Results: 282 eyes, including 94 with pre-existing ocular pathologies, were analysed. Twelve months after the surgery, 95% of eyes achieved monocular CDVA equal or better than 0.3 logMAR, mean postoperative CDVA was 0.06 ± 0.17 logMAR, and mean UDVA 0.31 ± 0.29 logMAR. Visual acuity outcomes were better in eyes with no pre-existing ocular pathologies, but both groups showed a statistically significant improvement after surgery compared with preoperative values (p ≤ 0.002). The mean sphere and spherical equivalent values also improved significantly postoperatively (p = 0.003). Overall, 62.1% of eyes had spherical equivalent within ±0.5 D and 80.9% within ±1.0 D. The IOL was stable in the capsular bag as demonstrated by tilt and decentration measurements. IOP, corneal status, and endothelial cell count values were in the normal range. Nd:YAG treatment was performed on 9.9% of the eyes. Conclusion: The implantation of the monofocal CT ASPHINA 409 IOL was beneficial to restore vision in eyes with or without concomitant ocular pathology such as macular degeneration, glaucoma, Sicca syndrome, epiretinal membrane, cornea guttata, or amblyopia. Good to excellent long-term visual and refractive outcomes, and a low rate of complications in both healthy and pathological eyes were found 12 months after the surgery. Trial registration: Trial registered on under the identification NCT03145103 (date of registration 9 May 2017).


  • Proteomics of vitreous in neovascular age-related macular degeneration

    by Matthias Nobl, Michael Reich, Ivanka Dacheva, Justyna Siwy, William Mullen, Joost P. Schanstra, Chul Young Choi, Jürgen Kopitz, Florian T.A. Kretz, Gerd U. Auffarth, et al.


  • Open Access

    Clinical Evaluation of Functional Vision of +1.5 Diopters near Addition, Aspheric, Rotational Asymmetric Multifocal Intraocular Lens

    by Florian Tobias Alwin Kretz, Rahmin Khoramnia, Mary Safwat Attia, Michael Janusz Koss, Katharina Linz, Gerd Uwe Auffarth

    Kretz FT, et al. Korean J Ophthalmol. 2016 Oct;30(5):382-389. https://doi.org/10.3341/kjo.2016.30.5.382


  • Open Access

    Visual Outcomes, Patient Satisfaction and Spectacle Independence with a Trifocal Diffractive Intraocular Lens

    by Florian Tobias Alwin Kretz, Chul Young Choi, Matthias Müller, Matthias Gerl, Ralf Helmar Gerl, Gerd Uwe Auffarth

    Kretz FT, et al. Korean J Ophthalmol. 2016 Jun;30(3):180-191. https://doi.org/10.3341/kjo.2016.30.3.180


  • Randomized Clinical Trial to Compare Micropulse Photocoagulation Versus Half-dose Verteporfin Photodynamic Therapy in the Treatment of Central Serous Chorioretinopathy

    by Florian T.A. Kretz, Isabell Beger, Frank Koch, Katarrzyna Nowomiejska, Gerd U. Auffarth, Michael J. Koss

    BACKGROUND AND OBJECTIVE: To evaluate subthreshold diode-laser micropulse (SDM) versus half-dose verteporfin photodynamic therapy (hd-PDT) in central serous chorioretinopathy (CSC). PATIENTS AND METHODS: 62 eyes of 62 patients were prospectively followed for changes in fluorescein angiography (FA), fundus autofluorescence (FAF), central macular thickness (CMT), best-corrected visual acuity (BCVA), and contrast visual acuity (CVA) after SDM (n = 20) or hdPDT (n = 24). CSC observation served as control group (n = 18). RESULTS: Both treatment groups (60% SDM vs. 66.7% hdPDT) showed significant improvement in reduction of leakage activity compared to the control group (37.5%) at 16 weeks. CMT decreased by 69.7 µm (SDM), 109.8 µm (hdPDT), and 89 µm (control). BCVA improved by +6.7 (SDM group), +8.5 (hdPDT), and +1.5 ETDRS letters (control). CVA was best improved in the hdPDT group. No secondary RPE alterations could be detected by FAF after any intervention. CONCLUSION: In comparison to the control group, hdPDT and SDM resulted in reduced leakage activity in FA and enhanced photopic and scotopic visual acuity in patients with CSC. [ Ophthalmic Surg Lasers Imaging Retina . 2015;46:837–843.]


  • Open Access

    Binocular function to increase visual outcome in patients implanted with a diffractive trifocal intraocular lens

    by Florian T. A. Kretz, Matthias Müller, Matthias Gerl, Ralf H. Gerl, Gerd U. Auffarth

    To evaluate binocular visual outcome for near, intermediate and distance compared to monocular visual outcome at the same distances in patients implanted with a diffractive trifocal intraocular lens (IOL). The study comprised of 100 eyes of 50 patients that underwent bilateral refractive lens exchange or cataract surgery with implantation of a multifocal diffractive IOL (AT LISA tri 839MP, Carl Zeiss Meditech, Germany). A complete ophthalmological examination was performed preoperatively and 3 month postoperatively. The main outcome measures were monocular and binocular uncorrected distance (UDVA), corrected distance (CDVA), uncorrected intermediate (UIVA), and uncorrected near visual acuities (UNVA), keratometry, and manifest refraction. The mean age was 59.28 years ± 9.6 [SD] (range 44–79 years), repectively. There was significant improvement in UDVA, UIVA, UNVA and CDVA. Comparing the monocular results to the binocular results there was a statistical significant better binocular outcome in all distances (UDVA p = 0.036; UIVA p < 0.0001; UNVA p = 0.001). The postoperative manifest refraction was in 86 % of patients within ± 0.50 [D]. The trifocal IOL improved near, intermediate, and distance vision compared to preoperatively. In addition a statistical significant increase for binocular visual function in all distances could be found. German Clinical Trials Register (DRKS) DRKS00007837