Hendrik Doering
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Hendrik Doering has a total of 16 co-authors. Here are the top co-authors by number of shared publications:
- Christian Martin Schmitt
Department of Oral and Maxillofacial Surgery, University of Erlangen-Nuremberg, Erlangen, Germany
3 shared publications Karl Andreas Schlegel
Department of Oral and Maxillofacial Surgery University of Erlangen‐Nuremberg Erlangen Germany
2 shared publications- Rainer Lutz
Department of Oral and Maxillofacial Surgery, University Hospital Erlangen, Erlangen, Germany
2 shared publications Carlos Brito
Department of Preventive Dentistry University of Toronto Toronto Ontario Canada
1 shared publicationFriedrich Wilhelm Neukam
Department of Oral and Maxillofacial Surgery University of Erlangen‐Nuremberg Erlangen Germany
1 shared publicationG. M. Aboodi
Group in Matrix Dynamics Faculty of Dentistry University of Toronto Toronto ON Canada
1 shared publication
Latest Publications
- 14 July 2014
- Published by Wiley in Journal of Periodontal Research
- Vol. 50 (3) , 330-336
Quantifying oral inflammatory load: oral neutrophil counts in periodontal health and disease
Background and Objective: Neutrophils are the primary white blood cells that are recruited to fight the initial phases of microbial infections. While healthy norms have been determined for circulating blood neutrophil counts in order to identify patients with suspected systemic infections, the levels of oral neutrophils (oPMNs) in oral health and in the presence of periodontal diseases have not been described. It is important to address this deficiency in our knowledge as neutrophils are the primary immune cell present in the crevicular fluid and oral environment and previous work has suggested that they may be good indicators of overall oral inflammation and periodontal disease severity. The objective of this study was to measure oPMN counts obtained in a standardized oral rinse from healthy patients and from those with chronic periodontal disease in order to determine if oPMN levels have clinical relevance as markers of periodontal inflammation. A parallel goal of this investigation was to introduce the concept of ‘oral inflammatory load’, which constitutes the inflammatory burden experienced by the body as a consequence of oral inflammatory disease.Material and Methods: Periodontal examinations of patients with a healthy periodontium and chronic periodontal disease were performed (n = 124). Two standardized consecutive saline rinses of 30 s each were collected before patient examination and instrumentation. Neutrophils were quantified in the rinse samples and correlated with the clinical parameters and periodontal diagnosis.Results: Average oPMN counts were determined for healthy patients and for those with mild, moderate and severe chronic periodontal diseases. A statistically significant correlation was found between oPMN counts and deep periodontal probing, sites with bleeding on probing and overall severity of periodontal disease.Conclusions: oPMN counts obtained through a 30‐s oral rinse are a good marker of oral inflammatory load and correlate with measures of periodontal disease severity.
- 14 July 2014
- Published by Wiley in Journal of Periodontal Research
- Vol. 50 (3) , 330-336
Quantifying oral inflammatory load: oral neutrophil counts in periodontal health and disease
Background and Objective: Neutrophils are the primary white blood cells that are recruited to fight the initial phases of microbial infections. While healthy norms have been determined for circulating blood neutrophil counts in order to identify patients with suspected systemic infections, the levels of oral neutrophils (oPMNs) in oral health and in the presence of periodontal diseases have not been described. It is important to address this deficiency in our knowledge as neutrophils are the primary immune cell present in the crevicular fluid and oral environment and previous work has suggested that they may be good indicators of overall oral inflammation and periodontal disease severity. The objective of this study was to measure oPMN counts obtained in a standardized oral rinse from healthy patients and from those with chronic periodontal disease in order to determine if oPMN levels have clinical relevance as markers of periodontal inflammation. A parallel goal of this investigation was to introduce the concept of ‘oral inflammatory load’, which constitutes the inflammatory burden experienced by the body as a consequence of oral inflammatory disease.Material and Methods: Periodontal examinations of patients with a healthy periodontium and chronic periodontal disease were performed (n = 124). Two standardized consecutive saline rinses of 30 s each were collected before patient examination and instrumentation. Neutrophils were quantified in the rinse samples and correlated with the clinical parameters and periodontal diagnosis.Results: Average oPMN counts were determined for healthy patients and for those with mild, moderate and severe chronic periodontal diseases. A statistically significant correlation was found between oPMN counts and deep periodontal probing, sites with bleeding on probing and overall severity of periodontal disease.Conclusions: oPMN counts obtained through a 30‐s oral rinse are a good marker of oral inflammatory load and correlate with measures of periodontal disease severity.
- Top Cited Papers
- 9 May 2013
- Published by Wiley in Journal of Biomedical Materials Research Part A
- Vol. 102 (2) , 552-574
Performance of conical abutment (Morse Taper) connection implants: A systematic review
In this systematic review, we aimed to compare conical versus nonconical implant–abutment connection systems in terms of their in vitro and in vivo performances. An electronic search was performed using PubMed, Embase, and Medline databases with the logical operators: “dental implant” AND “dental abutment” AND (“conical” OR “taper” OR “cone”). Names of the most common conical implant–abutment connection systems were used as additional key words to detect further data. The search was limited to articles published up to November 2012. Recent publications were also searched manually in order to find any relevant studies that might have been missed using the search criteria noted above. Fifty‐two studies met the inclusion criteria and were included in this systematic review. As the data and methods, as well as types of implants used was so heterogeneous, this mitigated against the performance of meta‐analysis. In vitro studies indicated that conical and nonconical abutments showed sufficient resistance to maximal bending forces and fatigue loading. However, conical abutments showed superiority in terms of seal performance, microgap formation, torque maintenance, and abutment stability. In vivo studies (human and animal) indicated that conical and nonconical systems are comparable in terms of implant success and survival rates with less marginal bone loss around conical connection implants in most cases. This review indicates that implant systems using a conical implant–abutment connection, provides better results in terms of abutment fit, stability, and seal performance. These design features could lead to improvements over time versus nonconical connection systems. © 2013 Wiley Periodicals, Inc. J Biomed Mater Res Part A: 102A: 552–574, 2014.
- 9 May 2013
- Published by Wiley in Journal of Biomedical Materials Research Part A
- Vol. 102 (2) , 552-574
Top Cited PapersPerformance of conical abutment (Morse Taper) connection implants: A systematic review
In this systematic review, we aimed to compare conical versus nonconical implant–abutment connection systems in terms of their in vitro and in vivo performances. An electronic search was performed using PubMed, Embase, and Medline databases with the logical operators: “dental implant” AND “dental abutment” AND (“conical” OR “taper” OR “cone”). Names of the most common conical implant–abutment connection systems were used as additional key words to detect further data. The search was limited to articles published up to November 2012. Recent publications were also searched manually in order to find any relevant studies that might have been missed using the search criteria noted above. Fifty‐two studies met the inclusion criteria and were included in this systematic review. As the data and methods, as well as types of implants used was so heterogeneous, this mitigated against the performance of meta‐analysis. In vitro studies indicated that conical and nonconical abutments showed sufficient resistance to maximal bending forces and fatigue loading. However, conical abutments showed superiority in terms of seal performance, microgap formation, torque maintenance, and abutment stability. In vivo studies (human and animal) indicated that conical and nonconical systems are comparable in terms of implant success and survival rates with less marginal bone loss around conical connection implants in most cases. This review indicates that implant systems using a conical implant–abutment connection, provides better results in terms of abutment fit, stability, and seal performance. These design features could lead to improvements over time versus nonconical connection systems. © 2013 Wiley Periodicals, Inc. J Biomed Mater Res Part A: 102A: 552–574, 2014.
- 13 February 2012
- Published by Wiley in Clinical Oral Implants Research
- Vol. 24 (5) , 576-585
Histological results after maxillary sinus augmentation with Straumann® BoneCeramic, Bio‐Oss®, Puros®, and autologous bone. A randomized controlled clinical trial
Objective: This investigation focused on a comparison of clinical and histological characteristics after sinus floor augmentation with biphasic calcium phosphate (BCP, Straumann BoneCeramic®), anorganic bovine bone (ABB, Geistlich Bio‐Oss®), mineralized cancellous bone allograft (MCBA, Zimmer Puros®), or autologous bone (AB).Materials and methods: Thirty consecutive patients with a posterior edentulous maxillary situation and a vertical bone height less than or equal to 4 mm were included in this study. A two‐stage procedure was carried out. After augmentation of the maxillary sinus with ABB, BCP, MCBA, or AB followed by a healing period of 5 months, biopsies were taken with simultaneous implant placement. The samples were analyzed using microradiography and histology.Results: Ninety‐four implants were placed in the augmented positions and 53 bone biopsies were taken and evaluated. The bone volume fraction of newly formed bone was measured as 30.28 ± 2.16% for BCP, 24.9 ± 5.67% for ABB, 41.74 ± 2.1% for AB, and 35.41 ± 2.78% for MCBA with significant increases in bone volume of AB vs. BCP and ABB, and MCBA vs. ABB samples. Significantly different residual bone substitute material was measured as 15.8 ± 2.1% in the BCP group and 21.36 ± 4.83% in the ABB group.Conclusion: As it provides the highest rate of de novo bone formation, AB can be considered to remain the gold standard in sinus floor augmentation. All tested control materials showed comparable results and are suitable for maxillary sinus augmentation.
- 13 February 2012
- Published by Wiley in Clinical Oral Implants Research
- Vol. 24 (5) , 576-585
Histological results after maxillary sinus augmentation with Straumann® BoneCeramic, Bio‐Oss®, Puros®, and autologous bone. A randomized controlled clinical trial
Objective: This investigation focused on a comparison of clinical and histological characteristics after sinus floor augmentation with biphasic calcium phosphate (BCP, Straumann BoneCeramic®), anorganic bovine bone (ABB, Geistlich Bio‐Oss®), mineralized cancellous bone allograft (MCBA, Zimmer Puros®), or autologous bone (AB).Materials and methods: Thirty consecutive patients with a posterior edentulous maxillary situation and a vertical bone height less than or equal to 4 mm were included in this study. A two‐stage procedure was carried out. After augmentation of the maxillary sinus with ABB, BCP, MCBA, or AB followed by a healing period of 5 months, biopsies were taken with simultaneous implant placement. The samples were analyzed using microradiography and histology.Results: Ninety‐four implants were placed in the augmented positions and 53 bone biopsies were taken and evaluated. The bone volume fraction of newly formed bone was measured as 30.28 ± 2.16% for BCP, 24.9 ± 5.67% for ABB, 41.74 ± 2.1% for AB, and 35.41 ± 2.78% for MCBA with significant increases in bone volume of AB vs. BCP and ABB, and MCBA vs. ABB samples. Significantly different residual bone substitute material was measured as 15.8 ± 2.1% in the BCP group and 21.36 ± 4.83% in the ABB group.Conclusion: As it provides the highest rate of de novo bone formation, AB can be considered to remain the gold standard in sinus floor augmentation. All tested control materials showed comparable results and are suitable for maxillary sinus augmentation.
- 1 November 2011
- Published by Wiley in Clinical Oral Implants Research
- Vol. 24 (4) , 450-460
Bio‐Oss® blocks combined with BMP‐2 and VEGF for the regeneration of bony defects and vertical augmentation
Objectives: The aim of this study was to evaluate the bone formation rate and osseointegration of Bio‐Oss® blocks combined with rhBMP‐2 and rhVEGF in bony defects and after vertical augmentation.Material and methods: Bio‐Oss® blocks plus rhBMP‐2 (BMP), Bio‐Oss® blocks plus rhVEGF (VEGF), or Bio‐Oss® blocks plus rhBMP‐2 and rhVEGF (BMPVEGF) were inserted in “critical size defects” (CSD) in the calvariae of adult pigs. Control defects were filled with collagen carrier (Lyostypt®) plus growth factors and untreated Bio‐Oss® blocks (CO). In a second group, Bio‐Oss® blocks plus growth factors and untreated Bio‐Oss® blocks were used for vertical augmentation of the calvariae. In the first group, the investigation time was 30 days, in the second group it was 30 and 60 days. The bone samples were investigated histomorphometrically, and the newly formed bone (BV/TV) was judged by microradiographic investigation.Results: In the CSD model, the newly formed bone in the region of interest was not significantly different within the groups. In the second setting, the inserted bone blocks exhibited sufficient volume stability with increasing bone formation up to 9.33% ± 3.92% for BMP, 10.42% ± 1.81% for BMP/VEGF, 11.01% ± 4.78% for VEGF, and 10.02% ± 5.43% for the control group after 60 days.Conclusion: In the chosen setting and time frame, de novo bone formation did not increase with the additional use of growth factors.
- 1 November 2011
- Published by Wiley in Clinical Oral Implants Research
- Vol. 24 (4) , 450-460
Bio‐Oss® blocks combined with BMP‐2 and VEGF for the regeneration of bony defects and vertical augmentation
Objectives: The aim of this study was to evaluate the bone formation rate and osseointegration of Bio‐Oss® blocks combined with rhBMP‐2 and rhVEGF in bony defects and after vertical augmentation.Material and methods: Bio‐Oss® blocks plus rhBMP‐2 (BMP), Bio‐Oss® blocks plus rhVEGF (VEGF), or Bio‐Oss® blocks plus rhBMP‐2 and rhVEGF (BMPVEGF) were inserted in “critical size defects” (CSD) in the calvariae of adult pigs. Control defects were filled with collagen carrier (Lyostypt®) plus growth factors and untreated Bio‐Oss® blocks (CO). In a second group, Bio‐Oss® blocks plus growth factors and untreated Bio‐Oss® blocks were used for vertical augmentation of the calvariae. In the first group, the investigation time was 30 days, in the second group it was 30 and 60 days. The bone samples were investigated histomorphometrically, and the newly formed bone (BV/TV) was judged by microradiographic investigation.Results: In the CSD model, the newly formed bone in the region of interest was not significantly different within the groups. In the second setting, the inserted bone blocks exhibited sufficient volume stability with increasing bone formation up to 9.33% ± 3.92% for BMP, 10.42% ± 1.81% for BMP/VEGF, 11.01% ± 4.78% for VEGF, and 10.02% ± 5.43% for the control group after 60 days.Conclusion: In the chosen setting and time frame, de novo bone formation did not increase with the additional use of growth factors.