Mohsen Amjadian
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Mohsen Amjadian has a total of 11 co-authors. Here are the top co-authors by number of shared publications:
Anil K. Agrawal
The City College of New York (United States)
8 shared publicationsAnil K Agrawal
Department of Civil and Environmental Engineering, The City University of New York, The City College of New York, New York, USA
3 shared publicationsAfshin Kalantari
Structural Engineering Research Center, International Institute of Earthquake Engineering and Seismology, Iran
2 shared publications- Anil. K. Agrawal
Professor of Civil Engineering, Dept. of Civil Engineering, City College of New York, New York, NY 10031
2 shared publications - Hani Nassif
Rutgers, The State University of New Jersey
2 shared publications A.K. Agrawal
1 shared publication
Latest Publications
- Top Cited Papers
- 25 February 2026
- Published by Elsevier in Engineering Structures
- Vol. 354
A multi-resonator periodic metamaterial with localized energy absorption for seismic wave attenuation in buildings
- 25 February 2026
- Published by Elsevier in Engineering Structures
- Vol. 354
Top Cited PapersA multi-resonator periodic metamaterial with localized energy absorption for seismic wave attenuation in buildings
- 27 May 2025
- Published by Springer Nature in Journal of Vibration Engineering & Technologies
- Vol. 13 (5) , 1-24
Passive Vibration Control of Curved Bridges using Multiple Tuned Mass Dampers Subjected to Bidirectional Ground Motions
- 27 May 2025
- Published by Springer Nature in Journal of Vibration Engineering & Technologies
- Vol. 13 (5) , 1-24
Passive Vibration Control of Curved Bridges using Multiple Tuned Mass Dampers Subjected to Bidirectional Ground Motions
- Open Access
Modeling, Design, and Laboratory Testing of a Passive Friction Seismic Metamaterial Base Isolator (PFSMBI)
This paper focuses on the theoretical and analytical modeling of a novel seismic isolator termed the Passive Friction Mechanical Metamaterial Seismic Isolator (PFSMBI) system, which is designed for seismic hazard mitigation in multi-story buildings. The PFSMBI system consists of a lattice structure composed of a series of identical small cells interconnected by layers made of viscoelastic materials. The main function of the lattice is to shift the fundamental natural frequency of the building away from the dominant frequency of earthquake excitations by creating low-frequency bandgaps (FBGs) below 20 Hz. In this configuration, each unit cell contains an inner resonator that slides over a friction surface while it is tuned to vibrate at the fundamental natural frequency of the building. This resonance enhances the energy dissipation capacity of the PFSMBI system. After deriving the governing equations for four selected lattice configurations (i.e., Cases 1–4), a parametric study is performed to optimize the PFSMBI system for a wide range of harmonic ground motion frequencies. In this study, we examine how key parameters, such as the mass ratios of the cells and resonators, tuning frequency ratios, the number of cells, and the coefficient of friction, affect the system’s performance. The PFSMBI system is then incorporated into the dynamic model of a six-story base-isolated building to evaluate its effectiveness in reducing the floor acceleration and inter-story drift under actual earthquake ground motion records. This dynamic model is used to investigate the effect of stick–slip motion (SSM) on the energy dissipation performance of a PFSMBI system by employing the LuGre friction model. The numerical results show that the optimized PFSMBI system, through its lattice structure and frictional resonators, effectively reduces floor acceleration and inter-story drift by leveraging FBGs and frictional energy dissipation, particularly when SSM effects are properly accounted for. Finally, a small-scale prototype of the PFSMBI system with two cells is developed to verify the effect of SSM. This experimental validation highlights that neglecting SSM can lead to an overestimation of the energy dissipation performance of PFSMBI systems.
Open AccessModeling, Design, and Laboratory Testing of a Passive Friction Seismic Metamaterial Base Isolator (PFSMBI)
This paper focuses on the theoretical and analytical modeling of a novel seismic isolator termed the Passive Friction Mechanical Metamaterial Seismic Isolator (PFSMBI) system, which is designed for seismic hazard mitigation in multi-story buildings. The PFSMBI system consists of a lattice structure composed of a series of identical small cells interconnected by layers made of viscoelastic materials. The main function of the lattice is to shift the fundamental natural frequency of the building away from the dominant frequency of earthquake excitations by creating low-frequency bandgaps (FBGs) below 20 Hz. In this configuration, each unit cell contains an inner resonator that slides over a friction surface while it is tuned to vibrate at the fundamental natural frequency of the building. This resonance enhances the energy dissipation capacity of the PFSMBI system. After deriving the governing equations for four selected lattice configurations (i.e., Cases 1–4), a parametric study is performed to optimize the PFSMBI system for a wide range of harmonic ground motion frequencies. In this study, we examine how key parameters, such as the mass ratios of the cells and resonators, tuning frequency ratios, the number of cells, and the coefficient of friction, affect the system’s performance. The PFSMBI system is then incorporated into the dynamic model of a six-story base-isolated building to evaluate its effectiveness in reducing the floor acceleration and inter-story drift under actual earthquake ground motion records. This dynamic model is used to investigate the effect of stick–slip motion (SSM) on the energy dissipation performance of a PFSMBI system by employing the LuGre friction model. The numerical results show that the optimized PFSMBI system, through its lattice structure and frictional resonators, effectively reduces floor acceleration and inter-story drift by leveraging FBGs and frictional energy dissipation, particularly when SSM effects are properly accounted for. Finally, a small-scale prototype of the PFSMBI system with two cells is developed to verify the effect of SSM. This experimental validation highlights that neglecting SSM can lead to an overestimation of the energy dissipation performance of PFSMBI systems.
- 6 October 2023
- Published by Springer Nature
- p. 221-228
Vibration Control Using Frictional Tuned Mass Dampers with Stick-Slip Motion
- 6 October 2023
- Published by Springer Nature
- p. 221-228
Vibration Control Using Frictional Tuned Mass Dampers with Stick-Slip Motion
- Open Access
Development of An Analytical Method for Design of Electromagnetic Energy Harvesters with Planar Magnetic Arrays
In this paper, an analytical method is proposed for the modeling of electromagnetic energy harvesters (EMEH) with planar arrays of permanent magnets. It is shown that the proposed method can accurately simulate the generation of electrical power in an EMEH from the vibration of a bridge subjected to traffic loading. The EMEH consists of two parallel planar arrays of 5 by 5 small cubic permanent magnets (PMs) that are firmly attached to a solid aluminum base plate, and a thick rectangular copper coil that is connected to the base plate through a set of four springs. The coil can move relative to the two magnetic arrays when the base plate is subjected to an external excitation caused by the vehicles passing over the bridge. The proposed analytical model is used to formulize the magnetic interaction between the magnetic arrays and the moving coil and the electromechanical coupling between both the electrical and mechanical domains of the EMEH. A finite element model is developed to verify the accuracy of the proposed analytical model to compute the magnetic force acting on the coil. The analytical model is then used to conduct a parametric study on the magnetic arrays to optimize the arrangement of the PM poles, thereby maximize the electrical power outputted from the EMEH. The results of parametric analysis using the proposed analytical method show that the EMEH, under the resonant condition, can deliver an average electrical power as large as 500 mW when the PM poles are arranged alternately along the direction of vibration for a peak base acceleration of 0.1 g. A proof-of-concept prototype of the EMEH is fabricated to test its performance for a given arrangement of PMs subjected to vibration in both the lab and field environments.
Open AccessDevelopment of An Analytical Method for Design of Electromagnetic Energy Harvesters with Planar Magnetic Arrays
In this paper, an analytical method is proposed for the modeling of electromagnetic energy harvesters (EMEH) with planar arrays of permanent magnets. It is shown that the proposed method can accurately simulate the generation of electrical power in an EMEH from the vibration of a bridge subjected to traffic loading. The EMEH consists of two parallel planar arrays of 5 by 5 small cubic permanent magnets (PMs) that are firmly attached to a solid aluminum base plate, and a thick rectangular copper coil that is connected to the base plate through a set of four springs. The coil can move relative to the two magnetic arrays when the base plate is subjected to an external excitation caused by the vehicles passing over the bridge. The proposed analytical model is used to formulize the magnetic interaction between the magnetic arrays and the moving coil and the electromechanical coupling between both the electrical and mechanical domains of the EMEH. A finite element model is developed to verify the accuracy of the proposed analytical model to compute the magnetic force acting on the coil. The analytical model is then used to conduct a parametric study on the magnetic arrays to optimize the arrangement of the PM poles, thereby maximize the electrical power outputted from the EMEH. The results of parametric analysis using the proposed analytical method show that the EMEH, under the resonant condition, can deliver an average electrical power as large as 500 mW when the PM poles are arranged alternately along the direction of vibration for a peak base acceleration of 0.1 g. A proof-of-concept prototype of the EMEH is fabricated to test its performance for a given arrangement of PMs subjected to vibration in both the lab and field environments.
- 22 March 2021
- Published by SPIE-Intl Soc Optical Eng
- p. 49
Feasibility of using a high-power electromagnetic energy harvester to power structural health monitoring sensors and systems in transportation infrastructures
SPIE Digital Library Proceedings
- 22 March 2021
- Published by SPIE-Intl Soc Optical Eng
- p. 49
Feasibility of using a high-power electromagnetic energy harvester to power structural health monitoring sensors and systems in transportation infrastructures
SPIE Digital Library Proceedings
- 27 February 2020
- Published by SAGE Publications in Journal of Intelligent Material Systems and Structures
- Vol. 31 (7) , 998-1014
Planar arrangement of permanent magnets in design of a magneto-solid damper by finite element method
This article studies the energy dissipation mechanism of a proposed magneto-solid damper using a three-dimensional finite element model developed in COMSOL Multiphysics software. The energy dissipation mechanism of the magneto-solid damper dissipates energy through combined actions of friction and eddy current damping. The key components of the magneto-solid damper are a steel plate, two copper plates placed on two sides of the steel plate in parallel, and two planar arrays of permanent magnets each one placed between the steel plate and one of the copper plates. These arrays are kept away from the steel and copper plates through narrow gaps; the gaps between them and the steel plate are filled with thin friction pads made of non-magnetic materials. The attractive magnetic interaction between the permanent magnet arrays and the steel plate provides the normal force for the friction developed between the friction pads and the steel plate when the permanent magnet arrays move relative to the steel plate. The motion of the permanent magnet arrays relative to the copper plates, on the other hand, provides the eddy current damping. The main contribution of this article is to optimize the pole arrangement of the permanent magnets and demonstrate that how the optimum pole arrangement can affect the energy dissipation capacity of the magneto-solid damper. The analysis results show that, for a given number and size of the permanent magnets, alternate arrangement of the poles of permanent magnets along the direction of their motion is the most optimal case resulting in large and smooth hysteresis force–displacement loops. This pole arrangement has also been used to find the optimum size of the steel and copper plates by addressing edge and skin effects in the design of the damper.
- 27 February 2020
- Published by SAGE Publications in Journal of Intelligent Material Systems and Structures
- Vol. 31 (7) , 998-1014
Planar arrangement of permanent magnets in design of a magneto-solid damper by finite element method
This article studies the energy dissipation mechanism of a proposed magneto-solid damper using a three-dimensional finite element model developed in COMSOL Multiphysics software. The energy dissipation mechanism of the magneto-solid damper dissipates energy through combined actions of friction and eddy current damping. The key components of the magneto-solid damper are a steel plate, two copper plates placed on two sides of the steel plate in parallel, and two planar arrays of permanent magnets each one placed between the steel plate and one of the copper plates. These arrays are kept away from the steel and copper plates through narrow gaps; the gaps between them and the steel plate are filled with thin friction pads made of non-magnetic materials. The attractive magnetic interaction between the permanent magnet arrays and the steel plate provides the normal force for the friction developed between the friction pads and the steel plate when the permanent magnet arrays move relative to the steel plate. The motion of the permanent magnet arrays relative to the copper plates, on the other hand, provides the eddy current damping. The main contribution of this article is to optimize the pole arrangement of the permanent magnets and demonstrate that how the optimum pole arrangement can affect the energy dissipation capacity of the magneto-solid damper. The analysis results show that, for a given number and size of the permanent magnets, alternate arrangement of the poles of permanent magnets along the direction of their motion is the most optimal case resulting in large and smooth hysteresis force–displacement loops. This pole arrangement has also been used to find the optimum size of the steel and copper plates by addressing edge and skin effects in the design of the damper.
- 1 January 2020
- Published by American Society of Civil Engineers (ASCE) in Journal of Bridge Engineering
- Vol. 25 (1)
Experimental Evaluation of Unmanned Aerial System for Measuring Bridge Movement
Highway bridges are the key element of a transportation system and are essential for transportation of goods, services, and people. They are, however, vulnerable to extreme geologic and hydraulic events such as earthquakes, scour, and hurricanes. It is imperative to collect key perishable data during and after extreme hazard events for engineering evaluation and improving the current and future bridge design and maintenance practices. The objective of the posthazard damage assessment is to collect engineering data related to global structural behavior of different components of a highway bridge such as decks and piers. This paper studies the feasibility of using unmanned aerial systems (UASs) for posthazard damage assessment of highway bridges subjected to extreme geologic and hydraulic hazards through a mock-up test setup. For this purpose, a model bridge was developed to simulate movements of the key components of a highway bridge. Three types of structural movements in bridges have been studied: translation, rotation, and settlement. The results show the capability of the UAS and ground-based tripod assembly with high-resolution camera to detect these movements with high accuracy. The average absolute differences observed between the measured and estimated values were 0.7 cm (0.28 in.), 1 cm (0.39 in.), and 1.4 cm (0.55 in.) in the translation, rotation, and settlement movement experiments, respectively.
- 1 January 2020
- Published by American Society of Civil Engineers (ASCE) in Journal of Bridge Engineering
- Vol. 25 (1)
Experimental Evaluation of Unmanned Aerial System for Measuring Bridge Movement
Highway bridges are the key element of a transportation system and are essential for transportation of goods, services, and people. They are, however, vulnerable to extreme geologic and hydraulic events such as earthquakes, scour, and hurricanes. It is imperative to collect key perishable data during and after extreme hazard events for engineering evaluation and improving the current and future bridge design and maintenance practices. The objective of the posthazard damage assessment is to collect engineering data related to global structural behavior of different components of a highway bridge such as decks and piers. This paper studies the feasibility of using unmanned aerial systems (UASs) for posthazard damage assessment of highway bridges subjected to extreme geologic and hydraulic hazards through a mock-up test setup. For this purpose, a model bridge was developed to simulate movements of the key components of a highway bridge. Three types of structural movements in bridges have been studied: translation, rotation, and settlement. The results show the capability of the UAS and ground-based tripod assembly with high-resolution camera to detect these movements with high accuracy. The average absolute differences observed between the measured and estimated values were 0.7 cm (0.28 in.), 1 cm (0.39 in.), and 1.4 cm (0.55 in.) in the translation, rotation, and settlement movement experiments, respectively.
- 1 September 2019
- Published by Elsevier in Mechanical Systems and Signal Processing
- Vol. 130, 409-432
Seismic response control of multi-story base-isolated buildings using a smart electromagnetic friction damper with smooth hysteretic behavior
- 1 September 2019
- Published by Elsevier in Mechanical Systems and Signal Processing
- Vol. 130, 409-432
Seismic response control of multi-story base-isolated buildings using a smart electromagnetic friction damper with smooth hysteretic behavior
- 13 February 2019
- Published by Hindawi Limited in Structural Control and Health Monitoring
- Vol. 26 (4) , e2333
Feasibility study of using a semiactive electromagnetic friction damper for seismic response control of horizontally curved bridges
Semiactive control systems have been found to be more effective than passive and active control systems for seismic protection of bridges because of their reliable and adaptable characteristics. This paper presents a comprehensive investigation on the modeling and design of a semiactive electromagnetic friction damper (SEMFD) for the seismic response control of horizontally curved bridges. The proposed SEMFD possesses a simple configuration consisting of a ferromagnetic plate and two arrays of ferromagnetic core coils (FCs) attached to the two sides of the ferromagnetic plate through two friction pads. The attractive magnetic interaction between the FCs arrays and the ferromagnetic plate creates the normal force, which generates friction force as the friction pads and the ferromagnetic plate move relative to each other. The magnitude of this force can be controlled by varying the control current passing through the FCs. This semiactive controller, designed based on the optimal linear quadratic Gaussian control method, is capable of reducing the undesirable effects of stick–slip motion in the damper, while restoring the piston of the SEMFD to its initial position at the end of the excitation. The capability of the proposed SEMFD to mitigate the rigid‐body motion of decks of horizontally curved bridges is demonstrated by implementing it into the dynamic model of a horizontally curved bridge prototype. The numerical results indicate that the proposed SEMFD is effective in limiting the motion of the deck and thereby preventing it from unseating, which is one of the most common modes of failure among horizontally curved bridges.
- 13 February 2019
- Published by Hindawi Limited in Structural Control and Health Monitoring
- Vol. 26 (4) , e2333
Feasibility study of using a semiactive electromagnetic friction damper for seismic response control of horizontally curved bridges
Semiactive control systems have been found to be more effective than passive and active control systems for seismic protection of bridges because of their reliable and adaptable characteristics. This paper presents a comprehensive investigation on the modeling and design of a semiactive electromagnetic friction damper (SEMFD) for the seismic response control of horizontally curved bridges. The proposed SEMFD possesses a simple configuration consisting of a ferromagnetic plate and two arrays of ferromagnetic core coils (FCs) attached to the two sides of the ferromagnetic plate through two friction pads. The attractive magnetic interaction between the FCs arrays and the ferromagnetic plate creates the normal force, which generates friction force as the friction pads and the ferromagnetic plate move relative to each other. The magnitude of this force can be controlled by varying the control current passing through the FCs. This semiactive controller, designed based on the optimal linear quadratic Gaussian control method, is capable of reducing the undesirable effects of stick–slip motion in the damper, while restoring the piston of the SEMFD to its initial position at the end of the excitation. The capability of the proposed SEMFD to mitigate the rigid‐body motion of decks of horizontally curved bridges is demonstrated by implementing it into the dynamic model of a horizontally curved bridge prototype. The numerical results indicate that the proposed SEMFD is effective in limiting the motion of the deck and thereby preventing it from unseating, which is one of the most common modes of failure among horizontally curved bridges.