Sergejs Fomins
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Sergejs Fomins has a total of 55 co-authors. Here are the top co-authors by number of shared publications:
Maris Ozolinsh
Department of Optometry and Vision Science, Faculty of Physics and Mathematics, University of Latvia Riga, Latvia
7 shared publications- Gunta Krumina
University of Latvia
6 shared publications M. Ozolinsh
Institute of Solid State Physics (Latvia)
3 shared publications- Nikita Iroshnikov
Faculty of Physics, M.V.Lomonosov Moscow State University Leninskie Gory 119991 Moscow Russia
3 shared publications Varis Karitans
Institute of Solid State Physics, University of Latvia Riga, Latvia
3 shared publications- Aiga Svede
University of Latvia
2 shared publications
Latest Publications
- Open Access
The Effect of Stimulus Contrast and Spatial Position on Saccadic Eye Movement Parameters
(1) Background: Saccadic eye movements are rapid eye movements aimed to position the object image on the central retina, ensuring high-resolution data sampling across the visual field. Although saccadic eye movements are studied extensively, different experimental settings applied across different studies have left an open question of whether and how stimulus parameters can affect the saccadic performance. The current study aims to explore the effect of stimulus contrast and spatial position on saccadic eye movement latency, peak velocity and accuracy measurements. (2) Methods: Saccadic eye movement targets of different contrast levels were presented at four different spatial positions. The eye movements were recorded with a Tobii Pro Fusion video-oculograph (250 Hz). (3) Results: The results demonstrate a significant effect of stimulus spatial position on the latency and peak velocity measurements at a medium grey background, 30 cd/m2 (negative and positive stimulus polarity), light grey background, 90 cd/m2 (negative polarity), and black background, 3 cd/m2 (positive polarity). A significant effect of the stimulus spatial position was observed on the accuracy measurements when the saccadic eye movement stimuli were presented on a medium grey background (negative polarity) and on a black background. No significant effect of stimulus contrast was observed on the peak velocity measurements under all conditions. A significant stimulus contrast effect on latency and accuracy was observed only on a light grey background. (4) Conclusions: The best saccadic eye movement performance (lowest latency, highest peak velocity and accuracy measurements) can be observed when the saccades are oriented to the right and left from the central fixation point. Furthermore, when presenting the stimulus on a light grey background, a very low contrast stimuli should be considered carefully.
Open AccessThe Effect of Stimulus Contrast and Spatial Position on Saccadic Eye Movement Parameters
(1) Background: Saccadic eye movements are rapid eye movements aimed to position the object image on the central retina, ensuring high-resolution data sampling across the visual field. Although saccadic eye movements are studied extensively, different experimental settings applied across different studies have left an open question of whether and how stimulus parameters can affect the saccadic performance. The current study aims to explore the effect of stimulus contrast and spatial position on saccadic eye movement latency, peak velocity and accuracy measurements. (2) Methods: Saccadic eye movement targets of different contrast levels were presented at four different spatial positions. The eye movements were recorded with a Tobii Pro Fusion video-oculograph (250 Hz). (3) Results: The results demonstrate a significant effect of stimulus spatial position on the latency and peak velocity measurements at a medium grey background, 30 cd/m2 (negative and positive stimulus polarity), light grey background, 90 cd/m2 (negative polarity), and black background, 3 cd/m2 (positive polarity). A significant effect of the stimulus spatial position was observed on the accuracy measurements when the saccadic eye movement stimuli were presented on a medium grey background (negative polarity) and on a black background. No significant effect of stimulus contrast was observed on the peak velocity measurements under all conditions. A significant stimulus contrast effect on latency and accuracy was observed only on a light grey background. (4) Conclusions: The best saccadic eye movement performance (lowest latency, highest peak velocity and accuracy measurements) can be observed when the saccades are oriented to the right and left from the central fixation point. Furthermore, when presenting the stimulus on a light grey background, a very low contrast stimuli should be considered carefully.
- Open Access
- 30 March 2020
- Published by Optica Publishing Group in Journal of the Optical Society of America A
- Vol. 37 (4) , CV1-CV2
Color Vision 2020: Introduction by the feature editors
- 30 March 2020
- Published by Optica Publishing Group in Journal of the Optical Society of America A
- Vol. 37 (4) , CV1-CV2
Open AccessColor Vision 2020: Introduction by the feature editors
- Open Access
- 1 January 2020
- Published by University of Latvia
LU FMOF optometrijas un redzes zinātnes nodaļas un Latvijas optometristu un optiķu asociācijas konferenču referātu tēzes
- 1 January 2020
- Published by University of Latvia
Open AccessLU FMOF optometrijas un redzes zinātnes nodaļas un Latvijas optometristu un optiķu asociācijas konferenču referātu tēzes
- 25 April 2015
- Published by Springer Nature in Annals of Dyslexia
- Vol. 65 (2) , 69-83
Reading and coherent motion perception in school age children
This study includes an evaluation, according to age, of the reading and global motion perception developmental trajectories of 2027 school age children in typical stages of development. Reading is assessed using the reading rate score test, for which all of the student participants, regardless of age, received the same passage of text of a medium difficulty reading level. The coherent motion perception threshold is determined according to the adaptive psychophysical protocol based on a four-alternative, forced-choice procedure. Three different dot velocities: 2, 5, and 8 deg/s were used for both assemblies of coherent or randomly moving dots. Reading rate score test results exhibit a wide dispersion across all age groups, so much so that the outlier data overlap, for both the 8 and 18-year-old student-participant age groups. Latvian children’s reading fluency developmental trajectories reach maturation at 12–13 years of age. After the age of 13, reading rate scores increase slowly; however, the linear regression slope is different from zero and positive: F(1, 827) = 45.3; p < 0.0001. One hundred eighty-one student-participants having results below the 10th percentile were classified as weak readers in our study group. The reading fluency developmental trajectory of this particular group of student-participants does not exhibit any statistically significant saturation until the age of 18 years old. Coherent motion detection thresholds decrease with age and do not reach saturation. Tests with slower moving dots (2 deg/s) yield results that exhibit significant differences between strong and weak readers.
- 25 April 2015
- Published by Springer Nature in Annals of Dyslexia
- Vol. 65 (2) , 69-83
Reading and coherent motion perception in school age children
This study includes an evaluation, according to age, of the reading and global motion perception developmental trajectories of 2027 school age children in typical stages of development. Reading is assessed using the reading rate score test, for which all of the student participants, regardless of age, received the same passage of text of a medium difficulty reading level. The coherent motion perception threshold is determined according to the adaptive psychophysical protocol based on a four-alternative, forced-choice procedure. Three different dot velocities: 2, 5, and 8 deg/s were used for both assemblies of coherent or randomly moving dots. Reading rate score test results exhibit a wide dispersion across all age groups, so much so that the outlier data overlap, for both the 8 and 18-year-old student-participant age groups. Latvian children’s reading fluency developmental trajectories reach maturation at 12–13 years of age. After the age of 13, reading rate scores increase slowly; however, the linear regression slope is different from zero and positive: F(1, 827) = 45.3; p < 0.0001. One hundred eighty-one student-participants having results below the 10th percentile were classified as weak readers in our study group. The reading fluency developmental trajectory of this particular group of student-participants does not exhibit any statistically significant saturation until the age of 18 years old. Coherent motion detection thresholds decrease with age and do not reach saturation. Tests with slower moving dots (2 deg/s) yield results that exhibit significant differences between strong and weak readers.
- Open Access
- 27 November 2014
- Published by Frontiers Media SA in Frontiers in Psychology
- Vol. 5, 1376
Color-discrimination threshold determination using pseudoisochromatic test plates
We produced a set of pseudoisochromatic plates for determining individual color-difference thresholds to assess test performance and test properties, and analyzed the results. We report a high test validity and classification ability for the deficiency type and severity level (comparable to that of the fourth edition of the Hardy–Rand–Rittler (HRR) test). We discuss changes of the acceptable chromatic shifts from the protan and deutan confusion lines along the CIE xy diagram, and the high correlation of individual color-difference thresholds and the red–green discrimination index. Color vision was tested using an Oculus HMC anomaloscope, a Farnsworth D15, and an HRR test on 273 schoolchildren, and 57 other subjects with previously diagnosed red–green color-vision deficiency.
- 27 November 2014
- Published by Frontiers Media SA in Frontiers in Psychology
- Vol. 5, 1376
Open AccessColor-discrimination threshold determination using pseudoisochromatic test plates
We produced a set of pseudoisochromatic plates for determining individual color-difference thresholds to assess test performance and test properties, and analyzed the results. We report a high test validity and classification ability for the deficiency type and severity level (comparable to that of the fourth edition of the Hardy–Rand–Rittler (HRR) test). We discuss changes of the acceptable chromatic shifts from the protan and deutan confusion lines along the CIE xy diagram, and the high correlation of individual color-difference thresholds and the red–green discrimination index. Color vision was tested using an Oculus HMC anomaloscope, a Farnsworth D15, and an HRR test on 273 schoolchildren, and 57 other subjects with previously diagnosed red–green color-vision deficiency.
- 22 October 2014
- Published by SPIE-Intl Soc Optical Eng
- Vol. 9421, 94210N-94210N-6
Algorithms for skiascopy measurement automatization
- 22 October 2014
- Published by SPIE-Intl Soc Optical Eng
- Vol. 9421, 94210N-94210N-6
Algorithms for skiascopy measurement automatization
- Open Access
- 13 December 2013
- Published by IOP Publishing in IOP Conference Series: Materials Science and Engineering
- Vol. 49 (1) , 012041
Multispectral analysis and cone signal modelling of pseudoisochromatic test plates
The aim of the study is to determine the consistency of the desired colour reproduction of the stimuli using calibrated printing technology available to anyone (EpsonStylus Pro 7800 printer was). 24 colour vision assessment plates created in the University of Latvia were analysed right after their fabrication on august 2012 and after intense use for 7 months (colour vision screening on 700 people). Multispectral imagery results indicate that the alignment of the samples after seven months of use has maintained on the CIExy confusion lines of deutan deficiency type, but the shift towards achromatic area in the diagram indicate decrease in the total colour difference (ΔE*ab) of test background (achromatic) areas and stimuli (chromatic) areas, thus affecting the testing outcome and deficiency severity level classification ability of the plates.
- 13 December 2013
- Published by IOP Publishing in IOP Conference Series: Materials Science and Engineering
- Vol. 49 (1) , 012041
Open AccessMultispectral analysis and cone signal modelling of pseudoisochromatic test plates
The aim of the study is to determine the consistency of the desired colour reproduction of the stimuli using calibrated printing technology available to anyone (EpsonStylus Pro 7800 printer was). 24 colour vision assessment plates created in the University of Latvia were analysed right after their fabrication on august 2012 and after intense use for 7 months (colour vision screening on 700 people). Multispectral imagery results indicate that the alignment of the samples after seven months of use has maintained on the CIExy confusion lines of deutan deficiency type, but the shift towards achromatic area in the diagram indicate decrease in the total colour difference (ΔE*ab) of test background (achromatic) areas and stimuli (chromatic) areas, thus affecting the testing outcome and deficiency severity level classification ability of the plates.
- 18 November 2013
- Published by SPIE-Intl Soc Optical Eng
- Vol. 9032, 903205-903205-4
Modelling the appearance of chromatic environment using hyperspectral imaging
- 18 November 2013
- Published by SPIE-Intl Soc Optical Eng
- Vol. 9032, 903205-903205-4
Modelling the appearance of chromatic environment using hyperspectral imaging
- 20 August 2012
- Published by IOP Publishing in IOP Conference Series: Materials Science and Engineering
- Vol. 38
Pseudoisochromatic test plate colour representation dependence on printing technology
- 20 August 2012
- Published by IOP Publishing in IOP Conference Series: Materials Science and Engineering
- Vol. 38
Pseudoisochromatic test plate colour representation dependence on printing technology
- Open Access
- 20 June 2012
- Published by Kaunas University of Technology (KTU) in Materials Science
- Vol. 18 (2) , 202-205
Rayleigh Equation Anomaloscope from Commercially Available LEDs
Most precise classification of CVD (color vision deficits) can be provided by using anomaloscope. Today anomaloscopes are available, which can evaluate red-green (Rayleigh) and blue-green (Moreland) color defects.DOI: http://dx.doi.org/10.5755/j01.ms.18.2.1928
- 20 June 2012
- Published by Kaunas University of Technology (KTU) in Materials Science
- Vol. 18 (2) , 202-205
Open AccessRayleigh Equation Anomaloscope from Commercially Available LEDs
Most precise classification of CVD (color vision deficits) can be provided by using anomaloscope. Today anomaloscopes are available, which can evaluate red-green (Rayleigh) and blue-green (Moreland) color defects.DOI: http://dx.doi.org/10.5755/j01.ms.18.2.1928