Hayley Wyatt
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Hayley Wyatt has a total of 15 co-authors. Here are the top co-authors by number of shared publications:
- L. Angela Mihai
School of Mathematics, Cardiff University, Cardiff, UK
2 shared publications - Sam L. Evans
School of Engineering Cardiff University Cardiff UK
2 shared publications Alastair Clarke
School of Engineering, Cardiff University, The Parade, Cardiff CF24 3AA, UK
1 shared publicationAlexander Safar
School of Mathematics, Cardiff University, Senghennydd Road, Cardiff CF24 4AG, UK
1 shared publication- Danielle Fitt
Cardiff University
1 shared publication Emma J Blain
Cardiff School of Biosciences, Cardiff University, Cardiff, UK
1 shared publication
Latest Publications
- Open Access
- 24 November 2022
- Published by Taylor & Francis in Computer Methods in Biomechanics and Biomedical Engineering
- Vol. 26 (14) , 1719-1731
An analysis of the relationship between microneedle spacing, needle force and skin strain during the indentation phase prior to skin penetration
Microneedle (MN) array patches present a promising new approach for the minimally invasive delivery of therapeutics and vaccines. However, ensuring reproducible insertion of MNs into the skin is challenging. The spacing and arrangement of MNs in an array are critical determinants of skin penetration and the mechanical integrity of the MNs. In this work, the finite element method was used to model the effect of MN spacing on needle reaction force and skin strain during the indentation phase prior to skin penetration. Spacings smaller than 2–3 mm (depending on variables, e.g., skin stretch) were found to significantly increase these parameters.
- 24 November 2022
- Published by Taylor & Francis in Computer Methods in Biomechanics and Biomedical Engineering
- Vol. 26 (14) , 1719-1731
Open AccessAn analysis of the relationship between microneedle spacing, needle force and skin strain during the indentation phase prior to skin penetration
Microneedle (MN) array patches present a promising new approach for the minimally invasive delivery of therapeutics and vaccines. However, ensuring reproducible insertion of MNs into the skin is challenging. The spacing and arrangement of MNs in an array are critical determinants of skin penetration and the mechanical integrity of the MNs. In this work, the finite element method was used to model the effect of MN spacing on needle reaction force and skin strain during the indentation phase prior to skin penetration. Spacings smaller than 2–3 mm (depending on variables, e.g., skin stretch) were found to significantly increase these parameters.
- Open Access
- 23 November 2019
- Published by Springer Nature in Mechanics of Soft Materials
- Vol. 1 (1) , 13
Uncertainty quantification of elastic material responses: testing, stochastic calibration and Bayesian model selection
Motivated by the need to quantify uncertainties in the mechanical behaviour of solid materials, we perform simple uniaxial tensile tests on a manufactured rubber-like material that provide critical information regarding the variability in the constitutive responses between different specimens. Based on the experimental data, we construct stochastic homogeneous hyperelastic models where the parameters are described by spatially independent probability density functions at a macroscopic level. As more than one parametrised model is capable of capturing the observed material behaviour, we apply Baye theorem to select the model that is most likely to reproduce the data. Our analysis is fully tractable mathematically and builds directly on knowledge from deterministic finite elasticity. The proposed stochastic calibration and Bayesian model selection are generally applicable to more complex tests and materials.
- 23 November 2019
- Published by Springer Nature in Mechanics of Soft Materials
- Vol. 1 (1) , 13
Open AccessUncertainty quantification of elastic material responses: testing, stochastic calibration and Bayesian model selection
Motivated by the need to quantify uncertainties in the mechanical behaviour of solid materials, we perform simple uniaxial tensile tests on a manufactured rubber-like material that provide critical information regarding the variability in the constitutive responses between different specimens. Based on the experimental data, we construct stochastic homogeneous hyperelastic models where the parameters are described by spatially independent probability density functions at a macroscopic level. As more than one parametrised model is capable of capturing the observed material behaviour, we apply Baye theorem to select the model that is most likely to reproduce the data. Our analysis is fully tractable mathematically and builds directly on knowledge from deterministic finite elasticity. The proposed stochastic calibration and Bayesian model selection are generally applicable to more complex tests and materials.
- Open Access
- 16 January 2019
- Published by The Royal Society in Royal Society Open Science
- Vol. 6 (1) , 181361
Nonlinear scaling effects in the stiffness of soft cellular structures
For cellular structures with uniform geometry, cell size and distribution, made from a neo-Hookean material, we demonstrate experimentally that large stretching causes nonlinear scaling effects governed by the microstructural architecture and the large strains at the cell level, which are not predicted by the linear elastic theory. For this purpose, three honeycomb-like structures with uniform square cells in stacked distribution were designed, where the number of cells varied, while the material volume and the ratio between the thickness and the length of the cell walls were fixed. These structures were manufactured from silicone rubber and tested under large uniaxial tension in a bespoke test fixture. Optical strain measurements were used to assess the deformation by capturing both the global displacements of the structure and the local deformations in the form of a strain map. The experimental results showed that, under sufficiently large strains, there was an increase in the stiffness of the structure when the same volume of material was arranged as many small cells compared to when it was organized as fewer larger cells. Finite element simulations confirmed our experimental findings. This study sheds light upon the nonlinear elastic responses of cellular structures in large-strain deformations, which cannot be captured within the linear elasticity framework.
- 16 January 2019
- Published by The Royal Society in Royal Society Open Science
- Vol. 6 (1) , 181361
Open AccessNonlinear scaling effects in the stiffness of soft cellular structures
For cellular structures with uniform geometry, cell size and distribution, made from a neo-Hookean material, we demonstrate experimentally that large stretching causes nonlinear scaling effects governed by the microstructural architecture and the large strains at the cell level, which are not predicted by the linear elastic theory. For this purpose, three honeycomb-like structures with uniform square cells in stacked distribution were designed, where the number of cells varied, while the material volume and the ratio between the thickness and the length of the cell walls were fixed. These structures were manufactured from silicone rubber and tested under large uniaxial tension in a bespoke test fixture. Optical strain measurements were used to assess the deformation by capturing both the global displacements of the structure and the local deformations in the form of a strain map. The experimental results showed that, under sufficiently large strains, there was an increase in the stiffness of the structure when the same volume of material was arranged as many small cells compared to when it was organized as fewer larger cells. Finite element simulations confirmed our experimental findings. This study sheds light upon the nonlinear elastic responses of cellular structures in large-strain deformations, which cannot be captured within the linear elasticity framework.
- Open Access
- 7 January 2016
- Published by SAGE Publications in Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine
- Vol. 230 (3) , 169-174
Variation in electrosurgical vessel seal quality along the length of a porcine carotid artery
Electrosurgical vessel sealing has been demonstrated to have benefits for both patients and practitioners, but significant variation in the strength of the seal continues to be a concern. This study aims to examine the variation in electrosurgical seal quality along the length of a porcine common carotid artery and explore the relationships between seal quality, vessel size and morphology. Additionally, the study aimed to investigate the minimum safety threshold for successful seals and the influence of vessel characteristics on meeting this requirement. A total of 35 porcine carotid arteries were sealed using the PlasmaKinetic Open Seal device (Gyrus). Each seal was burst pressure tested and a sample taken for staining with elastin van Gieson’s stain, with morphological quantification using image processing software ImageJ. With increasing distance from the bifurcation, there was an increase in seal strength and a reduction in both elastin content and vessel outer diameter. A significant correlation was found between burst pressure with both outer diameter (p < 0.0001) and elastin content (p = 0.001). When considering the safe limits of operation, vessels of less than 5 mm in outer diameter were shown to consistently produce a seal of a sufficient strength (burst pressure > 360 mmHg) irrespective of vessel morphology.
- 7 January 2016
- Published by SAGE Publications in Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine
- Vol. 230 (3) , 169-174
Open AccessVariation in electrosurgical vessel seal quality along the length of a porcine carotid artery
Electrosurgical vessel sealing has been demonstrated to have benefits for both patients and practitioners, but significant variation in the strength of the seal continues to be a concern. This study aims to examine the variation in electrosurgical seal quality along the length of a porcine common carotid artery and explore the relationships between seal quality, vessel size and morphology. Additionally, the study aimed to investigate the minimum safety threshold for successful seals and the influence of vessel characteristics on meeting this requirement. A total of 35 porcine carotid arteries were sealed using the PlasmaKinetic Open Seal device (Gyrus). Each seal was burst pressure tested and a sample taken for staining with elastin van Gieson’s stain, with morphological quantification using image processing software ImageJ. With increasing distance from the bifurcation, there was an increase in seal strength and a reduction in both elastin content and vessel outer diameter. A significant correlation was found between burst pressure with both outer diameter (p < 0.0001) and elastin content (p = 0.001). When considering the safe limits of operation, vessels of less than 5 mm in outer diameter were shown to consistently produce a seal of a sufficient strength (burst pressure > 360 mmHg) irrespective of vessel morphology.