Jian-Xin Chu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Jian-Xin Chu has a total of 34 co-authors. Here are the top co-authors by number of shared publications:
Shun-Li Ding
3 shared publications- Wangqiang Niu
Key Laboratory of Transport Industry of Marine Technology and Control Engineering, Shanghai Maritime University, Shanghai 201306, China
3 shared publications - Xiang-Wei Cheng
Zhejiang Police College, Hangzhou 310053, China
3 shared publications Ai-Di Shen
Shanghai Maritime University
2 shared publicationsJun-Ming Zhao
2 shared publicationsShu-Ping Wang
2 shared publications
Latest Publications
- 1 December 2013
- Vol. 29 (6) , 451-3
[Progress on suxamethonium chloride analysis].
Suxamethonium chloride is a depolarizing muscle relaxant used in general anesthesia. In overdose, it causes adverse reactions such as bradycardia, arrhythmia, cardiac arrest, and death. The article reviews the progress on testing methods of suxamethonium chloride such as infrared spectroscopy, chemical color reaction, chemical titration, enzyme electrode, chromatography and mass spectrometry.
- 1 December 2013
- Vol. 29 (6) , 451-3
[Progress on suxamethonium chloride analysis].
Suxamethonium chloride is a depolarizing muscle relaxant used in general anesthesia. In overdose, it causes adverse reactions such as bradycardia, arrhythmia, cardiac arrest, and death. The article reviews the progress on testing methods of suxamethonium chloride such as infrared spectroscopy, chemical color reaction, chemical titration, enzyme electrode, chromatography and mass spectrometry.
- 11 April 2013
- Published by Springer Nature in China Ocean Engineering
- Vol. 27 (2) , 255-263
Research on propeller dynamic load simulation system of electric propulsion ship
- 11 April 2013
- Published by Springer Nature in China Ocean Engineering
- Vol. 27 (2) , 255-263
Research on propeller dynamic load simulation system of electric propulsion ship
- 1 April 2013
- Vol. 29 (2) , 122-4
[A retrospective analysis of 97 drunk driving cases].
Based on a retrospective analysis of the drunk driving cases, to explore the drunk drivers' personnel composition, occurrence time and psychology. As a result of punishment of the drunk driving by criminal law for one year from May 1st, 2011 to April 30th, 2012, 91 drunk driving cases were statistically analyzed the easy-happening time of drunk driving, the drunk drivers' age, gender, occupational characteristics, domicile and psychological factors. In 97 drunk driving cases, 26-40 years old, non-local domiciled and non-professional male drivers were prone to drunk driving at night from 22:00 to 5:00. The behavior of drunk driving is relevant to time, age, genders and occupation. The psychological characteristics of most drivers are fluky, making-life-easy, competitive and peacockish.
- 1 April 2013
- Vol. 29 (2) , 122-4
[A retrospective analysis of 97 drunk driving cases].
Based on a retrospective analysis of the drunk driving cases, to explore the drunk drivers' personnel composition, occurrence time and psychology. As a result of punishment of the drunk driving by criminal law for one year from May 1st, 2011 to April 30th, 2012, 91 drunk driving cases were statistically analyzed the easy-happening time of drunk driving, the drunk drivers' age, gender, occupational characteristics, domicile and psychological factors. In 97 drunk driving cases, 26-40 years old, non-local domiciled and non-professional male drivers were prone to drunk driving at night from 22:00 to 5:00. The behavior of drunk driving is relevant to time, age, genders and occupation. The psychological characteristics of most drivers are fluky, making-life-easy, competitive and peacockish.
- 29 November 2012
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Circuits and Systems I: Regular Papers
- Vol. 60 (6) , 1670-1677
Exact Analysis of Frequency Splitting Phenomena of Contactless Power Transfer Systems
Frequency splitting phenomena are investigated systematically by circuit theory in a series-tuned contactless power transfer (CPT) system. First, in a symmetrical CPT system, the splitting equation is defined and the key frequency splitting characteristics are described by the trough and the ridge equations in a complete fashion. The even and the odd splitting frequencies are exactly two roots of the ridge equation; the splitting coupling is determined theoretically when the even and odd splitting frequencies merge together. Second, in an unsymmetrical CPT system, the idea of the trough and the ridge equation is exploited to find exactly the splitting coupling. Next, the relationship between frequency bifurcation and splitting is elucidated; and a zero-phase control method is suggested to track the splitting frequency when the coupling changes in the splitting region. Finally, the theoretical results are validated by a 10-W prototype with planar spiral coils.
- 29 November 2012
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Circuits and Systems I: Regular Papers
- Vol. 60 (6) , 1670-1677
Exact Analysis of Frequency Splitting Phenomena of Contactless Power Transfer Systems
Frequency splitting phenomena are investigated systematically by circuit theory in a series-tuned contactless power transfer (CPT) system. First, in a symmetrical CPT system, the splitting equation is defined and the key frequency splitting characteristics are described by the trough and the ridge equations in a complete fashion. The even and the odd splitting frequencies are exactly two roots of the ridge equation; the splitting coupling is determined theoretically when the even and odd splitting frequencies merge together. Second, in an unsymmetrical CPT system, the idea of the trough and the ridge equation is exploited to find exactly the splitting coupling. Next, the relationship between frequency bifurcation and splitting is elucidated; and a zero-phase control method is suggested to track the splitting frequency when the coupling changes in the splitting region. Finally, the theoretical results are validated by a 10-W prototype with planar spiral coils.
- 7 June 2012
- Published by Institution of Engineering and Technology (IET) in Electronics Letters
- Vol. 48 (12) , 723-724
Coupled-mode analysis of frequency splitting phenomena in CPT systems
An asymptotic coupled-mode theory (CMT) method is used to analyse the frequency splitting phenomena in contactless power transfer (CPT) systems. Theoretical analysis and experimental results show that the CMT method catches the key pitchfork characteristics of the frequency splitting phenomena, and a concise expression is derived to relate the splitting point to all key system parameters.
- 7 June 2012
- Published by Institution of Engineering and Technology (IET) in Electronics Letters
- Vol. 48 (12) , 723-724
Coupled-mode analysis of frequency splitting phenomena in CPT systems
An asymptotic coupled-mode theory (CMT) method is used to analyse the frequency splitting phenomena in contactless power transfer (CPT) systems. Theoretical analysis and experimental results show that the CMT method catches the key pitchfork characteristics of the frequency splitting phenomena, and a concise expression is derived to relate the splitting point to all key system parameters.
- 1 February 2010
- Vol. 26 (1) , 56-8, 63
[Micellar liquid chromatography and its application in toxicological analysis].
Micellar liquid chromatography (MLC) is a reversed phase liquid chromatography with mobile phases containing surfactant above its critical micellar concentration (CMC). The basic mechanism and advantages of MLC in physicochemical analysis were reviewed, and its applications in analysis of drugs, barbiturates, benzodiazepines were chiefly introduced in this paper. MLC is a potential method to toxicological analysis due to strong selectivity, wide application scope and easy biological samples, etc.
- 1 February 2010
- Vol. 26 (1) , 56-8, 63
[Micellar liquid chromatography and its application in toxicological analysis].
Micellar liquid chromatography (MLC) is a reversed phase liquid chromatography with mobile phases containing surfactant above its critical micellar concentration (CMC). The basic mechanism and advantages of MLC in physicochemical analysis were reviewed, and its applications in analysis of drugs, barbiturates, benzodiazepines were chiefly introduced in this paper. MLC is a potential method to toxicological analysis due to strong selectivity, wide application scope and easy biological samples, etc.
- 1 December 2009
- Vol. 32 (12) , 902-7
[The effect of autologous bone marrow-derived cells mobilized by granulocyte colony stimulating factor on bleomycin-induced lung injury in mice.].
To investigate the contribution of mobilized autologous bone marrow-derived cells (BMDC) to lung repair after lung injury induced by bleomycin, and the mechanisms of any protective effects conferred by BMDC. Sixty marrow-reconstructed mice were randomly divided into 2 groups: group A [bleomycin + granulocyte colony stimulating factor (G-CSF)] and group B (bleomycin + saline). Seventy-five normal mice were randomly divided into 3 groups: group C (bleomycin + G-CSF); group D (bleomycin + saline) and group N (saline only). Each group was further divided into 3 subgroups, which were sacrificed respectively on days 3, 7 and 14. Therapeutic evaluations were made by means of HE stain, Masson's trichrome stain, hydroxyproline concentration and pulmonary permeability index. The expressions of TGF-beta(1), IFN-gamma, MMP-9 and TIMP-1 in the lung tissue were detected by immunohistochemistry. Intrapulmonary BMDC was evaluated by flow cytometry and laser scanning confocal microscope. Another 20 mice were randomly divided into 2 groups including group E (bleomycin + G-CSF) and group F (bleomycin + saline). The survival time of each mouse was observed without end point. The alveolitis score (mean rank 15.3), the pulmonary fibrosis score (46 +/- 8), the hydroxyproline concentrations (0.44 +/- 0.09) microg/mg, the TGF-beta(1) level (111 +/- 23), the IFN-gamma level (250 +/- 72) and the MMP-9 level (59 +/- 19) were significantly decreased in reconstructed treatment group on day 7 as compared to reconstructed control group, which was respectively (mean rank 28.0), (73 +/- 10), (0.52 +/- 0.07) microg/mg, (161 +/- 35), (299 +/- 31) and (314 +/- 77). Likewise, the alveolitis (mean rank 22.7), the pulmonary fibrosis (27 +/- 15), the hydroxyproline concentrations (0.41 +/- 0.05) microg/mg, the pulmonary permeability index (43.8 +/- 9.9) x 10(-3), the TGF-beta(1) level (132 +/- 55), the IFN-gamma level (178 +/- 23), and the MMP-9 level (101 +/- 54) in non-reconstructed treatment group on day 7 were significantly lower than those in non-reconstructed control group, (mean rank 33.9), (56 +/- 13), (0.49 +/- 0.08) microg/mg, (54 +/- 9) x 10(-3), (320 +/- 98), (409 +/- 61), (288 +/- 75), the differences being statistically significant (P < 0.05). The intrapulmonary BMDC level of reconstructed treatment group (0.65 +/- 0.13) was significantly higher than that in reconstructed control group (0.46 +/- 0.11), P < 0.05. Mobilization of BMDC by G-CSF showed a protective effect on lung injury induced by bleomycin in mice, but did not have significant influence on survival time.
- 1 December 2009
- Vol. 32 (12) , 902-7
[The effect of autologous bone marrow-derived cells mobilized by granulocyte colony stimulating factor on bleomycin-induced lung injury in mice.].
To investigate the contribution of mobilized autologous bone marrow-derived cells (BMDC) to lung repair after lung injury induced by bleomycin, and the mechanisms of any protective effects conferred by BMDC. Sixty marrow-reconstructed mice were randomly divided into 2 groups: group A [bleomycin + granulocyte colony stimulating factor (G-CSF)] and group B (bleomycin + saline). Seventy-five normal mice were randomly divided into 3 groups: group C (bleomycin + G-CSF); group D (bleomycin + saline) and group N (saline only). Each group was further divided into 3 subgroups, which were sacrificed respectively on days 3, 7 and 14. Therapeutic evaluations were made by means of HE stain, Masson's trichrome stain, hydroxyproline concentration and pulmonary permeability index. The expressions of TGF-beta(1), IFN-gamma, MMP-9 and TIMP-1 in the lung tissue were detected by immunohistochemistry. Intrapulmonary BMDC was evaluated by flow cytometry and laser scanning confocal microscope. Another 20 mice were randomly divided into 2 groups including group E (bleomycin + G-CSF) and group F (bleomycin + saline). The survival time of each mouse was observed without end point. The alveolitis score (mean rank 15.3), the pulmonary fibrosis score (46 +/- 8), the hydroxyproline concentrations (0.44 +/- 0.09) microg/mg, the TGF-beta(1) level (111 +/- 23), the IFN-gamma level (250 +/- 72) and the MMP-9 level (59 +/- 19) were significantly decreased in reconstructed treatment group on day 7 as compared to reconstructed control group, which was respectively (mean rank 28.0), (73 +/- 10), (0.52 +/- 0.07) microg/mg, (161 +/- 35), (299 +/- 31) and (314 +/- 77). Likewise, the alveolitis (mean rank 22.7), the pulmonary fibrosis (27 +/- 15), the hydroxyproline concentrations (0.41 +/- 0.05) microg/mg, the pulmonary permeability index (43.8 +/- 9.9) x 10(-3), the TGF-beta(1) level (132 +/- 55), the IFN-gamma level (178 +/- 23), and the MMP-9 level (101 +/- 54) in non-reconstructed treatment group on day 7 were significantly lower than those in non-reconstructed control group, (mean rank 33.9), (56 +/- 13), (0.49 +/- 0.08) microg/mg, (54 +/- 9) x 10(-3), (320 +/- 98), (409 +/- 61), (288 +/- 75), the differences being statistically significant (P < 0.05). The intrapulmonary BMDC level of reconstructed treatment group (0.65 +/- 0.13) was significantly higher than that in reconstructed control group (0.46 +/- 0.11), P < 0.05. Mobilization of BMDC by G-CSF showed a protective effect on lung injury induced by bleomycin in mice, but did not have significant influence on survival time.
- 1 June 2009
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 481-484
Estimation of the maintenance cycle from small sample based on a local fault interval model
Maintenance cycle is an important factor of a repairable system, and it is closely related to the safety operation and the level of energy consumption of the system. Two methods are presented to estimate the maintenance cycle from small sample based on a local fault interval model, one is the multi-point statistics method, and the other is the difference of sigmoidals method. Both methods are tested by real sample data from a portal crane. It is found that both methods are able to estimate the maintenance cycle of a repairable system. Furthermore, these two methods have a smaller probability to invoke the false positive problem than the three-point statistics method, while the difference of sigmoidals method is more robust than the multi-point statistics method.
- 1 June 2009
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 481-484
Estimation of the maintenance cycle from small sample based on a local fault interval model
Maintenance cycle is an important factor of a repairable system, and it is closely related to the safety operation and the level of energy consumption of the system. Two methods are presented to estimate the maintenance cycle from small sample based on a local fault interval model, one is the multi-point statistics method, and the other is the difference of sigmoidals method. Both methods are tested by real sample data from a portal crane. It is found that both methods are able to estimate the maintenance cycle of a repairable system. Furthermore, these two methods have a smaller probability to invoke the false positive problem than the three-point statistics method, while the difference of sigmoidals method is more robust than the multi-point statistics method.
- 1 January 2008
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-3
Study on wireless data transmission of an autonomous water vehicle for ocean observation
In this paper, a wireless data transmission system used in unmanned surface vehicles is presented. To improve reliability, wireless local network based on IP is employed. Through interface protocol, multi-modal data from different observation instruments or equipments are converted into the uniform specification suitable for transmission. Different control methods of data transmission are discussed. Experiment results from a unmanned surface vehicle sailing in the Yangtze River estuary show that the wireless data transmission system is suitable for applicable use.
- 1 January 2008
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-3
Study on wireless data transmission of an autonomous water vehicle for ocean observation
In this paper, a wireless data transmission system used in unmanned surface vehicles is presented. To improve reliability, wireless local network based on IP is employed. Through interface protocol, multi-modal data from different observation instruments or equipments are converted into the uniform specification suitable for transmission. Different control methods of data transmission are discussed. Experiment results from a unmanned surface vehicle sailing in the Yangtze River estuary show that the wireless data transmission system is suitable for applicable use.
- 15 August 2006
- Vol. 22 (4) , 285-7
[Determination of scopolamine in the poisoning case by GC/MS].
To separate and determine scopolamine from the food in a poisoning case by GC/MS. The scopolamine was determined by GC/MS/El used CP5860(CP-sil8CB) column (30 mx 0.25 mmx 0.33 microm) with liquid- liquid extraction. The deny scopolamine was found in the case sample, and the chromatographic separation of the peaks is fine. The method is accurate and reliable.
- 15 August 2006
- Vol. 22 (4) , 285-7
[Determination of scopolamine in the poisoning case by GC/MS].
To separate and determine scopolamine from the food in a poisoning case by GC/MS. The scopolamine was determined by GC/MS/El used CP5860(CP-sil8CB) column (30 mx 0.25 mmx 0.33 microm) with liquid- liquid extraction. The deny scopolamine was found in the case sample, and the chromatographic separation of the peaks is fine. The method is accurate and reliable.