Young-Mi Moon
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Young-Mi Moon has a total of 24 co-authors. Here are the top co-authors by number of shared publications:
- Min-Seock Seo
Department of Conservative Dentistry, Wonkang University Daejeon Dental Hospital, Daejeon, Republic of Korea
5 shared publications Seung-Ho Baek
Department of Conservative Dentistry, School of Dentistry, Dental Research Institute, Seoul National University, Seoul, Korea
4 shared publicationsWooCheol Lee
Department of Conservative Dentistry, School of Dentistry, Seoul National University, Dental Research Institute, Seoul, Korea
4 shared publicationsHyeon-Cheol Kim
Department of Conservative Dentistry, School of Dentistry, Pusan National University, Dental Research Institute, Pusan National University Dental Hospital, Yangsan, Korea
3 shared publicationsWon-Jun Shon
Department of Conservative Dentistry, School of Dentistry, Dental Research Institute, Seoul National University, Seoul, Korea
3 shared publicationsKee-Yeon Kum
Department of Conservative Dentistry, School of Dentistry, Dental Research Institute, Seoul National University, Seoul, Korea
2 shared publications
Latest Publications
- Open Access
- 1 January 2018
- Published by Korean Academy of Conservative Dentistry in Restorative Dentistry & Endodontics
- Vol. 43 (1) , e8
Corrigendum: Corrections to the funding. Quantification of the tug-back by measuring the pulling force and micro computed tomographic evaluation
Jeon SJ, et al. Restor Dent Endod. 2017 Dec;43:e8. https://doi.org/10.5395/rde.2018.43.e8
- 1 January 2018
- Published by Korean Academy of Conservative Dentistry in Restorative Dentistry & Endodontics
- Vol. 43 (1) , e8
Open AccessCorrigendum: Corrections to the funding. Quantification of the tug-back by measuring the pulling force and micro computed tomographic evaluation
Jeon SJ, et al. Restor Dent Endod. 2017 Dec;43:e8. https://doi.org/10.5395/rde.2018.43.e8
- Open Access
- 1 January 2018
- Published by Korean Academy of Conservative Dentistry in Restorative Dentistry & Endodontics
- Vol. 43 (1) , e3
Root canal volume change and transportation by Vortex Blue, ProTaper Next, and ProTaper Universal in curved root canals
Park HJ, et al. Restor Dent Endod. 2017 Dec;43:e3. https://doi.org/10.5395/rde.2018.43.e3
- 1 January 2018
- Published by Korean Academy of Conservative Dentistry in Restorative Dentistry & Endodontics
- Vol. 43 (1) , e3
Open AccessRoot canal volume change and transportation by Vortex Blue, ProTaper Next, and ProTaper Universal in curved root canals
Park HJ, et al. Restor Dent Endod. 2017 Dec;43:e3. https://doi.org/10.5395/rde.2018.43.e3
- Open Access
- 1 January 2017
- Published by Korean Academy of Conservative Dentistry in Restorative Dentistry & Endodontics
- Vol. 42 (4) , 273-281
Quantification of the tug-back by measuring the pulling force and micro computed tomographic evaluation
Jeon SJ, et al. Restor Dent Endod. 2017 Nov;42(4):273-281. https://doi.org/10.5395/rde.2017.42.4.273
- 1 January 2017
- Published by Korean Academy of Conservative Dentistry in Restorative Dentistry & Endodontics
- Vol. 42 (4) , 273-281
Open AccessQuantification of the tug-back by measuring the pulling force and micro computed tomographic evaluation
Jeon SJ, et al. Restor Dent Endod. 2017 Nov;42(4):273-281. https://doi.org/10.5395/rde.2017.42.4.273
- Open Access
- 4 January 2016
- Published by Springer Nature in Maxillofacial Plastic and Reconstructive Surgery
- Vol. 38 (1) , 1-4
Radiographic study of the distribution of maxillary intraosseous vascular canal in Koreans
This study aimed to investigate the distribution and prevalence of intraosseous loop (anastomosis between posterior superior alveolar artery and infraorbital artery) in Koreans detected on computed tomography (CT) images taken prior to sinus augmentation surgery. From the 177 patients who underwent sinus augmentation with lateral approach at Ewha Womans University Department of Implant Dentistry, 284 CT scans were evaluated. The canal height (CH), ridge height (RH), and canal height from the sinus floor (CHS) were measured on para-axial views at the first premolar, first molar, and second molar. The horizontal positions of the bony canals in the lateral wall were also classified. One-way analysis of variance (ANOVA) and t test were used to estimate the statistical differences (p < 0.05). The intraosseous loops were detected in 92 CT scans (32 %). The mean vertical height of the bony canals from the alveolar crest (CH) was 23.45 ± 2.81, 15.92 ± 2.65, and 16.61 ± 2.92 mm at the second premolar, first molar, and second molar, respectively. In the horizontal positions of the bony canals, intraosseous type was the most predominant. The canal heights more than 15 mm and less than 17 mm were most prevalent (33.7 %) and those under 13 mm were 12.0 %. The radiographic findings in this study could be used to decide the lateral osteotomy line avoiding potential vascular complication. However, only one third of the canals could be detected in CT scans; a precaution should be taken for the possibility of severe bleeding during lateral osteotomy.
- 4 January 2016
- Published by Springer Nature in Maxillofacial Plastic and Reconstructive Surgery
- Vol. 38 (1) , 1-4
Open AccessRadiographic study of the distribution of maxillary intraosseous vascular canal in Koreans
This study aimed to investigate the distribution and prevalence of intraosseous loop (anastomosis between posterior superior alveolar artery and infraorbital artery) in Koreans detected on computed tomography (CT) images taken prior to sinus augmentation surgery. From the 177 patients who underwent sinus augmentation with lateral approach at Ewha Womans University Department of Implant Dentistry, 284 CT scans were evaluated. The canal height (CH), ridge height (RH), and canal height from the sinus floor (CHS) were measured on para-axial views at the first premolar, first molar, and second molar. The horizontal positions of the bony canals in the lateral wall were also classified. One-way analysis of variance (ANOVA) and t test were used to estimate the statistical differences (p < 0.05). The intraosseous loops were detected in 92 CT scans (32 %). The mean vertical height of the bony canals from the alveolar crest (CH) was 23.45 ± 2.81, 15.92 ± 2.65, and 16.61 ± 2.92 mm at the second premolar, first molar, and second molar, respectively. In the horizontal positions of the bony canals, intraosseous type was the most predominant. The canal heights more than 15 mm and less than 17 mm were most prevalent (33.7 %) and those under 13 mm were 12.0 %. The radiographic findings in this study could be used to decide the lateral osteotomy line avoiding potential vascular complication. However, only one third of the canals could be detected in CT scans; a precaution should be taken for the possibility of severe bleeding during lateral osteotomy.
- Open Access
- 1 January 2016
- Published by Korean Academy of Conservative Dentistry in Restorative Dentistry & Endodontics
- Vol. 41 (4) , 262-270
Healing outcomes of root canal treatment for C-shaped mandibular second molars: a retrospective analysis
Ahn HR, et al. Restor Dent Endod. 2016 Nov;41(4):262-270. https://doi.org/10.5395/rde.2016.41.4.262
- 1 January 2016
- Published by Korean Academy of Conservative Dentistry in Restorative Dentistry & Endodontics
- Vol. 41 (4) , 262-270
Open AccessHealing outcomes of root canal treatment for C-shaped mandibular second molars: a retrospective analysis
Ahn HR, et al. Restor Dent Endod. 2016 Nov;41(4):262-270. https://doi.org/10.5395/rde.2016.41.4.262
- Open Access
- 1 January 2015
- Published by XMLink in Imaging Science in Dentistry
- Vol. 45 (4) , 221-226
Prevalence and features of distolingual roots in mandibular molars analyzed by cone-beam computed tomography
Choi MR, et al. Imaging Sci Dent. 2015 Dec;45(4):221-226. http://dx.doi.org/10.5624/isd.2015.45.4.221
- 1 January 2015
- Published by XMLink in Imaging Science in Dentistry
- Vol. 45 (4) , 221-226
Open AccessPrevalence and features of distolingual roots in mandibular molars analyzed by cone-beam computed tomography
Choi MR, et al. Imaging Sci Dent. 2015 Dec;45(4):221-226. http://dx.doi.org/10.5624/isd.2015.45.4.221
- 1 January 2015
- Published by Elsevier in Journal of Endodontics
- Vol. 41 (1) , 102-105
Fitness of Gutta-percha Cones in Curved Root Canals Prepared with Reciprocating Files Correlated with Tug-back Sensation
- 1 January 2015
- Published by Elsevier in Journal of Endodontics
- Vol. 41 (1) , 102-105
Fitness of Gutta-percha Cones in Curved Root Canals Prepared with Reciprocating Files Correlated with Tug-back Sensation
- Open Access
- 1 January 2014
- Published by Korean Academy of Conservative Dentistry in Restorative Dentistry & Endodontics
- Vol. 39 (4) , 276-281
Cutting efficiency of apical preparation using ultrasonic tips with microprojections: confocal laser scanning microscopy study
Kwak SW, et al. Restor Dent Endod. 2014 Nov;39(4):276-281. http://dx.doi.org/10.5395/rde.2014.39.4.276
- 1 January 2014
- Published by Korean Academy of Conservative Dentistry in Restorative Dentistry & Endodontics
- Vol. 39 (4) , 276-281
Open AccessCutting efficiency of apical preparation using ultrasonic tips with microprojections: confocal laser scanning microscopy study
Kwak SW, et al. Restor Dent Endod. 2014 Nov;39(4):276-281. http://dx.doi.org/10.5395/rde.2014.39.4.276
Clinical efficiency and reusability of the reciprocating nickel-titanium instruments according to the root canal anatomy
The application of the single-file technique using the reciprocating motion is gaining concern in root canal preparation. The purpose of this research is to compare the efficiency of the reciprocating motion-employing files (RECIPROC and WaveOne) by measuring the working time for complete canal shaping, and to evaluate their reusability under scanning examinations. One hundred curved root canals of the extracted molars were used. The working length was determined and the glide path was confirmed using a #15 K-file. Canals shaping was completed to the length either with RECIPROC R25 file (n = 50), or with WaveOne Primary file (n = 50). The time taken for the file to reach the working length was also measured. Each file was repeatedly used in a maximum of 10 canals for comparing the change of the efficiency (shaping time) according to the working length, canal curvature, and number of file re-use. The deformations or surface defects of the files after the in vitro use were observed using a scanning electron microscope (SEM). There was no difference under the SEM between the 2 file groups with no initiation of micro-cracks until they were re-used up to 5 canals. WaveOne Primary file showed significantly shorter working time than RECIPROC R25 (p < 0.05). There was a statistically significant correlation between the working time and three variables. As the working length and the curvature of the canal increased, the shaping time was increased in both file systems. Reusability of these reciprocating instruments might be maximum 5 canals with minimal surface deformations.
Clinical efficiency and reusability of the reciprocating nickel-titanium instruments according to the root canal anatomy
The application of the single-file technique using the reciprocating motion is gaining concern in root canal preparation. The purpose of this research is to compare the efficiency of the reciprocating motion-employing files (RECIPROC and WaveOne) by measuring the working time for complete canal shaping, and to evaluate their reusability under scanning examinations. One hundred curved root canals of the extracted molars were used. The working length was determined and the glide path was confirmed using a #15 K-file. Canals shaping was completed to the length either with RECIPROC R25 file (n = 50), or with WaveOne Primary file (n = 50). The time taken for the file to reach the working length was also measured. Each file was repeatedly used in a maximum of 10 canals for comparing the change of the efficiency (shaping time) according to the working length, canal curvature, and number of file re-use. The deformations or surface defects of the files after the in vitro use were observed using a scanning electron microscope (SEM). There was no difference under the SEM between the 2 file groups with no initiation of micro-cracks until they were re-used up to 5 canals. WaveOne Primary file showed significantly shorter working time than RECIPROC R25 (p < 0.05). There was a statistically significant correlation between the working time and three variables. As the working length and the curvature of the canal increased, the shaping time was increased in both file systems. Reusability of these reciprocating instruments might be maximum 5 canals with minimal surface deformations.
- 1 April 2012
- Published by Elsevier in Journal of Endodontics
- Vol. 38 (4) , 531-535
Effect of Laser-activated Irrigation of 1320-Nanometer Nd:YAG Laser on Sealer Penetration in Curved Root Canals
- 1 April 2012
- Published by Elsevier in Journal of Endodontics
- Vol. 38 (4) , 531-535
Effect of Laser-activated Irrigation of 1320-Nanometer Nd:YAG Laser on Sealer Penetration in Curved Root Canals