JGJan Geder

Jan Geder

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Jan Geder has a total of 24 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Thermal stability of lithium-rich manganese-based cathode

    by Jan Geder, Jay Hyok Song, Sun Ho Kang, Denis Y.W. Yu


  • Impact of active material surface area on thermal stability of LiCoO2 cathode

    by Jan Geder, Harry E. Hoster, Andreas Jossen, Jürgen Garche, Denis Y.W. Yu


  • Development of an All Kapton-Based Thin-Film Thermocouple Matrix for In Situ Temperature Measurement in a Lithium Ion Pouch Cell

    by Nora Martiny, Alexander Rheinfeld, Jan Geder, Yuxi Wang, Werner Kraus, Andreas Jossen

    Based on the design of a lithium ion battery cell and the resulting thermophysical properties, considerable temperature gradients may form within the cell not only during abusive scenarios. While the temperature gradients during normal operation are mostly negligible for small cells, which are commonly employed in mobile applications, the discrepancy between the temperature inside a battery cell and the cell's surface can be significant for larger scaled cells, which are employed, e.g., in automotive applications. Battery management systems that rely on a monitoring of the cell's surface temperature may consequently lead to an unfavorable operation of the whole battery in terms of aging and safety aspects. Thus, we hereby present an approach of designing, producing, and incorporating an all Kapton-based temperature sensor for an in situ temperature monitoring of lithium ion pouch cells. First prototypes are developed as a proof of concept when using a common potential for a thermocouple matrix that will later allow for a spatially resolved temperature monitoring within a lithium ion pouch cell. The interactions between the sensor and the cell are investigated and further design steps for improvements in functionality are elaborated.


  • Development of a thin-film thermocouple matrix for in-situ temperature measurement in a lithium ion pouch cell

    by Nora Martiny, Jan Geder, Yuxi Wang, Werner Kraus, Andreas Jossen

    As cooling systems in battery systems lead to a falsified temperature measurement when surface based temperature monitoring techniques are applied, the development of a sensor for in-situ temperature monitoring is crucial. The authors present therefore different restrictions that need to be considered when designing such a sensor. First prototypes are developed as a proof of concept of using a common potential for a thermocouple matrix that will later provide a space resolved temperature monitoring in a cell. The influence of the sensor on the cell and vice versa is investigated and improvements for further design steps are elaborated.


  • Open Access

    Electrical safety of commercial Li-ion cells based on NMC and NCA technology compared to LFP technology

    by Martin Brand, Simon Glaser, Jan Geder, Stefan Menacher, Sebastian Obpacher, Andreas Jossen, Daniel Quinger

    Since a laptop caught fire in 2006 at the latest, Li-ion cells were considered as more dangerous than other accumulators [1]. Recent incidents, such as the one involving a BYD e6 electric taxi [2] or the Boeing Dreamliner [3], give rise to questions concerning the safety of L#i-ion cells. This is a crucial point, since Li-ion cells are increasingly integrated in all kinds of (electric) vehicles. Therefore the economic success of hybrid electric vehicles (HEV) and battery electric vehicles (BEV) depends significantly on the safety of Li-ion cells. Lithium nickel manganese cobalt oxide (NMC) and lithium nickel cobalt aluminium oxide (NCA) are two standard Li-ion cathode chemistries, which are often used for today's HEVs and BEVs Li-ion batteries. Cells with this two cathode technologies are investigated in detail and compared to cells with the alleged save lithium iron phosphate (LFP) technology. Furthermore only commercially available and mass produced Li-ion cells were tested, in order to get as close to real end-user applications as possible. To ensure comparability, cells with the most common 18650 casing have been used. Furthermore all cells had no built-in resistor with positive temperature coefficient (PTC-device). For each abuse test at least 2 cells have been tested to get to know the statistical dispersion. The spread was in all tests for all measured values of each cell type lower than 11 %. Consequently it can be supposed, that mass produced cells show equal behaviour also in abusive test. The performed electrical safety tests on these cells, involve overcharge, overdischarge and short circuit tests. These tests represent real abuse scenarios and are geared to established standards [15], [16], [17], [18]. To complete these measurements an accelerated rate calorimetry (ARC) test has been carried out, to determine the thermal stability of the cells. As in the literature discussed, the investigated LFP/C cells show a higher thermal stability and are therefore safer, although they do not have any overcharge buffer as the investigated NCA/C and NMC/C cells.


  • Open Access

    Electrical safety of commercial Li-ion cells based on NMC and NCA technology compared to LFP technology

    by Martin Brand, Simon Gläser, Jan Geder, Stefan Menacher, Sebastian Obpacher, Andreas Jossen, Daniel Quinger

    Since a laptop caught fire in 2006 at the latest, Li-ion cells were considered as more dangerous than other accumulators [1]. Recent incidents, such as the one involving a BYD e6 electric taxi [2] or the Boeing Dreamliner [3], give rise to questions concerning the safety of L#i-ion cells. This is a crucial point, since Li-ion cells are increasingly integrated in all kinds of (electric) vehicles. Therefore the economic success of hybrid electric vehicles (HEV) and battery electric vehicles (BEV) depends significantly on the safety of Li-ion cells. Lithium nickel manganese cobalt oxide (NMC) and lithium nickel cobalt aluminium oxide (NCA) are two standard Li-ion cathode chemistries, which are often used for today’s HEVs and BEVs Li-ion batteries. Cells with this two cathode technologies are investigated in detail and compared to cells with the alleged save lithium iron phosphate (LFP) technology. Furthermore only commercially available and mass produced Li-ion cells were tested, in order to get as close to real end-user applications as possible. To ensure comparability, cells with the most common 18650 casing have been used. Furthermore all cells had no built-in resistor with positive temperature coefficient (PTC-device). For each abuse test at least 2 cells have been tested to get to know the statistical dispersion. The spread was in all tests for all measured values of each cell type lower than 11 %. Consequently it can be supposed, that mass produced cells show equal behaviour also in abusive test. The performed electrical safety tests on these cells, involve overcharge, overdischarge and short circuit tests. These tests represent real abuse scenarios and are geared to established standards [15], [16], [17], [18]. To complete these measurements an accelerated rate calorimetry (ARC) test has been carried out, to determine the thermal stability of the cells. As in the literature discussed, the investigated LFP/C cells show a higher thermal stability and are therefore safer, although they do not have any overcharge buffer as the investigated NCA/C and NMC/C cells.