Jan Geder
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Jan Geder has a total of 24 co-authors. Here are the top co-authors by number of shared publications:
- Andreas Jossen
Technical University of Munich
5 shared publications - Denis Yau Wai Yu
Center for Green Research on Energy and Environmental Materials, National Institute for Materials Science (NIMS), Tsukuba, Ibaraki 305-0044, Japan
2 shared publications Sebastian Obpacher
TÜV SÜD Battery Testing GmbH, Daimlerstr. 15, 85748 Garching, Germany
2 shared publicationsStefan Menacher
TÜV SÜD Battery Testing GmbH, Daimlerstr. 15, 85748 Garching, Germany
2 shared publicationsWerner Kraus
Institute for Technical Electronics, Technical University of Munich, Munich, Germany
2 shared publicationsYuxi Wang
TUM CREATE Ltd., Singapore
2 shared publications
Latest Publications
- 1 December 2014
- Published by Elsevier in Solid State Ionics
- Vol. 268, 242-246
Thermal stability of lithium-rich manganese-based cathode
- 1 December 2014
- Published by Elsevier in Solid State Ionics
- Vol. 268, 242-246
Thermal stability of lithium-rich manganese-based cathode
- 1 July 2014
- Published by Elsevier in Journal of Power Sources
- Vol. 257, 286-292
Impact of active material surface area on thermal stability of LiCoO2 cathode
- 1 July 2014
- Published by Elsevier in Journal of Power Sources
- Vol. 257, 286-292
Impact of active material surface area on thermal stability of LiCoO2 cathode
- 19 June 2014
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 14 (10) , 3377-3384
Development of an All Kapton-Based Thin-Film Thermocouple Matrix for In Situ Temperature Measurement in a Lithium Ion Pouch Cell
Based on the design of a lithium ion battery cell and the resulting thermophysical properties, considerable temperature gradients may form within the cell not only during abusive scenarios. While the temperature gradients during normal operation are mostly negligible for small cells, which are commonly employed in mobile applications, the discrepancy between the temperature inside a battery cell and the cell's surface can be significant for larger scaled cells, which are employed, e.g., in automotive applications. Battery management systems that rely on a monitoring of the cell's surface temperature may consequently lead to an unfavorable operation of the whole battery in terms of aging and safety aspects. Thus, we hereby present an approach of designing, producing, and incorporating an all Kapton-based temperature sensor for an in situ temperature monitoring of lithium ion pouch cells. First prototypes are developed as a proof of concept when using a common potential for a thermocouple matrix that will later allow for a spatially resolved temperature monitoring within a lithium ion pouch cell. The interactions between the sensor and the cell are investigated and further design steps for improvements in functionality are elaborated.
- 19 June 2014
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 14 (10) , 3377-3384
Development of an All Kapton-Based Thin-Film Thermocouple Matrix for In Situ Temperature Measurement in a Lithium Ion Pouch Cell
Based on the design of a lithium ion battery cell and the resulting thermophysical properties, considerable temperature gradients may form within the cell not only during abusive scenarios. While the temperature gradients during normal operation are mostly negligible for small cells, which are commonly employed in mobile applications, the discrepancy between the temperature inside a battery cell and the cell's surface can be significant for larger scaled cells, which are employed, e.g., in automotive applications. Battery management systems that rely on a monitoring of the cell's surface temperature may consequently lead to an unfavorable operation of the whole battery in terms of aging and safety aspects. Thus, we hereby present an approach of designing, producing, and incorporating an all Kapton-based temperature sensor for an in situ temperature monitoring of lithium ion pouch cells. First prototypes are developed as a proof of concept when using a common potential for a thermocouple matrix that will later allow for a spatially resolved temperature monitoring within a lithium ion pouch cell. The interactions between the sensor and the cell are investigated and further design steps for improvements in functionality are elaborated.
- 1 November 2013
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 19300395,p. 1-4
Development of a thin-film thermocouple matrix for in-situ temperature measurement in a lithium ion pouch cell
As cooling systems in battery systems lead to a falsified temperature measurement when surface based temperature monitoring techniques are applied, the development of a sensor for in-situ temperature monitoring is crucial. The authors present therefore different restrictions that need to be considered when designing such a sensor. First prototypes are developed as a proof of concept of using a common potential for a thermocouple matrix that will later provide a space resolved temperature monitoring in a cell. The influence of the sensor on the cell and vice versa is investigated and improvements for further design steps are elaborated.
- 1 November 2013
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 19300395,p. 1-4
Development of a thin-film thermocouple matrix for in-situ temperature measurement in a lithium ion pouch cell
As cooling systems in battery systems lead to a falsified temperature measurement when surface based temperature monitoring techniques are applied, the development of a sensor for in-situ temperature monitoring is crucial. The authors present therefore different restrictions that need to be considered when designing such a sensor. First prototypes are developed as a proof of concept of using a common potential for a thermocouple matrix that will later provide a space resolved temperature monitoring in a cell. The influence of the sensor on the cell and vice versa is investigated and improvements for further design steps are elaborated.
- Open Access
- 1 November 2013
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-9
Electrical safety of commercial Li-ion cells based on NMC and NCA technology compared to LFP technology
Since a laptop caught fire in 2006 at the latest, Li-ion cells were considered as more dangerous than other accumulators [1]. Recent incidents, such as the one involving a BYD e6 electric taxi [2] or the Boeing Dreamliner [3], give rise to questions concerning the safety of L#i-ion cells. This is a crucial point, since Li-ion cells are increasingly integrated in all kinds of (electric) vehicles. Therefore the economic success of hybrid electric vehicles (HEV) and battery electric vehicles (BEV) depends significantly on the safety of Li-ion cells. Lithium nickel manganese cobalt oxide (NMC) and lithium nickel cobalt aluminium oxide (NCA) are two standard Li-ion cathode chemistries, which are often used for today's HEVs and BEVs Li-ion batteries. Cells with this two cathode technologies are investigated in detail and compared to cells with the alleged save lithium iron phosphate (LFP) technology. Furthermore only commercially available and mass produced Li-ion cells were tested, in order to get as close to real end-user applications as possible. To ensure comparability, cells with the most common 18650 casing have been used. Furthermore all cells had no built-in resistor with positive temperature coefficient (PTC-device). For each abuse test at least 2 cells have been tested to get to know the statistical dispersion. The spread was in all tests for all measured values of each cell type lower than 11 %. Consequently it can be supposed, that mass produced cells show equal behaviour also in abusive test. The performed electrical safety tests on these cells, involve overcharge, overdischarge and short circuit tests. These tests represent real abuse scenarios and are geared to established standards [15], [16], [17], [18]. To complete these measurements an accelerated rate calorimetry (ARC) test has been carried out, to determine the thermal stability of the cells. As in the literature discussed, the investigated LFP/C cells show a higher thermal stability and are therefore safer, although they do not have any overcharge buffer as the investigated NCA/C and NMC/C cells.
- 1 November 2013
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-9
Open AccessElectrical safety of commercial Li-ion cells based on NMC and NCA technology compared to LFP technology
Since a laptop caught fire in 2006 at the latest, Li-ion cells were considered as more dangerous than other accumulators [1]. Recent incidents, such as the one involving a BYD e6 electric taxi [2] or the Boeing Dreamliner [3], give rise to questions concerning the safety of L#i-ion cells. This is a crucial point, since Li-ion cells are increasingly integrated in all kinds of (electric) vehicles. Therefore the economic success of hybrid electric vehicles (HEV) and battery electric vehicles (BEV) depends significantly on the safety of Li-ion cells. Lithium nickel manganese cobalt oxide (NMC) and lithium nickel cobalt aluminium oxide (NCA) are two standard Li-ion cathode chemistries, which are often used for today's HEVs and BEVs Li-ion batteries. Cells with this two cathode technologies are investigated in detail and compared to cells with the alleged save lithium iron phosphate (LFP) technology. Furthermore only commercially available and mass produced Li-ion cells were tested, in order to get as close to real end-user applications as possible. To ensure comparability, cells with the most common 18650 casing have been used. Furthermore all cells had no built-in resistor with positive temperature coefficient (PTC-device). For each abuse test at least 2 cells have been tested to get to know the statistical dispersion. The spread was in all tests for all measured values of each cell type lower than 11 %. Consequently it can be supposed, that mass produced cells show equal behaviour also in abusive test. The performed electrical safety tests on these cells, involve overcharge, overdischarge and short circuit tests. These tests represent real abuse scenarios and are geared to established standards [15], [16], [17], [18]. To complete these measurements an accelerated rate calorimetry (ARC) test has been carried out, to determine the thermal stability of the cells. As in the literature discussed, the investigated LFP/C cells show a higher thermal stability and are therefore safer, although they do not have any overcharge buffer as the investigated NCA/C and NMC/C cells.
- Open Access
- 27 September 2013
- Published by MDPI AG in World Electric Vehicle Journal
- Vol. 6 (3) , 572-580
Electrical safety of commercial Li-ion cells based on NMC and NCA technology compared to LFP technology
Since a laptop caught fire in 2006 at the latest, Li-ion cells were considered as more dangerous than other accumulators [1]. Recent incidents, such as the one involving a BYD e6 electric taxi [2] or the Boeing Dreamliner [3], give rise to questions concerning the safety of L#i-ion cells. This is a crucial point, since Li-ion cells are increasingly integrated in all kinds of (electric) vehicles. Therefore the economic success of hybrid electric vehicles (HEV) and battery electric vehicles (BEV) depends significantly on the safety of Li-ion cells. Lithium nickel manganese cobalt oxide (NMC) and lithium nickel cobalt aluminium oxide (NCA) are two standard Li-ion cathode chemistries, which are often used for today’s HEVs and BEVs Li-ion batteries. Cells with this two cathode technologies are investigated in detail and compared to cells with the alleged save lithium iron phosphate (LFP) technology. Furthermore only commercially available and mass produced Li-ion cells were tested, in order to get as close to real end-user applications as possible. To ensure comparability, cells with the most common 18650 casing have been used. Furthermore all cells had no built-in resistor with positive temperature coefficient (PTC-device). For each abuse test at least 2 cells have been tested to get to know the statistical dispersion. The spread was in all tests for all measured values of each cell type lower than 11 %. Consequently it can be supposed, that mass produced cells show equal behaviour also in abusive test. The performed electrical safety tests on these cells, involve overcharge, overdischarge and short circuit tests. These tests represent real abuse scenarios and are geared to established standards [15], [16], [17], [18]. To complete these measurements an accelerated rate calorimetry (ARC) test has been carried out, to determine the thermal stability of the cells. As in the literature discussed, the investigated LFP/C cells show a higher thermal stability and are therefore safer, although they do not have any overcharge buffer as the investigated NCA/C and NMC/C cells.
- 27 September 2013
- Published by MDPI AG in World Electric Vehicle Journal
- Vol. 6 (3) , 572-580
Open AccessElectrical safety of commercial Li-ion cells based on NMC and NCA technology compared to LFP technology
Since a laptop caught fire in 2006 at the latest, Li-ion cells were considered as more dangerous than other accumulators [1]. Recent incidents, such as the one involving a BYD e6 electric taxi [2] or the Boeing Dreamliner [3], give rise to questions concerning the safety of L#i-ion cells. This is a crucial point, since Li-ion cells are increasingly integrated in all kinds of (electric) vehicles. Therefore the economic success of hybrid electric vehicles (HEV) and battery electric vehicles (BEV) depends significantly on the safety of Li-ion cells. Lithium nickel manganese cobalt oxide (NMC) and lithium nickel cobalt aluminium oxide (NCA) are two standard Li-ion cathode chemistries, which are often used for today’s HEVs and BEVs Li-ion batteries. Cells with this two cathode technologies are investigated in detail and compared to cells with the alleged save lithium iron phosphate (LFP) technology. Furthermore only commercially available and mass produced Li-ion cells were tested, in order to get as close to real end-user applications as possible. To ensure comparability, cells with the most common 18650 casing have been used. Furthermore all cells had no built-in resistor with positive temperature coefficient (PTC-device). For each abuse test at least 2 cells have been tested to get to know the statistical dispersion. The spread was in all tests for all measured values of each cell type lower than 11 %. Consequently it can be supposed, that mass produced cells show equal behaviour also in abusive test. The performed electrical safety tests on these cells, involve overcharge, overdischarge and short circuit tests. These tests represent real abuse scenarios and are geared to established standards [15], [16], [17], [18]. To complete these measurements an accelerated rate calorimetry (ARC) test has been carried out, to determine the thermal stability of the cells. As in the literature discussed, the investigated LFP/C cells show a higher thermal stability and are therefore safer, although they do not have any overcharge buffer as the investigated NCA/C and NMC/C cells.
- 1 March 2012
- Published by Elsevier in Fuel Processing Technology
- Vol. 95, 144-153
Optimization of adsorptive desulfurization process of jet fuels for application in fuel cell systems
- 1 March 2012
- Published by Elsevier in Fuel Processing Technology
- Vol. 95, 144-153
Optimization of adsorptive desulfurization process of jet fuels for application in fuel cell systems