Pekka Saarinen
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Pekka Saarinen has a total of 84 co-authors. Here are the top co-authors by number of shared publications:
Hannu Koskela
Finnish Institute of Occupational Health
7 shared publicationsJyrki K. Kauppinen
University of Turku, Turku, Finland
3 shared publicationsJyrki Kauppinen
3 shared publicationsPetri Kalliomäki
Finnish Institute of Occupational Health
3 shared publications- Risto Kosonen
Aalto University
3 shared publications - Valtteri Hongisto
Acoustics Laboratory, Turku University of Applied Sciences, Joukahaisenkatu 3–5, FI-20520 Turku, Finland
3 shared publications
Latest Publications
- Open Access
- 21 May 2024
- Published by Elsevier in Construction and Building Materials
- Vol. 433
Dynamic properties of resilient studs used in soundproof multilayer constructions – Measurement method and database
- 21 May 2024
- Published by Elsevier in Construction and Building Materials
- Vol. 433
Open AccessDynamic properties of resilient studs used in soundproof multilayer constructions – Measurement method and database
- Open Access
- 9 July 2023
- Published by Elsevier in Data in Brief
- Vol. 49, 109393
Sound insulation dataset of 30 wooden and 8 concrete floors tested in laboratory conditions
- 9 July 2023
- Published by Elsevier in Data in Brief
- Vol. 49, 109393
Open AccessSound insulation dataset of 30 wooden and 8 concrete floors tested in laboratory conditions
- Open Access
- 21 January 2022
- Published by Elsevier in Renewable and Sustainable Energy Reviews
- Vol. 157
Health effects of wind turbine noise and road traffic noise on people living near wind turbines
- 21 January 2022
- Published by Elsevier in Renewable and Sustainable Energy Reviews
- Vol. 157
Open AccessHealth effects of wind turbine noise and road traffic noise on people living near wind turbines
- 1 January 2020
- Published by Elsevier
List of Contributors
- 27 August 2019
- Published by Taylor & Francis in International Journal of Environmental Health Research
- Vol. 31 (4) , 374-388
Emissions, airflow patterns and modeling of test compounds in controlled hospital environments
Spreading and distribution of selected volatile organic compounds (VOCs) released as point source emissions in a hospital environment were investigated in two office rooms and two patient rooms. Six tracer compounds were released from six locations and their concentrations were measured in five sampling sites during two consecutive days. The air flow rates, velocity and flow direction, air temperature, pressure differences between adjacent rooms, and relative humidity and concentrations of the tracer compounds were measured. The results revealed that the size of the examined space and ventilation rates, the monitoring point should be either close to the exhaust terminal device or in the middle of the occupied zone the way that supply air flows do not interfere the measurements. Depending on the inlet terminal device and its location, the air is either delivered parallel to the ceiling or it can be directed to a desired spot into the occupied zone. The tracer compounds did spread evenly within the room and their concentrations decreased inversely with the distance. In rooms with a good ventilation, the concentrations at the exhaust air terminal units were close to those measured near the source point. The results obtained from modeling were consistent with the measurements.
- 27 August 2019
- Published by Taylor & Francis in International Journal of Environmental Health Research
- Vol. 31 (4) , 374-388
Emissions, airflow patterns and modeling of test compounds in controlled hospital environments
Spreading and distribution of selected volatile organic compounds (VOCs) released as point source emissions in a hospital environment were investigated in two office rooms and two patient rooms. Six tracer compounds were released from six locations and their concentrations were measured in five sampling sites during two consecutive days. The air flow rates, velocity and flow direction, air temperature, pressure differences between adjacent rooms, and relative humidity and concentrations of the tracer compounds were measured. The results revealed that the size of the examined space and ventilation rates, the monitoring point should be either close to the exhaust terminal device or in the middle of the occupied zone the way that supply air flows do not interfere the measurements. Depending on the inlet terminal device and its location, the air is either delivered parallel to the ceiling or it can be directed to a desired spot into the occupied zone. The tracer compounds did spread evenly within the room and their concentrations decreased inversely with the distance. In rooms with a good ventilation, the concentrations at the exhaust air terminal units were close to those measured near the source point. The results obtained from modeling were consistent with the measurements.
- 1 February 2019
- Published by Elsevier in Applied Acoustics
- Vol. 145, 358-361
Annoyance of low-level tonal sounds – A penalty model
- 1 February 2019
- Published by Elsevier in Applied Acoustics
- Vol. 145, 358-361
Annoyance of low-level tonal sounds – A penalty model
- 26 November 2018
- Published by Taylor & Francis in International Journal of Environmental Health Research
- Vol. 29 (5) , 479-488
Indoor air-related symptoms and volatile organic compounds in materials and air in the hospital environment
In this case study, hospital workers did suffer from symptoms related to the poor indoor air quality. To investigate reasons for symptoms MM40-survey and house inspection methods were performed. The study consisted of 49 operating rooms and 470 employees. MM-40 survey revealed that over 40% of the staff suffered from skin reactions, over 50% had upper respiratory tract symptoms and 25% suffered headaches. No reason for the staff’s symptom could be found in the structural studies of workplaces. The mean air exchange rate of the rooms was 5.51/h. In total 61 materials and 49 indoor air samples were taken. The most frequently found compounds in the material samples were 2-ethyl-1-hexanol and aliphatic hydrocarbons. VOC emissions were high in some of the material samples and they presumably were the one reason for the workers’ symptoms observed in some in of the rooms. However, indoor air VOC concentrations were low in most of the cases. According to the linear regression model emissions from flooring material couldn’t explain the indoor air concentration of the VOCs. One reason for that was the high ventilation rates of the rooms, which presumably kept VOC levels in indoors low. In addition, VOC concentrations indoors were strongly related to the ongoing healthcare activities in the hospital.
- 26 November 2018
- Published by Taylor & Francis in International Journal of Environmental Health Research
- Vol. 29 (5) , 479-488
Indoor air-related symptoms and volatile organic compounds in materials and air in the hospital environment
In this case study, hospital workers did suffer from symptoms related to the poor indoor air quality. To investigate reasons for symptoms MM40-survey and house inspection methods were performed. The study consisted of 49 operating rooms and 470 employees. MM-40 survey revealed that over 40% of the staff suffered from skin reactions, over 50% had upper respiratory tract symptoms and 25% suffered headaches. No reason for the staff’s symptom could be found in the structural studies of workplaces. The mean air exchange rate of the rooms was 5.51/h. In total 61 materials and 49 indoor air samples were taken. The most frequently found compounds in the material samples were 2-ethyl-1-hexanol and aliphatic hydrocarbons. VOC emissions were high in some of the material samples and they presumably were the one reason for the workers’ symptoms observed in some in of the rooms. However, indoor air VOC concentrations were low in most of the cases. According to the linear regression model emissions from flooring material couldn’t explain the indoor air concentration of the VOCs. One reason for that was the high ventilation rates of the rooms, which presumably kept VOC levels in indoors low. In addition, VOC concentrations indoors were strongly related to the ongoing healthcare activities in the hospital.
- 6 November 2017
- Published by Springer Nature in Building Simulation
- Vol. 11 (3) , 585-596
Large-eddy simulation of the containment failure in isolation rooms with a sliding door—An experimental and modelling study
In hospital isolation rooms, door operation can lead to containment failures and airborne pathogen dispersal into the surrounding spaces. Sliding doors can reduce the containment failure arising from the door motion induced airflows, as compared to the hinged doors that are typically used in healthcare facilities. Such airflow leakage can be measured quantitatively using tracer gas techniques, but detailed observation of the turbulent flow features is very difficult. However, a comprehensive understanding of these flows is important when designing doors to further reduce such containment failures. Experiments and Computational Fluid Dynamics (CFD) modelling, by using Large-Eddy Simulation (LES) flow solver, were used to study airflow patterns in a full-scale mock-up, consisting of a sliding door separating two identical rooms (i.e. one isolation room attached to an antechamber). A single sliding door open/ hold-open/ closing cycle was studied. Additional variables included human passage through the doorway and imposing a temperature difference between the two rooms. The general structures of computationally-simulated flow features were validated by comparing the results to smoke visualizations of identical full-scale experimental set-ups. It was found that without passage the air volume leakage across the doorway was first dominated by vortex shedding in the wake of the door, but during a prolonged hold-open period a possible temperature difference soon became the predominant driving force. Passage generates a short and powerful pulse of leakage flow rate even if the walker stops to wait for the door to open.
- 6 November 2017
- Published by Springer Nature in Building Simulation
- Vol. 11 (3) , 585-596
Large-eddy simulation of the containment failure in isolation rooms with a sliding door—An experimental and modelling study
In hospital isolation rooms, door operation can lead to containment failures and airborne pathogen dispersal into the surrounding spaces. Sliding doors can reduce the containment failure arising from the door motion induced airflows, as compared to the hinged doors that are typically used in healthcare facilities. Such airflow leakage can be measured quantitatively using tracer gas techniques, but detailed observation of the turbulent flow features is very difficult. However, a comprehensive understanding of these flows is important when designing doors to further reduce such containment failures. Experiments and Computational Fluid Dynamics (CFD) modelling, by using Large-Eddy Simulation (LES) flow solver, were used to study airflow patterns in a full-scale mock-up, consisting of a sliding door separating two identical rooms (i.e. one isolation room attached to an antechamber). A single sliding door open/ hold-open/ closing cycle was studied. Additional variables included human passage through the doorway and imposing a temperature difference between the two rooms. The general structures of computationally-simulated flow features were validated by comparing the results to smoke visualizations of identical full-scale experimental set-ups. It was found that without passage the air volume leakage across the doorway was first dominated by vortex shedding in the wake of the door, but during a prolonged hold-open period a possible temperature difference soon became the predominant driving force. Passage generates a short and powerful pulse of leakage flow rate even if the walker stops to wait for the door to open.
- 18 May 2016
- Published by Taylor & Francis in International Journal of Ventilation
- Vol. 15 (1) , 45-66
Simulation of HVAC flow noise sources with an exit vent as an example
The control of flow noise is an important design aspect nowadays in the HVAC industry. However, acoustic design has largely been based on trial and error, which leaves the physical mechanisms responsible for the noise problems unexplained. Thus, a method is needed to analyse these mechanisms. The standard flow-modelling software used in industry misses the link between the flow and the far-field sound pressure. In the automotive and aviation industry, acoustic solver software products have been introduced to cover this gap. In this paper, a trade-off solution is proposed based on using standard flow simulation software to simulate the transient acoustic source field. This approach can be used to tackle some basic questions like where the noise is generated, which of the alternative geometrical variations is likely to produce least noise, or whether there could be distinct tones present at some frequencies. Source field analysis is also a useful intermediate phase prior to implementing an acoustic solver.
- 18 May 2016
- Published by Taylor & Francis in International Journal of Ventilation
- Vol. 15 (1) , 45-66
Simulation of HVAC flow noise sources with an exit vent as an example
The control of flow noise is an important design aspect nowadays in the HVAC industry. However, acoustic design has largely been based on trial and error, which leaves the physical mechanisms responsible for the noise problems unexplained. Thus, a method is needed to analyse these mechanisms. The standard flow-modelling software used in industry misses the link between the flow and the far-field sound pressure. In the automotive and aviation industry, acoustic solver software products have been introduced to cover this gap. In this paper, a trade-off solution is proposed based on using standard flow simulation software to simulate the transient acoustic source field. This approach can be used to tackle some basic questions like where the noise is generated, which of the alternative geometrical variations is likely to produce least noise, or whether there could be distinct tones present at some frequencies. Source field analysis is also a useful intermediate phase prior to implementing an acoustic solver.
- 1 April 2016
- Published by Springer Nature in Building Simulation
- Vol. 9 (5) , 569-581
An easy-to-use turbulent inlet boundary condition for large-eddy simulation of radial diffusers
- 1 April 2016
- Published by Springer Nature in Building Simulation
- Vol. 9 (5) , 569-581
An easy-to-use turbulent inlet boundary condition for large-eddy simulation of radial diffusers