JCJiawei Marvin Chan

Jiawei Marvin Chan

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Jiawei Marvin Chan has a total of 4 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Effects of Copper Migration on the Reliability of Through-Silicon Via (TSV)

    by Jiawei Marvin Chan, Kheng Chooi Lee, Chuan Seng Tan

    Non-destructive electrical characterization was performed to detect copper migration in a degraded through-silicon via structure after various stressing conditions, such as elevated temperature exposure, temperature cycling, and electrical biasing. They were performed either independently or as a combination with electrical bias for comparison. Variations in the electrical characteristics reflect the presence of copper. The electrical characteristics were also able to monitor the transport of copper ions from an applied electric field. Physical failure analysis was performed to verify the presence of migrated copper, correlating with the changes observed during electrical measurement. With this understanding, reliability assessments become possible where this paper seeks to value add to verify the influence of Cu migration on the conduction mechanism and time-dependent dielectric breakdown (TDDB) lifetime, in which there is currently a lack in understanding. The conduction mechanism was fitted with experimental data before and after degradation and it was deduced that the Poole-Frenkel conduction mechanism is the dominant mechanism after degradation. However, this is dependent on the copper oxidation state which was verified to change over time from Cu2O to CuO by X-ray photoelectron spectroscopy. TDDB experiments were also performed based on this understanding and found that the presence of copper may accelerate or decelerate time to failure. TDDB lifetime was fitted experimentally and is found to be in good agreement with the √E model. It was verified experimentally by measuring the time to failure at low E-field within reasonable failure time, rather than extrapolating from data at high field.


  • Observations of copper (Cu) transport in through-silicon vias (TSV) structure by electrical characterization for its reliability evaluation

    by Jiawei Marvin Chan, Chuan Seng Tan, Kheng Chooi Lee, Xu Cheng, Werner Kanert

    Through-silicon via (TSV) has in recent years been actively pursued and has become one of the key enablers for three dimensional (3D) IC. However, one of the widely used filler material for TSV is copper (Cu), which readily diffuses into the dielectric layer. In this study, the monitoring of Cu ions transport within the dielectric layer is observed and controlled for its reliability assessment. Cu ions can be driven towards the silicon dioxide (SiO2) or back to the Cu bulk by applying an appropriate E-field. Time dependent dielectric breakdown (TDDB) was then performed at various conditions and it was found that the breakdown mechanism is different, dependent on the tested, E-field and temperature where Cu ions could play different roles in the dielectric. Finally the extension of TDDB lifetime was also demonstrated with appropriate control of the Cu ions, based on the understanding of the breakdown mechanism.


  • Reliability evaluation of copper (Cu) through-silicon via (TSV) barrier and dielectric liner by electrical characterization

    by Jiawei Marvin Chan, Xu Cheng, Kheng Chooi Lee, Werner Kanert, Chuan Seng Tan

    The purpose of this study is to analyze the failure mechanisms of copper (Cu) through silicon via (TSV) with titanium (Ti) barrier and silicon dioxide (SiO2) dielectric liner, following various stress tests such as electrical, temperature cycling (TC) and high temperature storage (HTS) via electrical characterization methods. The various stresses are performed individually or in a combination of TC or HTS with electrical bias for comparison. Capacitance-voltage (C-V) and current density-electric field (J-E) characteristics were plotted after the respective stresses, to detect any changes in its electrical characteristics. Results from C-V and J-E plots suggest that barrier degradation is related to material and structural influence. The degradation in the barrier layer can lead to Cu diffusion and drift into the dielectric layer, which is reflected by changes to the minimum depletion capacitance measured in the C-V curve. An increase or decrease in the minimum depletion capacitance measured indicates Cu ions presence in SiO2 or silicon (Si) substrate respectively. The individual stresses performed reveal that there was insignificant copper existence in the dielectric layer. However a combination of stresses which involves an additional electrical bias stress on TC or HTS sample better enabled the detection of degraded barrier by electrical means. The electrical bias serves as a driving force for Cu ions drift through degraded barrier as Cu does not readily diffuse into SiO2 at room temperature. On the other hand, by increasing the number of TSVs measured in an array structure, it is found that degraded barrier and Cu trace was detected without the need for subsequent electrical bias stress.