Harun Turker
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Harun Turker has a total of 13 co-authors. Here are the top co-authors by number of shared publications:
- Seddik Bacha
Univ. Grenoble Alpes, CNRS, Grenoble INP, G2Elab, 38000 Grenoble, France
5 shared publications - Ahmad Hably
LAGEPP laboratory, Université Claude Bernard Lyon 1, Villeurbanne, France
2 shared publications A. Florescu
Grenoble Electrical Engineering Laboratory (G2Elab), Grenoble, France
1 shared publicationAdrian Radu
Grenoble Electrical Engineering Laboratory (G2Elab), 11 rue des mathématiques, Saint Martin d'Hères, 38402, France
1 shared publication- Antoine Labonne
Univ. Grenoble Alpes, CNRS, Grenoble INP, G2Elab, Grenoble, France
1 shared publication D. Frey
Grenoble Electrical Engineering Laboratory (G2Elab), 11 rue des mathématiques, Saint Martin d'Hères, 38402, France
1 shared publication
Latest Publications
- 22 September 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Transportation Electrification
- Vol. 10 (3) , 4746-4756
A Predictive Two-Stage User-Centered Algorithm for Smart Charging of Plug-In Electric Vehicles Considering the State of Health of the Battery
This paper presents a novel user-centered smart charging algorithm that follows different energy management scenarios for plug-in electric vehicles (PEVs) based on the user’s demand. The proposed approach consists of two separate stages: the model predictive control (MPC) with linear optimization and the rule-based fast method. This algorithm aims to reduce the total cost of energy exchanged with the grid from the user’s point of view while consuming the maximum photovoltaic (PV) power generation. In this regard, various scenarios are predicted and provided to the user in the form of charging costs and the state of health (SOH) of the PEV battery. Then, based on the user’s choices, the desired charging scenario is applied and the probable online small errors due to the other uncertainties are compensated. The effectiveness and flexibility of the proposed algorithm are evaluated through various simulation results for three PEVs at the same time. In addition, to provide further verification, the real-time part of the algorithm is executed in OPAL-RT simulator (OP5700) including the power hardware-in-the-loop (HIL) method.
- 22 September 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Transportation Electrification
- Vol. 10 (3) , 4746-4756
A Predictive Two-Stage User-Centered Algorithm for Smart Charging of Plug-In Electric Vehicles Considering the State of Health of the Battery
This paper presents a novel user-centered smart charging algorithm that follows different energy management scenarios for plug-in electric vehicles (PEVs) based on the user’s demand. The proposed approach consists of two separate stages: the model predictive control (MPC) with linear optimization and the rule-based fast method. This algorithm aims to reduce the total cost of energy exchanged with the grid from the user’s point of view while consuming the maximum photovoltaic (PV) power generation. In this regard, various scenarios are predicted and provided to the user in the form of charging costs and the state of health (SOH) of the PEV battery. Then, based on the user’s choices, the desired charging scenario is applied and the probable online small errors due to the other uncertainties are compensated. The effectiveness and flexibility of the proposed algorithm are evaluated through various simulation results for three PEVs at the same time. In addition, to provide further verification, the real-time part of the algorithm is executed in OPAL-RT simulator (OP5700) including the power hardware-in-the-loop (HIL) method.
- 28 August 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Vehicular Technology
- Vol. 67 (11) , 10281-10292
Optimal Minimization of Plug-In Electric Vehicle Charging Cost With Vehicle-to-Home and Vehicle-to-Grid Concepts
This paper deals with the problematic of the Plug-in Electric Vehicles charging costs in housing sector. A review of the optimal strategies is proposed and as such six algorithms are presented: three smart unidirectional and three smart bidirectional charging algorithms where the Vehicle-to-Grid and the Vehicle-to-Home concepts were exploited. In addition an innovative V2G algorithm named Optimal Logical Control (V2G-OLC) is introduced in this paper. This latter is dedicated to the French energy billing system within the peak/base hours contract. All the algorithms are tested over a set of 1000 data composed of real elements with four different Daily Energy Price profiles. The results show a great efficiency of the V2G-OLC algorithm compared to the traditional optimal charging strategies. Indeed, the results show a reduction of 47.94% of the average charging cost with a unitary selling/buying price ratio in comparison to the simple charging at 230V-32A.
- 28 August 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Vehicular Technology
- Vol. 67 (11) , 10281-10292
Optimal Minimization of Plug-In Electric Vehicle Charging Cost With Vehicle-to-Home and Vehicle-to-Grid Concepts
This paper deals with the problematic of the Plug-in Electric Vehicles charging costs in housing sector. A review of the optimal strategies is proposed and as such six algorithms are presented: three smart unidirectional and three smart bidirectional charging algorithms where the Vehicle-to-Grid and the Vehicle-to-Home concepts were exploited. In addition an innovative V2G algorithm named Optimal Logical Control (V2G-OLC) is introduced in this paper. This latter is dedicated to the French energy billing system within the peak/base hours contract. All the algorithms are tested over a set of 1000 data composed of real elements with four different Daily Energy Price profiles. The results show a great efficiency of the V2G-OLC algorithm compared to the traditional optimal charging strategies. Indeed, the results show a reduction of 47.94% of the average charging cost with a unitary selling/buying price ratio in comparison to the simple charging at 230V-32A.
- 1 June 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 243-247
Optimal Charging of Plug-in Electric Vehicle (PEV) in Residential Area
This paper presents the majority of the possible charging algorithms in the context of the charge of one vehicle in a housing. As such six optimal strategies are proposed: three smart unidirectional and three smart bidirectional algorithms where the Vehicle-to-Grid (V2G) and the Vehicle-to-Home (V2H) concepts were exploited. The common aim of the six algorithms is to minimize the charging cost of the Plug-in Electric Vehicle (PEV). Linear Programming method is used to solve the optimization problem. The use case results show the great economic profitability potential of the optimal bidirectional algorithms. In addition, the results show also the largely influence of the shape of the Daily Energy Price (DEP) profile.
- 1 June 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 243-247
Optimal Charging of Plug-in Electric Vehicle (PEV) in Residential Area
This paper presents the majority of the possible charging algorithms in the context of the charge of one vehicle in a housing. As such six optimal strategies are proposed: three smart unidirectional and three smart bidirectional algorithms where the Vehicle-to-Grid (V2G) and the Vehicle-to-Home (V2H) concepts were exploited. The common aim of the six algorithms is to minimize the charging cost of the Plug-in Electric Vehicle (PEV). Linear Programming method is used to solve the optimization problem. The use case results show the great economic profitability potential of the optimal bidirectional algorithms. In addition, the results show also the largely influence of the shape of the Daily Energy Price (DEP) profile.
- 1 October 2014
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 945-951
Optimal charge control of electric vehicles in parking stations for cost minimization in V2G concept
In this paper, we consider the coordinated charging control of electrical vehicle (EV) in the charging stations. The goals are to minimize the total charging cost of all the vehicles at the charging station, respecting subscription type to electricity for charging station. The algorithm is based on a given future electricity prices and uses linear programming. This cost reduction of charging being achieved through bidirectional power flow between vehicles and grid. Thus functionalities of electrical vehicle can be divided into two aspects: on one hand, battery of the EV can be considered as a variable load. With optimal charging or smart charging for the battery, vehicle owners could maximize their profits by purchasing energy, G2V (Grid to Vehicle), at the lowest possible electricity price and in on the other hand, battery of the EV canal so be considered as energy storage capacity which has possibility to provide energy V2G (Vehicle to Grid). After the simulations performed by applying this strategy to coordinate EV charging, we achieved a cost reduction with 20% from the initial cost.
- 1 October 2014
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 945-951
Optimal charge control of electric vehicles in parking stations for cost minimization in V2G concept
In this paper, we consider the coordinated charging control of electrical vehicle (EV) in the charging stations. The goals are to minimize the total charging cost of all the vehicles at the charging station, respecting subscription type to electricity for charging station. The algorithm is based on a given future electricity prices and uses linear programming. This cost reduction of charging being achieved through bidirectional power flow between vehicles and grid. Thus functionalities of electrical vehicle can be divided into two aspects: on one hand, battery of the EV can be considered as a variable load. With optimal charging or smart charging for the battery, vehicle owners could maximize their profits by purchasing energy, G2V (Grid to Vehicle), at the lowest possible electricity price and in on the other hand, battery of the EV canal so be considered as energy storage capacity which has possibility to provide energy V2G (Vehicle to Grid). After the simulations performed by applying this strategy to coordinate EV charging, we achieved a cost reduction with 20% from the initial cost.
- 1 October 2012
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 2942-2948
Dynamic programming for optimal integration of Plug-in Hybrid Electric Vehicles (PHEVs) in residential electric grid areas
Plug-in Hybrid Electric Vehicles (PHEVs) will strongly penetrate in the car fleet. Based on databases of the houses Daily Loads Profiles (DLPs) and on a probabilistic algorithm of PHEVs connections in residential electric grid areas, this paper determines the minimal charging current or PHEVs charging power which assures that the batteries reached the desired State of Charge (SOC) at the departure time without any charging restriction during peak hours. A dynamic optimization algorithm programming which defines an optimal constant charging current for the PHEV is developed. If charging occurs at home, the application of the proposed optimal algorithm on 10 000 cases shows statistically that a load power chargers for PHEVs charged in residential electric grid areas equals to 373W (230V×1.62A) ensures that 99.4% of the PHEVs batteries have a SOC equals to 100% for the next use.
- 1 October 2012
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 2942-2948
Dynamic programming for optimal integration of Plug-in Hybrid Electric Vehicles (PHEVs) in residential electric grid areas
Plug-in Hybrid Electric Vehicles (PHEVs) will strongly penetrate in the car fleet. Based on databases of the houses Daily Loads Profiles (DLPs) and on a probabilistic algorithm of PHEVs connections in residential electric grid areas, this paper determines the minimal charging current or PHEVs charging power which assures that the batteries reached the desired State of Charge (SOC) at the departure time without any charging restriction during peak hours. A dynamic optimization algorithm programming which defines an optimal constant charging current for the PHEV is developed. If charging occurs at home, the application of the proposed optimal algorithm on 10 000 cases shows statistically that a load power chargers for PHEVs charged in residential electric grid areas equals to 373W (230V×1.62A) ensures that 99.4% of the PHEVs batteries have a SOC equals to 100% for the next use.
- 1 September 2011
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 19388756,p. 1-8
Load rates of low voltage transformers and medium voltage profile assessments on a real distribution electric grid based on average Daily Load Profile (DLP) of a housing for a high penetration of plug-in hybrid electric vehicles (PHEVs)
This paper assesses the impact of PHEVs on a real medium voltage distribution electric grid based on average Daily Loads Profiles (DLPs) of a PHEV and of a housing. For three penetration rates, we show the important effects on load rates of low voltage transformers which compose the studied urban substation. Nevertheless, we demonstrate the robustness of medium voltage electric grid for the high penetration of PHEVs because the ηV index proposed which assess the quality of the voltage supplied to low voltage transformers reached a minimum of 98.2%.
- 1 September 2011
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 19388756,p. 1-8
Load rates of low voltage transformers and medium voltage profile assessments on a real distribution electric grid based on average Daily Load Profile (DLP) of a housing for a high penetration of plug-in hybrid electric vehicles (PHEVs)
This paper assesses the impact of PHEVs on a real medium voltage distribution electric grid based on average Daily Loads Profiles (DLPs) of a PHEV and of a housing. For three penetration rates, we show the important effects on load rates of low voltage transformers which compose the studied urban substation. Nevertheless, we demonstrate the robustness of medium voltage electric grid for the high penetration of PHEVs because the ηV index proposed which assess the quality of the voltage supplied to low voltage transformers reached a minimum of 98.2%.