André Farrokh
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
André Farrokh has a total of 17 co-authors. Here are the top co-authors by number of shared publications:
Nicolai Maass
Department of Gynecology and Obstetrics, University-Hospital Schleswig-Holstein Campus Kiel, Germany
4 shared publicationsFriedrich Degenhardt
Hannover Medical School, Department of Gynecology and Obstetrics, Hannover, Germany
2 shared publications- Friedrich Degenhardt
Department for Obstetrics and Gynecology, Franziskus Hospital Bielefeld, Bielefeld, Germany
2 shared publications Fritz Kw Schäfer
Department of Breast Imaging and Interventions, University-Hospital Schleswig-Holstein Campus Kiel, Germany
2 shared publicationsLinn Treu
Department of Gynecology and Obstetrics, Imland-Klinik Rendsburg, Germany
2 shared publications- Peter Hillemanns
Hannover Medical School, Hannover, Germany
2 shared publications
Latest Publications
- 20 August 2018
- Published by Georg Thieme Verlag KG in Ultraschall in der Medizin - European Journal of Ultrasound
- Vol. 40 (02) , 212-220
A Prospective Two Center Study Comparing Breast Cancer Lesion Size Defined by 2D Shear Wave Elastography, B-Mode Ultrasound, and Mammography with the Histopathological Size
Purpose The aim of the present study was to determine the accuracy of breast cancer measurement with 2 D shear wave elastography (2 D SWE), B-mode ultrasound, and mammography by comparing these methods with the actual histopathological tumor size. Materials and Methods 135 patients with proven malignant breast lesions at two centers were included in a prospective study. The maximum lesion diameter was measured by 2 D SWE, B-mode ultrasound, and mammography. After surgery, the histopathological tumor size was measured by a pathologist. Results The mean difference in tumor size on 2 D SWE, B-mode ultrasound, and mammography on the one hand, and the actual tumor size on the other, was –0.03 cm, 0.16 cm and 0.10 cm, respectively. Lesion size on histopathological investigation was overestimated by 2 D SWE (p = 0.004) and underestimated by B-mode imaging (p < 0.001). All three imaging methods underestimated the size of invasive lobular cancers and lesions > 15 mm; 2 D SWE was most accurate in this regard. Conclusion 2 D SWE predicted lesion size more precisely than B-mode ultrasound or mammography. In cases of invasive lobular carcinoma, all three imaging methods underestimated lesion size, with 2 D SWE coming closest to the actual tumor size.
- 20 August 2018
- Published by Georg Thieme Verlag KG in Ultraschall in der Medizin - European Journal of Ultrasound
- Vol. 40 (02) , 212-220
A Prospective Two Center Study Comparing Breast Cancer Lesion Size Defined by 2D Shear Wave Elastography, B-Mode Ultrasound, and Mammography with the Histopathological Size
Purpose The aim of the present study was to determine the accuracy of breast cancer measurement with 2 D shear wave elastography (2 D SWE), B-mode ultrasound, and mammography by comparing these methods with the actual histopathological tumor size. Materials and Methods 135 patients with proven malignant breast lesions at two centers were included in a prospective study. The maximum lesion diameter was measured by 2 D SWE, B-mode ultrasound, and mammography. After surgery, the histopathological tumor size was measured by a pathologist. Results The mean difference in tumor size on 2 D SWE, B-mode ultrasound, and mammography on the one hand, and the actual tumor size on the other, was –0.03 cm, 0.16 cm and 0.10 cm, respectively. Lesion size on histopathological investigation was overestimated by 2 D SWE (p = 0.004) and underestimated by B-mode imaging (p < 0.001). All three imaging methods underestimated the size of invasive lobular cancers and lesions > 15 mm; 2 D SWE was most accurate in this regard. Conclusion 2 D SWE predicted lesion size more precisely than B-mode ultrasound or mammography. In cases of invasive lobular carcinoma, all three imaging methods underestimated lesion size, with 2 D SWE coming closest to the actual tumor size.
- 25 July 2018
- Published by SAGE Publications in Acta Radiologica
- Vol. 60 (4) , 451-458
Accuracy of tumor size measurement: comparison of B-mode ultrasound, strain elastography, and 2D and 3D shear wave elastography with histopathological lesion size
Predicting the exact extent of a breast tumor is of great importance for oncologic treatment strategies. Different types of elastography can be used as new tools for measuring lesion size. To provide evidence regarding the accuracy of tumor size measurement of strain elastography (SE), two-dimensional (2D) and three-dimensional (3D) shear wave elastography (SWE), and conventional B-image ultrasound. In this prospective study, the diameter of 105 malignant breast lesions was measured by SE, 2D and 3D SWE, and B-mode ultrasound. The histopathological lesion size was compared to all imaging-based measuring methods. The mean lesion size of all breast carcinomas was 1.54 cm. B-mode ultrasound underestimates breast cancer size in 65.7 % of all cases in this study (P < 0.0001). Mean lesion size was more accurately determined by SE, 2D and 3D SWE compared to B-mode ultrasound. Absolute differences between measured and actual lesion are smaller for B-mode ultrasound (0.26 cm) than for SE (0.41 cm) and 2D and 3D SWE (0.41 cm and 0.44 cm, respectively). B-mode ultrasound allows more accurate lesion size measurement than SE and 2D or 3D SWE but has a significantly higher risk of underestimating tumor size which could lead to incomplete margins during surgery. 3D SWE was not superior to 2D SWE or SE but by trend more precise in predicting the size of invasive lobular carcinoma.
- 25 July 2018
- Published by SAGE Publications in Acta Radiologica
- Vol. 60 (4) , 451-458
Accuracy of tumor size measurement: comparison of B-mode ultrasound, strain elastography, and 2D and 3D shear wave elastography with histopathological lesion size
Predicting the exact extent of a breast tumor is of great importance for oncologic treatment strategies. Different types of elastography can be used as new tools for measuring lesion size. To provide evidence regarding the accuracy of tumor size measurement of strain elastography (SE), two-dimensional (2D) and three-dimensional (3D) shear wave elastography (SWE), and conventional B-image ultrasound. In this prospective study, the diameter of 105 malignant breast lesions was measured by SE, 2D and 3D SWE, and B-mode ultrasound. The histopathological lesion size was compared to all imaging-based measuring methods. The mean lesion size of all breast carcinomas was 1.54 cm. B-mode ultrasound underestimates breast cancer size in 65.7 % of all cases in this study (P < 0.0001). Mean lesion size was more accurately determined by SE, 2D and 3D SWE compared to B-mode ultrasound. Absolute differences between measured and actual lesion are smaller for B-mode ultrasound (0.26 cm) than for SE (0.41 cm) and 2D and 3D SWE (0.41 cm and 0.44 cm, respectively). B-mode ultrasound allows more accurate lesion size measurement than SE and 2D or 3D SWE but has a significantly higher risk of underestimating tumor size which could lead to incomplete margins during surgery. 3D SWE was not superior to 2D SWE or SE but by trend more precise in predicting the size of invasive lobular carcinoma.
- Open Access
- 11 April 2018
- Published by Georg Thieme Verlag KG in Geburtshilfe und Frauenheilkunde
- Vol. 78 (05) , 499-505
SOFIA: A Novel Automated Breast Ultrasound System Used on Patients in the Prone Position: A Pilot Study on Lesion Detection in Comparison to Handheld Grayscale Ultrasound
Introduction Most of the currently available automated breast ultrasound systems require patients to be in the supine position. Previous data, however, show a high recall rate with this method due to artifacts. The novel automated breast ultrasound scanner SOFIA scans the breast with the patient in a prone position, resulting in even compression of breast tissue. We present our initial results with this examination method. Material and Methods 63 patients were analyzed using a handheld B-mode ultrasound. In cases of BI-RADS 1, 2 or 5, a SOFIA scan was performed. Sensitivity, specificity and accuracy were calculated. Interobserver agreement was evaluated using Cohenʼs kappa. The duration of the scan was measured for both methods. Results No BI-RADS 5 lesion was missed with SOFIA. The SOFIA had an additional recall rate of 16.67% compared to B-mode ultrasound. The sensitivity, specificity and accuracy of SOFIA was 100, 83.33 and 88.89%, respectively. Cohenʼs kappa showed substantial agreement (κ = 0.769) between examiner 1 (B-mode) and examiner 2 (SOFIA). The mean scan duration for the B-mode system and the SOFIA system was 24.21 minutes and 12.94 minutes, respectively. In four cases, D-cup breasts were not scanned in their entirety. Conclusion No cancer was missed when SOFIA was used in this preselected study population. The scanning time was approximately half of that required for B-mode ultrasound. The additional unnecessary recall rate was 16.67%. Larger D cup-size breasts were difficult to position and resulted in an incomplete image in four cases.
- 11 April 2018
- Published by Georg Thieme Verlag KG in Geburtshilfe und Frauenheilkunde
- Vol. 78 (05) , 499-505
Open AccessSOFIA: A Novel Automated Breast Ultrasound System Used on Patients in the Prone Position: A Pilot Study on Lesion Detection in Comparison to Handheld Grayscale Ultrasound
Introduction Most of the currently available automated breast ultrasound systems require patients to be in the supine position. Previous data, however, show a high recall rate with this method due to artifacts. The novel automated breast ultrasound scanner SOFIA scans the breast with the patient in a prone position, resulting in even compression of breast tissue. We present our initial results with this examination method. Material and Methods 63 patients were analyzed using a handheld B-mode ultrasound. In cases of BI-RADS 1, 2 or 5, a SOFIA scan was performed. Sensitivity, specificity and accuracy were calculated. Interobserver agreement was evaluated using Cohenʼs kappa. The duration of the scan was measured for both methods. Results No BI-RADS 5 lesion was missed with SOFIA. The SOFIA had an additional recall rate of 16.67% compared to B-mode ultrasound. The sensitivity, specificity and accuracy of SOFIA was 100, 83.33 and 88.89%, respectively. Cohenʼs kappa showed substantial agreement (κ = 0.769) between examiner 1 (B-mode) and examiner 2 (SOFIA). The mean scan duration for the B-mode system and the SOFIA system was 24.21 minutes and 12.94 minutes, respectively. In four cases, D-cup breasts were not scanned in their entirety. Conclusion No cancer was missed when SOFIA was used in this preselected study population. The scanning time was approximately half of that required for B-mode ultrasound. The additional unnecessary recall rate was 16.67%. Larger D cup-size breasts were difficult to position and resulted in an incomplete image in four cases.
- 21 February 2018
- Published by Elsevier in Ultrasound in Medicine & Biology
- Vol. 44 (5) , 978-985
Comparison of Two Different Ultrasound Devices Using Strain Elastography Technology in the Diagnosis of Breast Lesions Related to the Histologic Results
- 21 February 2018
- Published by Elsevier in Ultrasound in Medicine & Biology
- Vol. 44 (5) , 978-985
Comparison of Two Different Ultrasound Devices Using Strain Elastography Technology in the Diagnosis of Breast Lesions Related to the Histologic Results
- Open Access
- 12 November 2013
- Published by Springer Nature in BMC Medical Imaging
- Vol. 13 (1) , 36
Diagnostic performance and inter-observer concordance in lesion detection with the automated breast volume scanner (ABVS)
Automated whole breast ultrasound scanners of the latest generation have reached a level of comfortable application and high quality volume acquisition. Nevertheless, there is a lack of data concerning this technology. We investigated the diagnostic performance and inter-observer concordance of the Automated Breast Volume Scanner (ABVS) ACUSON S2000™ and questioned its implications in breast cancer diagnostics.
- 12 November 2013
- Published by Springer Nature in BMC Medical Imaging
- Vol. 13 (1) , 36
Open AccessDiagnostic performance and inter-observer concordance in lesion detection with the automated breast volume scanner (ABVS)
Automated whole breast ultrasound scanners of the latest generation have reached a level of comfortable application and high quality volume acquisition. Nevertheless, there is a lack of data concerning this technology. We investigated the diagnostic performance and inter-observer concordance of the Automated Breast Volume Scanner (ABVS) ACUSON S2000™ and questioned its implications in breast cancer diagnostics.
- Open Access
- 27 March 2013
- Published by Springer Nature in BMC Cancer
- Vol. 13 (1) , 159
Ultrasound real-time elastography can predict malignancy in BI-RADS®-US 3 lesions
Lesions of the breast that are classified BI-RADS®-US 3 by ultrasound are probably benign and observation is recommended, although malignancy may occasionally occur.
- 27 March 2013
- Published by Springer Nature in BMC Cancer
- Vol. 13 (1) , 159
Open AccessUltrasound real-time elastography can predict malignancy in BI-RADS®-US 3 lesions
Lesions of the breast that are classified BI-RADS®-US 3 by ultrasound are probably benign and observation is recommended, although malignancy may occasionally occur.