Karen C. Peebles
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Karen C. Peebles has a total of 96 co-authors. Here are the top co-authors by number of shared publications:
- Kate Nicole Thomas
University of Otago
10 shared publications - Samuel John Edwin Lucas
School of Sport, Exercise and Rehabilitation Sciences University of Birmingham Birmingham UK
9 shared publications - Jui-Lin Fan
University of Auckland
7 shared publications Keith R. Burgess
Univ Sydney, Dept Med, Sydney, NSW 2006, Australia
7 shared publications- Rebekah Ann Isabel Lucas
School of Sport, Exercise and Rehabilitation Sciences University of Birmingham Birmingham UK
7 shared publications James D. Cotter
Univ Otago, Sch Phys Educ, Dunedin, New Zealand
6 shared publications
Latest Publications
- Open Access
- 13 February 2024
- Published by Elsevier in Autonomic Neuroscience
- Vol. 252, 103156
The use and effectiveness of exercise for managing postural orthostatic tachycardia syndrome in young adults with joint hypermobility and related conditions: A scoping review
- 13 February 2024
- Published by Elsevier in Autonomic Neuroscience
- Vol. 252, 103156
Open AccessThe use and effectiveness of exercise for managing postural orthostatic tachycardia syndrome in young adults with joint hypermobility and related conditions: A scoping review
- Open Access
- 1 December 2022
- Published by American Physiological Society in Journal of Applied Physiology
- Vol. 133 (6) , 1318-1326
Inspiratory muscle reflex control after incomplete cervical spinal cord injury
Individuals with incomplete cSCI were tested for the presence of a short latency reflex inhibition of inspiratory muscles, by brief airway occlusion. The reflex was 4.5 times more prevalent in this group compared with those with complete cSCI and is similar to the incidence in able-bodied people. Participants without this reflex all had untreated severe OSA, in contrast to those with an IR, who either had no, mild, or treated OSA. This work reveals novel differences in the reflex control of inspiratory muscles across the cSCI population.
- 1 December 2022
- Published by American Physiological Society in Journal of Applied Physiology
- Vol. 133 (6) , 1318-1326
Open AccessInspiratory muscle reflex control after incomplete cervical spinal cord injury
Individuals with incomplete cSCI were tested for the presence of a short latency reflex inhibition of inspiratory muscles, by brief airway occlusion. The reflex was 4.5 times more prevalent in this group compared with those with complete cSCI and is similar to the incidence in able-bodied people. Participants without this reflex all had untreated severe OSA, in contrast to those with an IR, who either had no, mild, or treated OSA. This work reveals novel differences in the reflex control of inspiratory muscles across the cSCI population.
- Open Access
- 27 February 2022
- Published by Wiley in American Journal of Medical Genetics Part A
- Vol. 188 (6) , 1761-1776
The prevalence and impact of orthostatic intolerance in young women across the hypermobility spectrum
Orthostatic intolerance (OI) is frequently reported in young women with generalized hypermobility spectrum disorder (G‐HSD) and hypermobile EDS (hEDS). However, it remains currently unclear whether OI is a comorbidity or fundamental part of the pathophysiology of G‐HSD or hEDS. This study investigated the prevalence and impact of OI in young women across the hypermobility spectrum. Forty‐five women (14–30 years, 15 controls, 15 G‐HSD, and 15 hEDS) undertook a head‐up tilt (HUT) and active stand test. Postural Orthostatic Tachycardia Syndrome (POTS) and Orthostatic Hypotension (OH) were assessed using age‐related criteria. Autonomic dysfunction and quality‐of‐life questionnaires were also completed. The prevalence of POTS was higher in women with G‐HSD than hEDS and control groups during HUT (43% vs. 7% and 7%, respectively, p < 0.05), but similar between groups during the active stand (47%, 27%, and 13% for G‐HSD, hEDS, and control, respectively). No participants had OH. hEDS and G‐HSD participants reported more severe orthostatic symptoms and poorer quality of life than controls. Although POTS was observed in hypermobile participants, there is no conclusive evidence that its prevalence differed between groups due to differences between the HUT and active stand assessments. Nevertheless, OI and broader autonomic dysfunction impacted on their quality of life.
- 27 February 2022
- Published by Wiley in American Journal of Medical Genetics Part A
- Vol. 188 (6) , 1761-1776
Open AccessThe prevalence and impact of orthostatic intolerance in young women across the hypermobility spectrum
Orthostatic intolerance (OI) is frequently reported in young women with generalized hypermobility spectrum disorder (G‐HSD) and hypermobile EDS (hEDS). However, it remains currently unclear whether OI is a comorbidity or fundamental part of the pathophysiology of G‐HSD or hEDS. This study investigated the prevalence and impact of OI in young women across the hypermobility spectrum. Forty‐five women (14–30 years, 15 controls, 15 G‐HSD, and 15 hEDS) undertook a head‐up tilt (HUT) and active stand test. Postural Orthostatic Tachycardia Syndrome (POTS) and Orthostatic Hypotension (OH) were assessed using age‐related criteria. Autonomic dysfunction and quality‐of‐life questionnaires were also completed. The prevalence of POTS was higher in women with G‐HSD than hEDS and control groups during HUT (43% vs. 7% and 7%, respectively, p < 0.05), but similar between groups during the active stand (47%, 27%, and 13% for G‐HSD, hEDS, and control, respectively). No participants had OH. hEDS and G‐HSD participants reported more severe orthostatic symptoms and poorer quality of life than controls. Although POTS was observed in hypermobile participants, there is no conclusive evidence that its prevalence differed between groups due to differences between the HUT and active stand assessments. Nevertheless, OI and broader autonomic dysfunction impacted on their quality of life.
- 6 May 2020
- Published by Springer Nature in Breast Cancer Research and Treatment
- Vol. 181 (3) , 635-644
Assessing breast lymphoedema following breast cancer treatment using indocyanine green lymphography
Purpose Breast lymphoedema is a largely unrecognised survivorship issue for women following breast cancer treatment. While a few objective methods have previously been applied to assess breast lymphoedema, none are capable of imaging breast lymphatics or identifying lymphatic morphological changes indicative of breast lymphoedema. The purpose of this study was to determine if indocyanine green (ICG) lymphography, a validated assessment technique in breast cancer-related lymphoedema), can visualise breast lymphatics and identify breast lymphoedema. Additionally, ICG lymphography was utilised to investigate lymphatic drainage pathways of the affected breast following breast-conserving therapy. Methods Twenty female participants (10 breast lymphoedema and 10 healthy controls) were recruited for this pilot study. All underwent a medical history, physical breast assessment, tissue dielectric constant measures of breast water content, and ICG lymphography. Results ICG lymphography identified lymphatic morphological changes in all breast lymphoedema participants (dermal backflow patterns = 10, collateral lymphatic drainage = 9) and none in the control group. The dominant lymphatic drainage pathway to the ipsilateral axilla was observed in all control participants but in only four breast lymphoedema participants. Collateral drainage pathways in the breast lymphoedema group were to: parasternal (6/10); contralateral axilla (4/10); intercostal (3/10); and clavicular (2/10) regions. Conclusion These findings suggest ICG lymphography, through the identification of morphological lymphatic changes, is a potential qualitative objective assessment technique for breast lymphoedema. Furthermore, in this group of breast lymphoedema patients it identified changes to the normal drainage pathway of the breast. Understanding these changes will have implications for clinical management.
- 6 May 2020
- Published by Springer Nature in Breast Cancer Research and Treatment
- Vol. 181 (3) , 635-644
Assessing breast lymphoedema following breast cancer treatment using indocyanine green lymphography
Purpose Breast lymphoedema is a largely unrecognised survivorship issue for women following breast cancer treatment. While a few objective methods have previously been applied to assess breast lymphoedema, none are capable of imaging breast lymphatics or identifying lymphatic morphological changes indicative of breast lymphoedema. The purpose of this study was to determine if indocyanine green (ICG) lymphography, a validated assessment technique in breast cancer-related lymphoedema), can visualise breast lymphatics and identify breast lymphoedema. Additionally, ICG lymphography was utilised to investigate lymphatic drainage pathways of the affected breast following breast-conserving therapy. Methods Twenty female participants (10 breast lymphoedema and 10 healthy controls) were recruited for this pilot study. All underwent a medical history, physical breast assessment, tissue dielectric constant measures of breast water content, and ICG lymphography. Results ICG lymphography identified lymphatic morphological changes in all breast lymphoedema participants (dermal backflow patterns = 10, collateral lymphatic drainage = 9) and none in the control group. The dominant lymphatic drainage pathway to the ipsilateral axilla was observed in all control participants but in only four breast lymphoedema participants. Collateral drainage pathways in the breast lymphoedema group were to: parasternal (6/10); contralateral axilla (4/10); intercostal (3/10); and clavicular (2/10) regions. Conclusion These findings suggest ICG lymphography, through the identification of morphological lymphatic changes, is a potential qualitative objective assessment technique for breast lymphoedema. Furthermore, in this group of breast lymphoedema patients it identified changes to the normal drainage pathway of the breast. Understanding these changes will have implications for clinical management.
- Open Access
- 11 February 2020
- Published by Springer Nature in Artery Research
- Vol. 26 (2) , 89-96
Interarm Differences in Brachial Blood Pressure and their Effect on the Derivation on Central Aortic Blood Pressure
Background: Inter-arm differences in brachial systolic Blood Pressure (BP) are associated with increased cardiovascular risk. It is unclear whether anatomical factors contribute to brachial Interarm Blood Pressure (IABP) differences or whether brachial IABP differences translate to differences in derived central aortic BP. This study aimed to ascertain whether IABP differences in brachial BP correlate with anatomical factors (arm side, dominance, and geometry) and translate to differences in derived central BP. Methods: Brachial BP and derived central BP were measured simultaneously in both arms in 77 community-dwelling adults (18–66 years, 38 male) using two SphygmoCor XCEL (AtCor Medical) BP devices. Measurements were taken 3–4 times in each participant, swapping devices between measurements. An optoelectronic volumeter (Perometer 350S) and hand-held dynamometer (Saehan) were used to measure arm volume and maximal hand-grip strength. Differences in brachial and derived central BP between arms were evaluated by paired t-tests. Regression analysis was used to examine predictors of IABP differences. Results: Absolute IABP difference in brachial systolic BP was 4.2 ± 3.6 mmHg. Brachial systolic IABP differences were not different between arms (right/left, dominant/non-dominant, or large/small arm volume). Brachial systolic IABP differences were not correlated with differences in arm volume or grip strength. Male sex and diastolic BP were the only predictors. Brachial systolic IABP difference translated to a small (3.1 ± 2.4 mmHg) difference in derived central BP. Conclusion: As there is only a single aortic BP, we consider the difference in derived central BP likely an artefact. The possibility that it results from BP variability warrants further investigation.
- 11 February 2020
- Published by Springer Nature in Artery Research
- Vol. 26 (2) , 89-96
Open AccessInterarm Differences in Brachial Blood Pressure and their Effect on the Derivation on Central Aortic Blood Pressure
Background: Inter-arm differences in brachial systolic Blood Pressure (BP) are associated with increased cardiovascular risk. It is unclear whether anatomical factors contribute to brachial Interarm Blood Pressure (IABP) differences or whether brachial IABP differences translate to differences in derived central aortic BP. This study aimed to ascertain whether IABP differences in brachial BP correlate with anatomical factors (arm side, dominance, and geometry) and translate to differences in derived central BP. Methods: Brachial BP and derived central BP were measured simultaneously in both arms in 77 community-dwelling adults (18–66 years, 38 male) using two SphygmoCor XCEL (AtCor Medical) BP devices. Measurements were taken 3–4 times in each participant, swapping devices between measurements. An optoelectronic volumeter (Perometer 350S) and hand-held dynamometer (Saehan) were used to measure arm volume and maximal hand-grip strength. Differences in brachial and derived central BP between arms were evaluated by paired t-tests. Regression analysis was used to examine predictors of IABP differences. Results: Absolute IABP difference in brachial systolic BP was 4.2 ± 3.6 mmHg. Brachial systolic IABP differences were not different between arms (right/left, dominant/non-dominant, or large/small arm volume). Brachial systolic IABP differences were not correlated with differences in arm volume or grip strength. Male sex and diastolic BP were the only predictors. Brachial systolic IABP difference translated to a small (3.1 ± 2.4 mmHg) difference in derived central BP. Conclusion: As there is only a single aortic BP, we consider the difference in derived central BP likely an artefact. The possibility that it results from BP variability warrants further investigation.
- 25 May 2018
- Published by BMJ in Archives of Disease in Childhood
- Vol. 104 (8) , 806-808
Distress during airway sampling in children with cystic fibrosis
Background Oropharyngeal suction and oropharyngeal swab are two methods of obtaining airway samples with similar diagnostic accuracy in children with cystic fibrosis (CF). The primary aim was comparing distress between suctioning and swabbing. A secondary aim was establishing the reliability of the Groningen Distress Rating Scale (GDRS). Methods Randomised oropharyngeal suction or swab occurred over two visits. Two physiotherapists and the child’s parent rated distress using the GDRS. Heart rate (HR) was also measured. Results 24 children with CF, mean age of 3 years, participated. Both physiotherapist and parent rating showed significantly higher distress levels during suction than swab. Inter-rater reliability for the GDRS was very good between physiotherapists, and good between physiotherapist and parents. Conclusion The study found that oropharyngeal swab is less distressing in obtaining samples than oropharyngeal suction and that the GDRS was reliable and valid.
- 25 May 2018
- Published by BMJ in Archives of Disease in Childhood
- Vol. 104 (8) , 806-808
Distress during airway sampling in children with cystic fibrosis
Background Oropharyngeal suction and oropharyngeal swab are two methods of obtaining airway samples with similar diagnostic accuracy in children with cystic fibrosis (CF). The primary aim was comparing distress between suctioning and swabbing. A secondary aim was establishing the reliability of the Groningen Distress Rating Scale (GDRS). Methods Randomised oropharyngeal suction or swab occurred over two visits. Two physiotherapists and the child’s parent rated distress using the GDRS. Heart rate (HR) was also measured. Results 24 children with CF, mean age of 3 years, participated. Both physiotherapist and parent rating showed significantly higher distress levels during suction than swab. Inter-rater reliability for the GDRS was very good between physiotherapists, and good between physiotherapist and parents. Conclusion The study found that oropharyngeal swab is less distressing in obtaining samples than oropharyngeal suction and that the GDRS was reliable and valid.
- Open Access
- 18 April 2017
- Published by Wiley in Physiological Reports
- Vol. 5 (8) , e13248
Resting heart rate variability and exercise capacity in Type 1 diabetes
People with type 1 diabetes (T1D) have lower exercise capacity (V̇O2max) than their age‐matched nondiabetic counterparts (CON), which might be related to cardiac autonomic dysfunction. We examined whether Heart Rate Variability (HRV; indicator of cardiac autonomic modulation) was associated with exercise capacity in those with and without T1D. Twenty‐three participants with uncomplicated T1D and 17 matched CON were recruited. Heart rate (HR; ECG), blood pressure (BP; finger photo‐plethysmography), and respiratory rate (respiratory belt) were measured during baseline, paced‐breathing and clinical autonomic reflex tests (CARTs); deep breathing, lying‐to‐stand, and Valsalva maneuver. Baseline and paced‐breathing ECG were analyzed for HRV (frequency‐domain). Exercise capacity was determined during an incremental cycle ergometer test while V̇O2, 12‐lead ECG, and BP were measured. In uncomplicated T1D, resting HR was elevated and resting HRV metrics were reduced, indicative of altered cardiac parasympathetic modulation; this was generally undetected by the CARTs. However, BP and plasma catecholamines were not different between groups. In T1D, V̇O2max tended to be lower (P = 0.07) and HR reserve was lower (P < 0.01). Resting Total Power (TP) had stronger positive associations with V̇O2max (R 2 ≥ 0.3) than all other traditional indicators such as age, resting HR, and self‐reported exercise (R 2 = 0.042–0.3) in both T1D and CON. Alterations in cardiac autonomic modulation are an early manifestation of uncomplicated T1D. Total Power was associated with reduced exercise capacity regardless of group, and these associations were generally stronger than traditional indicators.
- 18 April 2017
- Published by Wiley in Physiological Reports
- Vol. 5 (8) , e13248
Open AccessResting heart rate variability and exercise capacity in Type 1 diabetes
People with type 1 diabetes (T1D) have lower exercise capacity (V̇O2max) than their age‐matched nondiabetic counterparts (CON), which might be related to cardiac autonomic dysfunction. We examined whether Heart Rate Variability (HRV; indicator of cardiac autonomic modulation) was associated with exercise capacity in those with and without T1D. Twenty‐three participants with uncomplicated T1D and 17 matched CON were recruited. Heart rate (HR; ECG), blood pressure (BP; finger photo‐plethysmography), and respiratory rate (respiratory belt) were measured during baseline, paced‐breathing and clinical autonomic reflex tests (CARTs); deep breathing, lying‐to‐stand, and Valsalva maneuver. Baseline and paced‐breathing ECG were analyzed for HRV (frequency‐domain). Exercise capacity was determined during an incremental cycle ergometer test while V̇O2, 12‐lead ECG, and BP were measured. In uncomplicated T1D, resting HR was elevated and resting HRV metrics were reduced, indicative of altered cardiac parasympathetic modulation; this was generally undetected by the CARTs. However, BP and plasma catecholamines were not different between groups. In T1D, V̇O2max tended to be lower (P = 0.07) and HR reserve was lower (P < 0.01). Resting Total Power (TP) had stronger positive associations with V̇O2max (R 2 ≥ 0.3) than all other traditional indicators such as age, resting HR, and self‐reported exercise (R 2 = 0.042–0.3) in both T1D and CON. Alterations in cardiac autonomic modulation are an early manifestation of uncomplicated T1D. Total Power was associated with reduced exercise capacity regardless of group, and these associations were generally stronger than traditional indicators.
- 1 September 2016
- Published by Wolters Kluwer Health in Journal Of Hypertension
- Vol. 34 (Supplement) , e208
OS 13-01 BRACHIAL AND CALCULATED AORTIC BLOOD PRESSURE DIFFERENCES WHEN MEASURED FROM THE DOMINANT AND NON-DOMINANT ARM
Inter-arm systolic blood pressure (IASBP) differences ≥10 mmHg are associated with increased cardiovascular risk. Prevalence of IASBP differences is unclear given that studies are mainly in diseased populations and vary in measurement technique (sequential vs simultaneous recording). Moreover, no studies have determined whether dominant or non-dominant arm influences calculated central aortic blood pressure. The purpose of this study was to examine the prevalence of IASBP differences measured at the brachial artery and calculated at the aorta in community dwelling adults. In 76 healthy subjects (34 ± 14 years, 37 male) following at least 5 minutes rest, blood pressure and brachial volumetric displacement waveform were simultaneously recorded in the left and right arm using two identical SphygmoCor XCEL (AtCor Medical) blood pressure devices. Measurements were taken four times in each subject, swapping the devices between arms for each measurement. Within arm brachial systolic and diastolic pressure outliers (interquartile range rule) were removed and repeated measures pairwise analysis conducted. Brachial systolic pressure significantly higher in one arm in 10 of the 76 subjects (13%, average IASBP difference 5.0 ± 0.2 mmHg), of which 5 had higher pressure in the dominant arm. Across all subjects, brachial IASBP difference was 3.2 ± 0.3 mmHg (p < 0.001), of which 1.0 ± 0.5 mmHg (p = 0.050) was accounted by arm dominance. Calculated central systolic pressure was different by 2.1 ± 0.3 mmHg (p < 0.01) but not affected by arm dominance (p = 0.291). Left and right arm differences followed a similar trend (data not shown). Mean pressure differences followed systolic pressure whilst aortic augmentation index (AIx) showed an inter-arm difference, but was not higher in the arm of highest brachial systolic pressure (Table). Dominant/non-dominant arm differences exist for brachial systolic blood pressure (13% of the cohort) but do not influence calculated central aortic blood pressure. However, IASBP differences are largely not related to arm dominance.
- 1 September 2016
- Published by Wolters Kluwer Health in Journal Of Hypertension
- Vol. 34 (Supplement) , e208
OS 13-01 BRACHIAL AND CALCULATED AORTIC BLOOD PRESSURE DIFFERENCES WHEN MEASURED FROM THE DOMINANT AND NON-DOMINANT ARM
Inter-arm systolic blood pressure (IASBP) differences ≥10 mmHg are associated with increased cardiovascular risk. Prevalence of IASBP differences is unclear given that studies are mainly in diseased populations and vary in measurement technique (sequential vs simultaneous recording). Moreover, no studies have determined whether dominant or non-dominant arm influences calculated central aortic blood pressure. The purpose of this study was to examine the prevalence of IASBP differences measured at the brachial artery and calculated at the aorta in community dwelling adults. In 76 healthy subjects (34 ± 14 years, 37 male) following at least 5 minutes rest, blood pressure and brachial volumetric displacement waveform were simultaneously recorded in the left and right arm using two identical SphygmoCor XCEL (AtCor Medical) blood pressure devices. Measurements were taken four times in each subject, swapping the devices between arms for each measurement. Within arm brachial systolic and diastolic pressure outliers (interquartile range rule) were removed and repeated measures pairwise analysis conducted. Brachial systolic pressure significantly higher in one arm in 10 of the 76 subjects (13%, average IASBP difference 5.0 ± 0.2 mmHg), of which 5 had higher pressure in the dominant arm. Across all subjects, brachial IASBP difference was 3.2 ± 0.3 mmHg (p < 0.001), of which 1.0 ± 0.5 mmHg (p = 0.050) was accounted by arm dominance. Calculated central systolic pressure was different by 2.1 ± 0.3 mmHg (p < 0.01) but not affected by arm dominance (p = 0.291). Left and right arm differences followed a similar trend (data not shown). Mean pressure differences followed systolic pressure whilst aortic augmentation index (AIx) showed an inter-arm difference, but was not higher in the arm of highest brachial systolic pressure (Table). Dominant/non-dominant arm differences exist for brachial systolic blood pressure (13% of the cohort) but do not influence calculated central aortic blood pressure. However, IASBP differences are largely not related to arm dominance.
- Open Access
- 1 October 2015
- Published by American Physiological Society in Journal of Applied Physiology
- Vol. 119 (7) , 793-798
Interactions between breathing rate and low-frequency fluctuations in blood pressure and cardiac intervals
Evidence derived from spontaneous measures of cardiovagal baroreflex sensitivity (BRS) suggests that slow breathing at 6 breaths min-1 augments BRS. However, increases in BRS associated with slow breathing may simply reflect the frequency-dependent nature of the baroreflex rather than the modulation of baroreflex function by changes in breathing rate per se. To test this hypothesis we employed a crossover study design (n=14) wherein breathing rate and systolic arterial blood pressure (SAP) oscillation induced via the application of oscillating lower body negative pressure (OLBNP), were independently varied at fixed frequencies. Breathing rate was controlled at 6 or 10 breaths min-1 with the aid of a metronome, and SAP oscillations were driven at 0.06 Hz and 0.1 Hz using OLBNP. The magnitudes of SAP and R-R interval (cardiac period) oscillations were quantified using power spectral analysis, and the transfer function gain between SAP and R-R interval was used to estimate BRS. Linear mixed-effects models were used to examine the main effects and interactions between breathing rate and OLBNP frequency. There was no statistical interaction between breathing and OLBNP frequency (p=0.59), indicating that the effect of breathing rate on BRS did not differ according to OLBNP frequency (and vice versa). Additionally, there was no main effect for breathing rate (p=0.28). However, we observed a significant main effect for OLBNP frequency (p=0.01) consistent with the frequency-dependent nature of baroreflex. These findings suggest that increases in spectral indices of BRS reflect the frequency-dependence of the baroreflex, and are not due to slow breathing per se.
- 1 October 2015
- Published by American Physiological Society in Journal of Applied Physiology
- Vol. 119 (7) , 793-798
Open AccessInteractions between breathing rate and low-frequency fluctuations in blood pressure and cardiac intervals
Evidence derived from spontaneous measures of cardiovagal baroreflex sensitivity (BRS) suggests that slow breathing at 6 breaths min-1 augments BRS. However, increases in BRS associated with slow breathing may simply reflect the frequency-dependent nature of the baroreflex rather than the modulation of baroreflex function by changes in breathing rate per se. To test this hypothesis we employed a crossover study design (n=14) wherein breathing rate and systolic arterial blood pressure (SAP) oscillation induced via the application of oscillating lower body negative pressure (OLBNP), were independently varied at fixed frequencies. Breathing rate was controlled at 6 or 10 breaths min-1 with the aid of a metronome, and SAP oscillations were driven at 0.06 Hz and 0.1 Hz using OLBNP. The magnitudes of SAP and R-R interval (cardiac period) oscillations were quantified using power spectral analysis, and the transfer function gain between SAP and R-R interval was used to estimate BRS. Linear mixed-effects models were used to examine the main effects and interactions between breathing rate and OLBNP frequency. There was no statistical interaction between breathing and OLBNP frequency (p=0.59), indicating that the effect of breathing rate on BRS did not differ according to OLBNP frequency (and vice versa). Additionally, there was no main effect for breathing rate (p=0.28). However, we observed a significant main effect for OLBNP frequency (p=0.01) consistent with the frequency-dependent nature of baroreflex. These findings suggest that increases in spectral indices of BRS reflect the frequency-dependence of the baroreflex, and are not due to slow breathing per se.
- 1 August 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 2015 (1094687X) , 5708-5711
A simplified method for quantifying the subject-specific relationship between blood pressure and carotid-femoral pulse wave velocity
Devices that estimate blood pressure from arterial pulse wave velocity (PWV) potentially provide continuous, ambulatory blood pressure monitoring. Accurate blood pressure estimation requires reliable quantification of the relationship between blood pressure and PWV. Regression to population normal values or, when using limb artery PWV, changing hydrostatic blood pressure within the limb provides a calibration index. Population lookup tables require accurate anthropometric correlates, assuming no individual variation. Only devices that measure PWV in the limb can use limb position changes. This study proposes a method for developing a calibration curve independent of lookup tables and useful for large artery PWV measurement, such as carotid-femoral PWV (PWV cf ). PWV cf was measured in 27 normal subjects (15 female, 36±19 years) in both the supine and standing position. The change in systemic pressure was measured and hydrostatic pressure change calculated from estimated vessel path length height, measured using body surface distances. Brachial diastolic blood pressure increased for all subjects from supine to standing (supine 70±8 mmHg, standing 83±8 mmHg, p<;0.001) with an additional hydrostatic change across the carotid-femoral path length of 19±2 mmHg (p<;0.001). PWV cf also increased in all subjects (supine 5.2±1.3 m/s, standing 7.3±2.2 m/s, p<;0.001). The subject-specific calibration index (ΔDP/ΔPWV cf ) varied amongst the cohort (20±8 mmHg/m/s), was correlated with age (-0.57, p=0.002) and seated aortic systolic pressure (-0.38, p=0.048) and was always greater than zero. Thus, this study describes a simple but novel method of measuring an individualized calibration index using blood pressure and PWV measurements in the supine and standing position.
- 1 August 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 2015 (1094687X) , 5708-5711
A simplified method for quantifying the subject-specific relationship between blood pressure and carotid-femoral pulse wave velocity
Devices that estimate blood pressure from arterial pulse wave velocity (PWV) potentially provide continuous, ambulatory blood pressure monitoring. Accurate blood pressure estimation requires reliable quantification of the relationship between blood pressure and PWV. Regression to population normal values or, when using limb artery PWV, changing hydrostatic blood pressure within the limb provides a calibration index. Population lookup tables require accurate anthropometric correlates, assuming no individual variation. Only devices that measure PWV in the limb can use limb position changes. This study proposes a method for developing a calibration curve independent of lookup tables and useful for large artery PWV measurement, such as carotid-femoral PWV (PWV cf ). PWV cf was measured in 27 normal subjects (15 female, 36±19 years) in both the supine and standing position. The change in systemic pressure was measured and hydrostatic pressure change calculated from estimated vessel path length height, measured using body surface distances. Brachial diastolic blood pressure increased for all subjects from supine to standing (supine 70±8 mmHg, standing 83±8 mmHg, p<;0.001) with an additional hydrostatic change across the carotid-femoral path length of 19±2 mmHg (p<;0.001). PWV cf also increased in all subjects (supine 5.2±1.3 m/s, standing 7.3±2.2 m/s, p<;0.001). The subject-specific calibration index (ΔDP/ΔPWV cf ) varied amongst the cohort (20±8 mmHg/m/s), was correlated with age (-0.57, p=0.002) and seated aortic systolic pressure (-0.38, p=0.048) and was always greater than zero. Thus, this study describes a simple but novel method of measuring an individualized calibration index using blood pressure and PWV measurements in the supine and standing position.