Łukasz Tymecki
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Łukasz Tymecki has a total of 44 co-authors. Here are the top co-authors by number of shared publications:
- Robert Koncki
University of Warsaw, Faculty of Chemistry, Pasteura 1, 02-093 Warsaw, Poland
37 shared publications Marta Pokrzywnicka
Department of Chemistry, University of Warsaw, Pasteura 1, 02-930 Warsaw, Poland
9 shared publications- Michał Michalec
University of Warsaw, Faculty of Chemistry, Pasteura 1, 02-093 Warsaw, Poland; University of Warsaw, MISMaP College, Banacha 2C, 02-097 Warsaw, Poland
7 shared publications - Kamil Strzelak
University of Warsaw, Faculty of Chemistry, Warsaw, Poland
6 shared publications Beata Rozum
Department of Chemistry, University of Warsaw, 02-093 Warsaw, Poland
4 shared publicationsElżbieta Zwierkowska
Institute of Electronic Materials Technology, Wolczynska 133, 01-919 Warsaw, Poland
4 shared publications
Latest Publications
- Open Access
- 27 June 2025
- Published by Elsevier in Sensors and Actuators B: Chemical
- Vol. 443
In situ biological samples deproteinization in microfluidic paper-based analytical devices
- 27 June 2025
- Published by Elsevier in Sensors and Actuators B: Chemical
- Vol. 443
Open AccessIn situ biological samples deproteinization in microfluidic paper-based analytical devices
- Open Access
- 26 July 2024
- Published by Elsevier in Analytica Chimica Acta
- Vol. 1320, 343028
Hydrogen peroxide stabilization with silica xerogel for paper-based analytical devices and its application to phenolic compounds determination
- 26 July 2024
- Published by Elsevier in Analytica Chimica Acta
- Vol. 1320, 343028
Open AccessHydrogen peroxide stabilization with silica xerogel for paper-based analytical devices and its application to phenolic compounds determination
- Open Access
- 20 April 2024
- Published by Elsevier in Analytica Chimica Acta
- Vol. 1308, 342639
Microfluidic paper-based analytical device for simultaneous determination of calcium and magnesium ions in human serum
- 20 April 2024
- Published by Elsevier in Analytica Chimica Acta
- Vol. 1308, 342639
Open AccessMicrofluidic paper-based analytical device for simultaneous determination of calcium and magnesium ions in human serum
- Open Access
Smartphone-Assisted Protein to Creatinine Ratio Determination on a Single Paper-Based Analytical Device
Proteinuria is a condition in which an excessive amount of protein is excreted in urine. It is, among others, an indicator of kidney disease or risk of cardiovascular disease. Rapid and reliable diagnosis and monitoring of proteinuria is of great importance for both patients and their physicians. For that reason, a paper-based sensor for proteinuria diagnosis was designed, optimized, and validated utilizing smartphone-assisted signal acquisition. In the first step, a few commonly employed protein assays were optimized and compared in terms of analytical performance on paper matrix. The tetrabromophenol blue method was selected as the one providing a sufficiently low limit of detection (39 mg·L−1) on the one hand and appropriate long-term stability (up to 3 months) on the other hand. The optimized assay was employed for protein-to-creatinine ratio (PCR) determination on a single paper-based sensor. For both analytes the linear ranges were within the clinically relevant range. The analytical usefulness of the developed sensors was demonstrated by a PCR recovery study in artificial urine. The obtained PCR recoveries were from ca. 80 to 150%.
Open AccessSmartphone-Assisted Protein to Creatinine Ratio Determination on a Single Paper-Based Analytical Device
Proteinuria is a condition in which an excessive amount of protein is excreted in urine. It is, among others, an indicator of kidney disease or risk of cardiovascular disease. Rapid and reliable diagnosis and monitoring of proteinuria is of great importance for both patients and their physicians. For that reason, a paper-based sensor for proteinuria diagnosis was designed, optimized, and validated utilizing smartphone-assisted signal acquisition. In the first step, a few commonly employed protein assays were optimized and compared in terms of analytical performance on paper matrix. The tetrabromophenol blue method was selected as the one providing a sufficiently low limit of detection (39 mg·L−1) on the one hand and appropriate long-term stability (up to 3 months) on the other hand. The optimized assay was employed for protein-to-creatinine ratio (PCR) determination on a single paper-based sensor. For both analytes the linear ranges were within the clinically relevant range. The analytical usefulness of the developed sensors was demonstrated by a PCR recovery study in artificial urine. The obtained PCR recoveries were from ca. 80 to 150%.
- Open Access
- 5 August 2020
- Published by MDPI AG in Nanomaterials
- Vol. 10 (8) , 1534
Multi-Substrate Biofuel Cell Utilizing Glucose, Fructose and Sucrose as the Anode Fuels
A significant problem still exists with the low power output and durability of the bioelectrochemical fuel cells. We constructed a fuel cell with an enzymatic cascade at the anode for efficient energy conversion. The construction involved fabrication of the flow-through cell by three-dimensional printing. Gold nanoparticles with covalently bound naphthoquinone moieties deposited on cellulose/polypyrrole (CPPy) paper allowed us to significantly improve the catalysis rate, both at the anode and cathode of the fuel cell. The enzymatic cascade on the anode consisted of invertase, mutarotase, Flavine Adenine Dinucleotide (FAD)-dependent glucose dehydrogenase and fructose dehydrogenase. The multi-substrate anode utilized glucose, fructose, sucrose, or a combination of them, as the anode fuel and molecular oxygen were the oxidant at the laccase-based cathode. Laccase was adsorbed on the same type of naphthoquinone modified gold nanoparticles. Interestingly, the naphthoquinone modified gold nanoparticles acted as the enzyme orienting units and not as mediators since the catalyzed oxygen reduction occurred at the potential where direct electron transfer takes place. Thanks to the good catalytic and capacitive properties of the modified electrodes, the power density of the sucrose/oxygen enzymatic fuel cells (EFC) reached 0.81 mW cm−2, which is beneficial for a cell composed of a single cathode and anode.
- 5 August 2020
- Published by MDPI AG in Nanomaterials
- Vol. 10 (8) , 1534
Open AccessMulti-Substrate Biofuel Cell Utilizing Glucose, Fructose and Sucrose as the Anode Fuels
A significant problem still exists with the low power output and durability of the bioelectrochemical fuel cells. We constructed a fuel cell with an enzymatic cascade at the anode for efficient energy conversion. The construction involved fabrication of the flow-through cell by three-dimensional printing. Gold nanoparticles with covalently bound naphthoquinone moieties deposited on cellulose/polypyrrole (CPPy) paper allowed us to significantly improve the catalysis rate, both at the anode and cathode of the fuel cell. The enzymatic cascade on the anode consisted of invertase, mutarotase, Flavine Adenine Dinucleotide (FAD)-dependent glucose dehydrogenase and fructose dehydrogenase. The multi-substrate anode utilized glucose, fructose, sucrose, or a combination of them, as the anode fuel and molecular oxygen were the oxidant at the laccase-based cathode. Laccase was adsorbed on the same type of naphthoquinone modified gold nanoparticles. Interestingly, the naphthoquinone modified gold nanoparticles acted as the enzyme orienting units and not as mediators since the catalyzed oxygen reduction occurred at the potential where direct electron transfer takes place. Thanks to the good catalytic and capacitive properties of the modified electrodes, the power density of the sucrose/oxygen enzymatic fuel cells (EFC) reached 0.81 mW cm−2, which is beneficial for a cell composed of a single cathode and anode.
- 1 March 2018
- Published by Elsevier in Sensors and Actuators B: Chemical
- Vol. 257, 16-22
Flow injection analysis in lab-on-paper format
- 1 March 2018
- Published by Elsevier in Sensors and Actuators B: Chemical
- Vol. 257, 16-22
Flow injection analysis in lab-on-paper format