Viktor Doychinov
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Viktor Doychinov has a total of 62 co-authors. Here are the top co-authors by number of shared publications:
- Ian D. Robertson
School of Electronic and Electrical Engineering, University of Leeds, Leeds, U.K.
8 shared publications - Nazar T. Ali
Khalifa University
5 shared publications - Prince O. Siaw
Faculty of Engineering and Informatics, University of Bradford, Bradford, UK
5 shared publications - Raed A. Abd-Alhameed
Faculty of Engineering and Digital Technologies, Bradford University, Bradford BD7 1DP, UK
5 shared publications - Ahmad Aldelemy
Faculty of Engineering and Informatics, University of Bradford, Bradford, UK
4 shared publications - Ebenezer Adjei
Faculty of Engineering and Informatics, University of Bradford, Bradford, UK
4 shared publications
Latest Publications
- Open Access
- 30 March 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 14, 51873-51889
Development of a Traceable Dielectric-Property Dataset for Femoral-Fracture Monitoring in the 1–4-GHz Band With Cross-Database Validation and Machine-Learning Proof of Concept
Reliable dielectric-property models are a prerequisite for credible forward electromagnetic simulation of microwave-based femoral-fracture monitoring systems. This paper presents a traceable dielectric-property dataset for the 1 to 4 GHz band, with explicit surrogate justification and cross-database validation. Reference targets are consolidated from canonical wideband sources and the IT’IS Tissue Properties Database (v5.0). Compact single-term Cole–Cole parameters are fitted for fracture-relevant tissues and healing-stage constituents. Fracture scenarios (fracture type × healing stage) are constructed using mixing rules with uncertainty bounds derived from physiological variability and volume-fraction uncertainty. We explicitly separate property fitting from forward simulation: the fitted properties are intended as inputs to a forward FDTD solver (with CPML) for design studies; no inversion is performed. Across representative tissues, bandwise agreement between fitted models and reference targets yields NRMSE below 10% with Pearson correlation ρ ≥ 0.97. Cross-database comparison against four independent sources (Gabriel, IT’IS, IFAC-CNR, Sasaki/NICT) demonstrates inter-database consistency within 2.4% maximum deviation at 2 GHz for representative tissues; the additional Cole–Cole fitting approximation introduces deviations of up to 6.9%, which remain within the assigned physiological variability bounds. Surrogate selections for healing-stage constituents are justified physiologically based on water content similarity and assigned conservative uncertainty bounds. As a supplementary downstream demonstration, a machine-learning proof of concept reports (i) 56.1% accuracy on a challenging fine-grained 7-class synthetic task and (ii) 57.1% accuracy on an independent external bio-phantom dataset, confirming that the moderate classification accuracy reflects genuine physical overlap between adjacent healing stages. The dataset and protocols are archived on Zenodo (DOI: https://doi.org/10.5281/zenodo.18027914).
- 30 March 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 14, 51873-51889
Open AccessDevelopment of a Traceable Dielectric-Property Dataset for Femoral-Fracture Monitoring in the 1–4-GHz Band With Cross-Database Validation and Machine-Learning Proof of Concept
Reliable dielectric-property models are a prerequisite for credible forward electromagnetic simulation of microwave-based femoral-fracture monitoring systems. This paper presents a traceable dielectric-property dataset for the 1 to 4 GHz band, with explicit surrogate justification and cross-database validation. Reference targets are consolidated from canonical wideband sources and the IT’IS Tissue Properties Database (v5.0). Compact single-term Cole–Cole parameters are fitted for fracture-relevant tissues and healing-stage constituents. Fracture scenarios (fracture type × healing stage) are constructed using mixing rules with uncertainty bounds derived from physiological variability and volume-fraction uncertainty. We explicitly separate property fitting from forward simulation: the fitted properties are intended as inputs to a forward FDTD solver (with CPML) for design studies; no inversion is performed. Across representative tissues, bandwise agreement between fitted models and reference targets yields NRMSE below 10% with Pearson correlation ρ ≥ 0.97. Cross-database comparison against four independent sources (Gabriel, IT’IS, IFAC-CNR, Sasaki/NICT) demonstrates inter-database consistency within 2.4% maximum deviation at 2 GHz for representative tissues; the additional Cole–Cole fitting approximation introduces deviations of up to 6.9%, which remain within the assigned physiological variability bounds. Surrogate selections for healing-stage constituents are justified physiologically based on water content similarity and assigned conservative uncertainty bounds. As a supplementary downstream demonstration, a machine-learning proof of concept reports (i) 56.1% accuracy on a challenging fine-grained 7-class synthetic task and (ii) 57.1% accuracy on an independent external bio-phantom dataset, confirming that the moderate classification accuracy reflects genuine physical overlap between adjacent healing stages. The dataset and protocols are archived on Zenodo (DOI: https://doi.org/10.5281/zenodo.18027914).
- Open Access
- 1 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 26 (15) , 1
AI-Enhanced Early Detection of Abnormal Tibial Fracture Healing Trajectories Using Temporal Deep Learning: A Physics-Aware RF Sensing Approach
- 1 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 26 (15) , 1
Open AccessAI-Enhanced Early Detection of Abnormal Tibial Fracture Healing Trajectories Using Temporal Deep Learning: A Physics-Aware RF Sensing Approach
- Open Access
- 1 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 26 (16) , 1
Physics-Informed RF Features for Bone Fracture Detection and Healing Classification: A Grouped Cross-Validation Study Using 2D-FDTD Simulation Across Five Anatomical Sites
- 1 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 26 (16) , 1
Open AccessPhysics-Informed RF Features for Bone Fracture Detection and Healing Classification: A Grouped Cross-Validation Study Using 2D-FDTD Simulation Across Five Anatomical Sites
- Open Access
- 18 November 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 13, 197381-197413
AI-Enhanced Pilot-Assisted Angle-of-Arrival Estimation for Wearable Devices in Rician Fading Channels: A Low-SNR Focused Method
Accurate angle-of-arrival (AoA) estimation is critical for precise localisation in wearable devices, particularly in challenging wireless environments such as Rician fading with low signal-to-noise ratios (SNRs). This paper proposes a pilot-assisted AoA estimation technique that integrates pseudo-random permutations and Walsh sequences within an OFDM-based transmission framework. The method preserves phase coherence and enhances spatial resolution by optimising pilot allocation and leveraging advanced signal processing. Comprehensive Matlab simulations show sub-degree AoA errors, with robustness validated in ultra-dense multipath scenarios where the Rician K-factor is less than 3 dB. Furthermore, a lightweight, one-dimensional (1D) convolutional neural network (CNN) reduces residual carrier-frequency offsets by over 30%, highlighting a promising synergy between classical signal processing and data-driven learning. Comparative analysis against state-of-the-art techniques and a discussion of computational complexity are provided, underscoring the suitability of the proposed method for next-generation wearable and IoT direction-finding applications.
- 18 November 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 13, 197381-197413
Open AccessAI-Enhanced Pilot-Assisted Angle-of-Arrival Estimation for Wearable Devices in Rician Fading Channels: A Low-SNR Focused Method
Accurate angle-of-arrival (AoA) estimation is critical for precise localisation in wearable devices, particularly in challenging wireless environments such as Rician fading with low signal-to-noise ratios (SNRs). This paper proposes a pilot-assisted AoA estimation technique that integrates pseudo-random permutations and Walsh sequences within an OFDM-based transmission framework. The method preserves phase coherence and enhances spatial resolution by optimising pilot allocation and leveraging advanced signal processing. Comprehensive Matlab simulations show sub-degree AoA errors, with robustness validated in ultra-dense multipath scenarios where the Rician K-factor is less than 3 dB. Furthermore, a lightweight, one-dimensional (1D) convolutional neural network (CNN) reduces residual carrier-frequency offsets by over 30%, highlighting a promising synergy between classical signal processing and data-driven learning. Comparative analysis against state-of-the-art techniques and a discussion of computational complexity are provided, underscoring the suitability of the proposed method for next-generation wearable and IoT direction-finding applications.
- Open Access
- 30 December 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 13, 11114-11135
Monitoring Bone Healing: Integrating RF Sensing With AI
This study presents the development of an advanced machine learning model based on a two-dimensional (2D) Radio Frequency (RF) sensing framework for refined monitoring of femoral bone fractures. Utilising MATLAB simulations, we created a comprehensive dataset enhanced with variations in bone diameter, muscle thickness, fat thickness, and hematoma size, augmented with multiple sensor configurations (two, four, six, and eight sensors). The model aims to provide a frequent, non-invasive assessment of the fracture healing process compared to conventional imaging methods. Our approach leverages data from six RF sensors, achieving a high overall accuracy of 99.2% in classifying different fracture stages, including "no fracture" and varying degrees of hematoma sizes. The findings indicate that increasing the number of sensors up to six significantly enhances detection accuracy and sensitivity across all fracture stages. However, the marginal improvement from six to eight sensors was not statistically significant, suggesting that a six-sensor configuration offers an optimal balance between performance and system complexity. The results demonstrate significant potential for this technology to revolutionise orthopaedic treatment and recovery management by offering continuous, real-time monitoring without radiation exposure. The proposed system enhances personalised patient care by integrating RF sensing with artificial intelligence, enabling timely interventions and more informed, data-driven treatment strategies. This research lays a robust foundation for future advancements, including three-dimensional modelling and clinical validations, toward the practical implementation of non-invasive fracture monitoring systems.
- 30 December 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 13, 11114-11135
Open AccessMonitoring Bone Healing: Integrating RF Sensing With AI
This study presents the development of an advanced machine learning model based on a two-dimensional (2D) Radio Frequency (RF) sensing framework for refined monitoring of femoral bone fractures. Utilising MATLAB simulations, we created a comprehensive dataset enhanced with variations in bone diameter, muscle thickness, fat thickness, and hematoma size, augmented with multiple sensor configurations (two, four, six, and eight sensors). The model aims to provide a frequent, non-invasive assessment of the fracture healing process compared to conventional imaging methods. Our approach leverages data from six RF sensors, achieving a high overall accuracy of 99.2% in classifying different fracture stages, including "no fracture" and varying degrees of hematoma sizes. The findings indicate that increasing the number of sensors up to six significantly enhances detection accuracy and sensitivity across all fracture stages. However, the marginal improvement from six to eight sensors was not statistically significant, suggesting that a six-sensor configuration offers an optimal balance between performance and system complexity. The results demonstrate significant potential for this technology to revolutionise orthopaedic treatment and recovery management by offering continuous, real-time monitoring without radiation exposure. The proposed system enhances personalised patient care by integrating RF sensing with artificial intelligence, enabling timely interventions and more informed, data-driven treatment strategies. This research lays a robust foundation for future advancements, including three-dimensional modelling and clinical validations, toward the practical implementation of non-invasive fracture monitoring systems.
- Open Access
- 1 August 2020
- Published by Elsevier in Additive Manufacturing
- Vol. 34
Light based synthesis of metallic nanoparticles on surface-modified 3D printed substrates for high performance electronic systems
- 1 August 2020
- Published by Elsevier in Additive Manufacturing
- Vol. 34
Open AccessLight based synthesis of metallic nanoparticles on surface-modified 3D printed substrates for high performance electronic systems
- Open Access
- 19 May 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 8, 95878-95887
Wireless Power Transfer System for Battery-Less Sensor Nodes
For the first time, the design and implementation of a fully-integrated wireless information and power transfer system, operating at 24 GHz and enabling battery-less sensor nodes, is presented in this paper. The system consists of an RF power source, a receiver antenna array, a rectifier, and a battery-less sensor node which communicates via backscatter modulation at 868 MHz. The rectifier circuits use commercially available Schottky diodes to convert the RF power to DC with a measured efficiency of up to 35%, an improvement of ten percentage points compared with previously reported results. The rectifiers and the receive antenna arrays were jointly designed and optimised, thereby reducing the overall circuit size. The battery-less sensor transmitted data to a base station realised as a GNU Radio flow running on a bladeRF Software Defined Radio module. The whole system was tested in free-space in laboratory conditions and was capable of providing sufficient energy to the sensor node in order to enable operation and wireless communication at a distance of 0.15 metres.
- 19 May 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 8, 95878-95887
Open AccessWireless Power Transfer System for Battery-Less Sensor Nodes
For the first time, the design and implementation of a fully-integrated wireless information and power transfer system, operating at 24 GHz and enabling battery-less sensor nodes, is presented in this paper. The system consists of an RF power source, a receiver antenna array, a rectifier, and a battery-less sensor node which communicates via backscatter modulation at 868 MHz. The rectifier circuits use commercially available Schottky diodes to convert the RF power to DC with a measured efficiency of up to 35%, an improvement of ten percentage points compared with previously reported results. The rectifiers and the receive antenna arrays were jointly designed and optimised, thereby reducing the overall circuit size. The battery-less sensor transmitted data to a base station realised as a GNU Radio flow running on a bladeRF Software Defined Radio module. The whole system was tested in free-space in laboratory conditions and was capable of providing sufficient energy to the sensor node in order to enable operation and wireless communication at a distance of 0.15 metres.
- Open Access
- 1 January 2019
- Published by IOP Publishing in Journal of Physics Communications
- Vol. 3 (1) , 015017
Higher-order mode substrate integrated waveguide cavity excitation for microstrip patch antenna arrays at 30-GHz
This paper presents a novel approach to the design and fabrication of low-cost and high-gain aperture-coupled microstrip patch antenna (AC-MPA) arrays with improved radiation pattern for millimetre-wave applications such as simultaneous wireless information and power transfer (SWIPT) and Internet-of-Things (IoT) device connectivity. A higher-order mode substrate integrated waveguide (SIW) cavity is used to feed the MPA arrays through aperture coupling. The improved design approach is introduced and discussed in detail. Simulation and experimental results for 2x2 and 4x4 arrays are presented, demonstrating excellent agreement. Key performance metrics are side-lobe levels of less than -24 dB and -29 dB in the E-plane and -22 dB and -26 dB in the H-plane and realized gain of 11 dBi and 15 dBi for the 2x2 and 4x4 arrays respectively, at a design frequency of 30 GHz.
- 1 January 2019
- Published by IOP Publishing in Journal of Physics Communications
- Vol. 3 (1) , 015017
Open AccessHigher-order mode substrate integrated waveguide cavity excitation for microstrip patch antenna arrays at 30-GHz
This paper presents a novel approach to the design and fabrication of low-cost and high-gain aperture-coupled microstrip patch antenna (AC-MPA) arrays with improved radiation pattern for millimetre-wave applications such as simultaneous wireless information and power transfer (SWIPT) and Internet-of-Things (IoT) device connectivity. A higher-order mode substrate integrated waveguide (SIW) cavity is used to feed the MPA arrays through aperture coupling. The improved design approach is introduced and discussed in detail. Simulation and experimental results for 2x2 and 4x4 arrays are presented, demonstrating excellent agreement. Key performance metrics are side-lobe levels of less than -24 dB and -29 dB in the E-plane and -22 dB and -26 dB in the H-plane and realized gain of 11 dBi and 15 dBi for the 2x2 and 4x4 arrays respectively, at a design frequency of 30 GHz.
- 1 July 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-3
Hybrid Additive Manufacture of Conformal Antennas
This paper presents a new digitally driven manufacturing process chain for the production of high performance, three-dimensional RF devices. This is achieved by combining Fused Filament Fabrication of polyetherimide based polymer with selective light-based synthesis of silver nanoparticles and electrochemical deposition of copper. The resultant manufacturing method produces devices with excellent DC electrical resistivity (6.68 μΩ cm) and dielectric properties (relative permittivity of 2.67 and loss tangent of 0.001). Chemically modifying and patterning the substrate to produce the metallization overcomes many of the limitations of direct write deposition methods resulting in improved performance, adhesion and resolution of the antenna pattern. The fabricated demonstrators cover a broadband range of 0.1 GHz - 10 GHz and the measured results show a direct agreement with the simulated design over a wide frequency band. Overall the materials used as a substrate have a low relative permittivity and lower dielectric loss than FR-4, thereby making them well suited for antenna applications.
- 1 July 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-3
Hybrid Additive Manufacture of Conformal Antennas
This paper presents a new digitally driven manufacturing process chain for the production of high performance, three-dimensional RF devices. This is achieved by combining Fused Filament Fabrication of polyetherimide based polymer with selective light-based synthesis of silver nanoparticles and electrochemical deposition of copper. The resultant manufacturing method produces devices with excellent DC electrical resistivity (6.68 μΩ cm) and dielectric properties (relative permittivity of 2.67 and loss tangent of 0.001). Chemically modifying and patterning the substrate to produce the metallization overcomes many of the limitations of direct write deposition methods resulting in improved performance, adhesion and resolution of the antenna pattern. The fabricated demonstrators cover a broadband range of 0.1 GHz - 10 GHz and the measured results show a direct agreement with the simulated design over a wide frequency band. Overall the materials used as a substrate have a low relative permittivity and lower dielectric loss than FR-4, thereby making them well suited for antenna applications.
- Open Access
- 18 June 2018
- Published by IOP Publishing in Journal of Physics D: Applied Physics
- Vol. 51 (27) , 275103
Multi-modal millimeter-wave sensors for plastic polymer material characterization
This paper presents, for the first time, a multimodal sensor for characterizing relative permittivity of plastic polymers by integrating in a single sensor (1) frequency-reconfigurable resonance technique at 98 and 100 GHz, and (2) 80–100 GHz broadband modified transmission-line technique. The sensor is designed based on a custom-made WR-10 waveguide featuring dual rectangular complementary split-ring resonators (CSRRs). By loading the CSRRs with a material-under-test (MUT), the reflected and transmitted electromagnetic waves propagating inside the waveguide are changed depending on the dielectric properties of the material. Various plastic polymer materials, e.g. polytetrafluoroethylene (PTFE), polymethylmethacrylate (PMMA) and high-density polyethylene (HDPE), are characterized. The sensor in this paper offers various key advantages over any state-of-the-art material characterization techniques at millimeter-wave frequencies, e.g. multiple characterization techniques integrated in a single device, miniaturization, much higher tolerance to changes in the measurement environment, ease of design and fabrication, and better cost effectiveness.
- 18 June 2018
- Published by IOP Publishing in Journal of Physics D: Applied Physics
- Vol. 51 (27) , 275103
Open AccessMulti-modal millimeter-wave sensors for plastic polymer material characterization
This paper presents, for the first time, a multimodal sensor for characterizing relative permittivity of plastic polymers by integrating in a single sensor (1) frequency-reconfigurable resonance technique at 98 and 100 GHz, and (2) 80–100 GHz broadband modified transmission-line technique. The sensor is designed based on a custom-made WR-10 waveguide featuring dual rectangular complementary split-ring resonators (CSRRs). By loading the CSRRs with a material-under-test (MUT), the reflected and transmitted electromagnetic waves propagating inside the waveguide are changed depending on the dielectric properties of the material. Various plastic polymer materials, e.g. polytetrafluoroethylene (PTFE), polymethylmethacrylate (PMMA) and high-density polyethylene (HDPE), are characterized. The sensor in this paper offers various key advantages over any state-of-the-art material characterization techniques at millimeter-wave frequencies, e.g. multiple characterization techniques integrated in a single device, miniaturization, much higher tolerance to changes in the measurement environment, ease of design and fabrication, and better cost effectiveness.