Petri Kärhä
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Petri Kärhä has a total of 282 co-authors. Here are the top co-authors by number of shared publications:
Erkki Ikonen
39 shared publications- Erkki Ikonen
Metrology Research Institute, Aalto University, 02150 Espoo, Finland
14 shared publications E Ikonen
Metrology Research Institute, Aalto University, Espoo, Finland
13 shared publicationsAnna Vaskuri
Aalto University
8 shared publicationsTuomas Poikonen
MIKES Metrology, VTT Technical Research Centre of Finland Ltd, PO Box 1000, 02044 VTT, Finland
7 shared publicationsFarshid Manoocheri
Metrology Research Institute, Aalto University School of Electrical Engineering, Maarintie 8, Espoo, Finland
6 shared publications
Latest Publications
- Open Access
- 18 August 2026
- Published by Springer Nature in Nature Energy
- Vol. 11 (9) , 1241-1259
Best practices for measuring the performance and stability of indoor photovoltaic devices
- 18 August 2026
- Published by Springer Nature in Nature Energy
- Vol. 11 (9) , 1241-1259
Open AccessBest practices for measuring the performance and stability of indoor photovoltaic devices
- Open Access
- 27 April 2026
- Published by Elsevier in Results in Engineering
- Vol. 30
Results of an interlaboratory comparison of adapted reference solar cells among nine metrological institutes
- 27 April 2026
- Published by Elsevier in Results in Engineering
- Vol. 30
Open AccessResults of an interlaboratory comparison of adapted reference solar cells among nine metrological institutes
- Open Access
- 6 March 2026
- Published by Wiley in Photochemistry and Photobiology
- Vol. 102 (5) , 1112-1122
Spectral characterization of three wearable electronic ultraviolet radiation dosimeters
Excessive exposure to ultraviolet (UV) radiation poses significant public health risks, including DNA damage and skin‐related pathologies. This necessitates accurate studies and quantification of UV‐radiation exposure. Various wearable UV dosimeters have been developed to address these needs, particularly for outdoor workers. For measuring erythemal irradiance, recommendations from the World Meteorological Organization exist but standardized methods for characterization and calibration of wearable UV dosimeters are currently limited. At Aalto University and at Physikalisch‐Meteorologisches Observatorium Davos, three commercial electronic UV dosimeters were evaluated for their spectral responsivities using conventional measurement methods and traceability chains. The first device closely mimicked erythemal action in UV‐A and UV‐B regions. Two of the measured devices were found to have a higher relative responsivity of over 0.9 in the 300 nm to 310 nm range. Results were used to calculate correction factors for measuring erythemal radiance at varying solar zenith angles and ozone levels under cloud‐free conditions. Typical correction factors ranged from 0.98 to 1.2. The results of the two laboratories were in good agreement for the most accurate device but deviated due to the properties of the two other devices. The measurements revealed challenges posed by these devices in terms of data management, measurement times, and deployment, highlighting the need for standardized characterization methods.
- 6 March 2026
- Published by Wiley in Photochemistry and Photobiology
- Vol. 102 (5) , 1112-1122
Open AccessSpectral characterization of three wearable electronic ultraviolet radiation dosimeters
Excessive exposure to ultraviolet (UV) radiation poses significant public health risks, including DNA damage and skin‐related pathologies. This necessitates accurate studies and quantification of UV‐radiation exposure. Various wearable UV dosimeters have been developed to address these needs, particularly for outdoor workers. For measuring erythemal irradiance, recommendations from the World Meteorological Organization exist but standardized methods for characterization and calibration of wearable UV dosimeters are currently limited. At Aalto University and at Physikalisch‐Meteorologisches Observatorium Davos, three commercial electronic UV dosimeters were evaluated for their spectral responsivities using conventional measurement methods and traceability chains. The first device closely mimicked erythemal action in UV‐A and UV‐B regions. Two of the measured devices were found to have a higher relative responsivity of over 0.9 in the 300 nm to 310 nm range. Results were used to calculate correction factors for measuring erythemal radiance at varying solar zenith angles and ozone levels under cloud‐free conditions. Typical correction factors ranged from 0.98 to 1.2. The results of the two laboratories were in good agreement for the most accurate device but deviated due to the properties of the two other devices. The measurements revealed challenges posed by these devices in terms of data management, measurement times, and deployment, highlighting the need for standardized characterization methods.
- Open Access
- 5 December 2025
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 36 (12) , 127001
Measurement of temporal light modulation using a hyperspectral camera
In the European Union, temporal light artifacts (TLAs) have recently been regulated for mains-connected LED lamps and luminaires available on the market. However, the limitations are only on white LED sources. Colored LED sources are not under current regulation, although they are often used as components to create a source that looks like a white source to an observer. We present a measurement setup based on a hyperspectral camera to measure different types of luminaires simultaneously to quantify the spectral components of the TLA metrics. The camera has one-megapixel spatial resolution and can measure at 1000 different wavelengths with a bandwidth of 10 nm. The sampling frequency of the camera was extended from 100 frames per second (fps) to 1000 fps using triggering with a varied delay, and waveforms within an integration time of 1 s were captured. We demonstrate measurements of white LED lamps at wavelengths of 450 nm, 550 nm and 650 nm, and compare the results of the TLA metrics with other measurement setups. We observed that for one of the lamps, the hyperspectral measurements deviated only 3% from the reference values, while for the other lamp, the demonstrative measurement system did not have sufficient performance, which increased the deviations significantly.
- 5 December 2025
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 36 (12) , 127001
Open AccessMeasurement of temporal light modulation using a hyperspectral camera
In the European Union, temporal light artifacts (TLAs) have recently been regulated for mains-connected LED lamps and luminaires available on the market. However, the limitations are only on white LED sources. Colored LED sources are not under current regulation, although they are often used as components to create a source that looks like a white source to an observer. We present a measurement setup based on a hyperspectral camera to measure different types of luminaires simultaneously to quantify the spectral components of the TLA metrics. The camera has one-megapixel spatial resolution and can measure at 1000 different wavelengths with a bandwidth of 10 nm. The sampling frequency of the camera was extended from 100 frames per second (fps) to 1000 fps using triggering with a varied delay, and waveforms within an integration time of 1 s were captured. We demonstrate measurements of white LED lamps at wavelengths of 450 nm, 550 nm and 650 nm, and compare the results of the TLA metrics with other measurement setups. We observed that for one of the lamps, the hyperspectral measurements deviated only 3% from the reference values, while for the other lamp, the demonstrative measurement system did not have sufficient performance, which increased the deviations significantly.
- Open Access
Results of an International Comparison of Indoor Photovoltaic Measurements Among Seven Metrological Institutes
This study presents results of an intercomparison of indoor photovoltaics (PVs) among seven metrological institutes. Three types of solar cells were measured; organic and amorphous silicon cells representing current indoor products in the market and a reference solar cell. Three different light sources—AM1.5G, International Commission of Illumination Standard Illuminant A, and light‐emitting diodes (LED) L41—were used at illuminance levels 100–2000 lx. Each laboratory reported short‐circuit current as mandatory. Open‐circuit voltage, maximum power, and differential spectral responsivity were reported where possible. Measurements revealed notable discrepancies. At the 1000 lx level, best agreement of 7% as standard deviation was achieved for the amorphous silicon cell using Standard Illuminant A. Similarly, the worst agreement of 37% was found for the reference cell using AM1.5G. Measurement methods varied across the laboratories. Some participants used lamps for Standard Illuminant A and LED L41. These measurements were generally in agreement but deviated from measurements with LED‐based solar simulators, due to differences in measurement geometry, spectral properties, and treatment of infrared. Different illuminance measurement approaches, using either calibrated reference cells or luxmeters, further impacted consistency. This study highlights need for harmonized procedures to support reliable performance assessment of indoor PVs and gives recommendations to account for in standards.
Open AccessResults of an International Comparison of Indoor Photovoltaic Measurements Among Seven Metrological Institutes
This study presents results of an intercomparison of indoor photovoltaics (PVs) among seven metrological institutes. Three types of solar cells were measured; organic and amorphous silicon cells representing current indoor products in the market and a reference solar cell. Three different light sources—AM1.5G, International Commission of Illumination Standard Illuminant A, and light‐emitting diodes (LED) L41—were used at illuminance levels 100–2000 lx. Each laboratory reported short‐circuit current as mandatory. Open‐circuit voltage, maximum power, and differential spectral responsivity were reported where possible. Measurements revealed notable discrepancies. At the 1000 lx level, best agreement of 7% as standard deviation was achieved for the amorphous silicon cell using Standard Illuminant A. Similarly, the worst agreement of 37% was found for the reference cell using AM1.5G. Measurement methods varied across the laboratories. Some participants used lamps for Standard Illuminant A and LED L41. These measurements were generally in agreement but deviated from measurements with LED‐based solar simulators, due to differences in measurement geometry, spectral properties, and treatment of infrared. Different illuminance measurement approaches, using either calibrated reference cells or luxmeters, further impacted consistency. This study highlights need for harmonized procedures to support reliable performance assessment of indoor PVs and gives recommendations to account for in standards.
- Open Access
- 23 October 2024
- Published by Springer Nature in Photochemical & Photobiological Sciences
- Vol. 23 (11) , 2045-2056
Infrared-A to improve mood: an exploratory study of water-filtered infrared-A (wIRA) exposure
Diurnal preference to eveningness might predispose to depression. There is preliminary evidence of infrared-A (IR-A) induced whole-body hyperthermia (WBH) in the treatment of depression. In this exploratory study with 19 adults, we investigated the effects of a 20-min exposure of water-filtered IR-A (wIRA) to the skin of back and buttock area, without inducing WBH, on mood and assessed the outcome by diurnal preference (#R19047, approval on 7 May 2019). The skin received irradiation with an integrated power of 102.4 W in the wavelength region of 550–1350 nm and a total dose of 123 kJ over the total area of 0.0483 m2. The diurnal preference was assessed with a 6-item version of the Morningness-Eveningness Questionnaire (mMEQ). The 40-item Profile of Mood States (POMS) questionnaire was used to assess total mood disturbance (TMD). Core temperature was measured 30 min before, during and 30 min after the irradiation. Skin surface temperature was measured on baseline and every two minutes during the irradiation. The TMD improved immediately after the exposure, and this positive effect lasted for 24 h (p = 0.001) as well as for 2 weeks (p = 0.02). Concerning the diurnal preference, the positive effect on mood was immediate and lasted for 24 h in evening types (p = 0.02) and for 2 weeks in morning types (p = 0.04). During the exposure, core body temperature was constantly lower in morning types compared to evening types. This study gives us new information on the effects of near-infrared radiation, without inducing WBH, through the skin on mood. Graphical abstract
- 23 October 2024
- Published by Springer Nature in Photochemical & Photobiological Sciences
- Vol. 23 (11) , 2045-2056
Open AccessInfrared-A to improve mood: an exploratory study of water-filtered infrared-A (wIRA) exposure
Diurnal preference to eveningness might predispose to depression. There is preliminary evidence of infrared-A (IR-A) induced whole-body hyperthermia (WBH) in the treatment of depression. In this exploratory study with 19 adults, we investigated the effects of a 20-min exposure of water-filtered IR-A (wIRA) to the skin of back and buttock area, without inducing WBH, on mood and assessed the outcome by diurnal preference (#R19047, approval on 7 May 2019). The skin received irradiation with an integrated power of 102.4 W in the wavelength region of 550–1350 nm and a total dose of 123 kJ over the total area of 0.0483 m2. The diurnal preference was assessed with a 6-item version of the Morningness-Eveningness Questionnaire (mMEQ). The 40-item Profile of Mood States (POMS) questionnaire was used to assess total mood disturbance (TMD). Core temperature was measured 30 min before, during and 30 min after the irradiation. Skin surface temperature was measured on baseline and every two minutes during the irradiation. The TMD improved immediately after the exposure, and this positive effect lasted for 24 h (p = 0.001) as well as for 2 weeks (p = 0.02). Concerning the diurnal preference, the positive effect on mood was immediate and lasted for 24 h in evening types (p = 0.02) and for 2 weeks in morning types (p = 0.04). During the exposure, core body temperature was constantly lower in morning types compared to evening types. This study gives us new information on the effects of near-infrared radiation, without inducing WBH, through the skin on mood. Graphical abstract
- Open Access
- 21 October 2024
- Published by SAGE Publications in Lighting Research & Technology
- Vol. 56 (7) , 790-799
Improvement of temporal light artefact effects in commercial LED lamps
Temporal light modulation and its potential adverse visual effects on human observers, collectively known as temporal light artefacts (TLAs), have been limited by the European Union Ecodesign regulation. Limitations on two key TLA metrics, flicker and stroboscopic effect, were introduced in September 2021. This study analyses the impact of this regulation on commercial LED lamps by measuring multiple different consumer-grade LED E27 retrofit lamps by several manufacturers before and after the regulation. The lamps purchased after the Ecodesign regulation seem to favour a certain type of LED driver that provides the best TLA behaviour of all lamp types. The regulation, with respect to TLA, has resulted in the replacement of ill-behaving lamp types in the market by newer lamps with better TLA characteristics.
- 21 October 2024
- Published by SAGE Publications in Lighting Research & Technology
- Vol. 56 (7) , 790-799
Open AccessImprovement of temporal light artefact effects in commercial LED lamps
Temporal light modulation and its potential adverse visual effects on human observers, collectively known as temporal light artefacts (TLAs), have been limited by the European Union Ecodesign regulation. Limitations on two key TLA metrics, flicker and stroboscopic effect, were introduced in September 2021. This study analyses the impact of this regulation on commercial LED lamps by measuring multiple different consumer-grade LED E27 retrofit lamps by several manufacturers before and after the regulation. The lamps purchased after the Ecodesign regulation seem to favour a certain type of LED driver that provides the best TLA behaviour of all lamp types. The regulation, with respect to TLA, has resulted in the replacement of ill-behaving lamp types in the market by newer lamps with better TLA characteristics.
- Open Access
- 27 November 2023
- Published by IOP Publishing in Metrologia
- Vol. 61 (1) , 015002
Spectral analysis of deviations from key comparison reference values
When studying the results of the key comparisons of spectral quantities, it appears that in many cases participants’ results systematically deviate from the key comparison reference values over a limited spectral range. We carried out spectral analysis of such deviations in seven key comparisons of optical radiometry. The results reveal an approximate outcome that, on the average, each harmonic amplitude is inversely proportional to the order of the harmonic in all studied key comparisons. This new finding gives important information on the characteristics of spectral correlations. The result can be used in the uncertainty evaluation of spectral integrals, where the effect of unknown spectral correlations has earlier been challenging to assess quantitatively.
- 27 November 2023
- Published by IOP Publishing in Metrologia
- Vol. 61 (1) , 015002
Open AccessSpectral analysis of deviations from key comparison reference values
When studying the results of the key comparisons of spectral quantities, it appears that in many cases participants’ results systematically deviate from the key comparison reference values over a limited spectral range. We carried out spectral analysis of such deviations in seven key comparisons of optical radiometry. The results reveal an approximate outcome that, on the average, each harmonic amplitude is inversely proportional to the order of the harmonic in all studied key comparisons. This new finding gives important information on the characteristics of spectral correlations. The result can be used in the uncertainty evaluation of spectral integrals, where the effect of unknown spectral correlations has earlier been challenging to assess quantitatively.
- Open Access
- 18 September 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Photovoltaics
- Vol. 13 (6) , 899-904
Spectral Mismatch Uncertainty Estimation in Solar Cell Calibration Using Monte Carlo Simulation
A solar cell is characterized using a solar simulator and a reference cell in accordance with standard testing conditions. Deviations between the spectral responsivities of the reference cell and the cell being studied, and deviations of the spectral irradiance of the light source used from the specified air mass 1.5 introduce systematic errors in the calibration of solar cells. These errors are corrected with the so-called spectral mismatch (SMM) correction factor. We demonstrate a Monte Carlo simulation-based analysis of the uncertainties present in an SMM correction factor taking into account the possible spectral correlations of the input parameters, such as the spectral irradiance and the spectral responsivities of the reference cell and the solar cell under test. We also perform a detailed uncertainty analysis of the subcomponents of the SMM factor mainly arising from the spectral irradiance incident on the solar cell. In order to test our estimates, we present a comparison of the uncertainties by six other independent calculations carried out by other institutes. We obtain the worst-case, average, and best-case scenario uncertainties of the SMM correction factor by assuming components to be severely correlated, partially correlated, and not correlated, respectively. The corresponding expanded uncertainties ( k $=$ 2) are 1.26%, 0.44%, and 0.06%. The worst- and best-case uncertainties lie at the maximum and minimum extremes of the uncertainties estimated by the participants, while the uncertainty estimate obtained assuming partial correlations is close to the median and mean of all results.
- 18 September 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Photovoltaics
- Vol. 13 (6) , 899-904
Open AccessSpectral Mismatch Uncertainty Estimation in Solar Cell Calibration Using Monte Carlo Simulation
A solar cell is characterized using a solar simulator and a reference cell in accordance with standard testing conditions. Deviations between the spectral responsivities of the reference cell and the cell being studied, and deviations of the spectral irradiance of the light source used from the specified air mass 1.5 introduce systematic errors in the calibration of solar cells. These errors are corrected with the so-called spectral mismatch (SMM) correction factor. We demonstrate a Monte Carlo simulation-based analysis of the uncertainties present in an SMM correction factor taking into account the possible spectral correlations of the input parameters, such as the spectral irradiance and the spectral responsivities of the reference cell and the solar cell under test. We also perform a detailed uncertainty analysis of the subcomponents of the SMM factor mainly arising from the spectral irradiance incident on the solar cell. In order to test our estimates, we present a comparison of the uncertainties by six other independent calculations carried out by other institutes. We obtain the worst-case, average, and best-case scenario uncertainties of the SMM correction factor by assuming components to be severely correlated, partially correlated, and not correlated, respectively. The corresponding expanded uncertainties ( k $=$ 2) are 1.26%, 0.44%, and 0.06%. The worst- and best-case uncertainties lie at the maximum and minimum extremes of the uncertainties estimated by the participants, while the uncertainty estimate obtained assuming partial correlations is close to the median and mean of all results.
- Open Access
- 1 January 2022
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 2149 (1) , 012006
Optical power scale realization using the predictable quantum efficient detector
We report realization of scales for optical power of lasers and spectral responsivity of laser power detectors based on a predictable quantum efficient detector (PQED) over the spectral range of 400 nm–800 nm. The PQED is characterized and used to measure optical power of a laser that is further used in calibration of the responsivities of a working standard trap detector at four distinct laser lines, with an expanded uncertainty of about 0.05%. We present a comparison of responsivities calibrated against the PQED at Aalto and the cryogenic radiometer at RISE, Sweden. The measurement results support the concept that the PQED can be used as a primary standard of optical power.
- 1 January 2022
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 2149 (1) , 012006
Open AccessOptical power scale realization using the predictable quantum efficient detector
We report realization of scales for optical power of lasers and spectral responsivity of laser power detectors based on a predictable quantum efficient detector (PQED) over the spectral range of 400 nm–800 nm. The PQED is characterized and used to measure optical power of a laser that is further used in calibration of the responsivities of a working standard trap detector at four distinct laser lines, with an expanded uncertainty of about 0.05%. We present a comparison of responsivities calibrated against the PQED at Aalto and the cryogenic radiometer at RISE, Sweden. The measurement results support the concept that the PQED can be used as a primary standard of optical power.