Sara Matteoli
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Sara Matteoli has a total of 37 co-authors. Here are the top co-authors by number of shared publications:
Andrea Corvi
Department of Industrial Engineering, University of Florence, Florence, Italy
9 shared publicationsAndrea Sodi
Department of Surgery and Translational Medicine, University of Florence, Firenze, Toscana, ITALY
3 shared publications- Jens Erik Wilhjelm
Department of Health Technology, Technical University of Denmark, Kongens Lyngby, Denmark
2 shared publications - Lucia Finocchio
Department of Ophthalmology, University Hospital of Udine, 33100 Udine, Italy
2 shared publications Rita Mencucci
Department of Medicine and Translational Surgery, Universita degli Studi di Firenze Scuola di Scienze della Salute Umana, Firenze, Toscana, ITALY
2 shared publicationsAndrea Ciabattini
Department of Industrial Engineering, University of Florence, via di S. Marta 3, 50139 Florence, Italy
1 shared publication
Latest Publications
- 1 April 2020
- Published by IOP Publishing in Physiological Measurement
- Vol. 41 (4) , 045003
Infrared thermographic investigation on the ocular surface temperature of normal subjects
Objective : It is understood that the ability to measure ocular temperature accurately will increase understanding of ocular physiology and should be a support in decision-making in classical diagnostic procedures. The use of ocular thermography offers great opportunities for monitoring the temperature of the anterior eye and analyzing the effects of certain pathologies on ocular surface temperature (OST). The aim of the present work is to measure the OST of 220 healthy normal subjects, stratified according to gender and age, in order to obtain a normal temperature distribution to be used as reference values when comparing healthy versus pathological conditions. Approach : The OST is measured from five regions, located over the whole area of the anterior eye, which correspond to particular anatomic structures, through a semi-automated procedure to post-process the infrared images. The relationship between OST and independent variables (forehead skin temperature, age, gender, level of physical activity, cardiovascular risk factors including sedentary lifestyle and smoking, laboratory temperature, and laboratory humidity) was investigated through linear regression models. Main results : The OSTs measured from the five different ocular regions are statistically different ( p -value < 0.001), even when dividing our subjects into males and females, with the nasal cantus being the hottest region and the central cornea the coolest; when considering also the effect of age, stratifying our subjects into young, middle-aged and elderly, the OST decreases when age increases significantly. Statistical analysis based on linear regression models pointed out that age, forehead skin temperature, and lab temperature are the main factors to be taken into account when exploring the OST. Significance : As OST evaluation can be important in detecting different ocular pathologies, having precise details of the variation in temperature across the ocular surface and therefore a more detailed map of the OST adjusted according to subject characteristics and environment conditions could enhance early diagnosis and thus course of treatments.
- 1 April 2020
- Published by IOP Publishing in Physiological Measurement
- Vol. 41 (4) , 045003
Infrared thermographic investigation on the ocular surface temperature of normal subjects
Objective : It is understood that the ability to measure ocular temperature accurately will increase understanding of ocular physiology and should be a support in decision-making in classical diagnostic procedures. The use of ocular thermography offers great opportunities for monitoring the temperature of the anterior eye and analyzing the effects of certain pathologies on ocular surface temperature (OST). The aim of the present work is to measure the OST of 220 healthy normal subjects, stratified according to gender and age, in order to obtain a normal temperature distribution to be used as reference values when comparing healthy versus pathological conditions. Approach : The OST is measured from five regions, located over the whole area of the anterior eye, which correspond to particular anatomic structures, through a semi-automated procedure to post-process the infrared images. The relationship between OST and independent variables (forehead skin temperature, age, gender, level of physical activity, cardiovascular risk factors including sedentary lifestyle and smoking, laboratory temperature, and laboratory humidity) was investigated through linear regression models. Main results : The OSTs measured from the five different ocular regions are statistically different ( p -value < 0.001), even when dividing our subjects into males and females, with the nasal cantus being the hottest region and the central cornea the coolest; when considering also the effect of age, stratifying our subjects into young, middle-aged and elderly, the OST decreases when age increases significantly. Statistical analysis based on linear regression models pointed out that age, forehead skin temperature, and lab temperature are the main factors to be taken into account when exploring the OST. Significance : As OST evaluation can be important in detecting different ocular pathologies, having precise details of the variation in temperature across the ocular surface and therefore a more detailed map of the OST adjusted according to subject characteristics and environment conditions could enhance early diagnosis and thus course of treatments.
- 14 March 2018
- Published by Springer Nature in Medical & Biological Engineering & Computing
- Vol. 56 (10) , 1747-1756
A novel image processing procedure for thermographic image analysis
The imaging procedure shown in this paper has been developed for processing thermographic images, measuring the ocular surface temperature (OST) and visualizing the ocular thermal maps in a fast, reliable, and reproducible way. The strength of this new method is that the measured OSTs do not depend on the ocular geometry; hence, it is possible to compare the ocular profiles belonging to the same subject (right and left eye) as well as to different populations. In this paper, the developed procedure is applied on two subjects’ eyes: a healthy case and another affected by an ocular malignant lesion. However, the method has already been tested on a bigger group of subjects for clinical purpose. For demonstrating the potentiality of this method, both intra- and inter-examiner repeatability were investigated in terms of coefficients of repeatability (COR). All OST indices showed repeatability with small intra-examiner (%COR 0.06–0.80) and inter-examiner variability (%COR 0.03–0.94). Measured OSTs and thermal maps clearly showed the clinical condition of the eyes investigated. The subject with no ocular pathology had no significant difference (P value = 0.25) between the OSTs of the right and left eye. On the contrary, the eye affected by a malignant lesion was significantly warmer (P value < 0.0001) than the contralateral, where the lesion was located. This new procedure demonstrated its reliability; it is featured by simplicity, immediacy, modularity, and genericity. The latter point is extremely precious as thermography has been used, in the last decades, in different clinical applications.
- 14 March 2018
- Published by Springer Nature in Medical & Biological Engineering & Computing
- Vol. 56 (10) , 1747-1756
A novel image processing procedure for thermographic image analysis
The imaging procedure shown in this paper has been developed for processing thermographic images, measuring the ocular surface temperature (OST) and visualizing the ocular thermal maps in a fast, reliable, and reproducible way. The strength of this new method is that the measured OSTs do not depend on the ocular geometry; hence, it is possible to compare the ocular profiles belonging to the same subject (right and left eye) as well as to different populations. In this paper, the developed procedure is applied on two subjects’ eyes: a healthy case and another affected by an ocular malignant lesion. However, the method has already been tested on a bigger group of subjects for clinical purpose. For demonstrating the potentiality of this method, both intra- and inter-examiner repeatability were investigated in terms of coefficients of repeatability (COR). All OST indices showed repeatability with small intra-examiner (%COR 0.06–0.80) and inter-examiner variability (%COR 0.03–0.94). Measured OSTs and thermal maps clearly showed the clinical condition of the eyes investigated. The subject with no ocular pathology had no significant difference (P value = 0.25) between the OSTs of the right and left eye. On the contrary, the eye affected by a malignant lesion was significantly warmer (P value < 0.0001) than the contralateral, where the lesion was located. This new procedure demonstrated its reliability; it is featured by simplicity, immediacy, modularity, and genericity. The latter point is extremely precious as thermography has been used, in the last decades, in different clinical applications.
- 26 July 2017
- Published by IOP Publishing in Physiological Measurement
- Vol. 38 (8) , 1503-1512
Ocular surface temperature in patients with evaporative and aqueous-deficient dry eyes: a thermographic approach
Objective: In recent decades infrared thermography (IRT) has facilitated accurate quantitative measurements of the ocular surface temperature (OST), applying a non-invasive procedure. The objective of this work was to develop a procedure based on IRT, which allows characterizing of the cooling of the ocular surface of patients suffering from dry eye syndrome, and distinguishing among patients suffering from aqueous deficient dry eye (ADDE) and evaporative dry eyes (EDE). Approach : All patients examined (34 females and 4 males, 23–84 years) were divided into two groups according to their Schirmer I result (⩽ 7 mm for ADDE and > 7 mm for EDE), and the OST was recorded for 7 s at 30 Hz. For each acquisition, the temperatures of the central cornea (CC) as well as those of both temporal and nasal canthi were investigated. Main results : Findings showed that the maximum temperature variation (up to 0.75 ± 0.29 °C) was at the CC for both groups. Furthermore, patients suffering from EDE tended to have a higher initial OST than those with ADDE, explained by the greater quantity of the tear film, evenly distributed over the entire ocular surface, keeping the OST higher initially. Results also showed that EDE patients had an average cooling rate higher than those suffering from ADDE, confirming the excessive evaporation of the tear film. Significance : Ocular thermography paves the way to become an effective tool for differentiating between the two different etiologies of dry eye syndrome.
- 26 July 2017
- Published by IOP Publishing in Physiological Measurement
- Vol. 38 (8) , 1503-1512
Ocular surface temperature in patients with evaporative and aqueous-deficient dry eyes: a thermographic approach
Objective: In recent decades infrared thermography (IRT) has facilitated accurate quantitative measurements of the ocular surface temperature (OST), applying a non-invasive procedure. The objective of this work was to develop a procedure based on IRT, which allows characterizing of the cooling of the ocular surface of patients suffering from dry eye syndrome, and distinguishing among patients suffering from aqueous deficient dry eye (ADDE) and evaporative dry eyes (EDE). Approach : All patients examined (34 females and 4 males, 23–84 years) were divided into two groups according to their Schirmer I result (⩽ 7 mm for ADDE and > 7 mm for EDE), and the OST was recorded for 7 s at 30 Hz. For each acquisition, the temperatures of the central cornea (CC) as well as those of both temporal and nasal canthi were investigated. Main results : Findings showed that the maximum temperature variation (up to 0.75 ± 0.29 °C) was at the CC for both groups. Furthermore, patients suffering from EDE tended to have a higher initial OST than those with ADDE, explained by the greater quantity of the tear film, evenly distributed over the entire ocular surface, keeping the OST higher initially. Results also showed that EDE patients had an average cooling rate higher than those suffering from ADDE, confirming the excessive evaporation of the tear film. Significance : Ocular thermography paves the way to become an effective tool for differentiating between the two different etiologies of dry eye syndrome.
- 1 April 2016
- Published by SAGE Publications in Journal of Applied Biomaterials & Functional Materials
- Vol. 14 (2) , 163-170
Investigation into the Elastic Properties of ex vivo Porcine Corneas Subjected to Inflation Test after Cross-Linking Treatment
Background: The aim of this work was to evaluate the effect of cross-linking (CXL) on ex vivo porcine corneal elastic properties, using an inflation procedure. Methods: Twelve corneas were subjected to standard CXL (370 nm, 3 mW/cm2, 30 minutes), while 12 were used as controls. Corneal thickness was measured by Visante optical coherence tomography, before and immediately after treatment, and before inflation test. Both intraocular pressure and radial apical cornea displacement were measured during inflation. Stress-strain curves were obtained by applying the linear shell theory. The elastic modulus was evaluated by calculating the slope of the stress-strain curves. Results: Results showed a statistically significant increase in elastic modulus (p<0.0001), with a mean of 3,868 ± 502 kPa for cross-linked corneas and 2,727 ± 238 kPa for untreated corneas, when subjected to high pressure (40-60 kPa). CXL significantly increased porcine cornea stiffness by about 42%. Findings did not show any significant difference within the physiological range of pressure (2-4 kPa). Conclusions: The inflation test has been proven to be a valuable tool for the investigation of corneal biomechanics, maintaining both integrity and geometry of corneal tissue.
- 1 April 2016
- Published by SAGE Publications in Journal of Applied Biomaterials & Functional Materials
- Vol. 14 (2) , 163-170
Investigation into the Elastic Properties of ex vivo Porcine Corneas Subjected to Inflation Test after Cross-Linking Treatment
Background: The aim of this work was to evaluate the effect of cross-linking (CXL) on ex vivo porcine corneal elastic properties, using an inflation procedure. Methods: Twelve corneas were subjected to standard CXL (370 nm, 3 mW/cm2, 30 minutes), while 12 were used as controls. Corneal thickness was measured by Visante optical coherence tomography, before and immediately after treatment, and before inflation test. Both intraocular pressure and radial apical cornea displacement were measured during inflation. Stress-strain curves were obtained by applying the linear shell theory. The elastic modulus was evaluated by calculating the slope of the stress-strain curves. Results: Results showed a statistically significant increase in elastic modulus (p<0.0001), with a mean of 3,868 ± 502 kPa for cross-linked corneas and 2,727 ± 238 kPa for untreated corneas, when subjected to high pressure (40-60 kPa). CXL significantly increased porcine cornea stiffness by about 42%. Findings did not show any significant difference within the physiological range of pressure (2-4 kPa). Conclusions: The inflation test has been proven to be a valuable tool for the investigation of corneal biomechanics, maintaining both integrity and geometry of corneal tissue.
- 1 March 2015
- Published by Wolters Kluwer Health in Cornea
- Vol. 34 (3) , 323-327
In Vivo Thermographic Analysis of the Corneal Surface in Keratoconic Patients Undergoing Riboflavin–UV-A Accelerated Cross-Linking
Purpose: To assess corneal thermal profile during combined riboflavin and accelerated UV corneal collagen cross-linking (A-CXL) using in vivo surface thermographic analysis. Methods: In this open-label, nonrandomized, prospective pilot study, 28 eyes of 28 patients were included. The study was conduced at the Department of Surgery and Translational Medicine, University of Florence, Italy, in collaboration with the Ophthalmic Operative Unit of Siena University, Italy. All patients underwent high-fluence A-CXL in pulsed light and continuous light UV-A exposure at 30 and 18 mW/cm2. Patients were divided into 4 groups: 7 for continuous light A-CXL, 7 for pulsed light A-CXL at 30 mW/cm2 with 7.2 J energy, 7 for continuous light A-CXL, and 7 for pulsed light A-CXL at 18 mW/cm2 with 5.4 J energy. Corneal surface temperature measurements were recorded using an infrared FLIR thermocamera (FLIR 320A; FLIR Systems). Corneal temperature values were detected in the surface area exposed to UV-A light irradiation, selecting it in the acquired thermographic image. The maximum temperature value detected in the area studied was recorded and considered for comparative analysis. Results: Infrared thermocamera measurements of the corneal surface during A-CXL treatments showed an average temperature of 31.5°C during the entire procedure in all groups and UV-A powers (30 mW/cm2 at 7.2 J/cm2 and 18 mW/cm2 at 5.4 J/cm2) and light exposure modality remained under the threshold of collagen thermal injury. Conclusions: Accelerated corneal collagen cross-linking did not cause thermal rise over the threshold of thermal injury to the corneal surface, demonstrating a safe thermal profile both at 30 mW/cm2 with 7.2 J and 18 mW/cm2 with 5.4 J energy dose.
- 1 March 2015
- Published by Wolters Kluwer Health in Cornea
- Vol. 34 (3) , 323-327
In Vivo Thermographic Analysis of the Corneal Surface in Keratoconic Patients Undergoing Riboflavin–UV-A Accelerated Cross-Linking
Purpose: To assess corneal thermal profile during combined riboflavin and accelerated UV corneal collagen cross-linking (A-CXL) using in vivo surface thermographic analysis. Methods: In this open-label, nonrandomized, prospective pilot study, 28 eyes of 28 patients were included. The study was conduced at the Department of Surgery and Translational Medicine, University of Florence, Italy, in collaboration with the Ophthalmic Operative Unit of Siena University, Italy. All patients underwent high-fluence A-CXL in pulsed light and continuous light UV-A exposure at 30 and 18 mW/cm2. Patients were divided into 4 groups: 7 for continuous light A-CXL, 7 for pulsed light A-CXL at 30 mW/cm2 with 7.2 J energy, 7 for continuous light A-CXL, and 7 for pulsed light A-CXL at 18 mW/cm2 with 5.4 J energy. Corneal surface temperature measurements were recorded using an infrared FLIR thermocamera (FLIR 320A; FLIR Systems). Corneal temperature values were detected in the surface area exposed to UV-A light irradiation, selecting it in the acquired thermographic image. The maximum temperature value detected in the area studied was recorded and considered for comparative analysis. Results: Infrared thermocamera measurements of the corneal surface during A-CXL treatments showed an average temperature of 31.5°C during the entire procedure in all groups and UV-A powers (30 mW/cm2 at 7.2 J/cm2 and 18 mW/cm2 at 5.4 J/cm2) and light exposure modality remained under the threshold of collagen thermal injury. Conclusions: Accelerated corneal collagen cross-linking did not cause thermal rise over the threshold of thermal injury to the corneal surface, demonstrating a safe thermal profile both at 30 mW/cm2 with 7.2 J and 18 mW/cm2 with 5.4 J energy dose.
- Open Access
- 11 November 2014
- Published by Wiley in Journal of Ophthalmology
- Vol. 2014, 1-6
Ocular Surface Temperature in Age-Related Macular Degeneration
Background. The aim of this study is to investigate the ocular thermographic profiles in age-related macular degeneration (AMD) eyes and age-matched controls to detect possible hemodynamic abnormalities, which could be involved in the pathogenesis of the disease.Methods. 32 eyes with early AMD, 37 eyes with atrophic AMD, 30 eyes affected by untreated neovascular AMD, and 43 eyes with fibrotic AMD were included. The control group consisted of 44 healthy eyes. Exclusion criteria were represented by any other ocular diseases other than AMD, tear film abnormalities, systemic cardiovascular abnormalities, diabetes mellitus, and a body temperature higher than 37.5°C. A total of 186 eyes without pupil dilation were investigated by infrared thermography (FLIR A320). The ocular surface temperature (OST) of three ocular points was calculated by means of an image processing technique from the infrared images. Two-sample-test and one-way analysis of variance (ANOVA) test were used for statistical analyses.Results. ANOVA analyses showed no significant differences among AMD groups (value ). OST in AMD patients was significantly lower than in controls ().Conclusions. Considering the possible relationship between ocular blood flow and OST, these findings might support the central role of ischemia in the pathogenesis of AMD.- 11 November 2014
- Published by Wiley in Journal of Ophthalmology
- Vol. 2014, 1-6
Open AccessOcular Surface Temperature in Age-Related Macular Degeneration
Background. The aim of this study is to investigate the ocular thermographic profiles in age-related macular degeneration (AMD) eyes and age-matched controls to detect possible hemodynamic abnormalities, which could be involved in the pathogenesis of the disease.Methods. 32 eyes with early AMD, 37 eyes with atrophic AMD, 30 eyes affected by untreated neovascular AMD, and 43 eyes with fibrotic AMD were included. The control group consisted of 44 healthy eyes. Exclusion criteria were represented by any other ocular diseases other than AMD, tear film abnormalities, systemic cardiovascular abnormalities, diabetes mellitus, and a body temperature higher than 37.5°C. A total of 186 eyes without pupil dilation were investigated by infrared thermography (FLIR A320). The ocular surface temperature (OST) of three ocular points was calculated by means of an image processing technique from the infrared images. Two-sample-test and one-way analysis of variance (ANOVA) test were used for statistical analyses.Results. ANOVA analyses showed no significant differences among AMD groups (value ). OST in AMD patients was significantly lower than in controls ().Conclusions. Considering the possible relationship between ocular blood flow and OST, these findings might support the central role of ischemia in the pathogenesis of AMD. - 1 June 2014
- Published by Elsevier in Journal of the Mechanical Behavior of Biomedical Materials
- Vol. 34, 1-7
Analysis and comparison of clutch techniques of two dental implants
- 1 June 2014
- Published by Elsevier in Journal of the Mechanical Behavior of Biomedical Materials
- Vol. 34, 1-7
Analysis and comparison of clutch techniques of two dental implants
- 19 November 2012
- Published by SAGE Publications in Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine
- Vol. 227 (3) , 334-342
Investigations on the viscoelastic behaviour of a human healthy heel pad: In vivo compression tests and numerical analysis
The aim of this study was to investigate the viscoelastic behaviour of the human heel pad by comparing the stress–relaxation curves obtained from a compression device used on an in vivo heel pad with those obtained from a three-dimensional computer-based subject-specific heel pad model subjected to external compression. The three-dimensional model was based on the anatomy revealed by magnetic resonance imaging of a 31-year-old healthy female. The calcaneal fat pad tissue was described with a viscohyperelastic model, while a fibre-reinforced hyperelastic model was formulated for the skin. All numerical analyses were performed to interpret the mechanical response of heel tissues, with loading conditions and displacement rate in agreement with experimental tests. The heel tissues showed a non-linear, viscoelastic behaviour described by characteristic hysteretic curves, stress–relaxation and viscous recovery phenomena. The reliability of the investigations was validated by the interpretation of the mechanical response of heel tissues under the application of three pistons with diameter of 15, 20 and 40 mm, at the same displacement rate of about 1.7 mm/s. The maximum and minimum relative errors were found to be less than 0.95 and 0.064, respectively.
- 19 November 2012
- Published by SAGE Publications in Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine
- Vol. 227 (3) , 334-342
Investigations on the viscoelastic behaviour of a human healthy heel pad: In vivo compression tests and numerical analysis
The aim of this study was to investigate the viscoelastic behaviour of the human heel pad by comparing the stress–relaxation curves obtained from a compression device used on an in vivo heel pad with those obtained from a three-dimensional computer-based subject-specific heel pad model subjected to external compression. The three-dimensional model was based on the anatomy revealed by magnetic resonance imaging of a 31-year-old healthy female. The calcaneal fat pad tissue was described with a viscohyperelastic model, while a fibre-reinforced hyperelastic model was formulated for the skin. All numerical analyses were performed to interpret the mechanical response of heel tissues, with loading conditions and displacement rate in agreement with experimental tests. The heel tissues showed a non-linear, viscoelastic behaviour described by characteristic hysteretic curves, stress–relaxation and viscous recovery phenomena. The reliability of the investigations was validated by the interpretation of the mechanical response of heel tissues under the application of three pistons with diameter of 15, 20 and 40 mm, at the same displacement rate of about 1.7 mm/s. The maximum and minimum relative errors were found to be less than 0.95 and 0.064, respectively.
- 1 January 2009
- Vol. 19 (1) , 19-26
Clinical performance diagnosing alleged exposure to falanga--a phantom study.
Falanga torture involves repetitive blunt trauma to the soles of the feet and typically leaves few detectable changes. Reduced elasticity in the heel pads has been reported as characteristic sequelae and palpatory testing of heel pad elasticity is therefore part of medicolegal assessment of alleged torture victims. The goal was to test the accuracy of two experienced investigators in determining whether a heel pad model was soft, medium or hard. The skin-to-bone distance in the models varied within the human range. Two blinded investigators independently palpated nine different heel pad models with three different elasticities combined with three different skin-to-bone distances in five consecutive trials and categorized the models as soft, medium or hard. Two experienced investigators were able to identify three known elasticities correctly in approximately two thirds of the cases. The skin-to-bone distance affected the accuracy. The use of clinical examination in documenting alleged exposure to torture warrants a high diagnostic accuracy of the applied tests. The study implies that palpatory testing of the human heel pad may not meet this demand. It is therefore recommended that a device able to perform an accurate measurement of the viscous-elastic properties of the heel pad be developed.
- 1 January 2009
- Vol. 19 (1) , 19-26
Clinical performance diagnosing alleged exposure to falanga--a phantom study.
Falanga torture involves repetitive blunt trauma to the soles of the feet and typically leaves few detectable changes. Reduced elasticity in the heel pads has been reported as characteristic sequelae and palpatory testing of heel pad elasticity is therefore part of medicolegal assessment of alleged torture victims. The goal was to test the accuracy of two experienced investigators in determining whether a heel pad model was soft, medium or hard. The skin-to-bone distance in the models varied within the human range. Two blinded investigators independently palpated nine different heel pad models with three different elasticities combined with three different skin-to-bone distances in five consecutive trials and categorized the models as soft, medium or hard. Two experienced investigators were able to identify three known elasticities correctly in approximately two thirds of the cases. The skin-to-bone distance affected the accuracy. The use of clinical examination in documenting alleged exposure to torture warrants a high diagnostic accuracy of the applied tests. The study implies that palpatory testing of the human heel pad may not meet this demand. It is therefore recommended that a device able to perform an accurate measurement of the viscous-elastic properties of the heel pad be developed.