Hideki Oshima
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Hideki Oshima has a total of 73 co-authors. Here are the top co-authors by number of shared publications:
- Akihiko Usui
Department of Cardiac Surgery, Nagoya University Graduate School of Medicine, Nagoya, Japan
14 shared publications - Yoshimori Araki
Department of Cardiac Surgery, Toyota Kosei Hospital, Toyota, Aichi, Japan
9 shared publications - Yuji Narita
Department of Cardiac Surgery, Nagoya University Graduate School of Medicine, Nagoya, Japan
9 shared publications Akihiko Usui
Department of Cardiac Surgery, Nagoya University Graduate School of Medicine, 65 Tsurumaicho, Showa, Nagoya, Aichi, 466-8550, Japan
8 shared publications- Yuichi Ueda
Department of Cardiothoracic Surgery, Nagoya University Graduate School of Medicine, 65 Tsurumai-cho, Showa-ku, Nagoya, Aichi 466-8550, Japan
7 shared publications - Masato Mutsuga
Nagoya University Graduate School of Medicine
5 shared publications
Latest Publications
- Open Access
- 24 November 2018
- Published by Japanese Circulation Society in Circulation Journal
- Vol. 82 (12) , 2998-3004
Strategy of Cardiovascular Surgery for Patients With Dementia as Evaluated by Mini-Mental State Examination
Japan's largest platform for academic e-journals: J-STAGE is a full text database for reviewed academic papers published by Japanese societies
- 24 November 2018
- Published by Japanese Circulation Society in Circulation Journal
- Vol. 82 (12) , 2998-3004
Open AccessStrategy of Cardiovascular Surgery for Patients With Dementia as Evaluated by Mini-Mental State Examination
Japan's largest platform for academic e-journals: J-STAGE is a full text database for reviewed academic papers published by Japanese societies
- 9 February 2018
- Published by Springer Nature in Journal of Artificial Organs
- Vol. 21 (2) , 125-131
Transcatheter heart valve for aortic valve implantation: republication of the article published in the Japanese Journal of Artificial Organs
This review was created based on a translation of the Japanese review first reported in the Japanese Journal of Artificial Organs in 2015 (vol. 44, no. 3, pp. 136–140), with some modifications.
- 9 February 2018
- Published by Springer Nature in Journal of Artificial Organs
- Vol. 21 (2) , 125-131
Transcatheter heart valve for aortic valve implantation: republication of the article published in the Japanese Journal of Artificial Organs
This review was created based on a translation of the Japanese review first reported in the Japanese Journal of Artificial Organs in 2015 (vol. 44, no. 3, pp. 136–140), with some modifications.
- 1 September 2017
- Published by Elsevier in The Annals of Thoracic Surgery
- Vol. 104 (3) , 1099
Reply
- 7 July 2017
- Published by Springer Nature in General Thoracic and Cardiovascular Surgery
- Vol. 65 (10) , 575-580
Collaborative operation with cardiovascular surgeons in general thoracic surgery
- 7 July 2017
- Published by Springer Nature in General Thoracic and Cardiovascular Surgery
- Vol. 65 (10) , 575-580
Collaborative operation with cardiovascular surgeons in general thoracic surgery
- Open Access
- 20 June 2016
- Published by Oxford University Press (OUP) in Interactive CardioVascular and Thoracic Surgery
- Vol. 23 (4) , 668-670
Non-anastomotic rupture of the Valsalva graft 6 years after undergoing the Bentall procedure
A 72-year old man with an unruptured aneurysm of the right sinus of Valsalva and aortic insufficiency underwent aortic root replacement using a valved composite graft created with a 28-mm woven Dacron graft (Gelweave Valsalva™ graft, Vascutek Terumo, Renfrewshire, Scotland) and a 25-mm stented bioprosthetic aortic valve (Carpentier-Edwards PERIMOUNT pericardial bioprosthesis, Edwards Lifesciences, Irvine, CA, USA). His postoperative course was uneventful. He had undergone a follow-up CT scan once a year. Although no abnormal signs were detected 5 years after surgery, a CT scan performed in the sixth postoperative year revealed an aortic false aneurysm around the Dacron graft. The false aneurysm enlarged over time and he underwent elective surgery. Two small holes were identified in the ‘sinus’ portion of the Valsalva graft. The holes were located at the site of the vascular prosthesis corresponding to the level sandwiched between the strut of the bioprosthetic aortic valve and the main pulmonary artery. Therefore, the vascular prosthesis could be exposed to persistent pulsatile contact with the strut resulting from pulsation of the pulmonary artery. This contact/friction might result in fraying of the fabric of the vascular prosthesis, finally leading to non-anastomotic rupture of the Valsalva graft.
- 20 June 2016
- Published by Oxford University Press (OUP) in Interactive CardioVascular and Thoracic Surgery
- Vol. 23 (4) , 668-670
Open AccessNon-anastomotic rupture of the Valsalva graft 6 years after undergoing the Bentall procedure
A 72-year old man with an unruptured aneurysm of the right sinus of Valsalva and aortic insufficiency underwent aortic root replacement using a valved composite graft created with a 28-mm woven Dacron graft (Gelweave Valsalva™ graft, Vascutek Terumo, Renfrewshire, Scotland) and a 25-mm stented bioprosthetic aortic valve (Carpentier-Edwards PERIMOUNT pericardial bioprosthesis, Edwards Lifesciences, Irvine, CA, USA). His postoperative course was uneventful. He had undergone a follow-up CT scan once a year. Although no abnormal signs were detected 5 years after surgery, a CT scan performed in the sixth postoperative year revealed an aortic false aneurysm around the Dacron graft. The false aneurysm enlarged over time and he underwent elective surgery. Two small holes were identified in the ‘sinus’ portion of the Valsalva graft. The holes were located at the site of the vascular prosthesis corresponding to the level sandwiched between the strut of the bioprosthetic aortic valve and the main pulmonary artery. Therefore, the vascular prosthesis could be exposed to persistent pulsatile contact with the strut resulting from pulsation of the pulmonary artery. This contact/friction might result in fraying of the fabric of the vascular prosthesis, finally leading to non-anastomotic rupture of the Valsalva graft.
- 1 April 2016
- Vol. 69 (4) , 321-4
[Aortic Valve Replacement of Quadricuspid Valve with Regurgitation].
Congenital quadricuspid aortic valve is a very rare malformation. In most cases it has been found incidentally at aortic valve surgery or at autopsy. It frequently causes aortic regurgitation, which may become manifest in adulthood and require surgical treatment. We reported 4 cases of aortic regurgitation with quadricuspid aortic valve. In all cases, aortic valve replacement was preformed with prosthetic valve, and their postoperative courses were uneventful. Two were Hurwitz's classification type b, one was type a and the last patient was type c. Although quadricuspid aortic valve is a rare anomaly, its potential for severe valve failure in adulthood should be kept in mind.
- 1 April 2016
- Vol. 69 (4) , 321-4
[Aortic Valve Replacement of Quadricuspid Valve with Regurgitation].
Congenital quadricuspid aortic valve is a very rare malformation. In most cases it has been found incidentally at aortic valve surgery or at autopsy. It frequently causes aortic regurgitation, which may become manifest in adulthood and require surgical treatment. We reported 4 cases of aortic regurgitation with quadricuspid aortic valve. In all cases, aortic valve replacement was preformed with prosthetic valve, and their postoperative courses were uneventful. Two were Hurwitz's classification type b, one was type a and the last patient was type c. Although quadricuspid aortic valve is a rare anomaly, its potential for severe valve failure in adulthood should be kept in mind.
- Open Access
- 30 March 2016
- Published by Oxford University Press (OUP) in Interactive CardioVascular and Thoracic Surgery
- Vol. 23 (1) , 142-149
Predictors of early graft failure after coronary artery bypass grafting for chronic total occlusion
Little is known regarding the transit-time flow measurement (TTFM) variables in grafts anastomosed to chronically totally occluded vessels (CTOs). We aimed to establish the TTFM cut-off values for detecting graft failure in bypass grafts anastomosed to chronically totally occluded arteries and clarify the relationship between early graft failure and the grade of collateral circulation/regional wall motion of the CTO territory. Among 491 patients who underwent isolated coronary artery bypass grafting (CABG) from 2009 to 2015, 196 cases with CTOs underwent postoperative coronary angiography within 1 month after CABG. Two hundred and forty-one CTOs in all patients were examined. Thirty-two CTOs (13%) were not bypassed and 214 conduits were anastomosed to CTOs and underwent intraoperative TTFM. Arterial conduits and saphenous vein grafts (SVGs) were used in 102 and 112 cases, respectively. Among the arterial conduit procedures that were performed, 78 involved the left internal thoracic artery (LITA), 10 involved the right internal thoracic artery (RITA) and 14 involved the right gastroepiploic artery (rGEA). Any graft showing Fitzgibbon type B or O lesions on angiography was considered to be a failing graft. The insufficiency rates for LITA, RITA, rGEA and SVG procedures were 5.1, 10, 14.3 and 7.1%, respectively. The TTFM variables recorded in failing grafts had a significantly lower mean flow (Qmean) and higher pulsatility index (PI) compared with patent grafts. Furthermore, akinetic or dyskinetic wall motion in the territory of bypassed CTOs was observed at a significantly higher rate in failing grafts. A multivariable regression analysis and receiver operating characteristic analysis revealed good predictors of early graft failure as follows: a Qmean value of < 11.5 ml/min for arterial conduits, a PI value of >5.85 and akinetic/dyskinetic wall motion in the CTO territory for SVGs. The Rentrop collateral grade was not associated with early graft failure. The Qmean value and PI value by the TTFM are useful to detect early graft failure in conduits anastomosed to CTOs. The collateral grade is not associated with graft failure; however, bypass grafting to CTOs with akinetic/dyskinetic wall motion should be carefully considered.
- 30 March 2016
- Published by Oxford University Press (OUP) in Interactive CardioVascular and Thoracic Surgery
- Vol. 23 (1) , 142-149
Open AccessPredictors of early graft failure after coronary artery bypass grafting for chronic total occlusion
Little is known regarding the transit-time flow measurement (TTFM) variables in grafts anastomosed to chronically totally occluded vessels (CTOs). We aimed to establish the TTFM cut-off values for detecting graft failure in bypass grafts anastomosed to chronically totally occluded arteries and clarify the relationship between early graft failure and the grade of collateral circulation/regional wall motion of the CTO territory. Among 491 patients who underwent isolated coronary artery bypass grafting (CABG) from 2009 to 2015, 196 cases with CTOs underwent postoperative coronary angiography within 1 month after CABG. Two hundred and forty-one CTOs in all patients were examined. Thirty-two CTOs (13%) were not bypassed and 214 conduits were anastomosed to CTOs and underwent intraoperative TTFM. Arterial conduits and saphenous vein grafts (SVGs) were used in 102 and 112 cases, respectively. Among the arterial conduit procedures that were performed, 78 involved the left internal thoracic artery (LITA), 10 involved the right internal thoracic artery (RITA) and 14 involved the right gastroepiploic artery (rGEA). Any graft showing Fitzgibbon type B or O lesions on angiography was considered to be a failing graft. The insufficiency rates for LITA, RITA, rGEA and SVG procedures were 5.1, 10, 14.3 and 7.1%, respectively. The TTFM variables recorded in failing grafts had a significantly lower mean flow (Qmean) and higher pulsatility index (PI) compared with patent grafts. Furthermore, akinetic or dyskinetic wall motion in the territory of bypassed CTOs was observed at a significantly higher rate in failing grafts. A multivariable regression analysis and receiver operating characteristic analysis revealed good predictors of early graft failure as follows: a Qmean value of < 11.5 ml/min for arterial conduits, a PI value of >5.85 and akinetic/dyskinetic wall motion in the CTO territory for SVGs. The Rentrop collateral grade was not associated with early graft failure. The Qmean value and PI value by the TTFM are useful to detect early graft failure in conduits anastomosed to CTOs. The collateral grade is not associated with graft failure; however, bypass grafting to CTOs with akinetic/dyskinetic wall motion should be carefully considered.
- 1 June 2015
- Published by Elsevier in The Annals of Thoracic Surgery
- Vol. 99 (6) , 2017-2023
Impact of Surgical Stroke on the Early and Late Outcomes After Thoracic Aortic Operations
- 1 June 2015
- Published by Elsevier in The Annals of Thoracic Surgery
- Vol. 99 (6) , 2017-2023
Impact of Surgical Stroke on the Early and Late Outcomes After Thoracic Aortic Operations
- 1 November 2014
- Published by Elsevier in The Journal of Thoracic and Cardiovascular Surgery
- Vol. 148 (5) , 2422-2424
Usefulness of bridging thoracic endovascular aortic repair and sac irrigation followed by open repair in patients with mycotic thoracic aortic aneurysms
- 1 November 2014
- Published by Elsevier in The Journal of Thoracic and Cardiovascular Surgery
- Vol. 148 (5) , 2422-2424
Usefulness of bridging thoracic endovascular aortic repair and sac irrigation followed by open repair in patients with mycotic thoracic aortic aneurysms
- 1 October 2013
- Vol. 66 (11) , 960-4
[Surgical strategy for extended aortic arch aneurysm].
The management of an extended aortic arch aneurysm still remains a clinical challenge. Open surgery can be invasive for the patients with comorbidities. Since thoracic endovascular aneurysm repair (TEVAR) was introduced, hybrid therapy has been applied for the extended arch aneurysm. From 1997 to 2013, 379 patients have undergone aortic arch surgery. Of those, 241 patients of non-dissection aneurysm were studied. Open surgical repair with L-shaped thoracotomy was done in 28 patients, frozen elephant trunk( FET) in 30 patients, long elephant trunk( LET) with 2nd TEVAR in 21 patients, debranched TEVAR in 10 patients and standard arch grafting in 152 patients as a control group. The brain infarction rate was high in debranched TEVAR (40%) and L-shaped group (25%). The paraplegia rate was high in FET group( 23.3%). The respiratory failure rate was high in the L-shaped group and the LET group. In-hospital mortality was 0.0% in the L-shaped group, 6.7% in the FET group, 4.8% in the LET group, 20% in the debranched group and 0.7% in the control group. The debranched TEVAR group is our early experience, and the recent outcomes of this procedure have improved. The management of extended aortic arch aneurysm has changed with hybrid approach combined with TEVAR. Open repair is still the gold standard, but hybrid therapy is used for high-risk patients. Off-pump debranched TEVAR tends to be applied for extended arch aneurysm.
- 1 October 2013
- Vol. 66 (11) , 960-4
[Surgical strategy for extended aortic arch aneurysm].
The management of an extended aortic arch aneurysm still remains a clinical challenge. Open surgery can be invasive for the patients with comorbidities. Since thoracic endovascular aneurysm repair (TEVAR) was introduced, hybrid therapy has been applied for the extended arch aneurysm. From 1997 to 2013, 379 patients have undergone aortic arch surgery. Of those, 241 patients of non-dissection aneurysm were studied. Open surgical repair with L-shaped thoracotomy was done in 28 patients, frozen elephant trunk( FET) in 30 patients, long elephant trunk( LET) with 2nd TEVAR in 21 patients, debranched TEVAR in 10 patients and standard arch grafting in 152 patients as a control group. The brain infarction rate was high in debranched TEVAR (40%) and L-shaped group (25%). The paraplegia rate was high in FET group( 23.3%). The respiratory failure rate was high in the L-shaped group and the LET group. In-hospital mortality was 0.0% in the L-shaped group, 6.7% in the FET group, 4.8% in the LET group, 20% in the debranched group and 0.7% in the control group. The debranched TEVAR group is our early experience, and the recent outcomes of this procedure have improved. The management of extended aortic arch aneurysm has changed with hybrid approach combined with TEVAR. Open repair is still the gold standard, but hybrid therapy is used for high-risk patients. Off-pump debranched TEVAR tends to be applied for extended arch aneurysm.