Huashan Li
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Huashan Li has a total of 36 co-authors. Here are the top co-authors by number of shared publications:
- Xianbiao Bu
School of Energy Science and Engineering, University of Science and Technology of China, Guangzhou, China
10 shared publications Lingbao Wang
8 shared publicationsWeibin Ma
4 shared publications- Fei Cao
College of Mechanical and Electrical Engineering, Hohai University, Changzhou 213022, China
3 shared publications Xianbiao Bu
Guangzhou Institute of Energy Conversion Chinese Academy of Sciences Guangzhou 510640 China
3 shared publicationsHanzhi Wang
2 shared publications
Latest Publications
- Open Access
- 22 June 2024
- Published by Elsevier in Case Studies in Thermal Engineering
- Vol. 60
Performance analysis of zeotropic organic Rankine cycle with a vapor-liquid injector
- 22 June 2024
- Published by Elsevier in Case Studies in Thermal Engineering
- Vol. 60
Open AccessPerformance analysis of zeotropic organic Rankine cycle with a vapor-liquid injector
- Open Access
- 20 April 2023
- Published by Springer Nature in Geothermal Energy
- Vol. 11 (1) , 1-28
Experimental study on convective heat transfer of an open-loop borehole heat exchanger
Open-loop borehole heat exchanger (OBHE) is a single well geothermal heat exchanger with an open-loop structure that can realize the geothermal energy extraction without mining the geothermal water. In this paper, a sandbox experiment is designed to simulate the convective heat transfer process in the reservoir area of OBHE. The mechanism of convective heat transfer in the reservoir area is studied, and the key factors that affect the convection heat transfer intensity are analyzed. The results show that the convection heat transfer of OBHE in the reservoir area is affected by both the driving effect of fluid flow inside the screen tube and the buoyancy effect. In the forward flow mode, the two effects have the opposite direction. While in the backward mode, the two effects have the same direction. The backward flow mode is more conducive to convective heat transfer. In addition, many factors influencing significantly the convective heat transfer of OBHE include inlet temperature, inlet flow rate, reservoir temperature, fluid flow direction and inner tube diameter.
- 20 April 2023
- Published by Springer Nature in Geothermal Energy
- Vol. 11 (1) , 1-28
Open AccessExperimental study on convective heat transfer of an open-loop borehole heat exchanger
Open-loop borehole heat exchanger (OBHE) is a single well geothermal heat exchanger with an open-loop structure that can realize the geothermal energy extraction without mining the geothermal water. In this paper, a sandbox experiment is designed to simulate the convective heat transfer process in the reservoir area of OBHE. The mechanism of convective heat transfer in the reservoir area is studied, and the key factors that affect the convection heat transfer intensity are analyzed. The results show that the convection heat transfer of OBHE in the reservoir area is affected by both the driving effect of fluid flow inside the screen tube and the buoyancy effect. In the forward flow mode, the two effects have the opposite direction. While in the backward mode, the two effects have the same direction. The backward flow mode is more conducive to convective heat transfer. In addition, many factors influencing significantly the convective heat transfer of OBHE include inlet temperature, inlet flow rate, reservoir temperature, fluid flow direction and inner tube diameter.
- 29 December 2021
- Published by Wiley in Acta Geologica Sinica - English Edition
- Vol. 95 (6) , 1958-1966
Thermo‐economic Investigation of an Enhanced Geothermal System Organic Rankine Cycle and Combined Heating and Power System
As a potentially viable renewable energy, Enhanced Geothermal Systems (EGSs) extract heat from hot dry rock (HDR) reservoirs to produce electricity and heat, which promotes the progress towards carbon peaking and carbon neutralization. The main challenge for EGSs is to reduce the investment cost. In the present study, thermo‐economic investigations of EGS projects are conducted. The effects of geofluid mass flow rate, wellhead temperature and loss rate on the thermo‐economic performance of the EGS organic Rankine cycle (ORC) are studied. A performance comparison between EGS‐ORC and the EGS combined heating and power system (CHP) is presented. Considering the CO2 emission reduction benefits, the influence of carbon emission trading price on the levelized cost of energy (LCOE) is also presented. It is indicated that the geofluid mass flow rate is a critical parameter in dictating the success of a project. Under the assumed typical working conditions, the LCOE of EGS‐ORC and EGS‐CHP systems are 24.72 and 16.1 cents/kWh, respectively. Compared with the EGS‐ORC system, the LCOE of the EGS‐CHP system is reduced by 35%. EGS‐CHP systems have the potential to be economically viable in the future. With carbon emission trading prices of 12.76 USD/ton, the LCOE can be reduced by approximately 8.5%.
- 29 December 2021
- Published by Wiley in Acta Geologica Sinica - English Edition
- Vol. 95 (6) , 1958-1966
Thermo‐economic Investigation of an Enhanced Geothermal System Organic Rankine Cycle and Combined Heating and Power System
As a potentially viable renewable energy, Enhanced Geothermal Systems (EGSs) extract heat from hot dry rock (HDR) reservoirs to produce electricity and heat, which promotes the progress towards carbon peaking and carbon neutralization. The main challenge for EGSs is to reduce the investment cost. In the present study, thermo‐economic investigations of EGS projects are conducted. The effects of geofluid mass flow rate, wellhead temperature and loss rate on the thermo‐economic performance of the EGS organic Rankine cycle (ORC) are studied. A performance comparison between EGS‐ORC and the EGS combined heating and power system (CHP) is presented. Considering the CO2 emission reduction benefits, the influence of carbon emission trading price on the levelized cost of energy (LCOE) is also presented. It is indicated that the geofluid mass flow rate is a critical parameter in dictating the success of a project. Under the assumed typical working conditions, the LCOE of EGS‐ORC and EGS‐CHP systems are 24.72 and 16.1 cents/kWh, respectively. Compared with the EGS‐ORC system, the LCOE of the EGS‐CHP system is reduced by 35%. EGS‐CHP systems have the potential to be economically viable in the future. With carbon emission trading prices of 12.76 USD/ton, the LCOE can be reduced by approximately 8.5%.
- Open Access
- 3 April 2021
- Published by Oxford University Press (OUP) in International Journal of Low-Carbon Technologies
- Vol. 16 (3) , 977-986
Application and discussion on entransy analysis of ammonia/salt absorption heat pump systems
This study investigates the application of the entransy analysis in ammonia/salt absorption heat pump (AHP) systems. The results of the entransy analysis are compared with those of energy analysis and exergy analysis under typical and various operating conditions. Entransy dissipation and exergy loss in each component, as well as coefficient of performance (COP), exergy efficiency and entransy efficiency of systems, are discussed. The changing trends of entransy dissipation in each component are similar under various operating conditions. However, the entransy analysis performs better than the exergy analysis in evaluating the irreversible loss of each component. Moreover, the differences between the exergy analysis and entransy analysis are mainly in absorber, generator and SHE. Especially in the NH3/NaSCN system, the proportion of entransy dissipation in generator is 60.8%, which is almost twice of the proportion of exergy loss (34.9%). In addition, under various operating conditions, entransy efficiency and COP have roughly the same changing trend. Meanwhile, entransy efficiency is more reasonable than exergy efficiency in evaluating the performance of systems under the absorption temperature, which varies from 30°C to 50°C. These comparison results demonstrate that the entransy analysis is appropriate to evaluate the performance of ammonia/salt AHP systems and suitable for analyzing the irreversibility of each component.
- 3 April 2021
- Published by Oxford University Press (OUP) in International Journal of Low-Carbon Technologies
- Vol. 16 (3) , 977-986
Open AccessApplication and discussion on entransy analysis of ammonia/salt absorption heat pump systems
This study investigates the application of the entransy analysis in ammonia/salt absorption heat pump (AHP) systems. The results of the entransy analysis are compared with those of energy analysis and exergy analysis under typical and various operating conditions. Entransy dissipation and exergy loss in each component, as well as coefficient of performance (COP), exergy efficiency and entransy efficiency of systems, are discussed. The changing trends of entransy dissipation in each component are similar under various operating conditions. However, the entransy analysis performs better than the exergy analysis in evaluating the irreversible loss of each component. Moreover, the differences between the exergy analysis and entransy analysis are mainly in absorber, generator and SHE. Especially in the NH3/NaSCN system, the proportion of entransy dissipation in generator is 60.8%, which is almost twice of the proportion of exergy loss (34.9%). In addition, under various operating conditions, entransy efficiency and COP have roughly the same changing trend. Meanwhile, entransy efficiency is more reasonable than exergy efficiency in evaluating the performance of systems under the absorption temperature, which varies from 30°C to 50°C. These comparison results demonstrate that the entransy analysis is appropriate to evaluate the performance of ammonia/salt AHP systems and suitable for analyzing the irreversibility of each component.
- 31 January 2021
- Published by Taylor & Francis in Environmental Technology
- Vol. 43 (15) , 2352-2358
Study on the preparation conditions and degradation performance of an efficient immobilized microbial agent for marine oil pollution
In the process of handling marine oil spills accidents, the biological method has attracted wide attention due to its low cost and no secondary pollution. However, in the process of practical application, there are problems such as low microbial density and great influence of environmental factors when the oil is treated by spraying microorganisms on the sea surface. This study used immobilized microorganism technology to solve the above-mentioned problems. In this study, the bacteria immobilized on cinnamon shell (CS) with good degradation performance were obtained by optimizing preparation conditions. Under the optimal conditions of sodium alginate (SA) concentration of 4.57%, CS concentration of 1.28%, and the CaCl2 concentration of 2.45%, the degradation rate of diesel in 5 days reached 74.04%. The reusability of immobilized microbial agents was further studied. The study designed three cycles of repeated degradation experiments. The results showed that the degradation rate of diesel can still reach 60.12% after three times of reuse, which indicated the reusability of the immobilized microbial agents was excellent. The decrease in degradation rate of diesel was mainly related to the fragmentation of immobilized microbial agents and the decrease in microbial biomass. GRAPHICAL ABSTRACT
- 31 January 2021
- Published by Taylor & Francis in Environmental Technology
- Vol. 43 (15) , 2352-2358
Study on the preparation conditions and degradation performance of an efficient immobilized microbial agent for marine oil pollution
In the process of handling marine oil spills accidents, the biological method has attracted wide attention due to its low cost and no secondary pollution. However, in the process of practical application, there are problems such as low microbial density and great influence of environmental factors when the oil is treated by spraying microorganisms on the sea surface. This study used immobilized microorganism technology to solve the above-mentioned problems. In this study, the bacteria immobilized on cinnamon shell (CS) with good degradation performance were obtained by optimizing preparation conditions. Under the optimal conditions of sodium alginate (SA) concentration of 4.57%, CS concentration of 1.28%, and the CaCl2 concentration of 2.45%, the degradation rate of diesel in 5 days reached 74.04%. The reusability of immobilized microbial agents was further studied. The study designed three cycles of repeated degradation experiments. The results showed that the degradation rate of diesel can still reach 60.12% after three times of reuse, which indicated the reusability of the immobilized microbial agents was excellent. The decrease in degradation rate of diesel was mainly related to the fragmentation of immobilized microbial agents and the decrease in microbial biomass. GRAPHICAL ABSTRACT
- Open Access
- 5 December 2019
- Published by Springer Nature in Geothermal Energy
- Vol. 7 (1) , 1-16
Investigation on geothermal binary-flashing cycle employing zeotropic mixtures as working fluids
The binary-flashing cycle (BFC) is supposed to be a promising technology for geothermal recovery due to the full use of geofluid. For further performance improvement, the potential of using mixtures of a hydrocarbon and a retardant in the BFC system is investigated. R245fa is selected as a retardant and blended with R600 to form zeotropic mixtures. With the thermal efficiency (ηth), exergy efficiency (ηex), net power output per ton geofluid (PRW), and exergy destruction rate (Ed) as evaluation indexes, the flowsheet modeling and optimization are conducted to explore the optimal compositions and operating parameters. It is revealed the optimal mass fraction of R600/R245fa is 0.44/0.56, at which the flammability of R600 is suppressed, the global warming potential (GWP) of R245fa is reduced. The maximum ηex and PRW are higher than those of component fluids. The maximum Ed occurs in the heat exchanger, which should be optimized. The recommended generation pressures are 1200–1430, 1240–1480, 1220–1460, and 1170–1420 kPa, respectively, for R600 mass fraction of 0.2, 0.4, 0.6, and 0.8. In addition, the flashing temperature is also optimized. Although the mixtures do not always yield superior performance, it is still beneficial to apply the mixtures to the BFC system through systematic consideration of safety and environmental friendliness.
- 5 December 2019
- Published by Springer Nature in Geothermal Energy
- Vol. 7 (1) , 1-16
Open AccessInvestigation on geothermal binary-flashing cycle employing zeotropic mixtures as working fluids
The binary-flashing cycle (BFC) is supposed to be a promising technology for geothermal recovery due to the full use of geofluid. For further performance improvement, the potential of using mixtures of a hydrocarbon and a retardant in the BFC system is investigated. R245fa is selected as a retardant and blended with R600 to form zeotropic mixtures. With the thermal efficiency (ηth), exergy efficiency (ηex), net power output per ton geofluid (PRW), and exergy destruction rate (Ed) as evaluation indexes, the flowsheet modeling and optimization are conducted to explore the optimal compositions and operating parameters. It is revealed the optimal mass fraction of R600/R245fa is 0.44/0.56, at which the flammability of R600 is suppressed, the global warming potential (GWP) of R245fa is reduced. The maximum ηex and PRW are higher than those of component fluids. The maximum Ed occurs in the heat exchanger, which should be optimized. The recommended generation pressures are 1200–1430, 1240–1480, 1220–1460, and 1170–1420 kPa, respectively, for R600 mass fraction of 0.2, 0.4, 0.6, and 0.8. In addition, the flashing temperature is also optimized. Although the mixtures do not always yield superior performance, it is still beneficial to apply the mixtures to the BFC system through systematic consideration of safety and environmental friendliness.
- 1 September 2019
- Published by Elsevier in Energy Conversion and Management
- Vol. 196, 614-622
A solar-assisted double absorption heat transformer: Off-design performance and optimum control strategy
- 1 September 2019
- Published by Elsevier in Energy Conversion and Management
- Vol. 196, 614-622
A solar-assisted double absorption heat transformer: Off-design performance and optimum control strategy
- 1 August 2018
- Published by Elsevier in Applied Thermal Engineering
- Vol. 141, 51-60
Performance characteristics and working fluid selection for low-temperature binary-flashing cycle
- 1 August 2018
- Published by Elsevier in Applied Thermal Engineering
- Vol. 141, 51-60
Performance characteristics and working fluid selection for low-temperature binary-flashing cycle