Stefano Agosteo
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Stefano Agosteo has a total of 129 co-authors. Here are the top co-authors by number of shared publications:
A. Pola
Department of Energy, Politecnico di Milano, Milan 20133, Italy
12 shared publications- Davide Bortot
Politecnico di Milano
10 shared publications - Davide Mazzucconi
Politecnico di Milano
8 shared publications P. Colautti
6 shared publicationsA. Fazzi
5 shared publicationsAndrea Pola
5 shared publications
Latest Publications
- Open Access
- 29 September 2026
- Published by Elsevier in SSRN Electronic Journal
Monte Carlo Design and Experimental Test of a Fiber-CoupledLithium-Glass Neutron Spectrometer for Accelerator-Based BoronNeutron Capture Therapy Fields
Accurate neutron spectrometry is required for beam characterization, qualityassurance and dosimetric assessment in accelerator-based Boron Neutron CaptureTherapy (BNCT). Established methods, such as activation foils and Bonnersphere systems, provide reliable fluence and spectrometric information but requiresequential irradiations, post-processing and off-line analysis. Compact detectorsystems able to provide spectrometric information with a simpler measurementworkflow are therefore of practical interest.This work presents the Monte Carlo design and proof-of-concept experimentaltest of a compact neutron spectrometer based on fiber-coupled lithium-glassscintillators embedded in a cylindrical polyethylene moderator with an active lengthof 15cm. The detector response was modelled with FLUKA, including neutrontransport, the 6Li(n,α)3H reaction, scintillation-light production and optical-fiberacceptance. Response matrices were calculated for different moderator radii, andthe 100mm radius configuration was selected for testing at the Nagoya Universityaccelerator-based BNCT facility.The single-detector response was linear over the investigated acceleratoroperating-current range, from 0.2mA to 2mA, and the nozzle/no-nozzle measurements showed sensitivity to beam-line changes. In the nozzle configuration, the unfolded spectrum reproduced the Monte Carlo reference in the epithermal region. After gold-foil calibration, the unfolded total fluence rate was(7.28 ± 0.18) × 10^7 n cm-2 s-1, 5.7% lower than the 1mA reference neutron fluence. This paper shows the first experimental demonstration of an active moderatedspectrometer reconstructing a BNCT neutron spectrum. This spectral-shapeagreement establishes compact active spectrometry as a feasible tool for BNCTbeam characterization, while absolute response calibration remains the mainlimitation.
- 29 September 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessMonte Carlo Design and Experimental Test of a Fiber-CoupledLithium-Glass Neutron Spectrometer for Accelerator-Based BoronNeutron Capture Therapy Fields
Accurate neutron spectrometry is required for beam characterization, qualityassurance and dosimetric assessment in accelerator-based Boron Neutron CaptureTherapy (BNCT). Established methods, such as activation foils and Bonnersphere systems, provide reliable fluence and spectrometric information but requiresequential irradiations, post-processing and off-line analysis. Compact detectorsystems able to provide spectrometric information with a simpler measurementworkflow are therefore of practical interest.This work presents the Monte Carlo design and proof-of-concept experimentaltest of a compact neutron spectrometer based on fiber-coupled lithium-glassscintillators embedded in a cylindrical polyethylene moderator with an active lengthof 15cm. The detector response was modelled with FLUKA, including neutrontransport, the 6Li(n,α)3H reaction, scintillation-light production and optical-fiberacceptance. Response matrices were calculated for different moderator radii, andthe 100mm radius configuration was selected for testing at the Nagoya Universityaccelerator-based BNCT facility.The single-detector response was linear over the investigated acceleratoroperating-current range, from 0.2mA to 2mA, and the nozzle/no-nozzle measurements showed sensitivity to beam-line changes. In the nozzle configuration, the unfolded spectrum reproduced the Monte Carlo reference in the epithermal region. After gold-foil calibration, the unfolded total fluence rate was(7.28 ± 0.18) × 10^7 n cm-2 s-1, 5.7% lower than the 1mA reference neutron fluence. This paper shows the first experimental demonstration of an active moderatedspectrometer reconstructing a BNCT neutron spectrum. This spectral-shapeagreement establishes compact active spectrometry as a feasible tool for BNCTbeam characterization, while absolute response calibration remains the mainlimitation.
- Open Access
- 18 August 2025
- Published by Elsevier in Physica Medica
- Vol. 137, 105070
Development and simulation of a SPECT real time dose monitoring system for BNCT: response at the LENA reactor
- 18 August 2025
- Published by Elsevier in Physica Medica
- Vol. 137, 105070
Open AccessDevelopment and simulation of a SPECT real time dose monitoring system for BNCT: response at the LENA reactor
- 13 July 2023
- Published by PAGEPress Publications in Istituto Lombardo - Accademia di Scienze e Lettere - Rendiconti di Scienze
Microdosimetry
The interest in the application of microdosimetry for assessing the radiation quality of hadrontherapy fields has grown in the last two decades. The reference detector for microdosimetry is the tissue-equivalent proportional counter (TEPC). Novel types of microdosimeters have been developed by the Nuclear Measurement Laboratory of the Politecnico di Milano in collaboration with the INFN National Legnaro Laboratories. This work describes the main features of an avalanche confinement TEPC, capable of simulating sites down to 25 nm and a silicon telescope detector. The main dosimetric and microdosimetric quantities are also given and discussed in the Introduction for the sake of clarity.
- 13 July 2023
- Published by PAGEPress Publications in Istituto Lombardo - Accademia di Scienze e Lettere - Rendiconti di Scienze
Microdosimetry
The interest in the application of microdosimetry for assessing the radiation quality of hadrontherapy fields has grown in the last two decades. The reference detector for microdosimetry is the tissue-equivalent proportional counter (TEPC). Novel types of microdosimeters have been developed by the Nuclear Measurement Laboratory of the Politecnico di Milano in collaboration with the INFN National Legnaro Laboratories. This work describes the main features of an avalanche confinement TEPC, capable of simulating sites down to 25 nm and a silicon telescope detector. The main dosimetric and microdosimetric quantities are also given and discussed in the Introduction for the sake of clarity.
- Open Access
- 10 March 2023
- Published by Elsevier in Physica Medica
- Vol. 107, 102554
Prompt-gamma fall-off estimation with C-ion irradiation at clinical energies, using a knife-edge slit camera: A Monte Carlo study
- 10 March 2023
- Published by Elsevier in Physica Medica
- Vol. 107, 102554
Open AccessPrompt-gamma fall-off estimation with C-ion irradiation at clinical energies, using a knife-edge slit camera: A Monte Carlo study
- 3 June 2022
- Published by Elsevier in Radiation Measurements
- Vol. 156
Detectors for measurement of microdosimetric quantities
- 3 June 2022
- Published by Elsevier in Radiation Measurements
- Vol. 156
Detectors for measurement of microdosimetric quantities
- Open Access
- 4 May 2022
- Published by Elsevier in Radiation Measurements
- Vol. 154
Development of the ACSpect neutron spectrometer: Technological advance and response against an accelerator-based neutron beam
- 4 May 2022
- Published by Elsevier in Radiation Measurements
- Vol. 154
Open AccessDevelopment of the ACSpect neutron spectrometer: Technological advance and response against an accelerator-based neutron beam
- 1 September 2021
- Published by Elsevier in Physica Medica
- Vol. 89, 226-231
Experimental investigation at CATANA facility of n-10B and p-11B reactions for the enhancement of proton therapy
- 1 September 2021
- Published by Elsevier in Physica Medica
- Vol. 89, 226-231
Experimental investigation at CATANA facility of n-10B and p-11B reactions for the enhancement of proton therapy
- 1 August 2020
- Published by Elsevier in Radiation Measurements
- Vol. 136
Therapeutic proton beams: LET, RBE and microdosimetric spectra with gas and silicon detectors
- 1 August 2020
- Published by Elsevier in Radiation Measurements
- Vol. 136
Therapeutic proton beams: LET, RBE and microdosimetric spectra with gas and silicon detectors
- 1 April 2019
- Published by Elsevier in Radiation Measurements
- Vol. 123, 26-33
Nano-microdosimetric investigation at the therapeutic proton irradiation line of CATANA
- 1 April 2019
- Published by Elsevier in Radiation Measurements
- Vol. 123, 26-33
Nano-microdosimetric investigation at the therapeutic proton irradiation line of CATANA