Jonathan C. Pitts Crick
Research Subjects
Jonathan C. Pitts Crick has a total of 56 co-authors. Here are the top co-authors by number of shared publications:
Edgar Sowton
7 shared publicationsA D Timmis
Department of Cardiology, Guy's Hospital, London
4 shared publicationsE. Sowton
Department of Cardiology, Guy's Hospital, London, England
4 shared publicationsAdam D. Timmis
3 shared publicationsBrian Griffin
3 shared publicationsD A Chamberlain
3 shared publications
Latest Publications
- Open Access
- 1 October 2014
- Published by Oxford University Press (OUP) in EP Europace
- Vol. 16 (suppl 3)
8 * Submammary device implantation: long-term results
- 1 October 2014
- Published by Oxford University Press (OUP) in EP Europace
- Vol. 16 (suppl 3)
Open Access8 * Submammary device implantation: long-term results
- Open Access
- 5 December 2012
- Published by Springer Nature
Atrial pacing in paroxymal Atrial Fibrillation (AF) (ELA)
- 5 December 2012
- Published by Springer Nature
Open AccessAtrial pacing in paroxymal Atrial Fibrillation (AF) (ELA)
- Open Access
160 High dose octreotide; a novel therapy for the treatment of drug refractory postural orthostatic tachycardia syndrome in patients with joint hypermobility syndrome
Introduction Postural orthostatic tachycardia syndrome (POTS) is defined as symptomatic orthostatic intolerance with an increase in heart rate of 30 beats per minute within 10 min of head up tilt (HUT). This dysautonomia causes wide-ranging symptoms including palpitations, presyncope, chronic fatigue, headache and cognitive difficulties. When POTS occurs in patients with pre-existing Joint Hypermobility Syndrome (JHS), symptoms begin approximately a decade earlier than non-JHS patients with a preponderance of neurological features, secondary to cerebral hypoperfusion. Vascular laxity with splanchnic venous pooling has been implicated as a causative factor thus measures to expand plasma volume (thereby increasing mean arterial pressure and restoring cerebral perfusion) form the mainstay of therapy. Symptomatic improvements have been previously reported in POTS patients with the somatostatin analogue Octreotide, a powerful splanchnic vasoconstrictor. We report the first UK series of JHS patients with drug refractory POTS treated with high-dose octreotide. Methods Six patients (female, aged 21–52) were referred to our institution. All had known JHS (4 requiring a wheelchair), neurological symptoms (headache and cognitive impairment) and diagnostic tilt-table testing with a mean increase in heart rate of 64 beats/min (range 47–73) with head-up tilt (HUT). All patients had remained symptomatic despite pre-treatment with a mean of 5 POTS medications (range 5–7) including fludrocortisone, midodrine, propranolol, ivabradine, selective serotonin reuptake inhibitors, gabapentin and erythropoietin. Octreotide was commenced using a short-acting preparation given 3 times daily (dosage 50–250 μg according to body mass) in conjunction with a long-acting (monthly), intramuscular injection (dosage 10–30 mg). The short-acting preparation was weaned following the second monthly injection. Results During follow-up of 3 months (range 1–8), 3 (50%) patients reported a complete resolution of all postural and neurological symptoms which corresponded with a normalised response to HUT. The remaining patients reported a dramatic improvement but ongoing postural symptoms. No patients developed supine hypertension. Side effects including mild abdominal discomfort and transient diarrhoea were reported in 3 (50%) patients. Conclusion Octreotide is increasingly recognised as an effective therapy in POTS patients. Both short-acting, subcutaneous (0.9 μg/Kg) and long-acting, intramuscular (10–20 mg) preparations have previously been reported. We conclude that higher dosages of both preparations when administered together are effective and well tolerated in JHS patients with drug refractory POTS.
Open Access160 High dose octreotide; a novel therapy for the treatment of drug refractory postural orthostatic tachycardia syndrome in patients with joint hypermobility syndrome
Introduction Postural orthostatic tachycardia syndrome (POTS) is defined as symptomatic orthostatic intolerance with an increase in heart rate of 30 beats per minute within 10 min of head up tilt (HUT). This dysautonomia causes wide-ranging symptoms including palpitations, presyncope, chronic fatigue, headache and cognitive difficulties. When POTS occurs in patients with pre-existing Joint Hypermobility Syndrome (JHS), symptoms begin approximately a decade earlier than non-JHS patients with a preponderance of neurological features, secondary to cerebral hypoperfusion. Vascular laxity with splanchnic venous pooling has been implicated as a causative factor thus measures to expand plasma volume (thereby increasing mean arterial pressure and restoring cerebral perfusion) form the mainstay of therapy. Symptomatic improvements have been previously reported in POTS patients with the somatostatin analogue Octreotide, a powerful splanchnic vasoconstrictor. We report the first UK series of JHS patients with drug refractory POTS treated with high-dose octreotide. Methods Six patients (female, aged 21–52) were referred to our institution. All had known JHS (4 requiring a wheelchair), neurological symptoms (headache and cognitive impairment) and diagnostic tilt-table testing with a mean increase in heart rate of 64 beats/min (range 47–73) with head-up tilt (HUT). All patients had remained symptomatic despite pre-treatment with a mean of 5 POTS medications (range 5–7) including fludrocortisone, midodrine, propranolol, ivabradine, selective serotonin reuptake inhibitors, gabapentin and erythropoietin. Octreotide was commenced using a short-acting preparation given 3 times daily (dosage 50–250 μg according to body mass) in conjunction with a long-acting (monthly), intramuscular injection (dosage 10–30 mg). The short-acting preparation was weaned following the second monthly injection. Results During follow-up of 3 months (range 1–8), 3 (50%) patients reported a complete resolution of all postural and neurological symptoms which corresponded with a normalised response to HUT. The remaining patients reported a dramatic improvement but ongoing postural symptoms. No patients developed supine hypertension. Side effects including mild abdominal discomfort and transient diarrhoea were reported in 3 (50%) patients. Conclusion Octreotide is increasingly recognised as an effective therapy in POTS patients. Both short-acting, subcutaneous (0.9 μg/Kg) and long-acting, intramuscular (10–20 mg) preparations have previously been reported. We conclude that higher dosages of both preparations when administered together are effective and well tolerated in JHS patients with drug refractory POTS.
- Open Access
- 7 April 2008
- Published by Oxford University Press (OUP) in EP Europace
- Vol. 10 (6) , 683-686
Impact of cryoablation catheter size on success rates in the treatment of atrioventricular nodal re-entry tachycardia in 160 patients with long-term follow-up
To determine the efficacy and safety of cryoablation for the treatment of atrioventricular nodal re-entry tachycardia (AVNRT). We analysed the procedural characteristics, acute success, and recurrence rates of 160 consecutive patients treated with cryoablation for the AVNRT and followed up for 18 months. Mean procedural time was 119.1 ± 3.7 min, with an average of 4.6 ± 0.2 Cryo lesions and an acute procedural success rate of 93%. Recurrence rates were 19 (11.9%) cases and were significantly higher in the 4 mm cryocatheter-treated group (12/59, 16.9%), compared with the 6 mm cryocatheter-treated group (9/101, 6.9%, P = 0.01). Recurrence rates were greater where slow pathway block was not achieved 8/12 (66.7%), compared with complete slow pathway block 11/129 (8.5%, P < 0.0001). Recurrence was significantly more likely if atrial echo beats were still present after cryoablation, 12/130 (9.2%) patients with no recurrence vs. 7/19 (36.8%) patients with recurrence ( P < 0.0001). Cryoablation is a safe and efficacious treatment for AVNRT. Complete slow pathway block is associated with long-term success, together with the use of the larger 6 mm cryocatheter. There is always a risk of heart block with radiofrequency ablation, although this experience confirms previous findings that the risk with Cryo is zero.
- 7 April 2008
- Published by Oxford University Press (OUP) in EP Europace
- Vol. 10 (6) , 683-686
Open AccessImpact of cryoablation catheter size on success rates in the treatment of atrioventricular nodal re-entry tachycardia in 160 patients with long-term follow-up
To determine the efficacy and safety of cryoablation for the treatment of atrioventricular nodal re-entry tachycardia (AVNRT). We analysed the procedural characteristics, acute success, and recurrence rates of 160 consecutive patients treated with cryoablation for the AVNRT and followed up for 18 months. Mean procedural time was 119.1 ± 3.7 min, with an average of 4.6 ± 0.2 Cryo lesions and an acute procedural success rate of 93%. Recurrence rates were 19 (11.9%) cases and were significantly higher in the 4 mm cryocatheter-treated group (12/59, 16.9%), compared with the 6 mm cryocatheter-treated group (9/101, 6.9%, P = 0.01). Recurrence rates were greater where slow pathway block was not achieved 8/12 (66.7%), compared with complete slow pathway block 11/129 (8.5%, P < 0.0001). Recurrence was significantly more likely if atrial echo beats were still present after cryoablation, 12/130 (9.2%) patients with no recurrence vs. 7/19 (36.8%) patients with recurrence ( P < 0.0001). Cryoablation is a safe and efficacious treatment for AVNRT. Complete slow pathway block is associated with long-term success, together with the use of the larger 6 mm cryocatheter. There is always a risk of heart block with radiofrequency ablation, although this experience confirms previous findings that the risk with Cryo is zero.
- 1 November 1996
- Published by Wiley in Pacing and Clinical Electrophysiology
- Vol. 19 (11) , 1772-1776
Evolution of Atrial Signals from a Single Lead VDD Pacemaker
The atrial sensing capabilities of a new single pass lead VDD pacing system (Pacesetter AddVent) were assessed in a prospective multicenter study of 101 implants during the period July 1994 through March 1996. The pacing lead (Pacesetter AV Plus) has a unique quadripolar 4‐in‐line connector and uses a pair of ring electrodes with an interelectrode spacing of 12 mm for atrial sensing. The mean age of the patients (51 men) was 73 years (range 19–91). Seventy‐five patients had complete heart block; the others had 2:1 AV block. Wide variations were found in signal amplitude: mean P wave amplitude, measured over four cycles in the supine position, was 2.4 ± 1.9 mV at implant, dropping to 1.9 ± 1.7 mV predischarge, and remaining constant at follow‐up but with a narrower range. Holter monitoring was undertaken in 24 patients, with a total of 550 monitored hours. Mean AV synchrony was 98.2%± 4.6% (excluding premature ventricular contractions), with 20 patients (83%) showing > 99% AV synchrony, with atrial sensing at 0.1 mV where needed. No oversensing was observed in any patient. There was a low incidence of atrial fibrillation (2%) and sinus bradycardia (0%). The findings show that the range of atrial signals, although wide initially, converges over the first year and remains adequate for reliable AV synchronous pacing.
- 1 November 1996
- Published by Wiley in Pacing and Clinical Electrophysiology
- Vol. 19 (11) , 1772-1776
Evolution of Atrial Signals from a Single Lead VDD Pacemaker
The atrial sensing capabilities of a new single pass lead VDD pacing system (Pacesetter AddVent) were assessed in a prospective multicenter study of 101 implants during the period July 1994 through March 1996. The pacing lead (Pacesetter AV Plus) has a unique quadripolar 4‐in‐line connector and uses a pair of ring electrodes with an interelectrode spacing of 12 mm for atrial sensing. The mean age of the patients (51 men) was 73 years (range 19–91). Seventy‐five patients had complete heart block; the others had 2:1 AV block. Wide variations were found in signal amplitude: mean P wave amplitude, measured over four cycles in the supine position, was 2.4 ± 1.9 mV at implant, dropping to 1.9 ± 1.7 mV predischarge, and remaining constant at follow‐up but with a narrower range. Holter monitoring was undertaken in 24 patients, with a total of 550 monitored hours. Mean AV synchrony was 98.2%± 4.6% (excluding premature ventricular contractions), with 20 patients (83%) showing > 99% AV synchrony, with atrial sensing at 0.1 mV where needed. No oversensing was observed in any patient. There was a low incidence of atrial fibrillation (2%) and sinus bradycardia (0%). The findings show that the range of atrial signals, although wide initially, converges over the first year and remains adequate for reliable AV synchronous pacing.
- 1 January 1996
- Published by Springer Nature
- p. 119-125
Single lead atrial synchronised ventricular (VDD) pacing
- 1 January 1996
- Published by Springer Nature
- p. 119-125
Single lead atrial synchronised ventricular (VDD) pacing
- 1 November 1995
- Published by Wiley in Pacing and Clinical Electrophysiology
- Vol. 18 (11) , 2103-2105
Successful Long‐Term Ventricular Pacing Via the Coronary Sinus After the Fontan Operation
A man with double inlet left ventricle and severe subpulmonary stenosis underwent a Fontan operation at the age of 29 years. Eight years later he developed atrial flutter with complete heart block. To avoid a further thoracotomy, a unipolar carbon tipped electrode was placed into the posterior cardiac vein via the coronary sinus. More than 8 years after implantation of the original lead, and after two generator changes, telemetric thresholds remain between 1.8–2.1 volts. Percutaneous transvenous ventricular pacing via the coronary sinus can produce an excellent long‐term result and should be the initial approach of choice after a Fontan‐type operation.
- 1 November 1995
- Published by Wiley in Pacing and Clinical Electrophysiology
- Vol. 18 (11) , 2103-2105
Successful Long‐Term Ventricular Pacing Via the Coronary Sinus After the Fontan Operation
A man with double inlet left ventricle and severe subpulmonary stenosis underwent a Fontan operation at the age of 29 years. Eight years later he developed atrial flutter with complete heart block. To avoid a further thoracotomy, a unipolar carbon tipped electrode was placed into the posterior cardiac vein via the coronary sinus. More than 8 years after implantation of the original lead, and after two generator changes, telemetric thresholds remain between 1.8–2.1 volts. Percutaneous transvenous ventricular pacing via the coronary sinus can produce an excellent long‐term result and should be the initial approach of choice after a Fontan‐type operation.
- 1 November 1991
- Published by Wiley in Pacing and Clinical Electrophysiology
- Vol. 14 (11) , 1742-1744
European Multicenter Prospective Follow‐Up Study of 1,002 Implants of a Single Lead VDD Pacing System
- 1 November 1991
- Published by Wiley in Pacing and Clinical Electrophysiology
- Vol. 14 (11) , 1742-1744
European Multicenter Prospective Follow‐Up Study of 1,002 Implants of a Single Lead VDD Pacing System
- 1 June 1991
- Published by Springer Nature in Heart and Vessels
- Vol. 6 (2) , 102-106
Hemostatic studies in patients with infective endocarditis: a report on nine consecutive cases with evidence of coagulopathy
- 1 June 1991
- Published by Springer Nature in Heart and Vessels
- Vol. 6 (2) , 102-106
Hemostatic studies in patients with infective endocarditis: a report on nine consecutive cases with evidence of coagulopathy
- 1 April 1989
- Published by Elsevier in International Journal of Cardiology
- Vol. 23 (1) , 139-140
Letter to the editor
- 1 April 1989
- Published by Elsevier in International Journal of Cardiology
- Vol. 23 (1) , 139-140
Letter to the editor