Pyungwoo Yeon
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Pyungwoo Yeon has a total of 31 co-authors. Here are the top co-authors by number of shared publications:
- Maysam Ghovanloo
Bionic Sciences Inc., Atlanta, GA, USA
4 shared publications Amin Arbabian
Department of Electrical Engineering, Stanford University, Stanford, CA, USA
3 shared publications- Min-Gu Kim
Department of Medical Engineering, College of Medicine, Yonsei University, Seoul, Republic of Korea
2 shared publications - Oliver Brand
School of Electrical and Computer Engineering, Georgia Institute of Technology, Atlanta, GA, USA
2 shared publications - Choongsoon Kim
School of Electrical and Computer Engineering, Institute for Electronics and Nanotechnology, Georgia Institute of Technology, Atlanta, GA, USA
1 shared publication - Christian F. Chamberlayne
Department of Chemistry, Stanford University, Stanford, CA, USA
1 shared publication
Latest Publications
- 22 July 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Circuits and Systems
- Vol. 20 (1) , 41-56
A 40.68-MHz Fully-Integrated Voltage/Current-Mode Dual-Output PMU for Wireless Neural Implants
This paper presents a fully-integrated single-input dual-output power management unit operating both in voltage/current modes for powering mm-scale wireless neural implants. The chip operates in voltage mode most of the time, using an active full-wave rectifier to regulate a low-voltage, high-load output with high power efficiency and low output ripple ($<$32 $\mathrm{mV}_{\mathrm{pp}}$). It switches to current mode rectification when generating a high-voltage, low-load output. This dual-mode operation allows for flexible power distribution and configurable voltage ratios between the two outputs. The selected 40.68 MHz operating frequency reduces the required capacitances for input impedance matching and output filtering, enabling on-chip integration; the only external component is the receiver coil. A novel resonance breakup switch compatible with full-wave rectification ensures a smooth cold start-up of the chip without any external voltage supply. The chip was fabricated using 40-nm CMOS technology with an active area of 1.18 $\mathrm{mm^{2}}$ and was tested in a wireless power link. Measurement results demonstrate that the chip can simultaneously regulate two outputs, $V_{LV}$ = 1 V and $V_{HV}$ = 2 V, with a tested maximum output power of 10 mW and 32.6 µW on $V_{LV}$ and $V_{HV}$, respectively. At the optimal output power condition ($P_{LV}$ = 4.4$\sim$6.7 mW), the system achieves a peak power conversion efficiency of 85.87% and a peak end-to-end efficiency of 17.32% when regulating $V_{LV}$. The end-to-end efficiency drops by only 2.38% when regulating both outputs with $R_{LV}$ = 225 $\Omega$ and $R_{HV}$ = 400 k$\Omega$.
- 22 July 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Circuits and Systems
- Vol. 20 (1) , 41-56
A 40.68-MHz Fully-Integrated Voltage/Current-Mode Dual-Output PMU for Wireless Neural Implants
This paper presents a fully-integrated single-input dual-output power management unit operating both in voltage/current modes for powering mm-scale wireless neural implants. The chip operates in voltage mode most of the time, using an active full-wave rectifier to regulate a low-voltage, high-load output with high power efficiency and low output ripple ($<$32 $\mathrm{mV}_{\mathrm{pp}}$). It switches to current mode rectification when generating a high-voltage, low-load output. This dual-mode operation allows for flexible power distribution and configurable voltage ratios between the two outputs. The selected 40.68 MHz operating frequency reduces the required capacitances for input impedance matching and output filtering, enabling on-chip integration; the only external component is the receiver coil. A novel resonance breakup switch compatible with full-wave rectification ensures a smooth cold start-up of the chip without any external voltage supply. The chip was fabricated using 40-nm CMOS technology with an active area of 1.18 $\mathrm{mm^{2}}$ and was tested in a wireless power link. Measurement results demonstrate that the chip can simultaneously regulate two outputs, $V_{LV}$ = 1 V and $V_{HV}$ = 2 V, with a tested maximum output power of 10 mW and 32.6 µW on $V_{LV}$ and $V_{HV}$, respectively. At the optimal output power condition ($P_{LV}$ = 4.4$\sim$6.7 mW), the system achieves a peak power conversion efficiency of 85.87% and a peak end-to-end efficiency of 17.32% when regulating $V_{LV}$. The end-to-end efficiency drops by only 2.38% when regulating both outputs with $R_{LV}$ = 225 $\Omega$ and $R_{HV}$ = 400 k$\Omega$.
- 27 November 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Circuits and Systems
- Vol. 19 (4) , 777-790
A Wireless Implantable Closed-Loop Electrochemical Drug Delivery System
Wireless implantable drug delivery systems (DDSs) enable targeted, on-demand drug release to maximize therapeutic efficacy. Ultrasound has been proposed to wirelessly power and control millimeter-sized deeply implantable DDSs, but initial demonstrations encountered challenges in power transfer and release control reliability in dynamic in vivo environments. In this work, we present a closed-loop implantable DDS using ultrasound wireless power and communication in conjunction with an electrochemical drug release mechanism. The system consists of piezoelectric transducers for wireless power and data transmission, a drug delivery module containing drug-loaded electroresponsive nanoparticles, and a custom CMOS integrated circuit for closed-loop drug release using a programmable potentiostat capable of providing potentials up to ±1.5 V and sensing current up to ±100 μA. The chip also improves power transfer robustness by enabling ultrasound power combining and rectifier voltage feedback which can be used to adapt the power transmitter and minimize misalignment. Closed-loop release control is tested in vitro using the wirelessly powered DDS at 8 cm depth by adjusting the potentiostat stimulus voltage based on feedback of redox current into fluorescein-loaded nanoparticles, resulting in consistent 2 μg release across different fluorescein loading concentrations and a 39% reduction in release amount variation. These results demonstrate the effectiveness of closed-loop release control in enabling precise and reliable drug delivery.
- 27 November 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Circuits and Systems
- Vol. 19 (4) , 777-790
A Wireless Implantable Closed-Loop Electrochemical Drug Delivery System
Wireless implantable drug delivery systems (DDSs) enable targeted, on-demand drug release to maximize therapeutic efficacy. Ultrasound has been proposed to wirelessly power and control millimeter-sized deeply implantable DDSs, but initial demonstrations encountered challenges in power transfer and release control reliability in dynamic in vivo environments. In this work, we present a closed-loop implantable DDS using ultrasound wireless power and communication in conjunction with an electrochemical drug release mechanism. The system consists of piezoelectric transducers for wireless power and data transmission, a drug delivery module containing drug-loaded electroresponsive nanoparticles, and a custom CMOS integrated circuit for closed-loop drug release using a programmable potentiostat capable of providing potentials up to ±1.5 V and sensing current up to ±100 μA. The chip also improves power transfer robustness by enabling ultrasound power combining and rectifier voltage feedback which can be used to adapt the power transmitter and minimize misalignment. Closed-loop release control is tested in vitro using the wirelessly powered DDS at 8 cm depth by adjusting the potentiostat stimulus voltage based on feedback of redox current into fluorescein-loaded nanoparticles, resulting in consistent 2 μg release across different fluorescein loading concentrations and a 39% reduction in release amount variation. These results demonstrate the effectiveness of closed-loop release control in enabling precise and reliable drug delivery.
- Open Access
- 13 May 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Solid-State Circuits
- Vol. 57 (11) , 3429-3441
An RF-Ultrasound Relay for Adaptive Wireless Powering Across Tissue Interfaces
Single modality wireless power transfer has limited depth for mm-sized implants across air/tissue or skull/tissue interfaces because they either suffer from a high loss in tissue (RF, optical) or high reflection at the medium interface [ultrasound (US)]. This article proposes an RF-US relay chip at the media interface avoiding the reflection at the boundary and enables efficient wireless powering to mm-sized deep implants across multiple media. The relay chip rectifies the incoming RF power through an 85.5% efficient RF inductive link (across air) using a multi-output regulating rectifier (MORR) with 81% power conversion efficiency (PCE) at 186 mW load and transmits using adiabatic power amplifiers (PAs) to the implant in order to minimize cascaded power loss. To adapt US focus to implant movement or placement, beamforming was implemented using six channels of US PAs with two-bit phase control (0°, 90°, 180°, and 270°) and three different amplitudes (6–29, 4.5, and 1.8 V) from the MORR. The adiabatic PA contributes a 30%–40% increase in efficiency over class-D and beamforming increases the efficiency by 251% at 2.5 cm over fixed focusing. The proof-of-concept powering system for a retinal implant, from an external PA on a pair of glasses to a hydrophone with 1.2 cm (air) + 2.9 cm (agar eyeball phantom in mineral oil) separation distance, had a power delivered to the load (PDL) of 946 $\mu \text{W}$ . The 2.3 mm × 2 mm relay chip was fabricated in a 180 nm high-voltage (HV) BCD process.
- 13 May 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Solid-State Circuits
- Vol. 57 (11) , 3429-3441
Open AccessAn RF-Ultrasound Relay for Adaptive Wireless Powering Across Tissue Interfaces
Single modality wireless power transfer has limited depth for mm-sized implants across air/tissue or skull/tissue interfaces because they either suffer from a high loss in tissue (RF, optical) or high reflection at the medium interface [ultrasound (US)]. This article proposes an RF-US relay chip at the media interface avoiding the reflection at the boundary and enables efficient wireless powering to mm-sized deep implants across multiple media. The relay chip rectifies the incoming RF power through an 85.5% efficient RF inductive link (across air) using a multi-output regulating rectifier (MORR) with 81% power conversion efficiency (PCE) at 186 mW load and transmits using adiabatic power amplifiers (PAs) to the implant in order to minimize cascaded power loss. To adapt US focus to implant movement or placement, beamforming was implemented using six channels of US PAs with two-bit phase control (0°, 90°, 180°, and 270°) and three different amplitudes (6–29, 4.5, and 1.8 V) from the MORR. The adiabatic PA contributes a 30%–40% increase in efficiency over class-D and beamforming increases the efficiency by 251% at 2.5 cm over fixed focusing. The proof-of-concept powering system for a retinal implant, from an external PA on a pair of glasses to a hydrophone with 1.2 cm (air) + 2.9 cm (agar eyeball phantom in mineral oil) separation distance, had a power delivered to the load (PDL) of 946 $\mu \text{W}$ . The 2.3 mm × 2 mm relay chip was fabricated in a 180 nm high-voltage (HV) BCD process.
- 23 March 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 21 (12) , 13837-13848
Microfabrication, Coil Characterization, and Hermetic Packaging of Millimeter-Sized Free-Floating Neural Probes
This paper presents a new micromachining (MEMS) fabrication, microassembly, and hermetic packaging process for free-floating neural probes (<; 1 mm 3 ). It offers an intuitive probe assembly and a robust design against mechanical and material failures. A key component of the pushpin neural probe is a 1.3×1.3 mm 2 bath-tub shaped micromachined silicon die, which serves as a substrate that supports all passive components in non-plated through-silicon cavities (TSCs) plus four nothing 81 μm tungsten electrodes embedded in \varnothing 100 μm non-plated through-silicon holes (TSHs), and a 6-turns bonding wire wound coil (WWC) around the die. The current passive probe prototype houses a 1.2×1.2 mm 2 mock-up integrated circuit (IC) in a bath-tub cavity created in the passive micromachined die. The probe is hermetically sealed with a 5 μm thick parylene-C film except for the tip of the electrodes, and covered with an additional layer of polydimethylsiloxane (PDMS) for physical protection and reduction of mechanical mismatch with brain tissue. WWCs around the micromachined silicon die are used for power or data transmission and were electrically characterized by theoretical analysis, simulation, and measurements in air and lossy tissue medium. This way, the impact of the inner silicon substrate, packaging, and surrounding tissue on the inductance ( L s ) and Q-factor ( Q s ) of the WWC are studied and related to the resonance frequency ( f 0 ) and power transmission efficiency (PTE). The lifetime of the current probe prototypes is estimated by using a customized wireless hermetic failure monitoring tool under an accelerated condition (1 atm, 100% RH, and 80 °C).
- 23 March 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 21 (12) , 13837-13848
Microfabrication, Coil Characterization, and Hermetic Packaging of Millimeter-Sized Free-Floating Neural Probes
This paper presents a new micromachining (MEMS) fabrication, microassembly, and hermetic packaging process for free-floating neural probes (<; 1 mm 3 ). It offers an intuitive probe assembly and a robust design against mechanical and material failures. A key component of the pushpin neural probe is a 1.3×1.3 mm 2 bath-tub shaped micromachined silicon die, which serves as a substrate that supports all passive components in non-plated through-silicon cavities (TSCs) plus four nothing 81 μm tungsten electrodes embedded in \varnothing 100 μm non-plated through-silicon holes (TSHs), and a 6-turns bonding wire wound coil (WWC) around the die. The current passive probe prototype houses a 1.2×1.2 mm 2 mock-up integrated circuit (IC) in a bath-tub cavity created in the passive micromachined die. The probe is hermetically sealed with a 5 μm thick parylene-C film except for the tip of the electrodes, and covered with an additional layer of polydimethylsiloxane (PDMS) for physical protection and reduction of mechanical mismatch with brain tissue. WWCs around the micromachined silicon die are used for power or data transmission and were electrically characterized by theoretical analysis, simulation, and measurements in air and lossy tissue medium. This way, the impact of the inner silicon substrate, packaging, and surrounding tissue on the inductance ( L s ) and Q-factor ( Q s ) of the WWC are studied and related to the resonance frequency ( f 0 ) and power transmission efficiency (PTE). The lifetime of the current probe prototypes is estimated by using a customized wireless hermetic failure monitoring tool under an accelerated condition (1 atm, 100% RH, and 80 °C).
- 1 November 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 245-246
A 200-MHz Wide Input Range CMOS Passive Rectifier with Active Bias Tunning
A high efficiency wireless power transfer system that operates in the very high frequency (VHF) band is desirable for miniaturized implantable medical devices (IMD), but also challenging. This work presents an integrated VHF passive rectifier with closed-loop active bias tuning (ABT). Power PMOS and NMOS transistors are separately cross-connected, such that the DC bias voltages of the NMOS gates can be dynamically adjusted. We employed a search scheme for V OUT -peak to obtain the optimum bias voltage over a wide input range. A prototype fabricated in 65nm std-CMOS process measured a power convention efficiency of 64% at 200MHz with 3kΩ loading.
- 1 November 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 245-246
A 200-MHz Wide Input Range CMOS Passive Rectifier with Active Bias Tunning
A high efficiency wireless power transfer system that operates in the very high frequency (VHF) band is desirable for miniaturized implantable medical devices (IMD), but also challenging. This work presents an integrated VHF passive rectifier with closed-loop active bias tuning (ABT). Power PMOS and NMOS transistors are separately cross-connected, such that the DC bias voltages of the NMOS gates can be dynamically adjusted. We employed a search scheme for V OUT -peak to obtain the optimum bias voltage over a wide input range. A prototype fabricated in 65nm std-CMOS process measured a power convention efficiency of 64% at 200MHz with 3kΩ loading.
- 7 May 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 19 (17) , 7460-7470
Optimal Design of Passive Resonating Wireless Sensors for Wearable and Implantable Devices
Passive resonating wireless sensors consist of a variable capacitive (Cs) sensing element in resonance with a coil (Ls) that is inductively coupled with a proximal readout circuit. They have been utilized in a number of medical and contactless industrial applications for their simple, small, battery-less, and wireless capabilities. An external readout coil (Lr) detects changes in the impedance phase spectrum, resulting from changes in the parameter of interest (ΔP), such as pressure, humidity, or permittivity. A method of optimization for this class of sensors is presented based on a new figure-of-merit (FoM) to help designers find optimal geometries for both the sensing and inductive link components of the resonating sensor, leading to maximum signalto-noise ratio (SNR) and sensitivity at a desired reading range. To verify the proposed FoM and optimization algorithm, we fabricated an all-soft resonating wireless sensor prototype for chemical detection with optimal geometry. The phase-dip (Δφdip) of the sensor at 5 mm interrogation distance is 43°, a 1380% improvement after optimization, at 313.5 MHz operating frequency. The maximum sensitivity,δ(Δf0/f0)/δ(ΔP), is 9200 ppm, a 24(MeOH) is applied on the interdigitated capacitive sensor. The design methodology was also applied to an intraocular pressure (IOP) sensor and an implantable humidity sensor from literature, and led to 661simulations, respectively % and 41% improvement in the proposed FoM in simulations, respectively.
- 7 May 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 19 (17) , 7460-7470
Optimal Design of Passive Resonating Wireless Sensors for Wearable and Implantable Devices
Passive resonating wireless sensors consist of a variable capacitive (Cs) sensing element in resonance with a coil (Ls) that is inductively coupled with a proximal readout circuit. They have been utilized in a number of medical and contactless industrial applications for their simple, small, battery-less, and wireless capabilities. An external readout coil (Lr) detects changes in the impedance phase spectrum, resulting from changes in the parameter of interest (ΔP), such as pressure, humidity, or permittivity. A method of optimization for this class of sensors is presented based on a new figure-of-merit (FoM) to help designers find optimal geometries for both the sensing and inductive link components of the resonating sensor, leading to maximum signalto-noise ratio (SNR) and sensitivity at a desired reading range. To verify the proposed FoM and optimization algorithm, we fabricated an all-soft resonating wireless sensor prototype for chemical detection with optimal geometry. The phase-dip (Δφdip) of the sensor at 5 mm interrogation distance is 43°, a 1380% improvement after optimization, at 313.5 MHz operating frequency. The maximum sensitivity,δ(Δf0/f0)/δ(ΔP), is 9200 ppm, a 24(MeOH) is applied on the interdigitated capacitive sensor. The design methodology was also applied to an intraocular pressure (IOP) sensor and an implantable humidity sensor from literature, and led to 661simulations, respectively % and 41% improvement in the proposed FoM in simulations, respectively.
- 14 June 2017
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 17 (13) , 2323-2329
All-soft, battery-free, and wireless chemical sensing platform based on liquid metal for liquid- and gas-phase VOC detection
This paper introduces an all-soft chemical sensing platform based on liquid metal for detection of liquid-phase and gas-phase VOCs and demonstrates battery-free and wireless interrogation between a 3D-integrated, all-soft LC sensor and a soft readout coil.
- 14 June 2017
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 17 (13) , 2323-2329
All-soft, battery-free, and wireless chemical sensing platform based on liquid metal for liquid- and gas-phase VOC detection
This paper introduces an all-soft chemical sensing platform based on liquid metal for detection of liquid-phase and gas-phase VOCs and demonstrates battery-free and wireless interrogation between a 3D-integrated, all-soft LC sensor and a soft readout coil.