THTor Hildebrand

Tor Hildebrand

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Tor Hildebrand has a total of 31 co-authors. Here are the top co-authors by number of shared publications:

  • Andres Laib

    Institute for Biomedical Engineering, University of Zürich and Swiss Federal Institute of Technology (ETH), Zürich, Switzerland

    2 shared publications
  • P. Rüegsegger

    Institute for Biomedical Engineering, University of Zu¨rich and Swiss Federal Institute of Technology (ETH), Moussonstrasse 18, CH‐8044 Zu¨rich, Switzerland

    2 shared publications
  • Peter Rüegsegger

    Institute for Biomedical Engineering, University of Zürich and Swiss Federal Institute of Technology (ETH), Zürich, Switzerland

    2 shared publications
  • Ralph Müller

    Institute for Biomechanics, ETH Zürich, Zürich, Switzerland

    2 shared publications
  • Adrian Kohlbrenner

    Univ. Zuerich and Swiss Federal Institute of Technology (Switzerland)

    1 shared publication
  • Alexander Kichigin

    Friedrich-Alexander-Universität Erlangen-Nürnberg

    1 shared publication

Latest Publications

  • Open Access

    Correlative X-ray and electron tomography for scale-bridging, quantitative analysis of complex, hierarchical particle systems

    by Allison Götz, Fabian Lutter, Dennis Simon Possart, Daniel Augsburger, Usman Arslan, Sabrina Pechmann, Carmen Rubach, Moritz Buwen, Umair Sultan, Alexander Kichigin, et al.


  • Direct Three-Dimensional Morphometric Analysis of Human Cancellous Bone: Microstructural Data from Spine, Femur, Iliac Crest, and Calcaneus

    by Tor Hildebrand, Andres Laib, Ralph Müller, Jan Dequeker, Peter Rüegsegger

    The appearance of cancellous bone architecture is different for various skeletal sites and various disease states. During aging and disease, plates are perforated and connecting rods are dissolved. There is a continuous shift from one structural type to the other. So traditional histomorphometric procedures, which are based on a fixed model type, will lead to questionable results. The introduction of three-dimensional (3D) measuring techniques in bone research makes it possible to capture the actual architecture of cancellous bone without assumptions of the structure type. This requires, however, new methods that make direct use of the 3D information. Within the framework of a BIOMED I project of the European Union, we analyzed a total of 260 human bone biopsies taken from five different skeletal sites (femoral head, vertebral bodies L2 and L4, iliac crest, and calcaneus) from 52 donors. The samples were measured three-dimensionally with a microcomputed tomography scanner and subsequently evaluated with both traditional indirect histomorphometric methods and newly developed direct ones. The results show significant differences between the methods and in their relation to the bone volume fraction. Based on the direct 3D analysis of human bone biopsies, it appears that samples with a lower bone mass are primarily characterized by a smaller plate-to-rod ratio, and to a lesser extent by thinner trabecular elements.


  • Bone structure as revealed by microtomography

    by Tor Hildebrand, Andres Laib, Dieter Ulrich, Adrian Kohlbrenner, Peter Ruegsegger

    The appearance of cancellous bone architecture is different for various skeletal sites and various disease states. In the iliac crest it is more plate-like, whereas in the spine rods dominate. During aging and disease plates are perforated and connecting rods are dissolved. There is a continuous shift from one structural type to the other. So traditional histomorphometric procedures, which are based on a fixed model type, will lead to questionable results. 3D microtomography allows to assess model independent structural parameters so that trabecular thickness, for example, can be determined directly. Not only mean thicknesses are available but also thickness histograms which are helpful to identify pathological states. Other features such as trabecular separation, degree of anisotropy and structural type index can be extracted from the 3D images and allow to characterize cancellous bone and its changes due to aging, disease and treatment. To fully exploit the significance of bone structure on bone strength large scale finite element (FE) analyses are performed. Hence microtomography, performed with a sufficiently fine isotropic spatial resolution, reveals information on the structural features of cancellous bone which were not available so far and which will, hopefully, lead to a better understanding of the pathogenesis of bone diseases and subsequently to improved treatment regimes.


  • A new method for the model‐independent assessment of thickness in three‐dimensional images

    by T. Hildebrand, P. Rüegsegger

    Three‐dimensional (3‐D) structural parameters derived from lower‐dimensional measurements using indirect morphometric methods may be strongly biased if the measured objects deviate from the assumed structure model. With the introduction of 3‐D microscopic measuring techniques it is possible to obtain a complete depiction of complex spatial structures. As a consequence, new 3‐D methods have recently been developed for the estimation of morphometric parameters such as volume, surface area and connectivity by direct processing of the 3‐D images. Structure thickness is an important morphometric parameter which is usually defined for specific structure models only. In this paper we propose a general thickness definition for arbitrary structures allowing us to calculate the mean structure thickness and the thickness distribution of 3‐D objects in a direct way and independently of an assumed structure model. Additionally, an efficient implementation for the practical usage of the method is described using distance transformation. The new method is applied to trabecular bone structures measured with a 3‐D micro‐computed tomography system.


    • 1 January 1997
      • Vol. 40, 97-112

    The quality of trabecular bone evaluated with micro-computed tomography, FEA and mechanical testing.

    by D Ulrich, T Hildebrand, B Van Rietbergen, R Müller, P Rüegsegger

    Most standard methods to predict bone quality are merely based on apparent density measurements. However, apparent density alone does neither explain all variation of the mechanical properties nor does it account for the structural anisotropy of trabecular bone. Thus, apparent density alone might not be sufficient to accurately predict the quality of bone. This study investigates if a new approach based on microstructural computer models can provide additional and relevant information on bone quality. 58 human trabecular bone samples from the femoral head were measured with a 3-D micro-Computed Tomography (micro-CT) system providing a voxel representation of the bone microarchitecture with a resolution of 28 microns. Based on such representations, the orthotropic stiffness matrices and the principal directions were computed for 5 mm cubes with microstructural Finite Element Analysis (FEA). For a subset of six samples the moduli were then validated with tri-axial mechanical compression tests. The results show that on average 15% of the variation of the elastic properties are not explained by bone volume fraction. Differences of elastic properties between samples with the same bone volume fraction range up to 53%. The variation of the degree of anisotropy is unrelated to that of the bone volume fraction. Finally, the direction-dependent stiffness of the trabecular bone differs by a factor of four, indicating that one single (isotropic) modulus as predicted from apparent density measurements might not be adequat. It is concluded that micro-CT-based FEA provides new and additional information about anisotropy and mechanical properties in a direct and non-destructive way, and thus will be important in the future for advanced failure risk prediction. An extension to patient examinations using high-resolution CT or MRI techniques is envisaged.


  • Quantification of Bone Microarchitecture with the Structure Model Index

    by Tor Hildebrand, Peter Rüegsegger

    The deterioration of cancellous bone structure due to aging and disease is characterized by a conversion from plate elements to rod elements. Consequently the terms “rod-like” and “plate-like” are frequently used for a subjective classification of cancellous bone. In this work a new morphometric parameter called Structure Model Index (SMI) is introduced, which makes it possible to quantify the characteristic form of a three-dimensionally described structure in terms of the amount of plates and rod composing the structure. The SMI is calculated by means of three-dimensional image analysis based on a differential analysis of the triangulated bone surface. For an ideal plate and rod structure the SMI value is 0 and 3, respectively, independent of the physical dimensions. For a structure with both plates and rods of equal thickness the value lies between 0 and 3, depending on the volume ratio of rods and plates. The SMI parameter is evaluated by examining bone biopsies from different skeletal sites. The bone samples were measured three-dimensionally with a micro-CT system. Samples with the same volume density but varying trabecular architecture can uniquely be characterized with the SMI. Furthermore the SMI values were found to correspond well with the perceived structure type.