Rajesh Kumar Patnaik
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Rajesh Kumar Patnaik has a total of 15 co-authors. Here are the top co-authors by number of shared publications:
P.K. Dash
3 shared publications- Pradipta Kishore Dash
Multidisciplinary Research Cell, Siksha O Anusandhan Deemed To Be University, Bhubaneswar, India
3 shared publications P. K. Dash
Multidisciplinary Research Cell, SOA University Bhubaneswar, Odisha, India
2 shared publications- J. P. Patra
Department of Electrical Engineering, C. V. Raman Engineering College, Biju Patnaik University of Technology, Bhubaneswar, India
1 shared publication Kaveri Mahapatra
Siksha ‛O’ Anusandhan University; Bhubaneswar India
1 shared publication- Krishnanand Kaippilly Radhakrishnan
Electrical and Computer Engineering Department, National University of Singapore, Singapore
1 shared publication
Latest Publications
- 1 January 2017
- Published by Inderscience Publishers in International Journal of Power and Energy Conversion
- Vol. 8 (4) , 357
Time frequency response-based current differential protection of wide area compensated power system networks
- 1 January 2017
- Published by Inderscience Publishers in International Journal of Power and Energy Conversion
- Vol. 8 (4) , 357
Time frequency response-based current differential protection of wide area compensated power system networks
- Open Access
- 1 May 2016
- Published by Institution of Engineering and Technology (IET) in IET Renewable Power Generation
- Vol. 10 (5) , 598-610
Fast adaptive back‐stepping terminal sliding mode power control for both the rotor‐side as well as grid‐side converter of the doubly fed induction generator‐based wind farms
A fast adaptive back‐stepping terminal sliding mode power control strategy for both the rotor‐side converter and the grid‐side converter of doubly fed induction generator (DFIG) is proposed in this study. The proposed control strategy for the DFIG converters utilises the active and reactive power components derived from the three‐phase voltage and current without the use of phase‐locked loops. For a multimachine power network, incorporating long‐distance transmission lines, inter area oscillation has been a critical issue. Additionally the integration of wind farm to the existing power systems results in the variation of its operating point over time due to unpredictable wind speed variation and consequent fluctuation in the power outputs. Further the proposed control strategy for the DFIG‐based wind farms has been tested on a two‐ area four‐generator system in MATLAB/Editor and MATLAB/Simulink environment subjected to different levels of wind power penetration. The significance and effectiveness of the proposed control strategy to damp out inter area oscillations have been illustrated in the simulation and result section.
- 1 May 2016
- Published by Institution of Engineering and Technology (IET) in IET Renewable Power Generation
- Vol. 10 (5) , 598-610
Open AccessFast adaptive back‐stepping terminal sliding mode power control for both the rotor‐side as well as grid‐side converter of the doubly fed induction generator‐based wind farms
A fast adaptive back‐stepping terminal sliding mode power control strategy for both the rotor‐side converter and the grid‐side converter of doubly fed induction generator (DFIG) is proposed in this study. The proposed control strategy for the DFIG converters utilises the active and reactive power components derived from the three‐phase voltage and current without the use of phase‐locked loops. For a multimachine power network, incorporating long‐distance transmission lines, inter area oscillation has been a critical issue. Additionally the integration of wind farm to the existing power systems results in the variation of its operating point over time due to unpredictable wind speed variation and consequent fluctuation in the power outputs. Further the proposed control strategy for the DFIG‐based wind farms has been tested on a two‐ area four‐generator system in MATLAB/Editor and MATLAB/Simulink environment subjected to different levels of wind power penetration. The significance and effectiveness of the proposed control strategy to damp out inter area oscillations have been illustrated in the simulation and result section.
- 1 October 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 458-464
Damping of interarea oscillations of a wind farm based multimachine power system using an unified Power Flow Controller
An adaptive second order sliding mode control strategy is proposed for of the Series Synchronous Static Compensator (SSSC) of the Unified Power Flow Controller (UPFC) which is installed in a multimachine power network penetrated with a Doubly Fed Induction Generator (DFIG) based wind power. The proposed controller utilizes the instantaneous power components of the SSSC instead of the conventional current or torque components (thus the dynamics of the phase lock loops (PLL) is avoided) and has been made to adapt according to the diverse operating conditions of the network. This feature has made the proposed controller to be more significant (in terms of improvement of the transient stability) as compared to the conventional techniques as both the inter area as well as local oscillations have been improved. The overall power system network has been modeled in MATLAB/Editor environment, and the proposed controller has been investigated for both lower and higher wind penetration conditions and the results obtained are satisfactory.
- 1 October 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 458-464
Damping of interarea oscillations of a wind farm based multimachine power system using an unified Power Flow Controller
An adaptive second order sliding mode control strategy is proposed for of the Series Synchronous Static Compensator (SSSC) of the Unified Power Flow Controller (UPFC) which is installed in a multimachine power network penetrated with a Doubly Fed Induction Generator (DFIG) based wind power. The proposed controller utilizes the instantaneous power components of the SSSC instead of the conventional current or torque components (thus the dynamics of the phase lock loops (PLL) is avoided) and has been made to adapt according to the diverse operating conditions of the network. This feature has made the proposed controller to be more significant (in terms of improvement of the transient stability) as compared to the conventional techniques as both the inter area as well as local oscillations have been improved. The overall power system network has been modeled in MATLAB/Editor environment, and the proposed controller has been investigated for both lower and higher wind penetration conditions and the results obtained are satisfactory.
- 1 October 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 782-788
A new islanding detection and classification technique for the grid connected DFIG wind farms
This paper proposes an efficient islanding detection and classification technique based on the Extreme Learning Machine (ELM) algorithm for the wind farm based distributed generation (DG) connected to a power grid. In regard to design of any classification technique, learning time is a vital aspect to be considered. Thus having inherited with a good capability of generalization and an efficient and speedy leaning capacity, the single hidden layered ELM technique is an attractive technique for developing the detection and classification algorithms. The target feature set comprises of the Total Harmonic Distortion of current (THDi), the Harmonic Amplification Factor of voltage (HAFv) and the Negative Sequence Power (NSP) and is extracted from the efficient Adaline Gauss-Newton algorithm (instead of the conventional Widrow-Hoff delta rule), the input to which are the raw voltage and current at the target DG (where the wind velocity is varied from a minimum to maximum cut-off range). These target feature sets are then utilized by the proposed ELM technique that detects and classifies the islanding events to that of the non-islanding events (switching faults). The proposed DG Model is developed in MATLAB/Simulink environment, and the performance of the proposed ELM technique is compared to some of the conventional techniques in the MATLAB/Editor environment and the results analyzed are satisfactory.
- 1 October 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 782-788
A new islanding detection and classification technique for the grid connected DFIG wind farms
This paper proposes an efficient islanding detection and classification technique based on the Extreme Learning Machine (ELM) algorithm for the wind farm based distributed generation (DG) connected to a power grid. In regard to design of any classification technique, learning time is a vital aspect to be considered. Thus having inherited with a good capability of generalization and an efficient and speedy leaning capacity, the single hidden layered ELM technique is an attractive technique for developing the detection and classification algorithms. The target feature set comprises of the Total Harmonic Distortion of current (THDi), the Harmonic Amplification Factor of voltage (HAFv) and the Negative Sequence Power (NSP) and is extracted from the efficient Adaline Gauss-Newton algorithm (instead of the conventional Widrow-Hoff delta rule), the input to which are the raw voltage and current at the target DG (where the wind velocity is varied from a minimum to maximum cut-off range). These target feature sets are then utilized by the proposed ELM technique that detects and classifies the islanding events to that of the non-islanding events (switching faults). The proposed DG Model is developed in MATLAB/Simulink environment, and the performance of the proposed ELM technique is compared to some of the conventional techniques in the MATLAB/Editor environment and the results analyzed are satisfactory.
- 1 October 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 979-985
A morphological filter based disturbance detection and classification technique for DFIG wind farm based microgrid
A new morphological filter based disturbance detection and classification technique for DFIG wind farm based micro grid has been proposed in this paper. The structuring element based mathematical morphology with an efficient de-noising characteristics, accurately estimates the signal characteristics and thus is a striking technique for development of the disturbance detection and classification algorithm. The raw voltage and current signals near the target DG (DFIG wind farm) are passed through the morphological filters. Some computations over the morphological signals generate the target feature sets, which comprises of the kurtosis and energy components. These target feature sets are then passed through a decision tree which precisely classifies some of the disturbances such as islanding, switching faults, load switching(balanced and unbalanced), capacitor bank switching, etc., as well as some power quality events such as voltage sag and voltage swell, respectively, which are simulated, tested and verified on a DFIG wind farm based micro grid model in the MATLAB/ SIMULINK environment.
- 1 October 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 979-985
A morphological filter based disturbance detection and classification technique for DFIG wind farm based microgrid
A new morphological filter based disturbance detection and classification technique for DFIG wind farm based micro grid has been proposed in this paper. The structuring element based mathematical morphology with an efficient de-noising characteristics, accurately estimates the signal characteristics and thus is a striking technique for development of the disturbance detection and classification algorithm. The raw voltage and current signals near the target DG (DFIG wind farm) are passed through the morphological filters. Some computations over the morphological signals generate the target feature sets, which comprises of the kurtosis and energy components. These target feature sets are then passed through a decision tree which precisely classifies some of the disturbances such as islanding, switching faults, load switching(balanced and unbalanced), capacitor bank switching, etc., as well as some power quality events such as voltage sag and voltage swell, respectively, which are simulated, tested and verified on a DFIG wind farm based micro grid model in the MATLAB/ SIMULINK environment.
- 1 October 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 290-296
Active and reactive power based feedback linearization control technique for grid-connected voltage source converter
This paper proposes a new feedback linearization control strategy for the grid-connected voltage source converter (VSC). The instantaneous power components at the VSC terminal are being utilized as its dynamic variables. It is due to fact that, as these power components can be directly computed from the three-phase instantaneous voltage and current components measured at the VSC terminal, the need of abc-to-dq transformation, i.e. the unmodelled dynamics of the phase lock loops (PLL) is significantly avoided at this stage. In addition, as these components are being utilized in the proposed feedback linearization control strategy, this becomes an added benefit of reducing the computational complexity of the algorithm with an advantage of improving the stability of the VSC subjected to some intricate disturbances. The robustness and accuracy of the proposed control strategy has been verified in the MATLAB/Editor and it has been proved to be a superior method as compared to the conventional methods as is illustrated in the simulation and result section.
- 1 October 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 290-296
Active and reactive power based feedback linearization control technique for grid-connected voltage source converter
This paper proposes a new feedback linearization control strategy for the grid-connected voltage source converter (VSC). The instantaneous power components at the VSC terminal are being utilized as its dynamic variables. It is due to fact that, as these power components can be directly computed from the three-phase instantaneous voltage and current components measured at the VSC terminal, the need of abc-to-dq transformation, i.e. the unmodelled dynamics of the phase lock loops (PLL) is significantly avoided at this stage. In addition, as these components are being utilized in the proposed feedback linearization control strategy, this becomes an added benefit of reducing the computational complexity of the algorithm with an advantage of improving the stability of the VSC subjected to some intricate disturbances. The robustness and accuracy of the proposed control strategy has been verified in the MATLAB/Editor and it has been proved to be a superior method as compared to the conventional methods as is illustrated in the simulation and result section.
- 10 June 2015
- Published by Hindawi Limited in International Transactions on Electrical Energy Systems
- Vol. 26 (4) , 750-782
Adaptive terminal sliding mode power control of DFIG based wind energy conversion system for stability enhancement
A novel adaptive terminal sliding mode instantaneous active and reactive power control for both the rotor‐side as well as grid‐side converters of the doubly fed induction generator (DFIG) based wind power extraction system is proposed in this paper using the abc frame of reference. This approach is independent of unmodeled dynamics of the phase‐locked loops that reduces the nonlinearities in computing the control objective. The adaptive nature of the terminal sliding mode controller design offers a better and enhanced transient response as compared with some of the conventional methods for a wide range of disturbances such as switching faults, reference tracking and wind speed variation for both the sub‐synchronous and synchronous modes of operation of the doubly fed induction generator subjected to lower and higher wind speeds. Moreover, a maximum power point tracking algorithm has been incorporated to compute the reference power of the stator of the DFIG, which is utilized in designing the control system for the rotor‐side converter. Further extensive computer simulations have been carried out with the DFIG operating in a single machine or multimachine environment to validate the effectiveness of the proposed control. Also the robustness and stability of the proposed adaptive terminal sliding mode control is verified using the MATLAB/SIMULINK based DFIG model. Copyright © 2015 John Wiley & Sons, Ltd.
- 10 June 2015
- Published by Hindawi Limited in International Transactions on Electrical Energy Systems
- Vol. 26 (4) , 750-782
Adaptive terminal sliding mode power control of DFIG based wind energy conversion system for stability enhancement
A novel adaptive terminal sliding mode instantaneous active and reactive power control for both the rotor‐side as well as grid‐side converters of the doubly fed induction generator (DFIG) based wind power extraction system is proposed in this paper using the abc frame of reference. This approach is independent of unmodeled dynamics of the phase‐locked loops that reduces the nonlinearities in computing the control objective. The adaptive nature of the terminal sliding mode controller design offers a better and enhanced transient response as compared with some of the conventional methods for a wide range of disturbances such as switching faults, reference tracking and wind speed variation for both the sub‐synchronous and synchronous modes of operation of the doubly fed induction generator subjected to lower and higher wind speeds. Moreover, a maximum power point tracking algorithm has been incorporated to compute the reference power of the stator of the DFIG, which is utilized in designing the control system for the rotor‐side converter. Further extensive computer simulations have been carried out with the DFIG operating in a single machine or multimachine environment to validate the effectiveness of the proposed control. Also the robustness and stability of the proposed adaptive terminal sliding mode control is verified using the MATLAB/SIMULINK based DFIG model. Copyright © 2015 John Wiley & Sons, Ltd.
- 1 September 2014
- Published by AIP Publishing in Journal of Renewable and Sustainable Energy
- Vol. 6 (5) , 053143
Adaptive second order sliding mode control of doubly fed induction generator in wind energy conversion system
A dynamic synchronous d-q reference frame based modeling and a novel adaptive higher order sliding mode control theory for doubly fed induction generator (DFIG) based wind energy conversion system (WECS) have been proposed in this paper. As depicted from the literature, the sliding mode control strategy involving computation of converter currents introduces some inaccuracies for optimal extraction of the power references of the DFIG. On the contrary, the proposed method contributes with some important features such as chatter-free performance and heftiness in terms of transient response of the non-linear systems subjected to dynamic conditions such as lower and higher wind speeds. Consequently, a higher order sliding mode controller using the active and reactive power of the DFIG as controller inputs has been proposed in this paper. As compared with the other two methods, the proposed higher order sliding mode power control souvenirs a significantly improved as well as stable performance of the DFIG based WECS in terms of reduced settling time as well as quickly damping out the oscillations exhibited by the system. The robustness and stability of the proposed control strategy has been validated in MATLAB environment, in terms of the comparison of its performance with traditional proportional-integral and existing first-order sliding mode controller (employing converter current as input) subjected to a wide range of disturbances for sub and super synchronous mode of operation of the DFIG subjected to lower and higher wind speeds along with the available practical wind speed data, as depicted in the simulation and result section.
- 1 September 2014
- Published by AIP Publishing in Journal of Renewable and Sustainable Energy
- Vol. 6 (5) , 053143
Adaptive second order sliding mode control of doubly fed induction generator in wind energy conversion system
A dynamic synchronous d-q reference frame based modeling and a novel adaptive higher order sliding mode control theory for doubly fed induction generator (DFIG) based wind energy conversion system (WECS) have been proposed in this paper. As depicted from the literature, the sliding mode control strategy involving computation of converter currents introduces some inaccuracies for optimal extraction of the power references of the DFIG. On the contrary, the proposed method contributes with some important features such as chatter-free performance and heftiness in terms of transient response of the non-linear systems subjected to dynamic conditions such as lower and higher wind speeds. Consequently, a higher order sliding mode controller using the active and reactive power of the DFIG as controller inputs has been proposed in this paper. As compared with the other two methods, the proposed higher order sliding mode power control souvenirs a significantly improved as well as stable performance of the DFIG based WECS in terms of reduced settling time as well as quickly damping out the oscillations exhibited by the system. The robustness and stability of the proposed control strategy has been validated in MATLAB environment, in terms of the comparison of its performance with traditional proportional-integral and existing first-order sliding mode controller (employing converter current as input) subjected to a wide range of disturbances for sub and super synchronous mode of operation of the DFIG subjected to lower and higher wind speeds along with the available practical wind speed data, as depicted in the simulation and result section.