Kenneth J Grant
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Kenneth J Grant has a total of 22 co-authors. Here are the top co-authors by number of shared publications:
A J M Gomm
University of Southampton
1 shared publicationA Spizzichino
Istituto TESRE/CNR (Italy)
1 shared publicationA Traci
Istituto TESRE/CNR (Italy)
1 shared publication- Alex G. Brundle
Department of Physics and Astronomy, University of Leicester, Leicester LE17RH, UK
1 shared publication - Amrita Aujla
Department of Physics and Astronomy, University of Leicester, Leicester LE17RH, UK
1 shared publication - Anthony J. Dean
GE Global Research Center
1 shared publication
Latest Publications
- Open Access
Practical Use of Metal Oxide Semiconductor Gas Sensors for Measuring Nitrogen Dioxide and Ozone in Urban Environments
The potential of inexpensive Metal Oxide Semiconductor (MOS) gas sensors to be used for urban air quality monitoring has been the topic of increasing interest in the last decade. This paper discusses some of the lessons of three years of experience working with such sensors on a novel instrument platform (Small Open General purpose Sensor (SOGS)) in the measurement of atmospheric nitrogen dioxide and ozone concentrations. Analytic methods for increasing long-term accuracy of measurements are discussed, which permit nitrogen dioxide measurements with 95% confidence intervals of 20.0 and ozone precision of 26.8 , for measurements over a period one month away from calibration, averaged over 18 months of such calibrations. Beyond four months from calibration, sensor drift becomes significant, and accuracy is significantly reduced. Successful calibration schemes are discussed with the use of controlled artificial atmospheres complementing deployment on a reference weather station exposed to the elements. Manufacturing variation in the attributes of individual sensors are examined, an experiment possible due to the instrument being equipped with pairs of sensors of the same kind. Good repeatability (better than 0.7 correlation) between individual sensor elements is shown. The results from sensors that used fans to push air past an internal sensor element are compared with mounting the sensors on the outside of the enclosure, the latter design increasing effective integration time to more than a day. Finally, possible paths forward are suggested for improving the reliability of this promising sensor technology for measuring pollution in an urban environment.Open AccessPractical Use of Metal Oxide Semiconductor Gas Sensors for Measuring Nitrogen Dioxide and Ozone in Urban Environments
The potential of inexpensive Metal Oxide Semiconductor (MOS) gas sensors to be used for urban air quality monitoring has been the topic of increasing interest in the last decade. This paper discusses some of the lessons of three years of experience working with such sensors on a novel instrument platform (Small Open General purpose Sensor (SOGS)) in the measurement of atmospheric nitrogen dioxide and ozone concentrations. Analytic methods for increasing long-term accuracy of measurements are discussed, which permit nitrogen dioxide measurements with 95% confidence intervals of 20.0 and ozone precision of 26.8 , for measurements over a period one month away from calibration, averaged over 18 months of such calibrations. Beyond four months from calibration, sensor drift becomes significant, and accuracy is significantly reduced. Successful calibration schemes are discussed with the use of controlled artificial atmospheres complementing deployment on a reference weather station exposed to the elements. Manufacturing variation in the attributes of individual sensors are examined, an experiment possible due to the instrument being equipped with pairs of sensors of the same kind. Good repeatability (better than 0.7 correlation) between individual sensor elements is shown. The results from sensors that used fans to push air past an internal sensor element are compared with mounting the sensors on the outside of the enclosure, the latter design increasing effective integration time to more than a day. Finally, possible paths forward are suggested for improving the reliability of this promising sensor technology for measuring pollution in an urban environment. - 1 October 1991
- Published by SPIE-Intl Soc Optical Eng
- Vol. 1549, 102-112
Imager for gamma-ray astronomy: balloon prototype
A novel low energy astronomical gamma-ray detector is being developed for future satellite missions. Recent advances in the technology of photodiodes and small, low noise amplifier circuits have meant that more compact detectors can be assembled in a complex array in order to give a 3-D position reconstruction capability. In a mask-detector telescope this capability is potentially very useful since it allows the reconstruction of the path of the incident gamma rays making it valuable both for imaging and background rejection. A small prototype of a 3-D detector has been realized for test in a balloon mission. The detector is based on a 12 X 8 array of position sensitive CsI(T1) bars, typically 15 cm long with 1.3 X 1.3 cm cross section, viewed at each end by photodiodes. The detector includes four 1.3 X 1.3 X 2.5 cm CsI(T1) scintillators located above the main array in order to evaluate the low energy response of the imager. The detector constitutes an active block of 2400 cm3 of scintillator that can operate in the 0.2 - 10 MeV energy range. The energy resolution is 13% at 662 keV and the positional resolution is of the order of 1.5 cm in each dimension. An active shield of CSI(T1) and plastic scintillators surrounds the bar detector. The overall experiment is briefly described in general and preliminary results of laboratory tests are presented.
- 1 October 1991
- Published by SPIE-Intl Soc Optical Eng
- Vol. 1549, 102-112
Imager for gamma-ray astronomy: balloon prototype
A novel low energy astronomical gamma-ray detector is being developed for future satellite missions. Recent advances in the technology of photodiodes and small, low noise amplifier circuits have meant that more compact detectors can be assembled in a complex array in order to give a 3-D position reconstruction capability. In a mask-detector telescope this capability is potentially very useful since it allows the reconstruction of the path of the incident gamma rays making it valuable both for imaging and background rejection. A small prototype of a 3-D detector has been realized for test in a balloon mission. The detector is based on a 12 X 8 array of position sensitive CsI(T1) bars, typically 15 cm long with 1.3 X 1.3 cm cross section, viewed at each end by photodiodes. The detector includes four 1.3 X 1.3 X 2.5 cm CsI(T1) scintillators located above the main array in order to evaluate the low energy response of the imager. The detector constitutes an active block of 2400 cm3 of scintillator that can operate in the 0.2 - 10 MeV energy range. The energy resolution is 13% at 662 keV and the positional resolution is of the order of 1.5 cm in each dimension. An active shield of CSI(T1) and plastic scintillators surrounds the bar detector. The overall experiment is briefly described in general and preliminary results of laboratory tests are presented.