Mauro Murgia
Research Subjects
Mauro Murgia has a total of 276 co-authors. Here are the top co-authors by number of shared publications:
- Fabio Biscarini
Università di Modena e Reggio Emilia Via Campi 103
32 shared publications - Michele Muccini
Istituto per lo Studio dei Materiali Nanostrutturati, Consiglio nazionale delle ricerche, Bologna, Italy
32 shared publications - Roberto Zamboni
National Research Council, Institute for Organic Synthesis and Photoreactivity (CNR-ISOF), Via P. Gobetti 101, 40129 Bologna, Italy
28 shared publications C. Taliani
Istituto per lo Studio dei Materiali Nanostrutturati ISMN sez. Bologna, Italy
17 shared publications- Giampiero Ruani
Istituto per lo Studio dei Materiali Nanostrutturati (ISMN)Dipartimento di Scienze Chimiche e Tecnologie dei Materiali (DSCTM)Consiglio Nazionale delle Ricerche (CNR) Via P. Gobetti 101 40129 Bologna Italy
17 shared publications - Maria Antonietta Loi
Zernike Institute for Advanced Materials University of Groningen Groningen The Netherlands
15 shared publications
Latest Publications
- Open Access
- 25 November 2024
- Published by Wiley in Advanced Electronic Materials
- Vol. 10 (12)
A Single Electrode Organic Neuromorphic Device for Dopamine Sensing in Vivo
Organic Electronic platforms for biosensing are being demonstrated at a fast pace, especially in healthcare applications where the use of organic (semi‐)conductive materials leads to devices that efficiently interface living matter. Nevertheless, interesting properties of organic (semi‐)conductors are usually neglected in the development of (bio‐)sensors. Among these, the non‐linear response when operated under dynamic biasing conditions (i.e., with pulsed driving voltages), thus mimicking synaptic plasticity phenomena, offers promising and largely unexplored possibilities for bio‐sensing. The artificial synaptic response's figures of merit reflect the composition of the surrounding environment and, ultimately, the ion concentration and dynamics at the organic (semi‐)conductor/electrolyte interface. Therefore, new sensing strategies that rely on the effect of target analytes on the short‐term plasticity response of Organic Neuromorphic Devices are being demonstrated. This work presents the development of a label‐free Single Electrode Neuromorphic Device (SEND) specifically designed for in vivo real‐time mapping of dopamine concentration. The device response is investigated as a function of the driving frequency, resulting in the determination of the optimal operational configuration for minimally invasive neuromorphic devices. It exhibits stable multi‐parametric response in complex fluids, in brain's mechanical models and in vivo, enabling monitoring of local variations of dopamine concentration in the rat brain.
- 25 November 2024
- Published by Wiley in Advanced Electronic Materials
- Vol. 10 (12)
Open AccessA Single Electrode Organic Neuromorphic Device for Dopamine Sensing in Vivo
Organic Electronic platforms for biosensing are being demonstrated at a fast pace, especially in healthcare applications where the use of organic (semi‐)conductive materials leads to devices that efficiently interface living matter. Nevertheless, interesting properties of organic (semi‐)conductors are usually neglected in the development of (bio‐)sensors. Among these, the non‐linear response when operated under dynamic biasing conditions (i.e., with pulsed driving voltages), thus mimicking synaptic plasticity phenomena, offers promising and largely unexplored possibilities for bio‐sensing. The artificial synaptic response's figures of merit reflect the composition of the surrounding environment and, ultimately, the ion concentration and dynamics at the organic (semi‐)conductor/electrolyte interface. Therefore, new sensing strategies that rely on the effect of target analytes on the short‐term plasticity response of Organic Neuromorphic Devices are being demonstrated. This work presents the development of a label‐free Single Electrode Neuromorphic Device (SEND) specifically designed for in vivo real‐time mapping of dopamine concentration. The device response is investigated as a function of the driving frequency, resulting in the determination of the optimal operational configuration for minimally invasive neuromorphic devices. It exhibits stable multi‐parametric response in complex fluids, in brain's mechanical models and in vivo, enabling monitoring of local variations of dopamine concentration in the rat brain.
- Open Access
- 3 March 2022
- Published by Wiley in Advanced Materials Interfaces
- Vol. 9 (11)
A Novel Biasing Scheme of Electrolyte‐Gated Organic Transistors for Safe In Vivo Amplification of Electrophysiological Signals
Successful translation of organic transistors as sensors and transducers to clinical settings is hampered by safety and stability issues. The operation of such devices demands driving voltages across the biotic/abiotic interface, which may result in undesired electrochemical reactions that may harm both the patient and the device. In this study, a novel operational mode is presented for electrolyte‐gated organic transistors that avoid these drawbacks: the common‐drain/grounded‐source configuration. This approach reverts the standard common‐source/common‐ground configuration and achieves maximum signal amplification while applying null net bias across the electrolyte, with no parasitic currents. The viability of the proposed configuration is demonstrated by recording in vivo the somatosensory evoked activity from the barrel cortex of rats. The main inherent advantage of transistors with respect to passive electrodes is preserved in the proposed scheme: a superior signal‐to‐noise ratio is achieved which enables the detection of evoked activity at the single‐trial level. Then, common‐drain/grounded‐source organic transistors are proposed as ideal candidate devices for a harmless translational recording platform.
- 3 March 2022
- Published by Wiley in Advanced Materials Interfaces
- Vol. 9 (11)
Open AccessA Novel Biasing Scheme of Electrolyte‐Gated Organic Transistors for Safe In Vivo Amplification of Electrophysiological Signals
Successful translation of organic transistors as sensors and transducers to clinical settings is hampered by safety and stability issues. The operation of such devices demands driving voltages across the biotic/abiotic interface, which may result in undesired electrochemical reactions that may harm both the patient and the device. In this study, a novel operational mode is presented for electrolyte‐gated organic transistors that avoid these drawbacks: the common‐drain/grounded‐source configuration. This approach reverts the standard common‐source/common‐ground configuration and achieves maximum signal amplification while applying null net bias across the electrolyte, with no parasitic currents. The viability of the proposed configuration is demonstrated by recording in vivo the somatosensory evoked activity from the barrel cortex of rats. The main inherent advantage of transistors with respect to passive electrodes is preserved in the proposed scheme: a superior signal‐to‐noise ratio is achieved which enables the detection of evoked activity at the single‐trial level. Then, common‐drain/grounded‐source organic transistors are proposed as ideal candidate devices for a harmless translational recording platform.
- Open Access
- 20 July 2021
- Published by American Chemical Society (ACS) in ACS Applied Nano Materials
- Vol. 4 (8) , 8376-8382
Atomic Force Microscopy Nanomechanics of Hard Nanometer-Thick Films on Soft Substrates: Insights into Stretchable Conductors
- 20 July 2021
- Published by American Chemical Society (ACS) in ACS Applied Nano Materials
- Vol. 4 (8) , 8376-8382
Open AccessAtomic Force Microscopy Nanomechanics of Hard Nanometer-Thick Films on Soft Substrates: Insights into Stretchable Conductors
- Open Access
- 29 November 2019
- Published by Wiley in Advanced Electronic Materials
- Vol. 6 (1)
A Bacterial Photosynthetic Enzymatic Unit Modulating Organic Transistors with Light
The photochemical core of every photosynthetic apparatus is the reaction center, a transmembrane enzyme that converts photons into charge‐separated states across the biological membrane with an almost unitary quantum yield. A light‐responsive organic transistor architecture, which converts light into electrical current by exploiting the efficiency of this biological machinery, is presented. Proper surface tailoring enables the integration of the bacterial reaction center as photoactive element in organic transistors, allowing the transduction of its photogenerated voltage into photomodulation of the output current up to two orders of magnitude. This device architecture, termed light‐responsive electrolyte‐gated organic transistor, is the prototype of a new generation of low‐power hybrid bio‐optoelectronic organic devices.
- 29 November 2019
- Published by Wiley in Advanced Electronic Materials
- Vol. 6 (1)
Open AccessA Bacterial Photosynthetic Enzymatic Unit Modulating Organic Transistors with Light
The photochemical core of every photosynthetic apparatus is the reaction center, a transmembrane enzyme that converts photons into charge‐separated states across the biological membrane with an almost unitary quantum yield. A light‐responsive organic transistor architecture, which converts light into electrical current by exploiting the efficiency of this biological machinery, is presented. Proper surface tailoring enables the integration of the bacterial reaction center as photoactive element in organic transistors, allowing the transduction of its photogenerated voltage into photomodulation of the output current up to two orders of magnitude. This device architecture, termed light‐responsive electrolyte‐gated organic transistor, is the prototype of a new generation of low‐power hybrid bio‐optoelectronic organic devices.
- 1 November 2019
- Published by Elsevier in Thin Solid Films
- Vol. 690
Understanding adhesion of gold conductive films on sodium-alginate by photoelectron spectroscopy
- 1 November 2019
- Published by Elsevier in Thin Solid Films
- Vol. 690
Understanding adhesion of gold conductive films on sodium-alginate by photoelectron spectroscopy
- 5 September 2019
- Published by Wiley in Advanced Healthcare Materials
- Vol. 8 (19) , e1900765
Electrodeposited PEDOT:Nafion Composite for Neural Recording and Stimulation
Microelectrode arrays are used for recording and stimulation in neurosciences both in vitro and in vivo. The electrodeposition of conductive polymers, such as poly(3,4‐ethylene dioxythiophene) (PEDOT), is widely adopted to improve both the in vivo recording and the charge injection limit of metallic microelectrodes. The workhorse of conductive polymers in the neurosciences is PEDOT:PSS, where PSS represents polystyrene‐sulfonate. In this paper, the counterion is the fluorinated polymer Nafion, so the composite PEDOT:Nafion is deposited onto a flexible neural microelectrode array. PEDOT:Nafion coated electrodes exhibit comparable in vivo recording capability to the reference PEDOT:PSS, providing a large signal‐to‐noise ratio in a murine animal model. Importantly, PEDOT:Nafion exhibits a minimized polarization during electrical stimulation, thereby resulting in an improved charge injection limit equal to 4.4 mC cm−2, almost 80% larger than the 2.5 mC cm−2 that is observed for PEDOT:PSS.
- 5 September 2019
- Published by Wiley in Advanced Healthcare Materials
- Vol. 8 (19) , e1900765
Electrodeposited PEDOT:Nafion Composite for Neural Recording and Stimulation
Microelectrode arrays are used for recording and stimulation in neurosciences both in vitro and in vivo. The electrodeposition of conductive polymers, such as poly(3,4‐ethylene dioxythiophene) (PEDOT), is widely adopted to improve both the in vivo recording and the charge injection limit of metallic microelectrodes. The workhorse of conductive polymers in the neurosciences is PEDOT:PSS, where PSS represents polystyrene‐sulfonate. In this paper, the counterion is the fluorinated polymer Nafion, so the composite PEDOT:Nafion is deposited onto a flexible neural microelectrode array. PEDOT:Nafion coated electrodes exhibit comparable in vivo recording capability to the reference PEDOT:PSS, providing a large signal‐to‐noise ratio in a murine animal model. Importantly, PEDOT:Nafion exhibits a minimized polarization during electrical stimulation, thereby resulting in an improved charge injection limit equal to 4.4 mC cm−2, almost 80% larger than the 2.5 mC cm−2 that is observed for PEDOT:PSS.
- Open Access
- 22 July 2019
- Published by Springer Nature in Scientific Reports
- Vol. 9 (1) , 1-9
Stretchable Low Impedance Electrodes for Bioelectronic Recording from Small Peripheral Nerves
Monitoring of bioelectric signals in peripheral sympathetic nerves of small animal models is crucial to gain understanding of how the autonomic nervous system controls specific body functions related to disease states. Advances in minimally-invasive electrodes for such recordings in chronic conditions rely on electrode materials that show low-impedance ionic/electronic interfaces and elastic mechanical properties compliant with the soft and fragile nerve strands. Here we report a highly stretchable low-impedance electrode realized by microcracked gold films as metallic conductors covered with stretchable conducting polymer composite to facilitate ion-to-electron exchange. The conducting polymer composite based on poly(3,4-ethylenedioxythiophene) polystyrene sulfonate (PEDOT:PSS) obtains its adhesive, low-impedance properties by controlling thickness, plasticizer content and deposition conditions. Atomic Force Microscopy measurements under strain show that the optimized conducting polymer coating is compliant with the micro-crack mechanics of the underlying Au-layer, necessary to absorb the tensile deformation when the electrodes are stretched. We demonstrate functionality of the stretchable electrodes by performing high quality recordings of renal sympathetic nerve activity under chronic conditions in rats.
- 22 July 2019
- Published by Springer Nature in Scientific Reports
- Vol. 9 (1) , 1-9
Open AccessStretchable Low Impedance Electrodes for Bioelectronic Recording from Small Peripheral Nerves
Monitoring of bioelectric signals in peripheral sympathetic nerves of small animal models is crucial to gain understanding of how the autonomic nervous system controls specific body functions related to disease states. Advances in minimally-invasive electrodes for such recordings in chronic conditions rely on electrode materials that show low-impedance ionic/electronic interfaces and elastic mechanical properties compliant with the soft and fragile nerve strands. Here we report a highly stretchable low-impedance electrode realized by microcracked gold films as metallic conductors covered with stretchable conducting polymer composite to facilitate ion-to-electron exchange. The conducting polymer composite based on poly(3,4-ethylenedioxythiophene) polystyrene sulfonate (PEDOT:PSS) obtains its adhesive, low-impedance properties by controlling thickness, plasticizer content and deposition conditions. Atomic Force Microscopy measurements under strain show that the optimized conducting polymer coating is compliant with the micro-crack mechanics of the underlying Au-layer, necessary to absorb the tensile deformation when the electrodes are stretched. We demonstrate functionality of the stretchable electrodes by performing high quality recordings of renal sympathetic nerve activity under chronic conditions in rats.
- 11 November 2016
- Published by American Chemical Society (ACS) in ACS Applied Materials & Interfaces
- Vol. 8 (46) , 31783-31790
The Substrate is a pH-Controlled Second Gate of Electrolyte-Gated Organic Field-Effect Transistor
Electrolyte-gated organic field-effect transistors (EGOFETs), based on ultrathin pentacene films on quartz, were operated with electrolyte solutions whose pH was systematically changed. Transistor parameters exhibit nonmonotonic variation versus pH, which cannot be accounted for by capacitive coupling through the Debye–Helmholtz layer. The data were fitted with an analytical model of the accumulated charge in the EGOFET, where Langmuir adsorption was introduced to describe the pH-dependent charge buildup at the quartz surface. The model provides an excellent fit to the threshold voltage and transfer characteristics as a function of the pH, which demonstrates that quartz acts as a second gate controlled by pH and is mostly effective from neutral to alkaline pH. The effective capacitance of the device is always greater than the capacitance of the electrolyte, thus highlighting the role of the substrate as an important active element for amplification of the transistor response.
- 11 November 2016
- Published by American Chemical Society (ACS) in ACS Applied Materials & Interfaces
- Vol. 8 (46) , 31783-31790
The Substrate is a pH-Controlled Second Gate of Electrolyte-Gated Organic Field-Effect Transistor
Electrolyte-gated organic field-effect transistors (EGOFETs), based on ultrathin pentacene films on quartz, were operated with electrolyte solutions whose pH was systematically changed. Transistor parameters exhibit nonmonotonic variation versus pH, which cannot be accounted for by capacitive coupling through the Debye–Helmholtz layer. The data were fitted with an analytical model of the accumulated charge in the EGOFET, where Langmuir adsorption was introduced to describe the pH-dependent charge buildup at the quartz surface. The model provides an excellent fit to the threshold voltage and transfer characteristics as a function of the pH, which demonstrates that quartz acts as a second gate controlled by pH and is mostly effective from neutral to alkaline pH. The effective capacitance of the device is always greater than the capacitance of the electrolyte, thus highlighting the role of the substrate as an important active element for amplification of the transistor response.
- Open Access
- 1 November 2016
- Published by Elsevier in Organic Electronics
- Vol. 38, 21-28
Electrolyte-gated organic synapse transistor interfaced with neurons
- 1 November 2016
- Published by Elsevier in Organic Electronics
- Vol. 38, 21-28
Open AccessElectrolyte-gated organic synapse transistor interfaced with neurons
- 1 June 2016
- Published by IOP Publishing in Flexible and Printed Electronics
- Vol. 1 (2) , 025005
Water-gated organic transistors on polyethylene naphthalate films
Water-gated organic transistors have been successfully exploited as potentiometric transducers in a variety of sensing applications. The device response does not depend exclusively on the intrinsic properties of the active materials, as the substrate and the device interfaces play a central role. It is therefore important to fine-tune the choice of materials and layout in order to optimize the final device performance. Here, polyethylene naphthalate (PEN) has been chosen as the reference substrate to fabricate and test flexible transistors as bioelectronic transducers in liquid. PEN is a biocompatible substrate that fulfills the requirements for both bio-applications and micro-fabrication technology. Three different semiconducting or conducting polymer thin films employing pentacene, poly(3-hexylthiophene) or poly(3,4-ethylenedioxythiophene):poly(styrenesulfonate) were compared in terms of transconductance, potentiometric sensitivity and response time. The different results allow us to identify material properties crucial for the optimization of organic transistor-based transducers operating in water.
- 1 June 2016
- Published by IOP Publishing in Flexible and Printed Electronics
- Vol. 1 (2) , 025005
Water-gated organic transistors on polyethylene naphthalate films
Water-gated organic transistors have been successfully exploited as potentiometric transducers in a variety of sensing applications. The device response does not depend exclusively on the intrinsic properties of the active materials, as the substrate and the device interfaces play a central role. It is therefore important to fine-tune the choice of materials and layout in order to optimize the final device performance. Here, polyethylene naphthalate (PEN) has been chosen as the reference substrate to fabricate and test flexible transistors as bioelectronic transducers in liquid. PEN is a biocompatible substrate that fulfills the requirements for both bio-applications and micro-fabrication technology. Three different semiconducting or conducting polymer thin films employing pentacene, poly(3-hexylthiophene) or poly(3,4-ethylenedioxythiophene):poly(styrenesulfonate) were compared in terms of transconductance, potentiometric sensitivity and response time. The different results allow us to identify material properties crucial for the optimization of organic transistor-based transducers operating in water.