Ben Stenberg
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Ben Stenberg has a total of 21 co-authors. Here are the top co-authors by number of shared publications:
S. Elliott
Freeman Hospital, Newcastle upon Tyne Hospitals NHS Trust, Newcastle upon Tyne, UK
2 shared publications- Sebastian Mafeld
University of Toronto
2 shared publications Simon Elliott
Department of Radiology, Freeman Hospital, Freeman Road, High Heaton, NE7 7DN Tyne and Wear, United Kingdom
2 shared publicationsA. Kanwar
1 shared publicationAndrew McQueen
Departement of Radiology, Freeman Hospital, Newcastle upon Tyne NHS Hospitals, United Kingdom
1 shared publicationC. Ray
1 shared publication
Latest Publications
- Open Access
- 21 November 2018
- Published by Springer Nature in CardioVascular and Interventional Radiology
- Vol. 42 (4) , 577-583
Percutaneous Irreversible Electroporation (IRE) of Hepatic Malignancy: A Bi-institutional Analysis of Safety and Outcomes
Irreversible electroporation (IRE) is a non-thermal ablative option in patients unsuitable for standard thermal ablation, due to its potential to preserve collagenous structures (vessels and ducts) and a reduced susceptibility to heat sink effects. In this series from two large tertiary referral hepatobiliary centres, we aim to assess the safety/outcomes of hepatic IRE.
- 21 November 2018
- Published by Springer Nature in CardioVascular and Interventional Radiology
- Vol. 42 (4) , 577-583
Open AccessPercutaneous Irreversible Electroporation (IRE) of Hepatic Malignancy: A Bi-institutional Analysis of Safety and Outcomes
Irreversible electroporation (IRE) is a non-thermal ablative option in patients unsuitable for standard thermal ablation, due to its potential to preserve collagenous structures (vessels and ducts) and a reduced susceptibility to heat sink effects. In this series from two large tertiary referral hepatobiliary centres, we aim to assess the safety/outcomes of hepatic IRE.
- 7 June 2017
- Published by Springer Nature in European Radiology
- Vol. 27 (11) , 4525-4531
The prevalence and significance of renal perfusion defects in early kidney transplants quantified using 3D contrast enhanced ultrasound (CEUS)
Vascular complications are one of the most common causes of early kidney transplant dysfunction. Contrast enhanced ultrasound increases sensitivity to vascular changes. The aim of this study was to assess the prevalence and size of vascular abnormalities in early renal transplants using 3D CEUS and the significance of perfusion defects on renal function.
- 7 June 2017
- Published by Springer Nature in European Radiology
- Vol. 27 (11) , 4525-4531
The prevalence and significance of renal perfusion defects in early kidney transplants quantified using 3D contrast enhanced ultrasound (CEUS)
Vascular complications are one of the most common causes of early kidney transplant dysfunction. Contrast enhanced ultrasound increases sensitivity to vascular changes. The aim of this study was to assess the prevalence and size of vascular abnormalities in early renal transplants using 3D CEUS and the significance of perfusion defects on renal function.
- Open Access
- 1 January 2017
- Published by Elsevier in Ultrasound in Medicine & Biology
- Vol. 43, S181-S182
Intra-Operative Ultrasound Guided Trans-Oral Robotic Surgery (TORS) for Recurrent Oropharyngeal Cancers
- 1 January 2017
- Published by Elsevier in Ultrasound in Medicine & Biology
- Vol. 43, S181-S182
Open AccessIntra-Operative Ultrasound Guided Trans-Oral Robotic Surgery (TORS) for Recurrent Oropharyngeal Cancers
- 1 January 2015
- Published by Elsevier in Clinical Imaging
- Vol. 39 (1) , 144-151
Intrarenal arteriovenous shunts in kidney transplants demonstrated by contrast-enhanced ultrasound
- 1 January 2015
- Published by Elsevier in Clinical Imaging
- Vol. 39 (1) , 144-151
Intrarenal arteriovenous shunts in kidney transplants demonstrated by contrast-enhanced ultrasound
- Open Access
- 18 January 2013
- Published by Springer Nature
3D Contrast Enhanced UltraSound in perfusion studies of early renal transplants
- 18 January 2013
- Published by Springer Nature
Open Access3D Contrast Enhanced UltraSound in perfusion studies of early renal transplants
- 16 December 2011
- Published by Georg Thieme Verlag KG in Ultraschall in der Medizin - European Journal of Ultrasound
- Vol. 32 (S 02) , E8-E13
A New Technique for Assessing Renal Transplant Perfusion Preoperatively Using Contrast-Enhanced Ultrasound (CEUS) and Three-Dimensional Ultrasound (3DUS) – A Porcine Model Pilot Study
Ziel: Diese Pilotstudie hat das Ziel, die Durchführbarkeit des kontrastverstärkten Ultraschalls (CEUS) in Nierentransplantaten zu bewerten, die sich vor Transplantation an hypothermen Perfusionsmaschinen befinden. Wir beurteilen die renale Durchblutung der Maschinen-perfundierten porcinen Nieren mit CEUS (Mastricht-Kategorie II). Material und Methoden: 5 Nieren wurden bis zu 24 h nach Ankunft an die hypotherme Maschinenperfusion angeschlossen. Die Nieren wurden dann mit einer Niedrig-MI-kontrastspezifischen Voreinstellung gescannt und ein Bolus von 0,5 ml Sonovue-Kontrastmittel wurde verabreicht. Die kontrastspezifischen Ultraschallbilder wurden in 2-D und 3-D aufgenommen. Ergebnisse: An der Perfusionsmaschine zeigten die 5 Nieren variable Flussraten (10 – 37 ml/min bei 30 mmHg). Die CEUS-Technik stellte in 4 Nieren gute Perfusion und Strömungsprofile dar, die den in vivo gesehenen entsprachen. Eine Niere hatte bis zur interlobären Region durchgängige Arterien, aber keine Kontrastfüllung in Rinde oder Mark. Kleine Perfusionsdefekte wurden in 2 der perfundierten Nieren gesehen. Schlussfolgerung: CEUS scheint eine brauchbare Methode zur Bestimmung der globalen Perfusion und kleiner Defekte in Nieren vor Transplantation zu sein. Die Flussmuster in vitro scheinen denen in vivo zu entsprechen und es ist noch weitere Arbeit erforderlich, um die Relevanz der gemessenen Durchflussdynamiken zu bewerten. Purpose: This pilot study aims to assess the viability of using contrast-enhanced ultrasound (CEUS) in renal grafts while they are on hypothermic perfusion machines prior to transplantation. We assessed the vascularity and renal perfusion of machine-perfused porcine kidneys (Maastricht category II) using CEUS. Materials and Methods: Five kidneys were placed on hypothermic machine perfusion for up to 24 hours after retrieval. The kidneys were then scanned with a low MI contrast-specific preset and a bolus of 0.5ml of Sonovue contrast agent was administered. Contrast-specific ultrasound images of the kidney were acquired in 2D and 3D. Results: The five kidneys demonstrated variable flow rates on the perfusion machine (10 – 37 ml/min at 30 mmHg). The CEUS technique demonstrated good perfusion and flow patterns, similar to those seen in vivo, in four kidneys. One kidney had patent arteries up to the interlobar region but no contrast filling in the cortex or medulla. Small perfusion defects were seen in two of the perfused kidneys. Conclusion: CEUS appears to be a viable technique for assessing global perfusion and small defects within kidneys prior to transplantation. The flow patterns seen in vitro appear to correspond to those seen in vivo. Further work is required to evaluate the relevance of the flow dynamics measured.
- 16 December 2011
- Published by Georg Thieme Verlag KG in Ultraschall in der Medizin - European Journal of Ultrasound
- Vol. 32 (S 02) , E8-E13
A New Technique for Assessing Renal Transplant Perfusion Preoperatively Using Contrast-Enhanced Ultrasound (CEUS) and Three-Dimensional Ultrasound (3DUS) – A Porcine Model Pilot Study
Ziel: Diese Pilotstudie hat das Ziel, die Durchführbarkeit des kontrastverstärkten Ultraschalls (CEUS) in Nierentransplantaten zu bewerten, die sich vor Transplantation an hypothermen Perfusionsmaschinen befinden. Wir beurteilen die renale Durchblutung der Maschinen-perfundierten porcinen Nieren mit CEUS (Mastricht-Kategorie II). Material und Methoden: 5 Nieren wurden bis zu 24 h nach Ankunft an die hypotherme Maschinenperfusion angeschlossen. Die Nieren wurden dann mit einer Niedrig-MI-kontrastspezifischen Voreinstellung gescannt und ein Bolus von 0,5 ml Sonovue-Kontrastmittel wurde verabreicht. Die kontrastspezifischen Ultraschallbilder wurden in 2-D und 3-D aufgenommen. Ergebnisse: An der Perfusionsmaschine zeigten die 5 Nieren variable Flussraten (10 – 37 ml/min bei 30 mmHg). Die CEUS-Technik stellte in 4 Nieren gute Perfusion und Strömungsprofile dar, die den in vivo gesehenen entsprachen. Eine Niere hatte bis zur interlobären Region durchgängige Arterien, aber keine Kontrastfüllung in Rinde oder Mark. Kleine Perfusionsdefekte wurden in 2 der perfundierten Nieren gesehen. Schlussfolgerung: CEUS scheint eine brauchbare Methode zur Bestimmung der globalen Perfusion und kleiner Defekte in Nieren vor Transplantation zu sein. Die Flussmuster in vitro scheinen denen in vivo zu entsprechen und es ist noch weitere Arbeit erforderlich, um die Relevanz der gemessenen Durchflussdynamiken zu bewerten. Purpose: This pilot study aims to assess the viability of using contrast-enhanced ultrasound (CEUS) in renal grafts while they are on hypothermic perfusion machines prior to transplantation. We assessed the vascularity and renal perfusion of machine-perfused porcine kidneys (Maastricht category II) using CEUS. Materials and Methods: Five kidneys were placed on hypothermic machine perfusion for up to 24 hours after retrieval. The kidneys were then scanned with a low MI contrast-specific preset and a bolus of 0.5ml of Sonovue contrast agent was administered. Contrast-specific ultrasound images of the kidney were acquired in 2D and 3D. Results: The five kidneys demonstrated variable flow rates on the perfusion machine (10 – 37 ml/min at 30 mmHg). The CEUS technique demonstrated good perfusion and flow patterns, similar to those seen in vivo, in four kidneys. One kidney had patent arteries up to the interlobar region but no contrast filling in the cortex or medulla. Small perfusion defects were seen in two of the perfused kidneys. Conclusion: CEUS appears to be a viable technique for assessing global perfusion and small defects within kidneys prior to transplantation. The flow patterns seen in vitro appear to correspond to those seen in vivo. Further work is required to evaluate the relevance of the flow dynamics measured.
- 30 September 2009
- Published by Springer Nature in European Radiology
- Vol. 20 (4) , 908-914
Diagnosis of gallbladder problems using three-dimensional ultrasound
Objective The purpose of this study was to determine whether offline reported three-dimensional ultrasound (3DUS) is as accurate as standard two-dimensional ultrasound (2DUS) with regard to demonstrating gallbladder disease. Method The cohort comprised 80 consecutive patients referred for an abdominal ultrasound examination. The participants underwent routine 2DUS assessment of the gallbladder followed by the acquisition of two 3DUS volumes of the region of the gall bladder. The two techniques were reported independently of each other, and the diagnoses were compared for correlation. Results There was overall agreement of the two techniques in 89% of cases with a positive predictive value of 89%, negative predictive value of 91% and a specificity of 86%. Small polyps (sub-4 mm) were the only positive discrepancies. Cohen’s kappa found that there was substantial agreement between the two techniques (p = 0.05 for a two-tailed kappa 0.67), and chi-squared test found no significant difference in diagnoses (p = 0.95). Conclusion This study shows that 3DUS diagnosis correlates well with 2DUS with regard to most gallbladder problems and could be sufficient as a stand-alone technique.
- 30 September 2009
- Published by Springer Nature in European Radiology
- Vol. 20 (4) , 908-914
Diagnosis of gallbladder problems using three-dimensional ultrasound
Objective The purpose of this study was to determine whether offline reported three-dimensional ultrasound (3DUS) is as accurate as standard two-dimensional ultrasound (2DUS) with regard to demonstrating gallbladder disease. Method The cohort comprised 80 consecutive patients referred for an abdominal ultrasound examination. The participants underwent routine 2DUS assessment of the gallbladder followed by the acquisition of two 3DUS volumes of the region of the gall bladder. The two techniques were reported independently of each other, and the diagnoses were compared for correlation. Results There was overall agreement of the two techniques in 89% of cases with a positive predictive value of 89%, negative predictive value of 91% and a specificity of 86%. Small polyps (sub-4 mm) were the only positive discrepancies. Cohen’s kappa found that there was substantial agreement between the two techniques (p = 0.05 for a two-tailed kappa 0.67), and chi-squared test found no significant difference in diagnoses (p = 0.95). Conclusion This study shows that 3DUS diagnosis correlates well with 2DUS with regard to most gallbladder problems and could be sufficient as a stand-alone technique.