GBGopalakrishnan Balasubramanian

Gopalakrishnan Balasubramanian

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Gopalakrishnan Balasubramanian has a total of 137 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Nitrogen-vacancy centers as a self-gauged micro-scale heater and its application for multi-modal sensing

    by Dewen Duan, Vinaya Kumar Kavatamane, Sri Ranjini Arumugam, Huan-Cheng Chang, Gopalakrishnan Balasubramanian

    The optical excitation of nitrogen-vacancy (NV) color centers in diamonds mostly results in fluorescence emission. During this process, a portion of the incident energy is transferred to phonon vibration, which heats the diamond crystal. For single NV color centers, the heat generated by the optical cycle is negligible, while for an ensemble of NV defects, the generated heat accumulates rapidly and heats the diamond. The temperature rise is rapid due to the high thermal conductivity of the diamond. In addition to the ability to be heated by light, the NV defect's unique properties also allow for the precise measurement of temperature using optically detected magnetic resonance. Here, we experimentally demonstrate that microcrystalline diamond containing NV center ensembles can be used as a self-gauged microheater. We attached a microcrystal diamond to an optical fiber in an endoscope configuration, evaluated its performance as a self-gauged heater under varied biologically relevant environments, and discussed its potential applications. In addition to the aforementioned capabilities, the NV defect enables the precise measurement of local magnetic fields. This provides a unique multimodal sensor to probe temperature-controlled magnetic phenomena at microscopic scales.


  • Magnetic sensing at zero field with a single nitrogen-vacancy center

    by Till Lenz, Arne Wickenbrock, Fedor Jelezko, Gopalakrishnan Balasubramanian, Dmitry Budker

    Single nitrogen-vacancy (NV) centers are widely used as nanoscale sensors for magnetic and electric fields, strain and temperature. Nanoscale magnetometry using NV centers allows for example to quantitatively measure local magnetic fields produced by vortices in superconductors, topological spin textures such as skyrmions, as well as to detect nuclear magnetic resonance signals. However, one drawback when used as magnetic field sensor has been that an external bias field is required to perform magnetometry with NV centers. In this work we demonstrate a technique which allows access to a regime where no external bias field is needed. This enables new applications in which this bias field might disturb the system under investigation. Furthermore, we show that our technique is sensitive enough to detect spins outside of the diamond which enables nanoscale zero-to ultralow-field nuclear magnetic resonance.


  • Open Access

    Tapered ultra-high numerical aperture optical fiber tip for nitrogen vacancy ensembles based endoscope in a fluidic environment

    by Dewen Duan, Vinaya Kumar Kavatamane, Sri Ranjini Arumugam, Yan-Kai Tzeng, Huan-Cheng Chang, Gopalakrishnan Balasubramanian

    Fixing a diamond containing a high density of Nitrogen-Vacancy (NV) center ensembles on the apex of a multimode optical fiber (MMF) extends the applications of NV-based endoscope sensors. Replacing the normal MMF with a tapered MMF (MMF-taper) has enhanced the fluorescence (FL) collection efficiency from the diamond and achieved a high spatial resolution NV-based endoscope. The MMF-taper's high FL collection efficiency is the direct result of multiple internal reflections in the tapered region caused by silica, which has a higher refractive index (RI) than the surrounding air. However, for applications involving fluidic environments whose RI is close to or higher than that of the silica, the MMF-taper loses its FL collection significantly. Here, to overcome this challenge and achieve a high spatial resolution NV-based endoscope in a fluidic environment, we conceptually proposed a tapered ultra-high numerical aperture microstructured optical fiber (MOF) whose air capillaries at the tapered end are sealed. Since the end-sealed air capillaries along the tapered MOF (MOF-taper) have isolated the MOF core from the surrounding medium, the core retains its high FL collection and NV excitation efficiency in liquids regardless of their RI values. Replacing the MMF-taper with the MOF-taper will achieve a versatile NV-based endoscope that could potentially find widespread applications in fluidic environments where many biological processes and chemical reactions occur.


  • Open Access

    Tapered ultra-high Numerical Aperture optical fiber tip for Nitrogen Vacancy ensembles based endoscope in a fluidic environment

    by Dewen Duan, Vinaya Kumar Kavatamane, Sri Ranjini Arumugam, Yan-Kai Tzeng, Huan-Cheng Chang, Gopalakrishnan Balasubramanian

    Fixing a diamond containing a high density of Nitrogen-Vacancy (NV) center ensembles on the apex of a multimode optical fiber (MMF) extends the applications of NV-based endoscope sensors. Replacing the normal MMF with a tapered MMF (MMF-taper) has enhanced the fluorescence (FL) collection efficiency from the diamond and achieved a high spatial resolution NV-based endoscope. The MMF-taper's high FL collection efficiency is the direct result of multiple internal reflections in the tapered region caused by silica, which has a higher refractive index (RI) than the surrounding air. However, for applications involving fluidic environments whose RI is close to or higher than that of the silica, the MMF-taper loses its FL collection significantly. Here, to overcome this challenge, we replaced the MMF-taper with an ultra-high numerical aperture (NA) microstructured optical fiber (MOF) which is tapered and sealed its air capillaries at the tapered end. Since the end-sealed air capillaries along the tapered MOF (MOF-taper) have isolated the MOF core from the surrounding medium, the core retains its high FL collection and NV excitation efficiency in liquids regardless of their RI values. Such a versatile NV-based endoscope could potentially find broad applications in fluidic environments where many biological processes and chemical reactions occur.

  • Open Access

    Probing phase transitions in a soft matter system using a single spin quantum sensor

    by Vinaya Kumar Kavatamane, Dewen Duan, Sri Ranjini Arumugam, Nicole Raatz, Sebastian Pezzagna, Jan Meijer, Gopalakrishnan Balasubramanian

    Phase transitions in soft matter systems reveal some of the interesting structural phenomena at the levels of individual entities constituting those systems. The relevant energy scales in soft matter systems are comparable to thermal energy (k B T ∼ 10−21 J). This permits one to observe interesting structural dynamics even at ambient conditions. However, at the nanoscale most experimental probes currently being used to study these systems have been either plagued by low sensitivity or are invasive at molecular scales. Nitrogen-vacancy (NV) centers in diamond is emerging as a robust quantum probe for precision metrology of physical quantities (e.g. magnetic field, electric field, temperature, and stress). Here, we demonstrate by using NV sensors to probe spin-fluctuations and temperature simultaneously to obtain information about controlled phase changes in a soft matter material as a function of temperature. The soft matter system chosen for the study is a standard liquid crystalline (LC) material which shows distinct phases close to room temperature. Individual NV centers at depths of a few nm are used as a probe to detect magnetic signals emanating from a few molecular layers of sample on the surface of the diamond. The organization and collective dynamics of LC molecules in nanoscopic volumes are discussed. Our study aims to extend the areas of application of quantum sensing using NV centers to probe the soft matter systems, particularly those exhibiting mesophases and interesting interfacial properties.


  • Laser-induced heating in a high-density ensemble of nitrogen-vacancy centers in diamond and its effects on quantum sensing

    by Dewen Duan, Vinaya Kumar Kavatamane, Sri Ranjini Arumugam, Ganesh Rahane, Guan-Xiang Du, Yan-Kai Tzeng, Huan-Cheng Chang, Gopalakrishnan Balasubramanian

    Among quantum sensors, the single nitrogen-vacancy (NV) defect in diamond has the highest sensitivity-to-size factor. For instance, a single-NV spin when used as a magnetometer could achieve sensitivities of the order of nT/Hz, while the dimensions of the sensor are merely atomic in size. The sensitivity is limited only by the photon shot noise. One method to boost the magnetometer sensitivity to pico-tesla scales is to use many NV defect centers as an ensemble sensor [Phys. Rev. X 5, 041001 (2015) [CrossRef] ]. However, during the absorption-emission (fluorescence) optical cycles, the NV centers transfer a portion of the irradiation laser energy into phonons and heat the diamond matrix. This results in unintended fluorescence decrease, spin resonance lines shifts, and fluctuations. Hence, the advantages gained by packing a high density of NV centers are significantly reduced. Here we investigate the heat generation of ensemble NV centers in micrometer-sized diamond under 532 nm laser irradiation and its effects pertaining to sensing applications. These investigations help us to find strategies that mitigate the detrimental effects of heating and yet permits the use of ensemble NV defects for improved metrology applications.


  • Efficient nitrogen-vacancy centers’ fluorescence excitation and collection from micrometer-sized diamond by a tapered optical fiber in endoscope-type configuration

    by D. Duan, G. X. Du, V. K. Kavatamane, S. Arumugam, Y.-K. Tzeng, H-C Chang, G. Balasubramanian

    Using an optical fiber to both excite the nitrogen-vacancy (NV) center in diamond and collect its fluorescence is essential to build NV-based endoscope-type sensor. Such endoscope-type sensor can reach inaccessible fields for traditional NV-based sensors built by bulky optical components and extend the application areas. Since single NV’s fluorescence is weak and can easily be buried in fluorescence from optical fiber core’s oxide defects excited by the green laser, fixing a micrometer size diamond containing high-density NVs rather than a nanodiamond containing single NV or several NVs on the apex of an optical fiber to build an endoscope-type sensor is more implementable. Unfortunately, due to small numerical aperture (NA), most of the optical fibers have a low fluorescence collection efficiency, which limits the sensitivity and spatial resolution of the NV-based endoscope-type sensor. Here, using a tapered optical fiber (TOF) tip, we significantly improve the efficiency of the laser excitation and fluorescence collection of the NV ensembles in diamond. This could potentially enhance the sensitivity and spatial resolution of the NV-based endoscope-type sensor. Numerical calculations show that the TOF tip delivers a high NA and has a high NV excitation and fluorescence collection efficiency. Experiments demonstrate that such TOF tip can obtain up to over 7-fold excitation efficiency and over 15-fold fluorescence collection efficiency of that from a flat-ended fiber (non-TOF) tip.


  • Open Access

    Enhancing fluorescence excitation and collection from the nitrogen-vacancy center in diamond through a micro-concave mirror

    by Dewen Duan, Vinaya Kumar Kavatamane, Sri Ranjini Arumugam, Ganesh Rahane, Yan-Kai Tzeng, Huan-Cheng Chang, Hitoshi Sumiya, Shinobu Onoda, Junichi Isoya, Gopalakrishnan Balasubramanian

    We experimentally demonstrate a simple and robust optical fibers based method to achieve simultaneously efficient excitation and fluorescence collection from Nitrogen-Vacancy (NV) defects containing micro-crystalline diamond. We fabricate a suitable micro-concave (MC) mirror that focuses scattered excitation laser light into the diamond located at the focal point of the mirror. At the same instance, the mirror also couples the fluorescence light exiting out of the diamond crystal in the opposite direction of the optical fiber back into the optical fiber within its light acceptance cone. This part of fluorescence would have been otherwise lost from reaching the detector. Our proof-of-principle demonstration achieves a 25 times improvement in fluorescence collection compared to the case of not using any mirrors. The increase in light collection favors getting high signal-to-noise ratio (SNR) optically detected magnetic resonance (ODMR) signals hence offers a practical advantage in fiber-based NV quantum sensors. Additionally, we compacted the NV sensor system by replacing some bulky optical elements in the optical path with a 1x2 fiber optical coupler in our optical system. This reduces the complexity of the system and provides portability and robustness needed for applications like magnetic endoscopy and remote-magnetic sensing.

  • Open Access

    Enhancing fluorescence excitation and collection from the nitrogen-vacancy center in diamond through a micro-concave mirror

    by Dewen Duan, Vinaya Kumar Kavatamane, Sri Ranjini Arumugam, Ganesh Rahane, Yan-Kai Tzeng, Huan-Cheng Chang, Hitoshi Sumiya, Shinobu Onoda, Junichi Isoya, Gopalakrishnan Balasubramanian

    We experimentally demonstrate a simple and robust optical fiber based method to achieve simultaneously efficient excitation and fluorescence collection from Nitrogen-Vacancy (NV) defects containing micro-crystalline diamond. We fabricate a suitable micro-concave mirror that focuses scattered excitation laser light into the diamond located at the focal point of the mirror. At the same instance, the mirror also couples the fluorescence light exiting out of the diamond crystal in the opposite direction of the optical fiber back into the optical fiber within its light acceptance cone. This part of fluorescence would have been otherwise lost from reaching the detector. Our proof-of-principle demonstration achieves a 25 times improvement in fluorescence collection compared to the case of not using any mirrors. The increase in light collection favors getting high signal-to-noise ratio optically detected magnetic resonance signals and hence offers a practical advantage in fiber-based NV quantum sensors. Additionally, we compacted the NV sensor system by replacing some bulky optical elements in the optical path with a 1 × 2 fiber optical coupler in our optical system. This reduces the complexity of the system and provides portability and robustness needed for applications like magnetic endoscopy and remote-magnetic sensing.


  • Open Access

    Dynamical sensitivity control of a single-spin quantum sensor

    by Andrii Lazariev, Silvia Arroyo-Camejo, Ganesh Rahane, Vinaya Kumar Kavatamane, Gopalakrishnan Balasubramanian

    The Nitrogen-Vacancy (NV) defect in diamond is a unique quantum system that offers precision sensing of nanoscale physical quantities at room temperature beyond the current state-of-the-art. The benchmark parameters for nanoscale magnetometry applications are sensitivity, spectral resolution, and dynamic range. Under realistic conditions the NV sensors controlled by conventional sensing schemes suffer from limitations of these parameters. Here we experimentally show a new method called dynamical sensitivity control (DYSCO) that boost the benchmark parameters and thus extends the practical applicability of the NV spin for nanoscale sensing. In contrast to conventional dynamical decoupling schemes, where π pulse trains toggle the spin precession abruptly, the DYSCO method allows for a smooth, analog modulation of the quantum probe’s sensitivity. Our method decouples frequency selectivity and spectral resolution unconstrained over the bandwidth (1.85 MHz–392 Hz in our experiments). Using DYSCO we demonstrate high-accuracy NV magnetometry without |2π| ambiguities, an enhancement of the dynamic range by a factor of 4 · 103, and interrogation times exceeding 2 ms in off-the-shelf diamond. In a broader perspective the DYSCO method provides a handle on the inherent dynamics of quantum systems offering decisive advantages for NV centre based applications notably in quantum information and single molecule NMR/MRI.