SHShun-Hsi Hsu

Shun-Hsi Hsu

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Shun-Hsi Hsu has a total of 16 co-authors. Here are the top co-authors by number of shared publications:

  • Cheng-Kai Kuei

    Institute of Electrical and Control Engineering, National Chiao-Tung University, Taiwan

    1 shared publication
  • Cheng-Kai Kuei

    Institute of Electrical Control Engineering, National Chiao-Tung University, Room 617, Engineering Building 5, No. 1001, Ta Hsueh Rd., Hsinchu 30010, Taiwan

    1 shared publication
  • Cheng‐Wei Tsai

    Department of Electrical and Computer Engineering National Yang Ming Chiao Tung University, No. 1001, Ta Hsueh Rd. Hsinchu 30010 Taiwan, Republic of China

    1 shared publication
  • Cheng‐Yu Hsu

    Department of Electrical and Computer Engineering National Yang Ming Chiao Tung University, No. 1001, Ta Hsueh Rd. Hsinchu 30010 Taiwan, Republic of China

    1 shared publication
  • Chun‐Yu Wu

    Department of Electrical and Computer Engineering National Yang Ming Chiao Tung University, No. 1001, Ta Hsueh Rd. Hsinchu 30010 Taiwan, Republic of China

    1 shared publication
  • Guan-Ting Yeh

    Institute of Electrical Control Engineering, National Chiao-Tung University, Room 617, Engineering Building 5, No. 1001, Ta Hsueh Rd., Hsinchu 30010, Taiwan

    1 shared publication

Latest Publications

  • A Semi‐Passive Smart Contact Lens with on‐Lens Power Storage Element

    by Cheng‐Wei Tsai, Shun‐Hsi Hsu, Guan‐Ting Yeh, Yu‐Hsuan Huang, Cheng‐Yu Hsu, Chun‐Yu Wu, Jhu‐Jyun Yang, Xuan‐Wei Zhang, Jin‐Chern Chiou


  • Open Access

    A Wirelessly Powered Smart Contact Lens with Reconfigurable Wide Range and Tunable Sensitivity Sensor Readout Circuitry

    by Jin-Chern Chiou, Shun-Hsi Hsu, Yu-Chieh Huang, Guan-Ting Yeh, Wei-Ting Liou, Cheng-Kai Kuei

    This study presented a wireless smart contact lens system that was composed of a reconfigurable capacitive sensor interface circuitry and wirelessly powered radio-frequency identification (RFID) addressable system for sensor control and data communication. In order to improve compliance and reduce user discomfort, a capacitive sensor was embedded on a soft contact lens of 200 μm thickness using commercially available bio-compatible lens material and a standard manufacturing process. The results indicated that the reconfigurable sensor interface achieved sensitivity and baseline tuning up to 120 pF while consuming only 110 μW power. The range and sensitivity tuning of the readout circuitry ensured a reliable operation with respect to sensor fabrication variations and independent calibration of the sensor baseline for individuals. The on-chip voltage scaling allowed the further extension of the detection range and prevented the implementation of large on-chip elements. The on-lens system enabled the detection of capacitive variation caused by pressure changes in the range of 2.25 to 30 mmHg and hydration level variation from a distance of 1 cm using incident power from an RFID reader at 26.5 dBm.


  • An addressable UHF EPCGlobal Class1 Gen2 Sensor IC for wireless IOP monitoring on contact lens

    by Jin-Chern Chiou, Shun-Hsi Hsu, Cheng-Kai Kuei, Tsung-Wei Wu

    In this paper, an addressable UHF EPCGlobal Class1 Gen2 sensor IC for wireless intraocular pressure (IOP) monitoring on contact lens sensor device is proposed. The proposed sensor IC consists of RFID Analog/RF Front End, capacitive sensor readout circuit, and digital processing unit. RFID Analog/RF front end is used for power management and data transmission. Sensor Readout Circuit will convert the measured capacitor value to digital format for digital processing unit. Digital processing unit is used as processor not only for sensor value processing obtained from the sensor readout circuit, but also for bidirectional communication between RFID reader and sensor IC. This sensor IC architecture combined with specific sensor and corresponding sensor readout circuit can be widely used as noninvasive biomedical sensor devices and systems. Wireless communication and sensor data transmission are implemented with UHF RFID technology, providing much flexibility and can reduce self-developed firmware effort for this architecture in the future.