Karunakaravel Karuppasamy
Research Subjects
Karunakaravel Karuppasamy has a total of 113 co-authors. Here are the top co-authors by number of shared publications:
Abraham Levitin
Interventional Radiology, Cleveland Clinic, Ohio, United States
4 shared publications- Prabhakar Rajiah
Department of Radiology, Mayo Clinic, Rochester, Minn
4 shared publications Sasan Partovi
3 shared publicationsAbed Ghandour
2 shared publications- Abed Ghandour
Imaging Institute, Cleveland Clinic, Cleveland, Ohio, USA
2 shared publications Amanjit Gill
Interventional Radiology, Cleveland Clinic, Ohio, United States
2 shared publications
Latest Publications
- 19 October 2023
- Published by Springer Nature in Current Cardiology Reports
- Vol. 25 (11) , 1433-1441
Computed Tomography–Guided Pericardiocentesis: A Practical Guide
Purpose of Review The purpose of this article is to serve as a practical guide to computed tomography (CT)–guided pericardiocentesis and to discuss the role of this approach in current clinical practice. An overview of indications, technique, advantages, and limitations specific to CT-guided pericardiocentesis will be provided. The reader will have an enhanced understanding of the use of this imaging modality to guide pericardial drainage. Recent Findings Use of CT guidance to drain the pericardial space is safe, especially when adequate echocardiographic evaluation is precluded and when echocardiography-guided pericardiocentesis is deemed unsafe and or not feasible. Summary Our review and experience indicate that CT-guided pericardiocentesis is technically successful in more than 94% of patients, with a low risk (<1%) of significant complications. CT-guided pericardiocentesis is therefore a viable alternative when echocardiographic guidance is insufficient and can obviate the need for surgery in most patients.
- 19 October 2023
- Published by Springer Nature in Current Cardiology Reports
- Vol. 25 (11) , 1433-1441
Computed Tomography–Guided Pericardiocentesis: A Practical Guide
Purpose of Review The purpose of this article is to serve as a practical guide to computed tomography (CT)–guided pericardiocentesis and to discuss the role of this approach in current clinical practice. An overview of indications, technique, advantages, and limitations specific to CT-guided pericardiocentesis will be provided. The reader will have an enhanced understanding of the use of this imaging modality to guide pericardial drainage. Recent Findings Use of CT guidance to drain the pericardial space is safe, especially when adequate echocardiographic evaluation is precluded and when echocardiography-guided pericardiocentesis is deemed unsafe and or not feasible. Summary Our review and experience indicate that CT-guided pericardiocentesis is technically successful in more than 94% of patients, with a low risk (<1%) of significant complications. CT-guided pericardiocentesis is therefore a viable alternative when echocardiographic guidance is insufficient and can obviate the need for surgery in most patients.
- 20 December 2022
- Published by Elsevier in Journal of Vascular and Interventional Radiology
- Vol. 34 (5) , 790-798
Semiautomatic Cone-Beam Computed Tomography Virtual Hepatic Volumetry for Intra-Arterial Therapies
- 20 December 2022
- Published by Elsevier in Journal of Vascular and Interventional Radiology
- Vol. 34 (5) , 790-798
Semiautomatic Cone-Beam Computed Tomography Virtual Hepatic Volumetry for Intra-Arterial Therapies
- 1 May 2021
- Published by Elsevier in Journal of the American College of Radiology
- Vol. 18 (5) , S139-S152
ACR Appropriateness Criteria® Radiologic Management of Lower Gastrointestinal Tract Bleeding: 2021 Update
- 1 May 2021
- Published by Elsevier in Journal of the American College of Radiology
- Vol. 18 (5) , S139-S152
ACR Appropriateness Criteria® Radiologic Management of Lower Gastrointestinal Tract Bleeding: 2021 Update
- Open Access
- 18 January 2021
- Published by Oxford University Press (OUP) in Annals of Work Exposures and Health
- Vol. 65 (4) , 463-474
Comparison of Fit for Sealed and Loose-Fitting Surgical Masks and N95 Filtering Facepiece Respirators
Objectives: N95 filtering facepiece respirators (N95 FFRs) and surgical masks are comprised of multiple layers of nonwoven polypropylene. Tight-fitting N95 FFRs are respiratory protective devices (RPDs) designed to efficiently filter aerosols. During the COVID-19 pandemic, health care workers (HCWs) throughout the world continue to face shortages of disposable N95 FFRs. Existing version of widely available FDA cleared loose-fitting surgical masks with straps do not provide reliable protection against aerosols. We tested the faceseal of a modified strapless form-fitting sealed version of surgical mask using quantitative fit testing (QNFT) and compared the performance of this mask with that of N95 FFRs and unmodified loose-fitting surgical masks. Methods: Twenty HCWs participated in the study (10 women; 10 men; age 23–59 years). To create the sealed surgical masks, we removed the straps from loose-fitting surgical masks, made new folds, and used adhesive medical tape to secure the new design. All participants underwent QNFT with a loose-fitting surgical mask, the sealed surgical mask, and an N95 FFR; fit factors were recorded. Each QNFT was performed using a protocol of four exercises: (i) bending over, (ii) talking, (iii) moving head side to side, and (iv) moving head up and down. When the overall fit factor for the sealed surgical mask or N95 FFR was <100, the participant retook the test. Participants scored the breathability and comfort of the sealed surgical mask and N95 FFR on a visual analog scale (VAS) ranging from 0 (unfavorable) to 10 (favorable). Results: The median fit factor for the sealed surgical mask (53.8) was significantly higher than that of the loose-fitting surgical mask (3.0) but lower than that of the N95 FFR (177.0) (P < 0.001), equating to significantly lower inward leakage of ambient aerosols (measuring 0.04–0.06 µm) with the sealed surgical mask (geometric mean 1.79%; geometric standard deviation 1.45%; range 0.97–4.03%) than with the loose-fitting surgical mask (29.5%; 2.01%; 25–100.0%) but still higher than with the N95 FFR (0.66%; 1.46%; 0.50–1.97%) (P < 0.001). Sealed surgical masks led to a marked reduction (range 60–98%) in inward leakage of aerosols in all the participants, compared to loose-fitting surgical masks. Among the exercises, talking had a greater effect on reducing overall fit factor for the sealed surgical mask than for the N95 FFR; when talking was excluded, the fit factor for the sealed surgical mask improved significantly (median 53.8 to 81.5; P < 0.001). The sealed surgical mask, when compared with the N95 FFR, offered better reported breathability (median VAS 9 versus 5; P < 0.001) and comfort (9 versus 5; P < 0.001). Conclusions: Widely available loose-fitting surgical masks can be easily modified to achieve faceseal with adhesives. Unlike loose-fitting surgical masks, sealed surgical masks can markedly reduce inward leakage of aerosols and may therefore offer useful levels of respiratory protection during an extreme shortage of N95 FFRs and could benefit HCWs who cannot comply with N95 FFRs due to intolerance. However, because a wide range of surgical masks is commercially available, individual evaluation of such masks is highly recommended before sealed versions are used as RPDs.
- 18 January 2021
- Published by Oxford University Press (OUP) in Annals of Work Exposures and Health
- Vol. 65 (4) , 463-474
Open AccessComparison of Fit for Sealed and Loose-Fitting Surgical Masks and N95 Filtering Facepiece Respirators
Objectives: N95 filtering facepiece respirators (N95 FFRs) and surgical masks are comprised of multiple layers of nonwoven polypropylene. Tight-fitting N95 FFRs are respiratory protective devices (RPDs) designed to efficiently filter aerosols. During the COVID-19 pandemic, health care workers (HCWs) throughout the world continue to face shortages of disposable N95 FFRs. Existing version of widely available FDA cleared loose-fitting surgical masks with straps do not provide reliable protection against aerosols. We tested the faceseal of a modified strapless form-fitting sealed version of surgical mask using quantitative fit testing (QNFT) and compared the performance of this mask with that of N95 FFRs and unmodified loose-fitting surgical masks. Methods: Twenty HCWs participated in the study (10 women; 10 men; age 23–59 years). To create the sealed surgical masks, we removed the straps from loose-fitting surgical masks, made new folds, and used adhesive medical tape to secure the new design. All participants underwent QNFT with a loose-fitting surgical mask, the sealed surgical mask, and an N95 FFR; fit factors were recorded. Each QNFT was performed using a protocol of four exercises: (i) bending over, (ii) talking, (iii) moving head side to side, and (iv) moving head up and down. When the overall fit factor for the sealed surgical mask or N95 FFR was <100, the participant retook the test. Participants scored the breathability and comfort of the sealed surgical mask and N95 FFR on a visual analog scale (VAS) ranging from 0 (unfavorable) to 10 (favorable). Results: The median fit factor for the sealed surgical mask (53.8) was significantly higher than that of the loose-fitting surgical mask (3.0) but lower than that of the N95 FFR (177.0) (P < 0.001), equating to significantly lower inward leakage of ambient aerosols (measuring 0.04–0.06 µm) with the sealed surgical mask (geometric mean 1.79%; geometric standard deviation 1.45%; range 0.97–4.03%) than with the loose-fitting surgical mask (29.5%; 2.01%; 25–100.0%) but still higher than with the N95 FFR (0.66%; 1.46%; 0.50–1.97%) (P < 0.001). Sealed surgical masks led to a marked reduction (range 60–98%) in inward leakage of aerosols in all the participants, compared to loose-fitting surgical masks. Among the exercises, talking had a greater effect on reducing overall fit factor for the sealed surgical mask than for the N95 FFR; when talking was excluded, the fit factor for the sealed surgical mask improved significantly (median 53.8 to 81.5; P < 0.001). The sealed surgical mask, when compared with the N95 FFR, offered better reported breathability (median VAS 9 versus 5; P < 0.001) and comfort (9 versus 5; P < 0.001). Conclusions: Widely available loose-fitting surgical masks can be easily modified to achieve faceseal with adhesives. Unlike loose-fitting surgical masks, sealed surgical masks can markedly reduce inward leakage of aerosols and may therefore offer useful levels of respiratory protection during an extreme shortage of N95 FFRs and could benefit HCWs who cannot comply with N95 FFRs due to intolerance. However, because a wide range of surgical masks is commercially available, individual evaluation of such masks is highly recommended before sealed versions are used as RPDs.
- 1 February 2019
- Published by Oxford University Press (OUP) in British Journal of Radiology
- Vol. 92 (1094) , 20180336
Independent usefulness of flow phase99mTc-red blood cell scintigraphy in predicting the results of angiography in acute gastrointestinal bleeding
Objective: In acute gastrointestinal bleeding, despite positive dynamic phase (99)mTc-red blood cell scintigraphy, invasive catheter angiography (CA) is frequently negative. In this study, we investigated the value of flow phase scintigraphy in predicting extravasation on CA. Methods: Institutional review board approval with a waiver of informed consent was obtained for this retrospective study. A total of 173 scintigraphy procedures performed in 145 patients with GIB between January 2013 and August 2014 were analysed. Scintigraphy had two phases: flow (1 image/s for 1 min) followed by dynamic (1 image/30 s for 1 h). Patients who underwent CA within 24 hours of positive scintigraphy were assessed. Each scintigraphy phase was randomly and independently reviewed by two nuclear medicine physicians blinded to the outcomes of the other phase and of CA. Results: A total of 42 patients (29%) had positive scintigraphy. Of these patients, 29 underwent CA, and extravasation was seen in 6 (21%). In all, dynamic phase scintigraphy was positive. 13 of the 29 patients also had positive flow phase scintigraphy. The sensitivity, specificity, positive-predictive value, and negative-predictive value of flow phase scintigraphy for extravasation on CA were 100, 70, 46, and 100%, respectively. Specificity and positive predictive value were higher when CA was performed within 4 hours of positive flow phase scintigraphy. Conclusions: Negative flow phase scintigraphy can identify patients who will not benefit from CA despite positive dynamic phase scintigraphy. The likelihood of extravasation on CA is higher when performed soon after positive flow phase scintigraphy. Advances in knowledge: Negative flow phase scintigraphy identifies patients who will not benefit from invasive catheter angiography despite positive results on subsequent dynamic phase scintigraphy. Increasing the delay between positive red blood cell scintigraphy and catheter angiography progressively reduces the likelihood of identifying extravasation, which is required to target embolization.
- 1 February 2019
- Published by Oxford University Press (OUP) in British Journal of Radiology
- Vol. 92 (1094) , 20180336
Independent usefulness of flow phase99mTc-red blood cell scintigraphy in predicting the results of angiography in acute gastrointestinal bleeding
Objective: In acute gastrointestinal bleeding, despite positive dynamic phase (99)mTc-red blood cell scintigraphy, invasive catheter angiography (CA) is frequently negative. In this study, we investigated the value of flow phase scintigraphy in predicting extravasation on CA. Methods: Institutional review board approval with a waiver of informed consent was obtained for this retrospective study. A total of 173 scintigraphy procedures performed in 145 patients with GIB between January 2013 and August 2014 were analysed. Scintigraphy had two phases: flow (1 image/s for 1 min) followed by dynamic (1 image/30 s for 1 h). Patients who underwent CA within 24 hours of positive scintigraphy were assessed. Each scintigraphy phase was randomly and independently reviewed by two nuclear medicine physicians blinded to the outcomes of the other phase and of CA. Results: A total of 42 patients (29%) had positive scintigraphy. Of these patients, 29 underwent CA, and extravasation was seen in 6 (21%). In all, dynamic phase scintigraphy was positive. 13 of the 29 patients also had positive flow phase scintigraphy. The sensitivity, specificity, positive-predictive value, and negative-predictive value of flow phase scintigraphy for extravasation on CA were 100, 70, 46, and 100%, respectively. Specificity and positive predictive value were higher when CA was performed within 4 hours of positive flow phase scintigraphy. Conclusions: Negative flow phase scintigraphy can identify patients who will not benefit from CA despite positive dynamic phase scintigraphy. The likelihood of extravasation on CA is higher when performed soon after positive flow phase scintigraphy. Advances in knowledge: Negative flow phase scintigraphy identifies patients who will not benefit from invasive catheter angiography despite positive results on subsequent dynamic phase scintigraphy. Increasing the delay between positive red blood cell scintigraphy and catheter angiography progressively reduces the likelihood of identifying extravasation, which is required to target embolization.
- 26 November 2018
- Published by Georg Thieme Verlag KG in Digestive Disease Interventions
- Vol. 02 (04) , 395-401
Predictors and Management of Hepatic Encephalopathy after Transjugular Intrahepatic Portosystemic Shunt: The Current State of Literature
Hepatic encephalopathy is a well-known sequela of transjugular intrahepatic portosystemic shunt (TIPS) insertion, but objective clinical and laboratory predictors remain poorly elucidated. Numerous medical and interventional strategies have also been described, though little consensus has been reached on the optimal treatment technique to improve morbidity and mortality in patients who develop refractory encephalopathy. To improve TIPS candidate selection and prognostication, this review consolidates predictive factors for post-TIPS encephalopathy and offers an updated description of historical and contemporary interventional techniques for management. Despite the abundant literature on treatment strategies, large studies directly comparing outcomes between the various techniques are nonexistent.
- 26 November 2018
- Published by Georg Thieme Verlag KG in Digestive Disease Interventions
- Vol. 02 (04) , 395-401
Predictors and Management of Hepatic Encephalopathy after Transjugular Intrahepatic Portosystemic Shunt: The Current State of Literature
Hepatic encephalopathy is a well-known sequela of transjugular intrahepatic portosystemic shunt (TIPS) insertion, but objective clinical and laboratory predictors remain poorly elucidated. Numerous medical and interventional strategies have also been described, though little consensus has been reached on the optimal treatment technique to improve morbidity and mortality in patients who develop refractory encephalopathy. To improve TIPS candidate selection and prognostication, this review consolidates predictive factors for post-TIPS encephalopathy and offers an updated description of historical and contemporary interventional techniques for management. Despite the abundant literature on treatment strategies, large studies directly comparing outcomes between the various techniques are nonexistent.
- 20 August 2018
- Published by Georg Thieme Verlag KG in Digestive Disease Interventions
- Vol. 02 (03) , 256-265
Visceral Artery Aneurysms and Pseudoaneurysms: Etiology, Diagnosis, and Endovascular Management
Visceral artery aneurysms (VAAs) are rare entities arising from several locations in the mesenteric vasculature. The etiology, clinical presentation, and subsequent management of these aneurysms vary widely. Although true aneurysms and pseudoaneurysms can present similarly on imaging, by definition they are distinct in their structural composition and hence may require tailored interventional planning. Treatment conventionally involves open surgery, endovascular intervention or careful observation. Recently, endovascular approaches have shown increasing popularity given the higher success rates and shorter lengths of stay with these procedures versus surgery. Optimal endovascular treatment planning is determined by the interventionalist based on unique features of each aneurysm and underlying vascular anatomy. This article reviews the etiology, diagnosis, and endovascular management for VAAs and pseudoaneurysms.
- 20 August 2018
- Published by Georg Thieme Verlag KG in Digestive Disease Interventions
- Vol. 02 (03) , 256-265
Visceral Artery Aneurysms and Pseudoaneurysms: Etiology, Diagnosis, and Endovascular Management
Visceral artery aneurysms (VAAs) are rare entities arising from several locations in the mesenteric vasculature. The etiology, clinical presentation, and subsequent management of these aneurysms vary widely. Although true aneurysms and pseudoaneurysms can present similarly on imaging, by definition they are distinct in their structural composition and hence may require tailored interventional planning. Treatment conventionally involves open surgery, endovascular intervention or careful observation. Recently, endovascular approaches have shown increasing popularity given the higher success rates and shorter lengths of stay with these procedures versus surgery. Optimal endovascular treatment planning is determined by the interventionalist based on unique features of each aneurysm and underlying vascular anatomy. This article reviews the etiology, diagnosis, and endovascular management for VAAs and pseudoaneurysms.
- Open Access
- 1 April 2018
- Published by Elsevier in Journal of Vascular and Interventional Radiology
- Vol. 29 (4) , S126-S127
3:18 PM Abstract No. 294 Determining endovascular proficiency among interventional radiology practitioners using a homemade physical simulator and simulation-based metrics
- 1 April 2018
- Published by Elsevier in Journal of Vascular and Interventional Radiology
- Vol. 29 (4) , S126-S127
Open Access3:18 PM Abstract No. 294 Determining endovascular proficiency among interventional radiology practitioners using a homemade physical simulator and simulation-based metrics