ASAbdul Wahab M. Sharfo

Abdul Wahab M. Sharfo

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Abdul Wahab M. Sharfo has a total of 49 co-authors. Here are the top co-authors by number of shared publications:

  • Sebastiaan Breedveld

    Department of Radiotherapy, Erasmus MC Cancer Institute, University Medical Center, Rotterdam, Netherlands

    6 shared publications
  • Ben J. M. Heijmen

    Erasmus MC Cancer Institute, University Medical Center Rotterdam, Department of Radiotherapy, The Netherlands

    4 shared publications
  • Ben J.M. Heijmen

    Department of Radiation Oncology, Erasmus MC Cancer Institute, Rotterdam, the Netherlands

    3 shared publications
  • Linda Rossi

    Department of Radiotherapy, Erasmus MC Cancer Institute, University Medical Center Rotterdam, Rotterdam, The Netherlands

    3 shared publications
  • Sebastiaan Breedveld

    Erasmus MC Cancer Institute, University Medical Center Rotterdam, Department of Radiotherapy, Rotterdam, The Netherlands

    3 shared publications
  • Shafak Aluwini

    Department of Radiotherapy, Erasmus MC Cancer Institute, University Medical Center, Rotterdam, Netherlands

    3 shared publications

Latest Publications

  • Open Access

    From non-coplanar CyberKnife to coplanar Ethos in liver SBRT?

    by Linda Chen, Linda Rossi, Martin Otto, Wilhelm Den Toom, Abdul Wahab M. Sharfo, Ben Heijmen, Yvette Seppenwoolde, Alejandra Méndez Romero

    PurposeThe robotic CyberKnife (CK) is well-established for liver SBRT, but in contrast to Ethos systems, CK does not support online adaptive radiotherapy (oART) for coping with non-rigid motion. CK uses IMRT with non-coplanar beam angle setups that lack posterior beams, whilst Ethos features full-arc VMAT treatments, but only coplanar. In this study, we investigated the dosimetric impact of the beam angle differences between the two modalities (Ethos vs. CK), and benchmarked the manual planning for Ethos against high-quality automated planning (Ethos vs. autoVMAT).MethodsForty-nine patients with liver metastases, previously treated with CK, were included. Patients were treated with 60Gy in 3, 5 or 8 fractions. Ethos plans were generated by an expert planner. Our automated multi-criterial plan optimizer was configured for liver SBRT for generation of autoVMAT benchmark plans. Wilcoxon signed-rank-tests with corrections for multiple testing were used for statistical significance testing. ResultsDifferences between Ethos and CK in attained PTV coverage were not significant, with equal numbers of patients with PTV underdose because of limiting OAR constraints (13/49). Most OAR dose parameters were equivalent, with some favouring Ethos or CK. Ethos had fewer constraint violations than CK (9 vs. 12); these were mostly minor for both modalities. Ethos VMAT plan quality approached the level of high-quality autoVMAT benchmark plans. ConclusionDespite markedly different beam arrangements, Ethos and CK plans for liver metastases were dosimetrically equivalent. Quality of manual Ethos plans approached autoVMAT plan quality. This study supports clinical use of Ethos to leverage the benefits of oART.

  • PO-1422 Feasibility of bone marrow sparing VMAT and Dixon MRI for the PROTECT study

    by A. Corbeau, R. Nout, S. Kuipers, E. Astreinidou, J.W. Mens, E. Harderwijk, B. Nielen, P. Wielopolski, A. Sharfo, N. Horeweg, et al.

  • Open Access

    Pre-clinical validation of a novel system for fully-automated treatment planning

    by Rik Bijman, Abdul Wahab Sharfo, Linda Rossi, Sebastiaan Breedveld, Ben Heijmen


  • Open Access

    Complementing Prostate SBRT VMAT With a Two-Beam Non-Coplanar IMRT Class Solution to Enhance Rectum and Bladder Sparing With Minimum Increase in Treatment Time

    by Abdul Wahab M. Sharfo, Linda Rossi, Maarten L. P. Dirkx, Sebastiaan Breedveld, Shafak Aluwini, Ben J. M. Heijmen

    Purpose: Enhance rectum and bladder sparing in prostate SBRT with minimum increase in treatment time by complementing dual-arc coplanar VMAT with a two-beam non-coplanar IMRT class solution (CS).Methods: For twenty patients, an optimizer for automated multi-criterial planning with integrated beam angle optimization (BAO) was used to generate dual-arc VMAT plans, supplemented with five non-coplanar IMRT beams with individually optimized orientations (VMAT+5). In all plan generations, reduction of high rectum dose had the highest priority after obtaining adequate PTV coverage. A CS with two most preferred directions in VMAT+5 and largest rectum dose reductions compared to dual-arc VMAT was then selected to define VMAT+CS. VMAT+CS was compared with automatically generated i) dual-arc coplanar VMAT plans (VMAT), ii) VMAT+5 plans, and iii) IMRT plans with 30 patient-specific non-coplanar beam orientations (30-NCP). Plans were generated for a 4 x 9.5 Gy fractionation scheme. Differences in PTV doses, healthy tissue sparing, and computation and treatment delivery times were quantified.Results: For equal PTV coverage, VMAT+CS, consisting of dual-arc VMAT supplemented with two fixed, non-coplanar IMRT beams with fixed Gantry/Couch angles of 65°/30° and 295°/-30°, significantly reduced OAR doses and the dose bath, compared to dual-arc VMAT. Mean relative differences in rectum Dmean, D1cc, V40GyEq and V60GyEq were 19.4 ± 10.6%, 4.2 ± 2.7%, 34.9 ± 20.3%, and 39.7 ± 23.2%, respectively (all p1cc, while bladder Dmean reduced by 17.9 ± 11.0% (p5%, D10%, and D50% showed small, but statistically significant improvements. All patient VX with X = 2, 5, 10, 20, and 30 Gy were reduced with VMAT+CS, with a maximum relative reduction for V10Gy of 19.0 ± 7.3% (p<0.001). Total delivery times with VMAT+CS only increased by 1.9 ± 0.7 min compared to VMAT (9.1 ± 0.7 min). The dosimetric quality of VMAT+CS plans was equivalent to VMAT+5, while optimization times were reduced by a factor of 25 due to avoidance of individualized BAO. Compared to VMAT+CS, the 30-NCP plans were only favorable in terms of dose bath, at the cost of much enhanced optimization and delivery times.Conclusions: The proposed two-beam non-coplanar class solution to complement coplanar dual-arc VMAT resulted in substantial plan quality improvements for OARs (especially rectum) and reduced irradiated patient volumes with minor increases in treatment delivery times.


  • Late toxicity in the randomized multicenter HYPRO trial for prostate cancer analyzed with automated treatment planning

    by Abdul Wahab M. Sharfo, Maarten L.P. Dirkx, Rik G. Bijman, Wilco Schillemans, Sebastiaan Breedveld, Shafak Aluwini, Floris Pos, Luca Incrocci, Ben J.M. Heijmen


  • Open Access

    First fully automated planning solution for robotic radiosurgery – comparison with automatically planned volumetric arc therapy for prostate cancer

    by Linda Rossi, Abdul Wahab Sharfo, Shafak Aluwini, Maarten Dirkx, Sebastiaan Breedveld, Ben Heijmen

    Background: For conventional radiotherapy treatment units, automated planning can significantly improve plan quality. For robotic radiosurgery, systems for automatic generation of clinically deliverable plans do not yet exist. For prostate stereotactic body radiation therapy (SBRT), few studies have systematically compared VMAT with robotic treatment. Material and methods: The multi-criteria autoplanning optimizer, developed at our institute, was coupled to the commercial treatment planning system of our robotic treatment unit, for fully automated generation of clinically deliverable plans (autoROBOT). The system was then validated by comparing autoROBOT plans with manually generated plans. Next, the autoROBOT system was used for systematic comparisons between autoROBOT plans and VMAT plans, that were also automatically generated (autoVMAT). CTV-PTV margins of 3 mm were used for autoROBOT (clinical routine) and autoVMAT plan generation. For autoVMAT, an extra plan was generated with 5 mm margin (often applied for VMAT). Plans were generated for a 4 × 9.5 Gy fractionation scheme. Results: Compared to manual planning, autoROBOT improved rectum D (16%), V (75%) and D (41%), and bladder D (37%) (all p .002), with equal PTV coverage. In the autoROBOT and autoVMAT comparison, both with 3 mm margin, rectum doses were lower for autoROBOT by 5% for rectum D (p=.002), 33% for V (p=.001) and 4% for D (p=.05), with comparable PTV coverage and other OAR sparing. With 5 mm margin for VMAT, 18/20 plans had a PTV coverage lower than requested (D , 69% for V and 32% for D (all p<.001)). Conclusions: The first system for fully automated generation of clinically deliverable robotic plans was built. Autoplanning did largely enhance robotic plan quality, compared to manual planning. Using autoplanning for both the robotic system and VMAT, superiority of non-coplanar robotic treatment compared to coplanar VMAT for prostate SBRT was demonstrated.


  • Open Access

    Automated VMAT planning for postoperative adjuvant treatment of advanced gastric cancer

    by Abdul Wahab M. Sharfo, Florian Stieler, Oskar Kupfer, Ben J. M. Heijmen, Maarten L. P. Dirkx, Sebastiaan Breedveld, Frederik Wenz, Frank Lohr, Judit Boda-Heggemann, Daniel Buergy

    Postoperative/adjuvant radiotherapy of advanced gastric cancer involves a large planning target volume (PTV) with multi-concave shapes which presents a challenge for volumetric modulated arc therapy (VMAT) planning. This study investigates the advantages of automated VMAT planning for this site compared to manual VMAT planning by expert planners. For 20 gastric cancer patients in the postoperative/adjuvant setting, dual-arc VMAT plans were generated using fully automated multi-criterial treatment planning (autoVMAT), and compared to manually generated VMAT plans (manVMAT). Both automated and manual plans were created to deliver a median dose of 45 Gy to the PTV using identical planning and segmentation parameters. Plans were evaluated by two expert radiation oncologists for clinical acceptability. AutoVMAT and manVMAT plans were also compared based on dose-volume histogram (DVH) and predicted normal tissue complication probability (NTCP) analysis. Both manVMAT and autoVMAT plans were considered clinically acceptable. Target coverage was similar (manVMAT: 96.6 ± 1.6%, autoVMAT: 97.4 ± 1.0%, p = 0.085). With autoVMAT, median kidney dose was reduced on average by > 25%; (for left kidney from 11.3 ± 2.1 Gy to 8.9 ± 3.5 Gy (p = 0.002); for right kidney from 9.2 ± 2.2 Gy to 6.1 ± 1.3 Gy (p < 0.001)). Median dose to the liver was lower as well (18.8 ± 2.3 Gy vs. 17.1 ± 3.6 Gy, p = 0.048). In addition, Dmax of the spinal cord was significantly reduced (38.3 ± 3.7 Gy vs. 31.6 ± 2.6 Gy, p < 0.001). Substantial improvements in dose conformity and integral dose were achieved with autoVMAT plans (4.2% and 9.1%, respectively; p < 0.001). Due to the better OAR sparing in the autoVMAT plans compared to manVMAT plans, the predicted NTCPs for the left and right kidney and the liver-PTV were significantly reduced by 11.3%, 12.8%, 7%, respectively (p ≤ 0.001). Delivery time and total number of monitor units were increased in autoVMAT plans (from 168 ± 19 s to 207 ± 26 s, p = 0.006) and (from 781 ± 168 MU to 1001 ± 134 MU, p = 0.003), respectively. For postoperative/adjuvant radiotherapy of advanced gastric cancer, involving a complex target shape, automated VMAT planning is feasible and can substantially reduce the dose to the kidneys and the liver, without compromising the target dose delivery.


  • VMAT plus a few computer-optimized non-coplanar IMRT beams (VMAT+) tested for liver SBRT

    by Abdul Wahab M. Sharfo, Maarten L.P. Dirkx, Sebastiaan Breedveld, Alejandra Méndez Romero, Ben J.M. Heijmen


  • Open Access

    Fully automated treatment planning of spinal metastases – A comparison to manual planning of Volumetric Modulated Arc Therapy for conventionally fractionated irradiation

    by Daniel Buergy, Abdul Wahab M. Sharfo, Ben J. M. Heijmen, Peter W. J. Voet, Sebastiaan Breedveld, Frederik Wenz, Frank Lohr, Florian Stieler

    Planning for Volumetric Modulated Arc Therapy (VMAT) may be time consuming and its use is limited by available staff resources. Automated multicriterial treatment planning can eliminate this bottleneck. We compared automatically created (auto) VMAT plans generated by Erasmus-iCycle to manually created VMAT plans for treatment of spinal metastases. Forty-two targets in 32 patients were analyzed. Lungs and kidneys were defined as organs at risk (OARs). Twenty-two patients received radiotherapy on kidney levels, 17 on lung levels, and 3 on both levels. All Erasmus-iCycle plans were clinically acceptable. When compared to manual plans, planning target volume (PTV) coverage of auto plans was significantly better. The Homogeneity Index did not differ significantly between the groups. Mean dose to OARs was lower in auto plans concerning both kidneys and the left lung. One hotspot (>110% of D50%) occurred in the spinal cord of one auto plan (33.2 Gy, D50%: 30 Gy). Treatment time was 7% longer in auto plans. Erasmus-iCycle plans showed better target coverage and sparing of OARs at the expense of minimally longer treatment times (for which no constraint was set).


  • Open Access

    Validation of Fully Automated VMAT Plan Generation for Library-Based Plan-of-the-Day Cervical Cancer Radiotherapy

    by Abdul Wahab M. Sharfo, Sebastiaan Breedveld, Peter W. J. Voet, Sabrina T. Heijkoop, Jan-Willem M. Mens, Mischa S. Hoogeman, Ben J. M. Heijmen

    To develop and validate fully automated generation of VMAT plan-libraries for plan-of-the-day adaptive radiotherapy in locally-advanced cervical cancer. Our framework for fully automated treatment plan generation (Erasmus-iCycle) was adapted to create dual-arc VMAT treatment plan libraries for cervical cancer patients. For each of 34 patients, automatically generated VMAT plans (autoVMAT) were compared to manually generated, clinically delivered 9-beam IMRT plans (CLINICAL), and to dual-arc VMAT plans generated manually by an expert planner (manVMAT). Furthermore, all plans were benchmarked against 20-beam equi-angular IMRT plans (autoIMRT). For all plans, a PTV coverage of 99.5% by at least 95% of the prescribed dose (46 Gy) had the highest planning priority, followed by minimization of V45Gy for small bowel (SB). Other OARs considered were bladder, rectum, and sigmoid. All plans had a highly similar PTV coverage, within the clinical constraints (above). After plan normalizations for exactly equal median PTV doses in corresponding plans, all evaluated OAR parameters in autoVMAT plans were on average lower than in the CLINICAL plans with an average reduction in SB V45Gy of 34.6% (p45Gy was lower than for manVMAT (p15Gy increased by 2.3% (p = 0.011). AutoIMRT reduced SB V45Gy by another 2.7% compared to autoVMAT, while also resulting in a 9.0% reduction in SB V15Gy (p<0.001), but with a prolonged delivery time. Differences between manVMAT and autoVMAT in bladder, rectal and sigmoid doses were ≤ 1%. Improvements in SB dose delivery with autoVMAT instead of manVMAT were higher for empty bladder PTVs compared to full bladder PTVs, due to differences in concavity of the PTVs. Quality of automatically generated VMAT plans was superior to manually generated plans. Automatic VMAT plan generation for cervical cancer has been implemented in our clinical routine. Due to the achieved workload reduction, extension of plan libraries has become feasible.