Dzmitry Maneuski
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Dzmitry Maneuski has a total of 150 co-authors. Here are the top co-authors by number of shared publications:
- Andrew Blue
University of Glasgow
5 shared publications - Neil Moffat
Instituto de Microelectrónica de Barcelona (IMB-CNM-CSIC), Barcelona, Spain
4 shared publications R Bates
4 shared publicationsN Tartoni
Diamond Light Source Ltd., Didcot, Oxfordshire, OX11 0DE, United Kingdom
3 shared publicationsR M Zain
3 shared publicationsR. Bates
3 shared publications
Latest Publications
- Open Access
- 1 November 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 26 (21) , 32455-32463
Evaluation of Low-Gain Avalanche Detectors (LGADs) Coupled to the Timepix3 ASIC Using a Micro-Focused X-Ray Beam
- 1 November 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 26 (21) , 32455-32463
Open AccessEvaluation of Low-Gain Avalanche Detectors (LGADs) Coupled to the Timepix3 ASIC Using a Micro-Focused X-Ray Beam
- Open Access
- 1 November 2024
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 19 (11) , C11006
Laboratory and beam-test performance study of a 55 µm pitch iLGAD sensor bonded to a Timepix3 readout chip
This contribution reports on characterisation results of a large-area (2 cm2) small pitch (55 µm) inverse Low-Gain Avalanche Detector (iLGAD), bonded to a Timepix3 readout chip. The ilGAD sensors were produced by Micron Semiconductor Ltd with the goal to obtain good gain uniformity and maximise the fill-factor — an issue present with standard small-pitch LGAD designs. We have conducted detailed performance evaluations using both X-ray calibrations and beam tests. An X-ray fluorescence setup has been used to obtain energy calibration and to identify the optimal operating settings of the new devices, whereas the extensive beam tests allowed for a detailed evaluation of the detector performance. The beam-tests were performed at the CERN SPS North Area H6 beamline, using a 120 GeV/c pion beam. The reference tracking and time-stamping is achieved by a Timepix3-based beam telescope setup. The results show a gain of around 5 with very good uniformity, measured across the whole gain area, as well as a hit time resolution down to 1.3 ns without correcting for the time-walk effects. Furthermore, it is shown that the gain opens the possibility of a good X-ray energy resolution down to 4.5 keV.
- 1 November 2024
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 19 (11) , C11006
Open AccessLaboratory and beam-test performance study of a 55 µm pitch iLGAD sensor bonded to a Timepix3 readout chip
This contribution reports on characterisation results of a large-area (2 cm2) small pitch (55 µm) inverse Low-Gain Avalanche Detector (iLGAD), bonded to a Timepix3 readout chip. The ilGAD sensors were produced by Micron Semiconductor Ltd with the goal to obtain good gain uniformity and maximise the fill-factor — an issue present with standard small-pitch LGAD designs. We have conducted detailed performance evaluations using both X-ray calibrations and beam tests. An X-ray fluorescence setup has been used to obtain energy calibration and to identify the optimal operating settings of the new devices, whereas the extensive beam tests allowed for a detailed evaluation of the detector performance. The beam-tests were performed at the CERN SPS North Area H6 beamline, using a 120 GeV/c pion beam. The reference tracking and time-stamping is achieved by a Timepix3-based beam telescope setup. The results show a gain of around 5 with very good uniformity, measured across the whole gain area, as well as a hit time resolution down to 1.3 ns without correcting for the time-walk effects. Furthermore, it is shown that the gain opens the possibility of a good X-ray energy resolution down to 4.5 keV.
- Open Access
- 11 December 2023
- Published by IOP Publishing in Physica Scripta
- Vol. 99 (1) , 015301
Characterization of a 5 mm thick CZT-Timepix3 pixel detector for energy-dispersive γ-ray and particle tracking
The present manuscript describes a comprehensive characterization of a novel highly segmented 5 mm CZT sensor attached to Timepix3. First, the sensor’s IV curve was measured and basic sensor characterization was done with laboratory γ-radiation sources. The sensor resistivity was determined to be (0.155± 0.02) GOhm · cm. The sensor showed decent homogeneity, both for the per-pixel count rate and electron mobility-lifetime product μ e τ e. The latter was measured to be μ e τ e ¯ = 1.3 × 10−3 cm2/V with a standard deviation σ = 0.4 × 10−3 cm2/V describing the dispersion of values for different pixels. The basic sensor characterization is complemented by measurements at grazing angle in a 120 GeV/c at the CERN’s Super Proton Synchrotron. The penetrating nature of these particles together with the pixelation of the sensor allows for a determination of the charge collection efficiency (CCE), as well as charge carrier drift properties (drift times, lateral charge cloud expansion) as a function of the interaction depths in the sensor. While CCE drops by 30%–40% towards the cathode side of the sensor, from the drift time dependency on interaction depth, the electron mobility μ e was extracted to be (944.8 ± 1.3) cm2/V/s and τ e = (1.38 ± 0.31) μs. The spectroscopic performance was assessed in photon fields and extracted from energy loss spectra measured at different angles in the pion beam. While at photon energies below 120 keV incomplete charge collection leads to an underestimation of the photon energy when irradiated from the front-side, at higher energies the relative energy resolution was found to be ∼4.5%, while a relative energy resolution of ∼7.5% was found for the particle energy loss spectra. It is shown that the drift time information can be used to reconstruct particle interactions in the sensor in 3D, providing a spatial resolution of σ xyz = 241 μm within the sensor volume and a particle trajectory measurement precision Δxyz = 100 μm, at a distance of 1 m from the sensor. We demonstrate by measurement with a 22Na source, that the energy resolution combined with the 3D reconstruction allows for detection of γ-ray source location and polarity using Compton scattering within the sensor (Compton camera and scatter polarimeter).
- 11 December 2023
- Published by IOP Publishing in Physica Scripta
- Vol. 99 (1) , 015301
Open AccessCharacterization of a 5 mm thick CZT-Timepix3 pixel detector for energy-dispersive γ-ray and particle tracking
The present manuscript describes a comprehensive characterization of a novel highly segmented 5 mm CZT sensor attached to Timepix3. First, the sensor’s IV curve was measured and basic sensor characterization was done with laboratory γ-radiation sources. The sensor resistivity was determined to be (0.155± 0.02) GOhm · cm. The sensor showed decent homogeneity, both for the per-pixel count rate and electron mobility-lifetime product μ e τ e. The latter was measured to be μ e τ e ¯ = 1.3 × 10−3 cm2/V with a standard deviation σ = 0.4 × 10−3 cm2/V describing the dispersion of values for different pixels. The basic sensor characterization is complemented by measurements at grazing angle in a 120 GeV/c at the CERN’s Super Proton Synchrotron. The penetrating nature of these particles together with the pixelation of the sensor allows for a determination of the charge collection efficiency (CCE), as well as charge carrier drift properties (drift times, lateral charge cloud expansion) as a function of the interaction depths in the sensor. While CCE drops by 30%–40% towards the cathode side of the sensor, from the drift time dependency on interaction depth, the electron mobility μ e was extracted to be (944.8 ± 1.3) cm2/V/s and τ e = (1.38 ± 0.31) μs. The spectroscopic performance was assessed in photon fields and extracted from energy loss spectra measured at different angles in the pion beam. While at photon energies below 120 keV incomplete charge collection leads to an underestimation of the photon energy when irradiated from the front-side, at higher energies the relative energy resolution was found to be ∼4.5%, while a relative energy resolution of ∼7.5% was found for the particle energy loss spectra. It is shown that the drift time information can be used to reconstruct particle interactions in the sensor in 3D, providing a spatial resolution of σ xyz = 241 μm within the sensor volume and a particle trajectory measurement precision Δxyz = 100 μm, at a distance of 1 m from the sensor. We demonstrate by measurement with a 22Na source, that the energy resolution combined with the 3D reconstruction allows for detection of γ-ray source location and polarity using Compton scattering within the sensor (Compton camera and scatter polarimeter).
- Open Access
- 22 November 2023
- Published by Elsevier in Applied Radiation and Isotopes
- Vol. 204, 111120
TCAD simulations of internal amplification in high purity germanium detectors
- 22 November 2023
- Published by Elsevier in Applied Radiation and Isotopes
- Vol. 204, 111120
Open AccessTCAD simulations of internal amplification in high purity germanium detectors
- Open Access
Inverse LGAD (iLGAD) Periphery Optimization for Surface Damage Irradiation
Pixelated LGADs have been established as the baseline technology for timing detectors for the High Granularity Timing Detector (HGTD) and the Endcap Timing Layer (ETL) of the ATLAS and CMS experiments, respectively. The drawback of segmenting an LGAD is the non-gain area present between pixels and the consequent reduction in the fill factor. To overcome this issue, the inverse LGAD (iLGAD) technology has been proposed by IMB-CNM to enhance the fill factor and provide excellent tracking capabilities. In this work, we explore the use of iLGAD sensors for surface damage irradiation by developing a new generation of iLGADs, the periphery of which is optimized to improve the performance of irradiated sensors. The fabricated iLGAD sensors exhibit good electrical performances before and after X-ray irradiation.
Open AccessInverse LGAD (iLGAD) Periphery Optimization for Surface Damage Irradiation
Pixelated LGADs have been established as the baseline technology for timing detectors for the High Granularity Timing Detector (HGTD) and the Endcap Timing Layer (ETL) of the ATLAS and CMS experiments, respectively. The drawback of segmenting an LGAD is the non-gain area present between pixels and the consequent reduction in the fill factor. To overcome this issue, the inverse LGAD (iLGAD) technology has been proposed by IMB-CNM to enhance the fill factor and provide excellent tracking capabilities. In this work, we explore the use of iLGAD sensors for surface damage irradiation by developing a new generation of iLGADs, the periphery of which is optimized to improve the performance of irradiated sensors. The fabricated iLGAD sensors exhibit good electrical performances before and after X-ray irradiation.
- Open Access
- 1 August 2021
- Published by Elsevier in Ultramicroscopy
- Vol. 227, 113298
Quantifying the performance of a hybrid pixel detector with GaAs:Cr sensor for transmission electron microscopy
- 1 August 2021
- Published by Elsevier in Ultramicroscopy
- Vol. 227, 113298
Open AccessQuantifying the performance of a hybrid pixel detector with GaAs:Cr sensor for transmission electron microscopy
- Open Access
- 1 October 2019
- Published by IOP Publishing in Journal of Physics D: Applied Physics
- Vol. 53 (1) , 015114
TCAD simulation studies of novel geometries for CZT ring-drift detectors
In this work, technology computer-aided design (TCAD) simulation results of new CZT ring-drift detector geometries are presented. The physics model was developed and validated against the results from an existing device which had been comprehensively characterised at x-ray wavelengths. The model was then applied to new detector geometries and a systematic study of the parameters influencing charge collection performed. A comparison between one- two- and three-ring circle and semi-rectangular (or squircle) geometries is presented. In was found that charge collection with the squircle ring configuration was systematically better than the circular configuration and extends approximately m further from the collecting anode. In addition, a two-ring geometry device is shown to collect charge m and m further from the anode when compared to one- and three- ring geometries, respectively. Based on these results, we derive an optimum configuration which potentially can be multiplied on larger crystals, offering an increased charge collection volume without compromising energy resolution.
- 1 October 2019
- Published by IOP Publishing in Journal of Physics D: Applied Physics
- Vol. 53 (1) , 015114
Open AccessTCAD simulation studies of novel geometries for CZT ring-drift detectors
In this work, technology computer-aided design (TCAD) simulation results of new CZT ring-drift detector geometries are presented. The physics model was developed and validated against the results from an existing device which had been comprehensively characterised at x-ray wavelengths. The model was then applied to new detector geometries and a systematic study of the parameters influencing charge collection performed. A comparison between one- two- and three-ring circle and semi-rectangular (or squircle) geometries is presented. In was found that charge collection with the squircle ring configuration was systematically better than the circular configuration and extends approximately m further from the collecting anode. In addition, a two-ring geometry device is shown to collect charge m and m further from the anode when compared to one- and three- ring geometries, respectively. Based on these results, we derive an optimum configuration which potentially can be multiplied on larger crystals, offering an increased charge collection volume without compromising energy resolution.
- Open Access
- 1 July 2017
- Published by Elsevier in Applied Radiation and Isotopes
- Vol. 125, 9-14
On the use of positron counting for radio-Assay in nuclear pharmaceutical production
- 1 July 2017
- Published by Elsevier in Applied Radiation and Isotopes
- Vol. 125, 9-14
Open AccessOn the use of positron counting for radio-Assay in nuclear pharmaceutical production